HomeMy WebLinkAboutBLD94-01050 Final Mobile Home and Deck - BLD Permit / Conditions - 3/31/1995 MASON COUNTY
Mason County Bldg. III 426 W, Cedar
P.O. Box 186 Shelton, Washington 98584
13 U 1 t_ D I t4 01 PERM 1 -T FOR INSPECTIONS CALL 427--9670
BETWEEN 5pm AND Sam 427-7262
BLD94-1050 PARCEL 22232.54491O7O PLAT : DIV . Bt.K : LOT :
JOB ADDRESS : NE 1561 MISSION CREEK RD BELFAIR
OWNER : WESTBOUND CONCEPTS 895--4336
CONTRACTOR : WESTBOUND CONCEPTS 895 -4336
LEGAL : TN 7 OF 1112 SE SE LOT 1 OF SP #915 FS 44614:2 BK 157
..asaei:--:x•c.�a_^as:r.;.axar-�::�a..,* --•,�,•T--.•• ..mean.- ::::ms:^cc s.
CLASS OF WORK . . :NEW BEDR : 3 BATH : 2 �IYPE ANOINT BY DATE RECEIPT TYPE AMOUNT BY DATE RECEIPT
TYPE OF USE . . . . :MH STORIES . . . . . . . .. 1
OCCUP . GROUP . - 7 BLDG . HEIGHT . . : 0 .Oft NHOF $ 100.00 NJP 12109194 37946
TYPE OF CONST . . :? FIREPLACES . . . . ; 0 STFE 1 4.51 NJP 12169194 37946
6CCUP . LOAD . . . c 0 WOODSTOVES . . . . : 0 RLC 1 46.116 NJP 1216904 37946
DWELL .UNITS . . . . : 0 PARKING SPACES : 0 PRN1 f 16,01 NJP 12109/94 37946
I'NSPECT I ON AREA : 1 SHOREL I NE7 . . . . :N PECK I 6.51 NJP 12169194 37946 TOTAL: 161.11 VAIAIATION: 53=161
SETBACKS— __.__..____._ __— TOILETS . . . . . . . . . . : 0 FUEL TYPES---- -- -.__._ BOILERS/COMP--- -- MOBILE HOME--
FRONT . . .N 5 .Oft BATH BASINS . . . . . . : 0 :7 0--3 HP . - 0
REAR . . . .S 5 .Oft BATH TUBS . . . . . . . . : 0 3-15 HP . ! 0 MODEL :F'LEETWOOD
SIDE ( 1 ) .E: 5 .Oft SHOWERS . . . . . . . . . . : 0 FURN < 1O0K BTU : 0 15-30 HP . : 0 —MAKE---._.._.-
SIDE (2 ) .W S .Oft WATER HEATERS . . . . : 0 FURN >�1O0K BTU : 0 30-50 HP . : 0 4443A
SHRL i NF .7 0 .Oft CLOTHES WASHERS . , . 0 FURN — FLOOR . . . . 0 50•4- HP . : 0 .-YEAR--- - --
AREA --- ___._____.__.___ KITCHEN SINKS . . . . : 0 HEAT PUMP . . . . . . : 0 94
LOT SIZE — :', FLOOR DRAINS . . , . . : 0 VENT SYSTEMS . . . : 0 EVAP COOLERS : 0 LENGTH :44
BUILDING . . . : 1232sf DRINKING FOUNT . . . : 0 VENT FANS . . . . . , : 0 HOODS . . . . . . . : 0- WIDTH . :28
BASEMENT . . . : Osf LAUNDRY TRAYS . . . . . 0 DOMES . INCIN :O -SERIAL.#-------
DECKS . . . . . . .. 56sf DISHWASHERS . . . . . . : 0 AIR HANDLING UNITS— COMML . I NC I N :0 7
GAR/CARP :? Osf GARB DISPOSALS . . . . 0 <- 10000 atm . : 0 RELOC/REPAIR : 0
AT/DT . :? URINALS . . . . . . . . . . . P > 10000 cfm . : 0 OTHER UNITS . : 0
M I SC PL.M FIXTURES : 0 GAS OUTLETS . : 0
P104ECT DESCRIPTION:NOBIIF HONE AND DECKS
PROJECT LOCATION:80 DOWN NORTHSHOP.E ROAD 10 NISSIOK CREEK ROAD ITS ABOUT 112 111F AFTER YOIJ CROSS THE THIRD 611106E ON MISSION 4REEK ROAD ON LEFT SIDE OF ROAD.
THIS PERMIT BECONES NULL. AND VOID IF NONE 01 CONSTRUCTION AUTHORIZED IS NOT CONNFNCED WITHIN 1D1 DAYS, 01 if CONSTRUCTION OR WORK IS SUSPENDED FOR A PERIOD
OF 181 DAYS AT ANY TINE AFTER WORK IS COONENCED. EVIDENCE Of CONTINUATION Of WORK IS A PROGRESS INSPEC11011 1111110 THE 101 DAY PERIOD, FINAI INSPECTI011 OUST BE
APPROVED BEFORE 8111LOING CAN BE OCCUt.lE1�
OWNER OR AGENT - — .,, ( _. r_— _ DATE
BID PRN! . r►vi 11:11 ,i f 11 C46ft.084M TO ATTACHED +'Ar*3 T►0W 13 AtnU I RE0
CONCRETE MECHANICAL MOBILE HOME
Footings-Setback date by Ribbons
date by Gas Piping date
Foundation Walls date by setup
date by INSULATION date Eby
BG/SLAB Insulation Floors Final
date by date by date 3--3 /- 5 by [--
FRAMING Walls FIRE DEPT.
date by date by
PLUMBING date by OTHER
Groundwork Attic
d date by
ate b /
D.W.V. WALLBOARD NAILING
date by date by
Water Line FINAL INSPECTION
date by date by date by
I
Page No. 2 CASE HISTORY FOR CASE NO.: BLD94-1050
WESTSOUND CONCEPTS
NE1561 MISSION CREEK RD BELFAIR
03/23/95
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- ---
BLDC200 MH Setup inspection 03/10/95 03/13/95 03/13/95 NOT ALL OF THE CORRECTIONS WERE DONE FAIL LW 03/16/95 LAW
FROM THE LAST LIST, THE PERIMTER BLOCKS
ARE STILL NOT ON THE EDGE OF OPENINGS 4
FT. AND GREATER.
BLDC200 MH Setup inspection 03/15/95 03/16/95 03/16/95 DONE LW 03/16/95 LAW
BLDC210 MH Final inspection 03/21/95 03/21/95 03/21/95 CONTRACTOR WAS NOT READY FOR INSPECTION. FAIL LW 03/23/95 LAW
BLDC210 MH Final inspection 03/22/95 03/23/95 03/23/95 CORRECTION: FAIL LW 03/23/95 LAW
1. POST THE ADDRESS.
2. PROVIDE 3X3 FT. LANDING OUT SIDE
EVERY DOOR.
M
Page No. 1 CASE HISTORY FOR CASE NO.: BLD94-1050
WESTBOUND CONCEPTS
NE1561 MISSION CREEK RD BELFAIR
03/23/95
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- ---
BLDA010 Application received / / / / 07/09/94 APPLICATION NEVER TURNED INTO BRENT TO 07/14/94 KW
BE FILE SEARCHED, TO KERRY ON 7/13/94
BLDA100 Approved For Issuance / / / / 12/08/94 DONE KS 12/08/94 KS
BLDA500 (F) Issue building permit / / / / 12/09/94 DONE NJP 12/09/94 NJP
BLDB110 Structural Plan Review 12/07/94 / / 12/08/94 no site plan and no deck plans sent DONE CDW 12/08/94 CDW
letter out 8/894 CPH
TURNED IN DECK AND PLOT PLANS 12/07/94
CPH PLACED IN PROPERTY FILE AND GIVEN TO
CLARK
BLDB130 Planning Review 07/14/94 / / 07/28/94 DONE MMS 07/28/94 MMS
BLDB134 RLC Checklist Review / / / / 07/22/94 DONE AHB 07/26/94 TMJ
BLDB135 Addressing / / / / 07/19/94 DONE GMM 07/19/94 GMM
BLDB200 Environmental Health Review 08/08/94 / / 08/11/94 Septic Design in file DONE HLS 11/16/94 HLS
back to bldg. when done please
BLDB210 Water Adequacy 11/16/94 / / 11/16/94 Cedar View Tracts system WFI #06151A is DONE HLS 11/17/94 CPH
adequate DOH overnite review
BLDC199 Mobile Strip Footing 12/13/94 12/14/94 12/14/94 CONDITIONAL APPROVAL: COND LW 12/14/94 LAW
1. THE PROPERTY LINES ARE NOT MARKED,
MAINTAIN A 5 FT. SET BACK BETWEEN THE
OVER HANG ON THE UNIT AND THE PROPERTY
LINES.
2. FINISH HANGING AND TYING REBAR,
MAINTAIN 3 INCHES OF CLEARANCE BETWEEN
THE GROUND AND REBAR.
WHEN ALL OF THE REQUIREMENTS ARE MET ITS
OK TO POUR.
BLDC200 MH Setup inspection 02/28/95 03/01/95 03/01/95 CORRECTIONS; FAIL LW 03/13/95 LAW
1. THE SET UP MANUAL NEEDS TO BE PROVIDE
FOR THE INSPECTION.
2. THE SKIRTING WAS INSTALLED BEFORE THE
SET INSPECTION WAS DONE, REMOVE 1 PIECE
OF SKIRTING AT EACH CORNER.
BLDC200 MH Setup inspection 03/01/95 03/02/95 03/02/95 CORRECTIONS; FAIL LW 03/13/95 LAW
1. PERIMETER BLOCKS ARE REQUIRED AT ALL
FOUR CORNERS AND AT THE EDGES OF
OPENINGS 48 INCHES AND GREATER.
2. WHEN USING CABLE FOR TIE DOWNS, THE
CABLE MUST BE 1/4 INCH STAINLESS STEEL
CABLE OR 1/2 GALV. STEEL CABLE, A TURN
BUCKEL NEEDS TO BE USED WITH IT (1/2)
WITH A CLOSED EYE.
3. THE SET UP MANUAL REQUIRES TIE DOWNS
TO BE 12 FT. O.C.
i
Page No. 1 CASE HISTORY FOR CASE NO.: BLD94-1050
WESTSOUND CONCEPTS
NE1561 MISSION CREEK RD BELFAIR
03/01/95
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- ---
BLDA010 Application received / / / / 07/09/94 APPLICATION NEVER TURNED INTO BRENT TO 07/14/94 KW
BE FILE SEARCHED, TO KERRY ON 7/13/94
BLDA100 Approved For Issuance / / / / 12/08/94 DONE KS 12/08/94 KS
BLDA500 (F) Issue building permit / / / / 12/09/94 DONE NJP 12/09/94 NJP
BLDB110 Structural Plan Review 12/07/94 / / 12/08/94 no site plan and no deck plans sent DONE CDW 12/08/94 CDW
Letter out 8/894 CPH
TURNED IN DECK AND PLOT PLANS 12/07/94
CPH PLACED IN PROPERTY FILE AND GIVEN TO
CLARK
BLDB130 Planning Review 07/14/94 / / 07/28/94 DONE MMS O7/28/94 MMS
BLDB134 RLC Checklist Review / / / / 07/22/94 DONE AHB 07/26/94 TMJ
BLDB135 Addressing / / / / 07/19/94 DONE GMM 07/19/94 GMM
BLDB200 Environmental Health Review 08/08/94 / / 08/11/94 Septic Design in file DONE HLS 11/16/94 HLS
back to bldg. when done please
BLDB210 Water Adequacy 11/16/94 / / 11/16/94 Cedar View Tracts system WFI #06151A is DONE HLS 11/17/94 CPH
adequate DOH overnite review
BLDC199 Mobile Strip Footing 12/13/94 12/14/94 12/14/94 CONDITIONAL APPROVAL: COND LW 12/14/94 LAW
1. THE PROPERTY LINES ARE NOT MARKED,
MAINTAIN A 5 FT. SET BACK BETWEEN THE
OVER HANG ON THE UNIT AND THE PROPERTY
LINES.
2. FINISH HANGING AND TYING REBAR,
MAINTAIN 3 INCHES OF CLEARANCE BETWEEN
THE GROUND AND REBAR.
WHEN ALL OF THE REQUIREMENTS ARE MET ITS
OK TO POUR.
BLDC200 MH Setup inspection 02/28/95 03/01/95 03/01/95 CORRECTIONS; FAIL LW 03/01/95 LAW
1. THE SET UP MANUAL NEEDS TO BE PROVIDE
FOR THE INSPECTION.
2. THE SKIRTING WAS INSTALLED BEFORE THE
SET INSPECTION WAS DONE, REMOVE 1 PIECE
OF SKIRTING AT EACH CORNER.
MASON COUNTY .
BUILDING III 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location /S� / Af s:-<i� /.
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found:
Items listed below must be corrected to gain code compliance
C e i -r- zF,6ej7r5
Al
_1 Z —� d• L . fug , �
You are herebynotified that the above corrections shall be made BEFORE
o
PROCEEDING WITH ANY FURTHER WORK
all for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
❑ OK to
Department ,C3/
Date 3- Z - Inspector L -J
■ oo s NnT Mo *V THI T
" ,��-
MASON COUNTY
Mason County Bldg. III 426 W. Cedar
P.O. Box 186 Shelton, Washington 98584
PE RI /A I T' CC:) ND I T l C) NF3
Case No . : BLD94- 1050
For : WF.STSOUND CONCEPTS
Page : 1
1 ) The use , handling and storage of hazardous materials or flammable and combustible
liquids in excess of 10 gallons Is not allowed without the- approval of the Mason County
Fire Marshal .
X Y/).4�L
2 ) Proposed structure or arty portion thereof greater than 30" in height from grade line,
must maintain a minimum of 5 ' setback from all property lines , easements and right of
ways .,
' X sZA
_—.____
3 ) All approved plans are required to be on-site for inspection purposes . if inspection is
called for and plans are not on site Ap roval WILL NOT be granted . In addition , a
Re- Inspection fee in the amount of t'ifd .fd per hour (minimum 1 hour ) will be charged and
must be collected by this department prior to any further inspections being performed or
approval granted .
X llL„za� _.
4 ) PURSUANT TO 1991 UNIFORM BUILDING CODE , SECTION 305(C ) AND SECTION 513 ALL SITES MUST
HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO St PLAINLY VISIBLE
AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY . MASON COUNTY BUILDING
DEPARTMENT PEOUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS . A
REINSPECTION FEE BASED ON RATES IN TABLE 3A OF THE 1991 UNIFORM BUILDING CODE WILL BE
l ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING
• INSPECTIONS .
X
5 ) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND USC
REQU S
X
6 ) REQUIRED INSPECTIONS ( Footing Inspection-prior to pour , Set-up Inspection-prior to
skirting, Final Inspection-prior to occupancy) . I have received a copy of the General
Information and Guidelines-Mobile/Manufactured Housing Installations Handout for detailed
descriptions of all required inspections on my mobile/manufactured home installation . I
hereby assume all responsibility for the scheduling of these required inspections . If
these required inspections are not requested, inspected and siggned off ( approved) by the
Inspector in the prescribed order , I understand that reinspectlon fees and an hourly
--——— ---——— ——————— ———— -
MASON COUNTY
Mason County Bldg. III 426 W. Cedar
P.O. Box 186 Shelton, Washington 98584
investigation fee pursuant to the 1991 UBC . Table 3A will be assessed in addition to my
original permit 'fees to resolve any questionable practices or problemv= that have been
discovered . I further understand that this investigation will be scheduled as time
allows . Until resolution of any/ all problems no occupancy ( F ' nal Inspection ) will be
granted for the residence .
OWNER/CONTRACTOR ( indicate which ) Signature
7) All mobile/manufactured home landings or deck::• must eestand i ng ( self supporting) .
The largest landing or deck permitted without drawl or a building permit is 36" x 36" .
Any landing or dee that is 30" or more in height oat walking surface to finish grade
requires a guardrail . Any landing or, deck that h s I or more risers requires a handrail ,
Any landing or deck larger, than 36" x 36" must be permitted which requires structural
drawings and a building permit application . This Installation Permit does NOT include
any Ian ng or deck larger than the 36" .x 36" :size .
X
8 ► Changes to approved building plans that affect compliance to the 1991 Washington State
Energy Code, 1991 Ventilation and Indoor Air Quality
Code , the Uniform Building Code andlor Mason Counx°ky, #1 , �ttions musk
approved pproved by Mason County prior to construction
9 ) CONSTRUCTION PROCESS 'TO BE FIELD CORRE OUi VD N COUNTY BUILDING
DEPARTMENT AND UNIFORM BUILDING CODE . x
i _
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
Mason County Bldg. III 426 W.Cedar
P.O. Box 186 Shelton,Washington 98584
(206)427-9670
BUILDING PARKS& RECREATION FAIR/CONVENTION CENTER ADMINISTRATION
August 8, 1994
Westsound Concepts Inc.
P.O. Box 227
Port Orchard, WA 98366
To whom it may concern:
It has come to my attention that Case #BLD94-1050/Westsound Concepts is proposing to build
2-decks (4X6 and 4X8). Mason County requires that any landing larger than 3X3 a permit and
(2) two sets of prints submitted for review before we can approve this permit.
I have enclosed an example of a deck handout for your convenience.
If you have any further questions you can reach me Mon-Fri 8:00-5:00 (206) 427-9670 Ext, 352
Sincerely,
�h
Christine Herth
Building/Clerical
cc: property file
enc: deck handout
s l FT ;
24" 24".
Rim Joist
12 X V dote:
— Decking
This drawing
aaL to scale
BEAM l
PLACEMENT I Warning:
SCHEDULE I
;' Beck surfaces
Joist
`) FT in excess of 38"
above grade
require railings
(Der code)
ost
eam I
12"
Rim Joist
F 1' FT 1'
POST PLACEMENT SCHEDULE
SPEC'2FICA7r:10NS
LL 60#/SF.•
LEDGER . . 2 x 6 APCL !STOCK .,' 'POSTS 4 x 4 APCL STOCK
BEAMS . . . 4 x 6 APCL STOCK ;;�J,OISTS 2 x 6 APCL STOCK @ 24" U. C.
DECKING 2 x 6.�"OUTDOOR,"'.W00041.
ALL PURPOSE TMCONSTRUCTION LBR (APC,L) : COMPLIES W/CABO R-308
W/UBC SEC; 25 16 (c)
Pr \
CO.•cwflc �b � PT
I Gko�... 0 6G Grs<
�Yt'Yt SKxcl�*� tQ�t Gadc.,.q SKstc�t.s
�NCcu ►h o b�l E Li
— _ I
� I
QsJ,ir i /}�c,S.z/s
2XA 41CK T (e• o/C
g� � � F•Lc=��'1.
! I I 1 1
ma,l
�l yq P
�— •�►fa.nG � RfatCd Oa.T
ce—C'Kne Psct
B l£Am DGCC Ty prcO l &J'X U' R12uS.n6A.
^1 fi.+ -n C bs 1l /{ar►.c RC y. cep c ice"'
2><8z/6 4�oaf 36,K
YxYYrL y i
pill
Co..c 91 K
t
are r rG t� I 5iv
oo� 3 z=sy 3 rsc .�
o
- Y rn=tl_VS1Guff.�+
Ts� ooaAL.%j UcZaz
Qrb6c^., Sloc�-2uq �eT4S�
I ��< 7� (A n c, �e�
pOS/�. 7�)
VIC-I N 1TY MAP
PLAT 0 MtSS int,3 c-2FE k-
!✓ CaR SEC. 25
_ T 23 N, Z W, wM 25
--,_ RESERVk� FOR
11 pvrWr`' USE i EN2L OERCIMI%�j NE COR. 6 F - SE4
L, p�AT'
LOT I - CUL 9 � SEG. 2.5
18� OG V" 33O.Z Ca
�` 2 2D0 . 2_G 130 .00 ` �/ /v
7 %�o
LLJ
w _ M � O
v � a N u In
.Q N u �
m
cr
1 -
I � W W -
s Be la' o�' w �� o.Z� ' J70I4N S 6N
SELLER . 0 ((t� (-R
20 O .ZG' E-- I3�.�0 a L11 i
_ ro Il- le �. ��, 1-- - I�.00 -, a .STIIR ZOUTE 2
� 30
N - W LLf I3 0 �c. ► 7
oo T,�` !v�y_=sF�m o — Tip 6 :�� _ ;7 U E L M(R
cn
f N 4, 07 U�
,1 a rl '��'3 r +�_ Aa . 44572 b
\ — — FOUND MONuM�NT
I JCL
,� Q �, ,_ I a•7 0 Z
18 0 2 -
m
0 SHOM- PLAT - TDHN S"oNNSON
l G/��'sa� CIO
cn . .. UPVSN lOAT� FOR: J
IRVYIN ENGINEEMMG vim , A R . �v, �o Joy�tJ So tl
2"it Englnet",Tin,n and land Surveying t`�
P
8 So. ?nth"�� Tacoma, VJA 98409 r Cl-1lp_ CK1:-: SCA I_ 0 .
n f n-rn moo-.. .,� � ._L ,,E C �� O F .. � Jai _ � ,- •. � I
Permit No.
MASON COUNTY
BUILDING PERMIT APPLICATION
426 W. Cedar/P.O. Box 186, Shelton, WA 98584 427-9670/1-800-562-5628�y�
PLEASE PRINT �'S�
#1 Owner C°i Phone �j��� �l o
g,ftWAddress Fire District#
City St &2A _Zip�S12Q
Directions to Job Site 642% , `1/6 fz % W To &!Z�9aa/
Owner Mailing Addresses Q n 2 Z
City D St Zip
Lien/Title Holder 00,4)
,4)
Address /
City e/- z2zk St zip R
#2 Contractor Name I e-<lad)0/)0 L' o/t,C- Contractor Reg#1 �`sTC tnPoc G
Addre 2—Expiration Date / 7 /9S'
City r—t O 2 St (AJA Zip ne#
#3 If septic is located on proje site, include records.
Connect to Septic? V Public Water Supply Well a"
Connect to Sewer System? Name of Systemlp
Y Y
(if residential, proof of potable water is required)
#4`►Nrcel No.-V 3 Z.
egal Description
#5 Building Square Footage: (existing/proposed) �1
1 st FI2=/ 2nd FI / 3rd FI / Loft /
Basement / Decker& / #bedrooms / #bathrooms /
Garage / Carport / (Circle: Attached or Detached?)
Other sq.ft.
#6 Use of building '2- i ,a e "L, c g- CLOW Describe work
#7 Type of Job: New Add Alt Repair Other
#8 MOBILE/MANUFACTURED HOME IF 8M`T �4s
Model Year Make'- Mol Jde5
Length� �h Z28 ' Serial No.
# Bedrooms # Bathrooms Type of Heat
Purchase Price$ .�3,,SRO
#9 Indicate by circling the applicable source if any water is on or adjacent to subject property:
River Pond Creek Stream Wetland Lake Marsh Saltwater Seasonal Runoff Other
I
Show following on the site plan
Lot Dimensions Flood Zones
Existing Structures Fences
Structure Setbacks Driveways
Water Lines Shorelines
Drainage Plan Topography
Septic Systems Wells t
Proposed Improvements Easements Name of Flanking Street Indicate Directional by (N, S, E, W)
Name of Fronting Street in relation to plot plan
APPLICANT TO DRAW SITE PLAN BELOW
40
APPLICANT TO DRAW TOPOGRAPHY PROFILE BELOW
l
Plumbing Fixtures ($3 each) Fee Mechanical Fixtures ($6 each
No.�2-_Toilets CIRCLE FUEL TYPE: Gas lectric
�—Bath Basin Heatpump, Other
Bath Tub§ No. Units Fees
,tAShowers Furn BTU
V Hot Water Htr _ Heatpumps
Laundry Washer Vent Systems
/ Sinks _ Spot Vent Fans
/Floor Drains No.. Boilers/Compressors
Laundry Basins HP
k'b-ishwasher No.. Air Handling Units
Disposal _ cfm#
,,tWUrinals Fire Protection Systems
Other Auto. Fire Alarm Sys 50.00
ed Fire Supp. Sys 50.00
Permit Basic Fee 15.00 Auto i e Sprink Sys 25.00
TOTAL PLUMBING $ No. Other
Gas Outlets
r
Wood, Gas, Pelle Stove
NOTICE: THIS PERMIT BECOMES NULL AND VOID IF
' ORK OR CONSTRUCTION AUTHORIZED IS NOT COM-
MENCED WITHIN 180 DAYS OR IF CONSTRUCTION OR Permit Basic Fee 15.00
WORK IS SUSPENDED OR ABANDONED FOR A PERIOD TOTAL MECHANICAL $
OF 180 DAYS AT ANY TIME AFTER WORK IS COM-
MENCED. PROOF OF CONTINUATION OF WORK IS BY
MEANS OF A PROGRESS INSPECTION.
OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIRE- I CERTIFY THAT I AM A CURRENTLY REGISTERED
MENTS OF THE CONTRACTORS REGISTRATION LAW CONTRACTOR IN THE STATE OF WASHINGTON AND I
RCW 18.27, AND AM AWARE OF THE MASON COUNTY AM AWARE OF THE ORDINANCE REQUIREMENTS REGU-
ORDINANCE REQUIREMENTS FOR WHICH THIS PER- LATING THE WORK FOR WHICH THE PERMIT IS ISSUED
MIT IS ISSUED AND THAT ALL WORK DONE WILL BE IN AND ALL WORK DONE WILL BE IN CONFORMANCE
CONFORMANCE THEREWITH. NO CHANGES SHALL BE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT
MADE WITHOUT FIRST OBTAINING APPROVAL FROM FIRST OBTAINING APPROVAL FROM THE BUILDING
THE BUILDING DEPARTMENT. DEPARTMENT.
X OWNER X BY
DATE DATE
FOR OFFICIAL USE ONLY:Accepted by: Date:
DEPARTMENTAL REVIEW
FOR OFFICE USE ONLY
Approved Cond. Hold
Approval
Planning: M161GI;n��,vx ►v� rvlUwl S�?�-I�cc11� myy
Environmental Health:
Building Plan Review
e0
Occupancy Group: /K Type of Const:
Fire Marshal:
1
1
Other:
f
Special Conditions: FEES
Building Permit
( COS
Plan Check `r
Plumbing Fee
Mechanical Fee
Wood/Gas/Pellet Stove
Radon Monitor
Violation Fee
Site Inspection
Building State Fee 1�
Other
Other
Building Valuation: TOTAL FEE