Loading...
HomeMy WebLinkAboutCOM2023-00070 Remove Launch, Replace Docks, Replace Piles - COM Inspections - 4/9/2025 MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 II, COMMUNITY SERVICES SHELTON:360427-9670,EXT 352 BELFAIR:360-275-4467,EXT 352 Building,Planning,Environmental Health,Community Health ELMA:360482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.usicommunity-services/bid-inspection p Permit Number COM2023-00070 Date Issued 08/18/2023 Issued 424 Project REMOVE EXISTING BOAT LAUNCH,REPLACE WITH 901 SQ FT,REPLACE A,B&C DOC S T REDUCTION AND GRADING,AND REMOVE 17 PILES AND REPLACE WITH 19 Site Address 261 E Shore Dr Applicant PARADISE SERVICE ASSOCIATES Contractor LAKESHORE CONSTRUCTION Contractor Phone 360-801-4597 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW COMMERCIAL PERMIT Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION, FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. "THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building •2 'bEe­ Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other INSPECTION RESULTS Pagel MASON COUNTY Department of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584 Permit Assistance Center,Building,Ptannaig (360)427-9670 ext. 352 Application# COM2023-00070 Application Type NEW COMMERCIAL PERMIT Owner PARADISE SERVICE ASSOCIATES Parcel# 221085200900 Site Address 261 E Shore Dr Grapeview, WA 98546 Inspector Inspection Type Date Status Comments 3-5-25 DEC !'PROVIDE PILE DRIVING REPORT FROM PER SPECIAL INSPECTION AGREEMENT Drew Carlson BLD-FINAL INSPECTION 03/05/2025 FAIL --INSTALL (5) 2A10BC FIRE EXTINGUISHERS ON DOCKS PER PLAN --,,MIDDLE SECTION DOCK 3RD FLOAT ON LEFT IS MISSING JAM NUTS TAKE PICTURES AND EMAIL ALL DOCUMENTS. INCLUDE WITH EMAIL PERMIT#, NAME ON PERMIT ADDRESS DREWC@MASONCOUNTYWA.GOV a w i '30fJJ G2CO-IC> 6vtd 2�2 eiz CO V �A rir w rr rr© na ,etr rasa mnf ® :M O twrfarwln 1 UTYas�ww K•�w...a 1/MOf wwt0111M1 tPi Apy« �.. t11'wK rll tA1� M lM WirOM q wMw►gn ..rrw/l wt !te w ,do uu.rn w�v.n�wnr�.LLur Ye If `�y.•p &rDr.r wr A OOp drat ,f v ut ® O ® rl ! . V TION - ra• .� •o uv Lakeshore Construction Pile Driving Records 2,000 LB hammer and 600Lb follower block. 20 Ft Drop height Client : Pa, _T Pile Description : ICY 6"OxY. C."j a Pile No (ref) Penetration (ft) Cut-off(ft) Amount of blows Pile use —g - - - -- 2 0 Lakeshore Construction Pile Driving Records 2,000 LB hammer and 600Lb follower block. 10 Ft Drop height Client : Pile Descri tion : 0't Pile No (ref) Penetration (ft) Cut-off(ft) Amount of blows Pile use n O r OLL _.. Z' V t T t I�i c-��t t ` yti_ re nt �"��� �wyuw�w mti�wttw� gaY.r y�.,�s�Ma xw=-wS r W,4 r MAE As / a w ' •�.• �.�� .att�rwrwT ' was an�wr•w � � �Ila[Y101 ttt/�MtMOA�.O - N iA ATT rM J. Lakeshore Construction Pile Driving Records 2,000 LB hammer and 600Lb follower block. 10 Ft Drop height Client - Pile Description : 10" Eooxv Pile No (ref) Penetration (ft) Cut-off(ft) Amount of blows Pile use ND 3' 2 n � 1ar�wrw ro iw O1�w/IO11r4�1 iY+�ww ww w•w wwrr wale w+ww�w� rrcw�y+w�► x�� •air wt ///```rwo.w•m wor�roui rwinr�an. II1 Ir MI <OIIL VNMM� wao NIOM1f K7M1� M � `.etr oYo� •�JrItY40Rl M. s � •r �� rr 4 Mason County Mason County - Division of Community Development 615 W. Alder St. IV' Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FREPLACE 3-00070 NEW COMMERCIAL PERMIT DESCRIPTION: REMOVE EXISTING BOAT LAUNCH, ISSUED: 08/18/2023 WITH 901 SQ FT, REPLACE A,B& C DOCKS WITH 224 SQ TION AND GRADING, AND REMOVE 17 PILES AND EXPIRES: 02/14/2024 WITH 19 ESS: 261 E SHORE DR GRAPEVIEW PARCEL: 221085200900 APPLICANT: PARADISE SERVICE ASSOCIATES OWNER: PARADISE SERVICE ASSOCIATES 261 E SHORE DR 261 E SHORE DR GRAPEVIEW, WA 98546 GRAPEVIEW,WA 98546 360-870-7999 GENERAL CONTRACTOR'S LICENSE: LAKESHORE CONSTRUCTION License: LAKESC`155JA PO BOX 1058 Expires: 04/20/2025 3800 NE NORTH SHORE RD BELFAIR, WA 98528 360-801-4597 VALUATIONS: FEES: Paid Due U VB Utility, miscellaneous 188.00 $20,000.00 State Fee-Commercial $25.00 $0.00 Plan Check Fee $219.68 $0.00 Planning Commercial Review $380.00 $0.00 Fee IFC Plan Check Fee $109.84 $0.00 Technology Surcharge $11.15 $0.00 Building Permit Fee $337.97 $0.00 Total: $20,000.00 Totals : $1,083.64 $0.00 REQUIRED INSPECTIONS Footing Inspection BLD-Final Inspection 3rd Party Inspection Report CONDITIONS Printed by:Amber Selby on:08/18/2023 02:08 PM Page 1 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW COMMERCIAL PERMIT COM2023-00070 * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at (206)357-2620, ext. 630. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance contact the Mason County Public Works Department prior to construction at Ext 450 Printed by:Amber Selby on:08/18/2023 02:08 PM Page 2 of 3 Mason County 10 Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW COMMERCIAL PERMIT COM2023-00070 All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Comply with conditions of SHX2022-00024 and comments from SEP2020-00002 * Archaeological or historical resources, such as ruins, sites, buildings, artifacts, fossils, or other objects of antiquity that may have significance from an historical or scientific standpoint, which may be encountered by the developer/contractor, shall not be further disturbed. If the developer/contractor encounters any such artifacts, he/she shall immediately stop work and notify Mason County and the Washington State Department of Archaeology and Historic Preservation. Failure to do so may result in civil penalties. * A Hydraulic Project Approval from the Washington State Department of Fish and Wildlife must be granted prior to commencing work. wdfw.wa.gov * All construction debris must be removed from the site after project completion to an approved location. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of aquatic environments. * An inspection performed by a representative of the geologist, their authorized representative, or engineer of record, shall be completed on-site prior to the footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations. In addition a final inspection report, prepared by a representative of the geologist, their authorized representative, or engineer of record shall be required to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations. Reports shall be submitted to the Mason County Building Dept., 615 W Alder St, Shelton, WA 98584, prior to the footing and final inspections and available for inspection. * Owner shall provide pile drivers report on all piles. Any pile supporting structure and over 10' in height from floor of body of water shall require engineered design and special inspection. Engineer of record (or certified special inspector)shall provide verification at time of inspection that piles are driven to point of refusal and/or installed per design. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not The gran ' a permit does not presume to give authority to violate or cancel the proviW_gf'finy ther sta /lo I law regulating construction or the performance of construction. Issued 13 U Q Contractor or Authorized Agen Date: a �� Printed by:Amber Selby on:08/18/2023 02:08 PM Page 3 of 3