Loading...
HomeMy WebLinkAboutBLD2025-00122 SFR - BLD Application - 1/30/2025 Docusign Envelope ID:458E66OA-933B-4593-AA7C-3E4454E894FD Permit No: 2)L—C)2025—0012 2_ MASON COUNTY COMMUNITY DEVELOPMENT RECEIVED ter' 1 Permit Assistance Center,Building,Planning `>C BUILDING PERMIT APPLICATION BAN 30 2025 PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: t NAME:Gregory+Tiffani Allen NAME:Adair Homes,Inc. 11515`yw,/" �-Akler MAILING ADDRESS:233 E Williams PI MAILING ADDRESS:10876 Myhre PI NW#109 CITY:AIIyn STATE:WA ZIP:98524 CITY:Silverdale STATE:WA ZIP:98383 PHONE#1:(253)229-9855 PHONE:(360)488-4004 CELL: PHONE#2:(253)229-7153 EMAIL:aabbey@adairhomes.com EMAIL:tauen745@comcast.net L&I REG#ADAIRH•262RZ Exp. 01/09/26 PRIMARY CONTACT: OWNER❑ CONTRACTOR[a OTHER❑ NAME aliam Abbey EMAIL aabbey@adairhomm.eom MAILING ADDRESS 10876 Myhre PI NW#109 CITY Silverdale STATE WA ZIP 98383 PHONE (960"84004 CELL PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 122292400010 ZONING RR5 LEGAL DESCRIPTION(Abbreviated) TR 1 OF SE NW.S 49/60 FIRE DISTRICT SITE ADDRESS 233 E Williams PI CITY Allyn,WA 98524 DIRECTIONS TO SITE ADDRESS From Silverdale south on WA HWY3,left on Williams Pl,property is at the end on the left IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO I] SNOW LOAD:35 psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Cheekall ilwt apply): SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW 0 ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage.Commercial Bldg.Etc.)SFR IS USE: PRIMARY❑v SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2.5 HEATED STRUCTURE? YES(Whole Bldg)❑Q YES(Part[,)of Bldg)❑ NO❑ DESCRIBE WORK proposed 3 bed,2.5 bath 2164 sqft SFR w/attached 5W sgft 2 car garage SQUARE FOOTAGE:(proposed) I ST FLOOR 2164 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK 198 sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE 550 sq.ft. Attached❑+ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC El SEWER❑ / NEW v❑ EXISTING(a PLUMBING IN STRUCTURE? YES❑� NO❑ lfyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES Q NO[] EXISTING SQ.FT. 0 EXISTING BEDROOMS 0 PROPOSED BEDROOMS 3 TOTAL BEDROOMS 3 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON 1—�SWigned by: COUNTY CODE 14.08.42) AaA,t Q 1/29/2025 0 " $49WNER(Must be sinned by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH :7ocusign Envelope ID:458E660A-933B-4593-AA7C-3E4454E894FD Permit No: Ic3�D2g2� - Od122 MASON COUNTY COMMUNITY DEVELOPMENT Permit Assistance Center, Building,Planning PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Gregory+Tiffani Allen NAME:Adair Homes,Inc. MAILING ADDRESS:233 E Williams PI MAILING ADDRESS:10876 Myhre PI NW#109 CITY:Allyn STATE:wA ZIP:96624 CITY:Silverdale STATE:WA ZIP:98383 1"PHONE:(253)229-9855 PHONE:(360)488-4004 CELL: 2nd PHONE:(253)229-7153 EMAIL :aabbey@adairhomes.com EMAIL:tallen745@comcast.net L&I REG#ADAIRH•262Rz EXP. o1 /og /26 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):122292400010 Zoning:RR5 LEGAL DESCRIPTION(Abbreviated):TR 1 of SE NW,s 49/60 SITE ADDRESS:233 E Williams PI CITY:AIbn DIRECTIONS TO SITE ADDRESS: From Silverdale south on WA HWY3, left on Williams PI, property is at the end on the left TYPE OF JOB: NEW 0 ADD=ALT=REPAIR=OTHER=USE OF BUILDING New SFR LOCATION OF FIXTURES/UNITS—IST FLOOR ✓Q 2ND FLOOR=BASEMENT 0 GARAGED✓ OTHERO PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric0✓ LPGE�vatural GasODuctless0 Toilets 3 Type of Unit No. of Units Fees Bathroom Sink 4 Furnace 1 Bath Tubs 2 Heat Pump 1 Showers 1 Spot Vent Fan 5 Water Heater 1 Propane Tank 1 Clothes Washer 1 Gas Outlets 1 Kitchen Sinks 1 Wood/Gas/Pellet Stove Dishwasher 1 Kitchen Exhaust Hood 1 Hose bibs 3 Dryer Vent 1 Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Signed by: X i 1/29/2025 oE,Sigmtwc of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 1BN EH Setbacks -'2-A A.) Drainfield/Reserve requires 10'setback from footing/foundations B.)Septic tank(s)requires 5'setback from all footing/foundations C.)No foundation/Perimeter Drains within 30ft,downgradient of Drainfield/Reserve area EH APPROVED D. No Cut Banks N a 9 ( )(greater than 5ft and over 45 degrees)within � �' r a 50ft,down gradient of Drainfield/Reserve area Rhonda Thompson 03/24/2025 , g b 2 � � CoCvU � . Z Disclaimer: Mason County does not require a survey to obtain a building permit. As a result, site A plans may not reflect accurate data. It is the applicants responsibility to comply with setback requirements. & b rz GO '75 zo'sat Gaut � � IT 10,min rl; 4 ProIr f" LY 7'4 YF• E G o � . Non-Fish stream burffer is 115'on either side of stream i N The destruction or alteration of Fish and Wildlife Habitat Conservation Area's or their buffers through removal,excavation, i grading,dumping,discharging or filling of any material;clearing; 03/07/2025 shading;intentional burning;vegetation removal(terrestrial, freshwater,or marine);planting of non-native vegetation that APPROVED would alter the character of the FWHCA or buffer;or the MASON COUNTY DCD PLANNING construction or placement of structures or increasing the RR5 Zoning 50-0 RUEMAW structural footprint shall undergo mitigation sequencing and shall Front Yard Setback.25'. require a habitat management plan. Side&Rear Yard Setbacks. Residential dwelling digitally ao and accessory structures is 20'. S "Ru.*signed OR 10%width of lot if not more than 1 00'wide by Scott OR approved ADV Ruedy Name Gregory + Tiffani Allen Parcel# 122292400010 BLD# 7 02S - 00122 Mason County Department of Community Development S��EIVED Small Parcel Stormwater Management Application/Worksge 1 of 2) JAN 3 Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet ofsima ' 'Redevelopment means,on an already developed site,the creation or addition of impervious surfacces�,Istructural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. cu/ate Impervious Surfaces PI se Complete This Tab► .. Surface Type Length X Width = Area All dimensions in feet Buildings X = Proposed SFR 71.5 X 58.0 = 2991 Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved.. gravel or packed area per definition above table X = Patios/Walks X = X = Any paved.. gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 2991 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date:_ If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknoii ledge and sign the information provided on page 2 of 2. Page I of 2 \ame Gregory + Tiffani Allen r'arcel it 122292400010 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: htti)//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system (see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) AA An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and Stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail:P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St,Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT.352 Mail:P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. x .Aa--�O�r, Owner/Agent/Contractor(circle one)Date:1/30/2025 Page 2 of 2 MASON COUNTY COMMUNITY SERVICES Building Planning,Environmental Health,community Health These requirements apply to all IRC building types, including detached one-and two-family dwellings and multiple single-family dwellings (townhouses). Contact Information Project Information Owners Name: Site Address: GRE 0P,N t TIFf_AN1 P.LLI✓N 2.33 E . WILLIAMS PL - Mailing Address: Parcel Number: 233 E• W ILt-I Ft WA P1. 1222I1 - 24 - 000 10 Square Feet(total): Project Description: 2-1 iv-4 NEW Sf. iz• Ventilations Compliance: Whole House Ventilation system � Whole House Ventilation using exhaust fans Integrated with a Forced Air System Other,describe: Instructions:This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings:Table R402.1- Insulation and Fenestration Requirements by Component,Table R406.2- Fuel Normalization Credits and 406.3- Energy Credits. .Marine 4(Table R402.1.3) Fenestration U-Factor bj 0.30 Skylight U-Factor b 0.50 Ceiling R-Value° 60 Wood Frame Wall R-Value 91 20+5 or 13+10 Floor R-Value 30 Below Grade Wall c,h 10/15/21 int+TB Slab d,f R-Value& Depth 10,4ft R-values are minimums.U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design ' thickness of the insulation,the compressed R-value of the insulation from Appendix A Table A101.4 of chapter 51-11C WAC shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on the interior of the wall,or R- C 21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."5TB"means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. For single rafter or joist vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter slab insulation when applied f to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall meet the requirements for thermal barriers protecting foam plastics For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for E climate zone 5 of ICC 400. Prescriptive Path—Single Family 2021 Washington State Energy Code-R Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard framing 16 inches on h center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. i The first value is cavity insulation,the second value is continuous insulation.Therefore,as an example,"1113+10"means R-13 cavity insulation plus R-10 continuous insulation. 1 A maximum U-factor of 0.32 shall apply to vertical fenestration products installed in buildings located above 4000 feet in elevation above sea level,or in windborne debris regions where protection of openings is required under Section R301.2.1.2 of the International Residential Code. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (Energy Equalization credits) and Table 406.3 (energy credits)to achieve the following minimum number of credits.To claim this credit,the building permit drawings shall specify the option selected and the maximum tested building air leakage and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit:5 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit:8 credits All dwelling units that are not included in#1 or#3 3. Large Dwelling Unit: 9 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 2 credits All other additions shall meet 1-3 above. Summary of Table R406.2 System Credits Energy Equalization Credits I Select-ONE System Type Type _ Single Family 1 For combustion heating equipment meeting minimum federal efficiency standards for the 0.0 ❑ equipment listed in Table C403.3.2(5)or C403.3.2(6) 2 For an initial heating system using a heat pump ;that meets federal standards for the equipment listed in Table C403.3.2(2)and supplemental 1.5 ❑ heating provided by electric resistance or a i combustion furnace meeting minimum standards listed in Table C403.3.2 5( )b j 3 For heating system based on electric resistance only (either forced air or Zonal) 0.5 _ __ ___ ❑ i 4` For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2)or C403.3.2(9)or Air to water heat pump. 3.0 �J units that are configured to provide both heating and; cooling and are rated in accordance with AHRI 550/590 5 For heating system based on electric resistance with 1. Inverter-driven ductless mini-split heat pump 2 0 system installed in the largest zone in the dwelling,or' I 2.With 2kW or less total installed heating capacity j per dwelling The gas back-up furnace will operate as fan-only when the heat pump is operating.The heat pump shall operate at all temperatures above 38°F 3.3"C)(or lower).Below that"changeover"temperature,the heat pump would not operate to provide space heating.The gas fa mace provides heating below 38"F (3.3`C)(or lower). c.Additional points for the HVAC system are included in Table R406.3. j Prescriptive Path—Single Family 2021 Washington State Energy Code-R . . Energy Energy Credit Option Descriptions Please indicate Options Details chosen credit 1.0 1.3 Efficient Building Envelope 1.5 1.4 Efficient Building Envelope 2.5 2.1 'Air Leakage Control and Efficient Ventilation 1.0 2.2 Air Leakage Control and Efficient Ventilation 1.5 2.3 :Air Leakage Control and Efficient Ventilation 2.0 3.21 High Efficiency HVAC 0.5 1.5 tVAC 4.1 High Efficiency HVAC Distribution System 0.5 Efficient Water Heating 0.5 5.2 Efficient Water Heating 0.5 5.3 Efficient Water Heating 0.5 5.4 Efficient Water Heating 1.0 5.5 Efficient Water Heating 1.5 5.6 Efficient Water Heating 2.0 5.7 Efficient Water Heating 2.5 5.8 Efficient Water Heating 2.5 6.1 Renewable Electric Energy(3 credits max) 1.0 7.1 Appliance Package 0.5 Total Credits a. An alternative heating source sized at a maximum of 0.5 Watts/ft2(equivalent)of heated floor area or 500 Watts, whichever u bigger,may be installed m the dwelling unit. u. See Section x401.1 and residential building in Section xzuz for Group R-a scope. c opuvns.z1 can only be taken with Options y.z and 3.s.Toqualify to claim Option s.1z with s.a'the system shall beaz'aspeed heat pump system.Variable capacity heat pumps are ineligible from claiming this option. d. This option may only be claimed if serving System Type 4 or 5 from Table n406.2. e. Primary living areas include living,dining,kitchen,family rooms,and similar areas. [ Option 3.10 may one be taken with EfficientWater Heating Option 5.1 or 5.2.Equipment sizing for space heating shall be calculated as provided in Section R403.7 with increased capacity to provide a minimum of 75 percent of peak hot water demand or shall be sized in accordance with approved manufacturer's specifications or guidance. Supplementary heat for water heating shall be in accordance with section x4O3.sJ preocripu,ePoth-emole Family aoz1 Washington State Energy ovueR WSU Code Compliance Calculator,WSEC 2018 Project Information SISI-241012-ALLEN Review required for custom entries:-Doors-Vertical Glazing-Flat/Vaulted Ceilings UA Reduction=71,81,Proposed UA is better than baseline by 23 Contact Information UA reduction meets percent target of selected Option 1 Window area is 13%of floor area Results assume your inputs are complete and correct A�,aI,,,5 sh,,,,I be reviewed by your AHJ. ANALYSIS SET UP g What code compliance pathway are you using? Table R406.3 UA Trade Off Project Building Type? New Construction Occupancy Type? R3 Single family homes and duplexes Code Version? WSEC 2021 WSEC-R Rev:Oct.2023,https://www.sbcc.wa.gov/sites/default/files/2023-12/0 Classification: Medium Dwelling Unit--2461 sq.ft. Baseline Description: Code Baseline-Baseline and proposed window areas are equal. I About Your Selection: No exempt window or door areas RESULTS-Comparison of Baseline and Proposed Design Component Performance,R occupancies Baseline Proposed Design U Area UA U Area UA Doors U= 0.300 38 11.3 0,192 38 7.2 Overhead Glazing U= 0.500 0 0.0 0 0.11 Vertical Glazing U= 0.300 316 94.8 0.190 316 60.0 Flat/Vaulted Ceilings U= 0.024 2,164 51.9 0.018 2,164 38.5 Wall(above grade) U= 0.056 1,550 86.8 0.049 1,550 76.0 Floors over Crawlspace U= 0.029 2,164 62.8 0.025 2,164 54.1 Slab on Grade F= 0.540 0 0.0 0 0.0 Below Grade Wafl U= N/A 0 0 0.0 Below Grade Slab F= N/A 01 01 0.0 `Values from Table R402.1.2(Oct 2023) Baseline UA Total 307.6 Proposed UA Total[471.8 Required Credits 8.0 Proposed Creditsfrom Tables 406.2 and 406 UA Percent Reduction UA Reduction If the Proposed UA<_the Target UA..and the Proposed Credits from Table 406 are>_those required in Section R406,then the home meets the WSEC. Table R406.2 Energy Equalization Credits Fuel Normalization Energy Credits Total Credits System No. _ Full Description Select System Type Credits(406.2) (406.3) (406.2&406.3) For heating system using a heat pump that meets federal standards for the 4 equipment listed in Table C403.3.2(2)or Table C403.3.2(9)OR Air to Water heat Variable Refrigerant Heat Pump or Air-to- pump units that are configured to provide both heating and cooling and are rated in Water Heat Pump accordance with AHRI 550/590 Table R406.3 Energy Credits Option No. Category Select Options Energy Credits Brief Description of Selected Cl tions' Perscriptive compliance based on Table 402.1.3/U-0.18 1 Efficient Building Envelope Option 1.3 1.5 vertical fenestration/R-21+12ci walls/R-60 adv ceiling/R-38 floors or R-10 perimeter&fully insulated slab.Or 22.5 reduction in UA per section R402.1.5 2 Air Leakage Control and Efficient Ventilation Air source ducted Heat Pump w/Min HSPF2 of 10(HSPF of 3.1-3.10 High Efficiency HVAC Option 3.6 1.0 11). If htg design temp is 23F or below,a cold climate variable capacity heat pump is required. 3.11 High Efficiency HVAC:Smart Thermostat 0.0 1:12018 WSECX2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325-kmksm Ylbm 3/26/2024 WSU Code Compliance Calculator,WSEC 2018 4 High Efficiency HVAC Distribution System 0.0 5.1 Efficient Water Heating:Drain Heat Recovery 0.0 Compact Hot Water Distribution System Max volume between 5.2 Efficient Water Heating:Compact Hot Water Distribution Option 6.2 0.5 heat source and fixture is 16 Oz per section R403.5.2,on demand circ.Pump may be required. 5.3-5.8 Efficient Water Heating Option 5.6 2.0 Electric heat pump water heater meeting NEEA Tier 3. 6 Renewable Electric Energy kWh 0.0 7 Appliance Package 0.0 Energy Credits 5.0 'Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements I:\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325—ROM(124bm 3/26/2024 WSU Code Compliance Calculator,WSEC 2018 THERMAL ENVELOPE DETAILS-Proposed Design Conditioned Floor Area,Proposed Desi n 2,461 sq.ft Classification Medium Dwelling Unit Notes Exterior Doors Plan Component Door Width Hei ht ID Description Ref. U Qt. Feet 1nC° Feet '"`" Area UA S236 ENTRY-TRADITIONS Custom 0.22 1 3 6 " 20 4.4 Refer to WSEC R402. S210-GARAGE MAN DOOR Custom 0.16 1 2 " 6 a 18 2.8 Refer to WSEC R402. 0 0.0 0 0.0 01 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Sum of Area and UA 38 7.2 Exterior Doors Area Weighted U 1 0.192 Overhead Glazing Plan Component Glazing Width Hei ht ID Description Ref. U at. Feet '"`" Feet "`n Area UA i Sum of Area and UA 0.0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 12 Plan Component Glazing Width Height ID Description Ref. U Cit. Feet �-h Feet "`" Area UA 1 SLIDER Custom 0.19 2 5 5 50.0 9.50 Refer to WSEC R402.1 2 SLIDER Custom 0.19 3 6 5 90.0 17.10 Refer to WSEC R402.1 3 FIXED Custom 0.19 2 3 5 30.0 5.70 Refer to WSEC R402.1 4 PATIO DOOR Custom 0.19 1 6 6 '0 41.0 7.79 Refer to WSEC R402.1 5 SLIDER Custom 0.19 1 4 3 12.0 2.28 Refer to WSEC R402.1 6 FIXED Custom 0.19 1 1 5 5.0 0.95 Refer to WSEC R402.1 7 SLIDER Custom 0.19 2 5 5 50.0 9.50 Refer to WSEC R402.1 8 SLIDER Custom 0.19 2 4 4 32.0 6.08 Refer to WSEC R402.1 9 SINGLE HUNG Custom 0.19 1 21 3 6.0 1.14 Refer to WSEC R402.1 10 11 12 Sum of Area and UA 1 316.01 60.0 Vertical Glazing Area Weighted U 0.190 Vertical Glazing and Doors Area Weighted U 0.190 Flat/Vaulted Ceilings Plan Component Attic ID Description Ref. U Area UA R-60 BLOWN,FLAT CEILING,TRUSSES @ 24"O.C. Custom 0.017 1.600 27.2 ROb"to Wst.0 R402 R49 blown Attic ADV baffled 2018 1.5,1.7,2021 Code E 10-7 0.020 S64 11.3 Sum of Area and UA 1 2,1641 38.5 Walls Above Grade Plan Component Wall ID Description Ref. U Net Area UA R23 cavil +RO foam INT 2X6W La A A 0,049 1 b50 76 f\2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021_20240325-NSS292%m 3 26?U7:1 r . WSU Code Compliance Calculator,WSEC 2018 Sum of Area and UAI 1,5501 76 IA2018 WSEC\2018 Compliance forms\2021\Code Compliance Calculator\WSU_C32021 20240325-U2Sf2b2P rn 3/26/2024 WSU Code Compliance Calculator,WSEC 2018 Floor over crawl or exterior -_ Mr Plan Component _ Floor .„ UA ID Description Ref. U Area R38 vented Joist(2021 1.2,1,3;2018 1.3-1.5) 10-3 0.025 2.164 54 Sum of Area and UA 2,164 54 Slab on Grade less than 2 feet belowgrade) Plan Component Slab Slab ID Description Ref. F Perim FP Sum of Perimeter and FP 0 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab Slab Slab ID Description Depth Ref. U Area UA F Perim UA Sum of Area,Length and UA Of 0.0 0 0 Links to Download Forms,Checklists and Other Resources Link Compliance Certificate Compliance Certificate Instructions Insulation Certificate for Residential New Construction Insulation Certificate Duct Testing Affadavits Existing Construction Affidavit,Existing New Construction Affidavit,New Prescriptive Checklist for 2018 WSEC Prescriptive Checklist Alterations(Remodel)Worksheet Worksheet Show Ventilation Calculator? Hide Show Distribution System Calculator?Hide Show Heating System Sizing?Hide I:\2018 WSEC\2018 Compliance fonns\2021\Code Compliance Calculator\WSU_C32021_20240325—N85t 02%m 3/26/2024