Loading...
HomeMy WebLinkAboutSWG2025-00092 - SWG Application / Design - 3/20/2025 MASON COUNTY 415N6THELTON:STREET,SHELT967 ,EXT 400 SHELTON:360-275 9170,EXT 400 BELFAIR:360-275-046T,E%T 400 Public Health & Human Services ELMA:360482-5269,E%T 400 FAX:360427-7787 On-Site Sewage System Permit: SWG2025-00092 APPLICANT AB FINE HOMES LLC Phone: 360-898-0055 X 3 Address: 871 E BEACH DR UNION,WA 98592 OWNER AB FINE HOMES LLC Phone: 360-898-0055 X 3 Address: 871 E BEACH DR UNION,WA 98592 SEPTIC DESIGNER PAULAJOHNSONe Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION, WA 98592 SEPTIC INSTALLER HANSON EXCAVATION LLC Phone: 360-239-6792 Address: 86 E BANJO LANE SHELTON, WA 98584 Site Address: 41 E Vine Maple Ct Primary Parcel Number: 321045200119 Permit Description: New SFR-3EIR Nuwater+Subsurface Drip Permit Submitted Date: 03/20/2025 Permit Issued Date: 03/27/2025 Issued By: Jeff Wilmoth Current Permit Fees Paid: $555.00 (.dddbnel I.may r w.,, upon bsaw.n dayrbm). Permit Expiration Dale: 03/24/2028 (based nn deb PflrePM ) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backffll of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.gov/health/environmentallonsiteloss-inspection-mquest.php or call: 360.427-9670,extension 400. �JOFFICIAL USE ONLY A� DATEIIILFrvFO o9•Zo ' LOZ✓ MASON COUNTY MD N B MCD DBY o m ® COMMUNITY SERVICES Sj�'rj _ z 0 OuNNNe�N,)Ee,ry,R"„R).HEZIIN/EITMmRImnMI HeaIM1 SWG od92 2va5 o s w:aa,.smz . s.se,,.mwo Z (a ON-SITE SEWAGE SYSTEM APPLICATION m m PHONE r APPLICANT (360) 898-0055 a c AB Fine Homes CD s MAILING ADDRESS-STREET CITY STATE ZIP CODE (� ion `Il,p flOG92 M 871 E Beach Dr av\ o YYf1 JOJ SITEADOPE58 STREET CITY LP CODE Union WA 98592 � � w 41 E Vine Maple Ct VVV NAME OF DESIGNER Q ' j PHONE 898-2255 ro Arrow Septic Designs, Inc (360) PHONE :4 NAME on EN (360) 239-6792 < Hanson Excavating rn pEDAlIt1YPE(Wed wl .1 C1 DRINNINO VIATER SCURGE ®RESIDENTIALOSS BCOMMUNITYOSS 5COMMERCIALOSS PRIVATE INDIVIDUAL V,ELL I]j PRIVATETWO-PARTY WELL IZ IA TY ®PUBUC TER SSTEM EJUNM CONSTRUCTION IUPGRADES REPAIR/REPLACEMENT OTHER (13SURFACIGS GEE [3EISTNGFAILURO SHORELINE N I rTJ L SUBMITTALS LOT SIZE 0 I N cc IY ®DESIGN FORM(REQUIRED) SEPTIC DESIGN(REQUIRED) BEDROOMS 36R .38 acres x to EDMIRIVER(S)(IF APPLICABLE) pIRECTI0NST08REIN0 SITE CONDI110NS'.(ee 1"cketl CeNl Go out E McReavy Rd toward Union and turn (R) onto E Manzanita Dr. into the Alderbrook neighborhood, Turn (R) onto E Jack Pine Ln., Turn (L) onto E Vine Maple Ln, turn (L) onto r E Vine Maple Ct, Destination at end of cul-de-sac, Yellow sign: "41 E Vine Maple Ct". o S?EW/BT BEftADOFL PROM MANIfO'eDANDTBSTNOLE5 NU5T 8Efl.A0GED IMNITEST NOLFN1lAMERS. I Do OFFICIAL USE ONLY BELOW THIS LINE UPGRADE I FAILURE SOURCE W HVP PS IB"pCfeel ❑VOLUNTARY ❑MAINTENANCEIPUMPING El BUILDING PERMIT HOME SALE QCOMPIAINT ❑OTHER: COMMEMTSICONDrtICNB INSPECTOR SOIL LOGS '7 q LS ILU 23 c5 RECORD DRAWNG AND INSTALLATION REPORT SOIL CODES: REQUIRED FOR FIN VI.APPROVAL. V=VENT G=GFAV£LLY 5•SAND L=LOAM Si=61A C=GION XPIAL EXTREMELY R•RWTS "TIONAPPRWEN ISSUED BY DATE DATE APPLICATION EXPIW.TIpN MTE 111` ) G RSIGNATURE q L7 f T R MAYBE REVISED 111/1A15 SCANNED AND AVAILABLE FOR PUBLIC VIEW OH THE MASON COUNTY WEBSITE DESIGN FORM—PAGE ONE Assessor's Parcel Number: 3 2 1 0 4 — 5 2 — 0 0 1 1 9 A design will be reviewed when 3 copies of each of the following are submitted: •Completed design form that has been signed and dared. v Scaled layout sketch,including all applicable items on checklist •Scaled plot plan,including all applicable items on checklist. I Cross-section sketch,including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site.hTnximnm paper sire: 11"XI7" PARCEL IDENTIFICATION Permit Number SWG 2015-_( (.3)a2_ Designer's Name: Arrow Septic Designs, Inc - AB Fine Homes Designer's Phone Number: (360)898-2255 Applicant's Names gn ---- - Mailing Address: 871 E Beach Dr Designer's Address: 171 E Vuecrest Dr Union WA 96592 Union, WA 98592 Ci State Zi City State Zip IGN.PARAMETERS Treatment Device ❑Glendon Worker ❑Sand Filter ❑Mound ❑Said Lined Grainfield ❑Recirculating Filter.Type: Gi(Aembic Unit Make/Model NUWatef BNR-500 ❑ Disinfection Unit Makeiklodel Other: 500 Gal Pre-Trash Tank Drainfield Type ❑Gravity Rf Pressure ❑Trench ❑ Bed Rf Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 Schedule/Class Netafim Drip Daily Flow:Operating Capacity 270 spd Length 28.5 x 4 =114 ft Daily Flow: Design Flow 360 gpd Diameter .66 in Septic Tank Capacity NuWater BNR-500 gal Number 4 Receiving Soil Type(1-6) 4 Separation 1.5 ft Receiving Soil Appl.Rate .6 gpd/ft` Orifices Required Primary Area 675 tiz Total Number of Orifices 456 Designed Primary Area 684 ft' Diameter .42 gal/hr emitter in Designed Reserve Area 900 ft' Spacing 12 in Trench/Bed Width - ft Manifold TrenclnBed Length 456 ft Schedule/Class 40 Elevation Measurements Length header R Original Drainfield Area Slope 12 % Diameter 1 in New Slope,If Altered 12 % Preferred manifold configuration used? G(Yes ❑No Depth of Excavation Up-=lare 6.10 in Transport Pipe from Original Grade porn-slope 6-10 in Schedule./Class 40 Designed Vertical Separation 12+ in Length 120 ft Gmvelless Chambers Required? 0 Yes idNo 0 Optional Diameter 1 in Pump Required? Ed Yes ❑No Dosing and Pump Chamber Pump/Siphon Specifications Number ofdoses/day 12 Difference in Elevation Between Pump Shutoff and Uppermost Dose quantity 30 gal Orifice 12 ft Chamber Capacity 1,000 gal Uppermost Orifice Ilf Higher ❑Lower than Pump Shutoff Pump controls: Please check those required. Capacity C Total Pressure Head 9.6 gpm 9-rimer G(Elapse Meter GTEvent Counter Calculated Total Pressure Head 145.2 It Ti o I ,Pump off 1.84 hr Comments rrnVVGxjj MAR 2 7 2025 AS N44ENIVIRRIMPIR - TM l b�Iq JBw DESIGN FORM—PAGE TWO Assessor's Parcel Number:3 2 t 0 4 -- 5 2 -- 0� 0� . Permit Number. SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch 16 Test hole locations 9f Drainfield orientation and layout Reference depth from original grade: 9 Soil logs 66 Trench/bed dimensions and Rf Septic tank 66 Property lines critical distances within layout 66 Drainfield cover ❑ Existingand proposed wells fit D-Box/Valve box locations P ro P Reference depth from original grade within 100 ft of property 6f Septic tank/pump chamber and restrictive strata: m Measurements to cuts,banks.and locations 9 Laterals,trench/bed,top and surface water and critical areas ❑ Observation port location bottom ❑ Location and orientation of 69 Clean-out location ❑ Curtain drain collector curtain drain and all absorption R1 Manifold placement ❑ Sand augmentation components Q1 Orifice placement Other cross-section detail: 19 Location and dimension of It Lateral placement with distance ❑ Observation ports/clean-outs primary system and reserve area to edge of bed 21 Buildings Other Information 66 Audible/visual a1A referenced Yes No 66 Direction of slope indicator Rf Scale of dmwi !' m on scale Ef ❑ Design staked out Ed Waterlines bar ❑ E6 Recorded Notices attached lid Roads,easements,driveways, ❑ 61 Waiver(s)attached parking " lit ❑ Pump curve attached 621 North arrow and scale drawing ❑ 19 Evaluation of failure shown on wale bar 51. Msa Non-residential justification uu JOr ❑ 56 Waste strength ❑ Ed Flow DESIG A ' AL fhe undersigned designer must be notitied byinstaller at time of installation EfYes ❑ No 4D l:A,0 � zrzo-t,&- Sighature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local - 'te regulations: E it rental Health Specialist Date CAUTION: DESIGN APP VAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. Z ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: 3 -Z ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. Updated Daze: 12/7/2015 270Z4 P EMI 4VI,i I,,,��Lf116�1tl31� IVMI Co pii BLAB ol- 4R BOUNDARY UNE ADJUSTMENT MAP Cd=^Gelsww EXHIBIT sw1e:1 �ga 19303 FremontArm3eN PORTIONS OFF7 Dow:�9W Swan,WA 98133 �DBRBROOKGOLFANDYAt7�➢.U�IIY`ATHS Nat ALDYRBROOK GOLF AND YAC�BT.CLUB FgFF."'PPPATES No.1 LEGEND PROPOSED LOT LINE PLATTED LOT LINE TO BE •.;.••;:.'. .' � , '•..,. .':•Ill•:.:::;:;: •::':. : '': V�/ :•r' :•:•:•:' aye 4r•-.•. . L31m13K'.' ' ' P A I• Ib PARCEL 113 ttl13 116 "4 I PARR A 25 ' � `t / �.qy'4 i� PARCEL 25 ar I n d i ITT44 • / / ''jj..���� �' i PAMEL 22 •• . . . Q�Yf� ••N,•,�33916 •• '::'.; 119 '3�'aoiv.. .;.•... .;.• PARCEL 21 sl t or -,•.•'.:.. •'. y PARCEL I9 1 ..y J . r ':'�136i:•::: 1 :127•• Daft AWm3'M /G2. Pmficn3o1'section9ena of S.6.4,T..,Wp 21 North Range 3 Wo,W,M.,ie Muoa County,Wa66iegtoo. 2eylq � 0 �,t20 �� 285x24 PR,M�Ry l ;LcpE ��7RtP V.F. wiTh sq{-h 0-e � / �eseYve Dr, A ­T9Co" / Dp P 2q5 VJa+er v Q 'TEST I+OIE 'T� =tk-4 : 2'1" GSI.+J,(RZ-storts { Fre iay1 xrj: 2� GSL s I f V FLOtticd ffc.Ke+S [0 �\ i 38R d CoMP/r^* a J N 5100342 P MULR JOY JOHNSON';' J o- ' 1C n 3_ to-t,5 �t.aT Pu�1J xe�. R6 T-k.ES Ol Audio-VisualAlerm 32t o� 52-6 l l O2 Cleanout �1 V 10 E t-1 APLF G 0 u RT O 500 Gallon Pre-Trash Tank v N t s rnit W A . I O E2 2 O4 NuWater BNR-500 Pretreatment Tank App R O V E OS 1,000 Gallon Pump Chamber MAR 2 7 2025 U 06 Subsurface Drip System Headworks MASON COUNTY 1B H ENVjpONMEKIkL HEALT 3 oFlq Subsurface Drip System Calculations&Specifications AB Fine Homes Parcel#3210452-00119 41 E Vine Maple Ct Union,WA 98692 Number of Bedrooms 3.00 Length of Supply Lines Operating Flow 270.00 From Header(loop system) Design Flow 360.00 let# ft. Soil Type 4.00 1 supply 2 Soil Ap. Rate 0.60 2 supply 10 Required Square Footage 675.00 3 supply 18 Designed Square Footage 684.00 4 supply 26 Lateral Length(looped) 114.00 ft. Number of Laterals(looped) 4.00 as Dripline Spacing 1.50 fL i return 10 Emitter Spacing 1.00 ft. 2 return 18 3 return 26 Dripline Length Required 450.00 Lf. 4 return 34 Dripline Length Designed 456.00 Lf. Emitters Required 450.00 ea. Emitters Designed 456.00 ea. Let total 144 Header 6 Transport 120 Emitter Flow Rate 0.42 gal/hr each emitter Return 120 Design Flow Rate(#emitters x.42) 191.52 gal/hr. Total 390 Flow Rate(gal/hr/60 min) 3.19 gpm Minimum Doses/Day 12.00 On Time(total per day) 112.78 min/day On Time(per Dose) 9.40 min/dose �c �fr• Off Time between doses 1.84 hours ;�y' s'ooaae 2' ",.,A JOY JOHNSON rxrinrs , 3- Z's APPROVE MAR 2 7 2025 MASON COUNTY ENVIRONMEN'AL NEALTI JBW geY19 €E€- �(E�g��& d: x 4..�q:'.y 5=�s aai..eq. E( 3$b b y G4 ,${ ? S Y 1, m Pn-$SY9l$! ffing €Egg w y�2 � $a$ $; bs ;ag 4ivii o8yF2 g y$ "E%1¢3T AE$yig In d HH'S as EpB SS' 8g�g d gE$a6E: O o '� EF 'sP s cs`s'SeF=l E 0 a � a p1 s §: ®0 a $ Is!!§e o § £ ! a Icag p y 3a ga Z T } § I$. . gym V E MAR 2 7 2025 MASON COUNTY ENVIRONMENTAL HEATH 5 oe lq JBW subsurface Drip Looped Dlstnbuticn Drainfield With Supply& Retum Manifolds 5G¢9.P. t' $ to Lmo Q Ca+.�.ac.Szan o S to tS >A -s- s � y S1UY JO ' IC ISE JOY MM'. LA l'N IGNEIi" 3- Zn—LS Notes: • Instail Dripper lines as level as possible across the wntourgrade • Divert all surface wateraway from the drainfleld area • AirNaaJum Relief valves are to be installed at highest point in dminfleld APPROVE MAR 17 2025 MASON COUNTv ENViRCNMENTAL HEATH bel l`1 JBW SuWwfaee Drip System-Recommended Standards and Giddm Effective Dam: July 1,2007 Figure 4. Looped Drip Distribution Field with Supply and Return Manifolds DRAINFIELD SECTION xEs r.ua� .w a sa+v � n40� TOP OF SLOPE nnerca vxxs m 1$6 {EiPq RL4i l➢GS _ _ - _ n aitVY fir-f'1fP�FR \ �— Kiv vYt1Ei TP RM' -� ���11�, Ip6�f111 661 QM CIA CpPQ6P2i pRinb . (ttMA LG Zdtl (/)/I RExp C6PVPitY1---�—+ Lj(1PE➢ ➢I5TRIBUTIIIN F� ens xmsa +) aa'r4t oawau uas (AS anII as VWSRsI ttvu t/nx nuns coxroua5. /^s aan�u �ee� 'ax-sjat,.u-s m a�vne,*�so�w vne g ; CnX C Q,�.IPjiySl APPROVE MAR 21 2025 MASON COUNTY ENVIRONMENTAL HEALTH DOH Publication#337-015 J BWbp 37 df 51t �mm au. s x� tsnucoc 1ii9..0/IfV IWdcd�c lbmfr KYtS�iv ]SAJLJVS liY[ibx 3SW.XC NeWf=Tech Filter Chats. I Flea lrhb'• /%/Nye '� 39 PSI ,e✓. j r� � TbTN*4. flan Add Aw master Ndas for PbodTo sold ,.:-�• -Neese-.; .»• ;:%.� i i i f j�� •�i� is/r���i.:�easiar i HD Fewl•"Cwtmooa.Fl""h Hrdwerla I The main compotimEa of the heedwazks are: I"Tech Filter APPROVE MAR 17 2025 MASON COUNTY ENVIRONMENTAL HEALTH JBW Sub=fa Drip Syst®s-Recoaa S=dl* dG1IIamu Eff=t, Date' tiny 120n7 F%ure 7. Air/Va =Rdief Valve in Valve Box with Gravel Sump I i Y4VEBF �.� �� DAVPGUa(8� p6i/A6A?IfSS ..� � VYIEWWn9E ?T^11PX^T(.7 iWVDi61)E I uRauS 1?S9l O1RiE � 1 .in I PArRaV69nP •—� C.CPRGMDR}}f'ia - APPROVE ® MAR 2 7 2o25 p ae DOH Publication T337-015 MASON COUNTY ENVIRONMENTAL"t2Y,LTH3y Of52 Jew ef-- 19 H D Fowler Company Quality Performance, Long-Life and Reliable onsite Effluent Control Applications: onsite wastewater drip dispersal systems Reuse applications including municipally treated effluent designated for imiga4on and other disinfected and ron-disinfected water sou.nCeS In a treatment system such as an intermittent sand fitter or mound system Rainwater harvesting systems Greywater systems Wherever effective removal of debris is required Typically installed downstream of treatment process when used with onsite effluent Can be used with domestic strength septic tank effluent with proper design and The PUHFJ+DWORKS4 Comes operation Standard in a 24"Riser Features&Benefits: Continuous forward flushing of drippedine keeps piping networks clear of debris Ready-to-install for was of installation Comes standard in a 24"riser • Simply attach system piping to headworks Car.be used with demand or timed dosing No electrical components to wire Compact s¢e fits in 24"riser Centralized manual controls make flow setting easy Manual flow control of flushing velocity allows for infinite setting control All components easily accessible for easy maintenance • Union fittings for easy assembly and disassembly of mmponerrts Filter. Highly effective multiple disc ring design captures and holds more debris than screen filters • Low fiction loss keeps system costs down Rings are easily removed for fast cleaning without the need for scrubbing • Greater holding capacity of the rings vs.screen filters mean less frequent damning Color�coded disc rings make identification of mesh rating fast and easy Filter ring sets are easily replaced to meet system mesh/mitxon requirements • Fliter sme,oan. t,Inaeabed to ""Long'w Out r plumbing Water Meter. • Designed for reclaimed waterfor long life • Easy to read dial AAPPROVE MAR 2 7 2o25 MASON COUNTY ENVIRONMENTAL HEALTH Jaw to oP 19 Specifications: Fitter • Mesh: 120 mesh(130 micron) • Filter Body and Covar.Reinforced Polyamide • Disc Rings: Polypropylene • O-Rings and Seals: N'Rrile&EPDM • Clamps,Spring and Botts:Stainless Steel • Temperature Range:-40•-160•F(40•-70•C) Maximum Pressure: 140 psi (9.66 bar) Meter. %"x Y•"brass • Analog dial • Gauges: • 0.100 psi range (0-6.9 bar) • 2W,glycerin filled Wks pressure gauges Flow Range:2-20 GPM (7.6-76 liters/minute) • Maximum Pressure: 60 psi(4.1 bar) • Length:24" (61 cm) Width:24'(61 cm) Depth:13"(33 an) • inlet/Outlet Pipe&Diameter 1"Sch40 PVC Application Recommendations: • Wherever automatic flushing of a trip network is desired • Any domestic or commercial application Ordering Information: Model Number Description Flow Range PUHFADWORKS4 Continuous Flush Headwrorks 2-20 GPM �nor•w m...r i e.— a�'F Corporate Headquarters 13"0 S.E.30th Saes BdU.,WA 98005 Phone: (435)746 O Fax(425)641-8885 b fowler com �I a'FlR Netafim Drip/Micro Irrigation Solutions Wastewater Division Bioline® Pressure Compensating Dripline Technical Specifications • Dripper flow rates: 0.4 0.6 or 0.9 GPH • Dripper spacings:W 18"or 24"dripper spacings and blank tubing • Pressure compensation range: 7 to 58 psi(stainless steel clamps recommended above 50 psi) • Maximum recommended system pressure: 50 psi • Tubing diameter: 0.66" OD, 0.56"ID • Tubing color. Purple color indicates non-potable • Coil lengths: 500' or 1,000' (Blank tubing in 250') • Recommended filtration: 120 mesh • Bending radius: T' • UV resistant • Tubing material: Linear low-density polyethylene EXPLODED VIEW Of BIOUNE DRIPPER Bottom View Top View Large inlet filtration area (bottan of dripper) Dripper outlet (top of dripper) mo Physical barrier separates where water leaves the dripper from Chemical-resistant where it leaves the tubing. molded silicon I�q diaphragm Drippers Top View Fop of dripper'turned over) TurmNel wide flow path �re M¢lNrv+w.nel�fmwe.mm/wasMxata�POEuc6ltiainam'iNOMlntrbcn lzor%ly DRIPPER FLOW RATE VS. PRESSURE 1.0 09 3 0.4 W 113 0.1 ? - - - - - 1 - 0 10 30 30 49 58 58 PRESSURE(psil Between 0 end 7 psi,the dripper functions as a turbulent flow emitter,ensuri g that the nominal design flow is not exceeded at system start-up. Moline Dripper Operation Bioline®dripline drippers are pressure compensating- delivering the water uniformly into the soil for further treatment or for reuse by the landscape. These unique drippers allow the tubing to be installed on flat topography or steep slopes. Bioline drippers are protected against microbial slime. Each dripper is impregnated with an antimicrobial agent to resist biological build-up. Netafim drippers are continuously self-cleaning during operation, not just at the beginning and end of a cycle. The result is dependable, clog-free operation,year after year. vs !mplwww.,e�msarmuwmunaa/o.oaucwlsalno-arlaceNxi-�ecn t3 .� t9 I @@IwIW Puna PEaaORmANCEwpvE a- p11MP PpiFGPI+AHCEwRYE k'I,C PUMP PERFORMANCE WRVS • 10 GPM it 19 GPM 11N•NK0EOMWGE i14-mPTDISCHARGE ry•NP7 DISCHARGE m tp � LIKKR�ME • 3i1 Ip.F61FG" ® m +W >m fi LO MW i 1 �W NM.Pi:Yt I Q 'A y 1 V.tR G E W ID +RICE WIFE : GO GSW f reEGE W SB + EF ew m SSj :A 9 y y W F 1F a w + tR W1 WE°F d0 W A 16 I I p I I I 0 a 5 ;j 5 I ID 30 MIPW • + 1e GiLCM$ N+ M i 0 G iE W 0 H Ei L'f3 00 GG 5L 30 'm G:I •� xwrt 0+5c:3 hQ'lPOi lsx:TE O14GtG 01 w x m PWI BI:n� XP 2ep v1eGe A+rcb Sp° Hem 0 9)30U0.5 1rz its I 120 6 22d6• m w OdUAxO IL 160 6 223 9SGON7 12 1115 11 1120 8 alp pAwPEavlxnE Rlsocs SDpm 12 im 11 16D 8 Tw 3'G 23] 80 :2 2315n6• �W 1 C PWPPERFORMANCECURYE aM und+ s.v vmye vreGE x+w spN yM'G 35GPM IL 5B.=6 1¢ ills 1 120 5 21.15".6• �E`yi'`s m 7NPf DISCHARGE M ui S(({I� 12 233 i v"0 5 21�1516' 1 N xP.SS.EGE IA 5,.0 7 39 12M 11 190 I 26V'.6' aA-, 1°a a- AID0.3A 23; +. 98 9 2S1R• ap IMi.isNf£ a PNN1mbr HP Ydm9e Pew Amps S[gM X.Oa 4 Ito smlJY1S 12 1115 11 120 G 21dae' OJ ]4 xp-35TGE a 592� 112 I 2i] 1 60 6 2'3113 � i !M (7 6032IXG] 3-a a 1 9.0 6 2xd116l N 5m1m 1 1230 11 98 7 267115l P 1 tRxP�3 E a�tLD� 1.1¢ 2L 1 131 10 3 le w [NOMTE:55 G3 65 1° PEII Uim1• Np •Ay,¢9¢ PttESe F!1le SE4E° iH4'G d0 elaovailable f2^. 2 1S'9' eae3a a"'t'Cta%s 12 Zfl +. 60 2 1S79• .See FM2091 1 60 3 p1N consult Zoellermucal Sortie 1a s 5o as m IN Ca 5033WY 1 vJC 1 98 c 2 b12 230 rtmmt umRaa m w 1m 1M roc f{DNPERYHVIE 015Mt ALL ZOMLGR OMMM MQPUQl YUW CC INLALLCDIN--0ORDANOG YIITH PUUMOINO AHO HULTF mmM fiCNT'eOmm plsVi6uted By: kzpp. 1-800-928-PUMP www.zoeller.com ®Gcpylight 2007 Zoeller Co.All rights reserved. t4o19 yr�-sia xe +W .. .3W366'LB9 : :Xtl38�YL89 �Ei :3NOMd. .Q Ny�p 9U988 tlM'pNtipLF�3}J.1Y8180C MI9"O"a JN�2i33Nl:1N3 >13 6 6'�Lb Sa3 r 4 s �e RA ISEaM = 1 O L3 g 5^ ;raj 11q Mal I It sP R qq 1 'aSj1ID$A a E �+55 lit OgigR HIP, ��$�� �# x x c L50�1°J 4-T � I :'PVC(fY% S d/81.KHtl— 6 T� MSLLOGE � � I TPVL � 'SRASM�n111� � ' �aa:wceavaumanu:sws a�rrtwnMum- .m MY.ars �IMIM� aowcvac-:asvenu_'++s waaDTrdOl�:adaaat,are Mde\eWe � wl w I � I a' I mpim mmM nuevaromerra: e j '� aimdcra:,c+n +mare+ ors�amncry sarm wsl s�S+L MIeTALLA.W 6151P8KFWrR 1)Ecdvate t,*h*.e vamsweft tt fact e,9e'tw bnkaa4 m z)ner�ernaeas�.�Tarm+edes+Lsk�e __ I '.$)tW$at 61 a!ft cf? 2 R'-9xy l t rciE R»L> I x X1011et aA SE6 i i laIK a7 as vxa�9+a.sn.!arvae ap�.a m+e+a it I (�j�dp]Yad of bteJe fLe�pL Lf Coj. 1 5/NCI[RC CeSyDbR&affi rSsmibeddpY,L+Mbi I if a'd ! I I 71�Go,+ei,oMtla�&aretJY ac�fibrAth rffire i 71.alMilt I: S'� iisee®I dole watpdtat I' __J. �FYO Fddr>k anamaa.c's ymRen'S,rtae ' ______ —� mlabw4l� ^=LL „� AEROBIC TREATM P PENT TANK DETAIL FOR Nu WATER BNR-500 TREATMENT UNIT ENVIRO-FLO, INC. 3/p1/12 �s�+I PA.3pXg2f161,Roxms:k6�2II MAR 2 7 2025 MASON COUNTY ENVIRONMENTAL _i, 16 oY I% JBW �Water 1 PARTS UST NuWater NR Assembly Diagram A.MK FWASWM Y.PpLT DiFFiFYR B�R(a ILWWJMSPWC[AIPSR7 R*•PW(S a/Issrbm QXrsVMADAPTORXIMM M 0.11"W D f?AIDzir WfAMPIDR F'iT aeNtFw xocs r E TSRgT%t?�MIDFw<+fS Qt?PK FIPCr WbSA M F lcw Ejwm R TPVC PRE(6t'M5TNL10C. GT%1•%if S.tPK. SY% AILSM .4 I- 'asow Rl T.+T gV�E®at6wwTC+r�4rW 1.2,XrWIWID u.�rrErnrzTz vrrRAEFo a rsv%r�rt*TQ v.,.r sae rvwimm K rPA:CHM W.zCLVPt5R(6+'1NSIALL80 . L rCMWM lam'MTAUEM P w MAR 2 l 2025 —MASON COUNTY ENVIRONMENTAL HEALTH JBW SECURED LICrirtNOASTWff MAL THREAOED.1 u•OUrEM ACCESS RMER SERVICE - GRADE VALVE' FROOEVIIC =- TooRAPrww .TANK ONFAENCYSTORAGE A VALVE oN NKNL WATER ALA E LEVEL I.. NORMLTNEU off LEVEL wommovoum PtOAU10�r MR FLOAT NOIMINR ENCLOSED PLUM .AIEOR VALVE• ..... EEOUBLTEMROYD•_.... ._ - �. _ Is- SUSNOMMLE EE01rORS <='N I:11 CLVIMlNOAL PUMP YPICALI 'AE NEmfO Septic Tanks must meet standards required by WA�C chapters 272C and FIGURE.2 manufacturer must be on Dept of Health list of registered se a tanks- WA nMPaMimiu16337-= - Pop 35 of65 7 avwtu Septic Deji9w ,(. •.. ', r1 NuWater BNR Pretreatment H .,' • 51_03pe '.. ` INSTALLATION&MAINTENANCE PAULA py pMNSON'',� Subsurface Drip Distribution Systems 'CC'iSp tsiGNE '• 1. Install subsurface drip tubing level with contour of the ground. �- 2. Install drainfleld during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 3. Install audio/visual high-water level alarm. Redundant off switch not required. 4. Install vacuum relief valve on both the supply and return header manifolds. These must be installed at the high point in the distribution field and include a gravel sump. 5. Supply and return header manifolds and feeder lines should be installed at a higher elevation than drip tubing,or an earth damn should be created to prevent drainback. 6. Tanks must have risers to the surface as required by Mason County to ensure easy access for future operation and maintenance. 7. Supply and Return Header Manifolds,Headworks and vacuum relief valves must be in boxes accessible from the surface for future operation and maintenance. 8. Ensure 6"minimum cover over the drip irrigation tubing. 9. Install return line from headworks back into the pump chamber. 10.Encase all water lines within 10' of drainfield and under any driveway/parking areas. 11.Divert all storm water runoff and house downspouts away from on-site sewage system. 12.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the dtainfreld and reserve area. 13.No vehicular traffic over drainfield area. 14.Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 15. All materials and workmanship must meet County and State regulations. 16. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 17.All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. I S.All transport lines under driveways or parking areas must be encased to prevent crushing. 19. Homeowner is responsible for all property lines. 20. The preferable cover planting for subsurface drip is turf or grass. The homeowner should ensure no roto-tilling or digging in the area of the drip field to prevent damage to the drip tubing. Also, invasive plant species should not be allowed. 21.Note to installer: The voltage of the NuWater Panel is to match the voltage of the pump. 22. Please Note: When you begin using your septic system, contact your septic installer to discuss setting up a schedule for your required Operation&Maintenance on your NuWater pretreatment system. APPRO VE MAR 27 1 9 MASON COINTYENVIRONMENigI HEALTHJaw