FIR2025-00003 Hoodsport ACE - FIR Inspections - 3/13/2025
Mason County Fire Marshal ' 615 W. Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 N Fire Alarm Certification/Final Test FIR ZozS- Ubbb? Location: /sd L4GG Contractor: Phone #: Contact: Ju ; Test Date: CHECKLIST V Verify panel is in "Normal"condition and clear of any signals Kill Power At Electrical Panel ✓ AC Trouble/ No Power,panel & verify dedicated circuit, red breaker& lockout Activate device(s), verify it activates the alarm and shows correctly on the panel ✓ Check the Notification Alarm Circuit(NAC) for activation of devices. Walk building while alarm is activated under battery load. Check for all lights and sounds to be in-sync ✓ Silence Alarm Activate a few other devices in different areas to verify alarm reactivates after being silenced ✓ Reset Alarm .% Does panel still show trouble (due to AC power)? Disconnect Signal Loop Circuit (SLC) to create/verify a trouble for each device on circuit Reconnect SLC. System should reset & only AC trouble showing f Disconnect the communication line &verify communication trouble ✓ Do batteries AMP/HR match plans? Z it FACP Sign on Door(s) leading to panel location? �rpd 3/13 Notification Device Device Test Log Time Comments Smoke detector at FACP Waterflow Inspector's Test yij Tamper Switch ✓✓// Manual pull Manual pull at Manual pull at Heat Detector 'y /✓ , 3l Heat Detector Heat Detector Heat Detector Heat Detector Smoke Detector Smoke Detector Art Smoke Detector �Mdr, :; r!orti /O✓2 Punch List/Comments: ��r✓��F/fG/��is�d� s.,� �� ff4��p���l G1 � a Passed Final Test? Yes No Honeywell IntelliKnight 6808 Battery Calculation ®KZF NtCHT Secondary Power Source Requirements Standby Device Type Qty Current Draw Total City I Current Draw F Total 1.Control Panel 6808 Control Panel 1 x 1 0.190000 1=1 0.190000 1 1 jxj 0.250000 1=1 0.250000 2.Addressable SLC Devices SK-PHOTO(-T) x 0,000300 = x 0.000300 = SK-PHOTO-W(-T) 18 x 0.000200 = 0.003600 18 x 0.000450 = 0.008100 SK-HEAT(-HT)(-ROR) 15 x 0.000300 = 0.004500 15 x 0.000300 = 0.004500 SK-HEAT-W(HT)(ROR) x 0.000200 = x 0.000450 = SK-BEAM x 0.002000 = x 0.002000 = SK-BEAM-T x 0.002000 = x 0.002000 = SK-DUCT x 0.000300 = x 0.000300 = SK-ACCLIMATE x 0.000300 = x 0.000300 = SK-CONTROL x 0.000375 = x 0.000375 = SK-MONITOR 4 x 0.000375 = 0.001500 4 x 0.000375 = 0,001500 SK-MINIMON x 0.000375 = x 0.000375 = SK-PULL-SA x 0.000375 - x 0.000375 = SK-PULL-DA 16 xj 0.000375 = 0.006000 16 jxj 0.000375 = 0.006000 SK-MONITOR-2 x 0.000750 jxj 0.000750 = SK-MON-10 x 0.003500 = x 0.003500 = SK-RELAY-6 x 0.001450 = x 0.001450 = SK-CONTROL-6 x 0.002250 = x 0.002250 = SK-RELAY 4 x 0.000255 = 0.001020 4 x 0.000255 = 0.001020 SK-RELAYMON-2 x 0.001300 = x 0.024000 1=1 SK-ZONE jxj 0.000270 = x 0.000270 = SK-ZONE-6 x 0.002000 = x 0.002000 = SK-FIRE-CO x 0.000300 = x 0.007200 = 3.SLC Accessory Bases B200S x 0.000300 = x 0.000300 = B20OS-LF x 0.000300 = x 0.000300 = B200SR x 0.000300 = x 0.000300 = B200SR-LF x 0.000300 = x 0.000300 = B224RB x 0.000500 = x 0.000500 = RTS 151 x 0.000000 = x 0.007500 = RTS151KEY 1XI 0.000000 1= I jxj0.007500 1=1 RA100Z 1XI 0.000000 1 =I I 1XI0.010000 1=1 4.SLC Isolator Devices SK-ISO jxj 0.000450 [=I I 1XI0.000450 = ISO-6 I x 1 0.002700 1 1 jxj0.102000 1=1 B224B1 I x 1 0.000500 1 1XI0.000500 1=1 5.Auxiliary Power Draw-SLC Devices SK-CONTROL(Aux. Power) x 0.001700 = x 0.007000 = SK-CONTROL-6(Aux. Power) x 0.008000 = x 0.020000 = SK-ZONE(Aux. Power) x 0.012000 = x 0.090000 = SK-ZONE-6(Aux. Power) x 0.050000 = x 0.270000 = B200S(Aux. Power) x 0.000500 = x 0.035000 = B200S-LF(Aux. Power) x 0.000550 = x 0.140000 = B200SR(Aux. Power) I x 1 0.000500 = x 0.035000 = B200SR-LF(Aux. Power) x 0.001000 = xj 0.125000 1=1 Honeywell Internal Page 1 1/15/2025 6.Accessory Modules 5860 1 x 0.020000 = 0.020000 1 x 0.025000 - 0.025000 5824 x 0.045000 - x 0.045000 - 5496 x 0.010000 = x 0.010000 = 5895XL x 0.010000 = x 0.010000 = 6855 x 0.020000 = x 0.025000 = 6860 x 0.025000 - x 0.050000 = 5865-4 x 0.035000 - x 0.145000 = 5865-3 x 0.035000 = x 0.145000 = 5880 x 0.035000 = x 0.200000 = 5883 x 0,000000 = x 0.220000 = SK-IP-2 x 0.093000 = x 0.136000 = SKIP-21_)D x 0.098000 = x 0.155000 = CELL-MOD x 0.055000 = x 0.100000 = CELL-CAB-SK x 0.055000 = x 0.100000 = WSK-WGI Aux. Power x 0.040000 = x 0.040000 = SLC Power x 0.024000 = x 0.024000 - SK-NIC x 0.021000 = x 0.021000 = SK-NIC-KIT x 0.021000 = x 0.021000 = SK-FSL x 0.079000 = x 0.079000 - SK-FML x 0.053000 = x 0.053000 = SK-FFT x 0.120000 = x 0.230000 = Miscellaneous Device 3 x 0.000000 = x 0,000000 Miscellaneous Device 4 x 0,000000 = x 0.000000 - Miscellaneous Device 5 x 0.000000 = x 0.000000 = 8.Notification Appliance Circuits NAC 1 0.000000 = 0.803000 = 0.803000 NAC 2 0.000000 = 0.378000 = 0.378000 NAC 3 0.000000 = 0,390000 = 0.390000 NAC 4 0.000000 = 0.000000 = Total Standby Load 0.226620 Total Alarm Load 1.867120 Honeywell Internal Page 2 1/15/2025 Honeywell IntelliKnight 6808 Battery Calculation 0 SILEM Note 1:You are fully responsible for verifying these calculations. KNT('.HT Note 2: Use the dropdowns in the yellow cells to enter values. Calculation in Total Sheet StandbyRequired 24 Hours Standby Load Current 0.22662 Amps x 24 = 5.439 AH Required Alarm Time in Minutes 5 Minutes Alarm Load Current Amps 1.86712 Amps x 0.084 1= 0.157 AH Total Current Load 5.596 AH Multiply by the Deratin Factor 1.2 1= x 1.20 Total Ampere Hours Required 6.71 AH Recommended Batteries: BAT-1270-7AH Batteries Battery Check The batteries can be charged by the 6808 Charger. The batteries can be housed in the 6808 Cabinet. Current Draw Check Circuit#1 current is within the limitations of the circuit. Circuit#2 current is within the limitations of the circuit. Circuit#3 current is within the limitations of the circuit. Circuit#4 current is within the limitations of the circuit. 6808 Control Panel: The output current is within thepanel's limitations. m Jonathan Olson ®� NICET #40743 Fire Alarm Systems Level III CERTNO 103664 EXP 08,01,2025 Honeywell Internal Page 3 1/15/2025 Honeywell OKM IntelliKnight 6808 Circuit Detail NAC 1 Device System Sensor 15CD 1 x 0.000000 = 0.000000 1 x 0.041000 = 0.041000 System Sensor 75CD HS 3 x 0.000000 = 0.000000 3 x 0.143000 = 0.429000 System Sensor 75CD STIR 3 x 0.000000 = 0.000000 3 x 0,111000 = 0.333000 x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0,000000 = x 0.000000 = x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.803000 NAC 2 Device • QtY Alarm Draw Total System Sensor 15CD HS 1 x 0.000000 = 0.000000 1 x 0.071000 = 0.071000 System Sensor 15CD STR 4 x 0.000000 = 0.000000 4 x 0.041000 = 0.164000 System Sensor 75CD HS 1 x 0.000000 = 0.000000 1 x 0.143000 = 0.143000 x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = X. 0,000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.378000 NAC 3 Device Qty Non-Alarm Draw Total Oty I Alarm Draw Total System Sensor 15CD HS 1 x 0.000000 = 0.000000 1 x 0,054000 = 0.054000 System Sensor 15CD STIR 2 x 0.000000 = 0.000000 2 x 0.041000 = 0.082000 System Sensor 75CD HS 1 x 0.000000 = 0.000000 1 x 0.143000 = 0.143000 System Sensor 75CD STIR 1 x 0.000000 = 0.000000 1 x 0.111000 = 0.111000 x 0.000000 = x 0.000000 = x 1 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = X1 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.390000 NAC 4 D• • x 0.000000 = x 0.100000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = XI 0.000000 = 1XI 0.000000 =1 x 0,000000 = x 0.000000 = x 0,000000 = x 0.000000 = x 0.000000 = X1 000000 = x 0.000000 = Total Standby Load 1 0.000000 Total Alarm Load 0.000000 Honeywell Internal Page 4 1/15/2025 Honeywell OKM IntelliKnight 6808 EOL Voltage Drop Starting Voltage 20.4 Volts Minimum Voltage @ EOL 16 Volts Voltage Drop Warning% 10.00% Current Actual Draw Wire Type Resistance Len th Resistance Voltage @ EOL Percent Drop Feet (One Circuit Name Amps AWG Ohms/1000 ft way) Ohms Volts Percent NAC 1 0.803 1#14 Solid 1 3.07 1 225 1 1.38 19.29 5.44% NAC 2 0.378 #14 Solid 3.07 125 0.77 20.11 1.42% NAC 3 0.390 #14 Solid 3.07 150 1 0.92 20.04 1.76% NAC 4 0.000 #14 Solid 3.07 1 0.00 1 20.40 0.00% Resistance Table Wire Type Resitance AWG Ohms/1000 ft. #10 Solid 1.21 #10 Stranded 1.24 #12 Solid 1.93 #12 Stranded 1.98 #14 Solid 3.07 #14 Stranded 3.14 #16 Solid 4.89 #16 Stranded 4.99 #18 Solid 7.77 #18 Stranded 7.95 Note:All Resistance values are taken from Table 8 Conductor Properties of the NFPA 70 National Electrical Code.All values are for Direct Current Resistance at 75°C (167°F). Honeywell Internal Page 5 1/15/2025 Honeywell SILer T KNIGHT SK-HEAT, SK-HEAT-HT, and SK-HEAT-ROR Addressable Thermal Heat and Rate-Of Rise Detectors The SK-HEAT,SK-HEAT-HT,and SK-HEAT-ROR are plug in thermal detectors,with integral communication,that provide features that surpass conventional detectors.These thermal detectors are for use with the Honeywell Silent Knight series fire alarm control panels(FACPs). ' SK-HEAT,SK-HEAT-HT and SK-HEAT-ROR are intelligent sensors that utilize a state-of-the art thermistor sensing circuit for fast response. • 0 Sensitivity is continuously monitored and reported to the FACP.Point ID capability allows each detector's address to be set with rotary address switches,providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-HEAT is a fixed temperature sensor that uses a thermistor sensing circuit to produce 135°F(57°C)fixed temperature alarm.SK-HEAT-HT is a SK-HEAT(BASE INCLUDED) variable high temperature detector that provides high temperature detection at 1350F-190°F(57°C-881C).SK-HEAT-ROR is a rate-of-rise temperature sensor with 135"F(57°C)fixed temperature alarm. COMPATIBILITY SK-HEAT,SK-HEAT-HT,and SK-HEAT-ROR are compatible with the following detector bases: B21OLP:6"base(included) B501:2 wire base 8224RB:Relay base B224BI:Isolator base B200SR:Sounder base FEATURES & BENEFITS • •Reliable analog • Variety of mounting • Plug-in mounting • Tamper-proof feature communications for options to meet any provides ease of available on mounting trouble-free operation application installation bases • Age resistant polymer • Dual LED indicators • Optional remote LED • Rotary address housing for 360'visibility annunciator(System switches for fast • Innovative thermistor • Detector transmits Sensor'PN RA100Z) installation sensing circuit signal to indicate • UL Listed • Superior EMI maintenance is resistance for required reliability SK-HEAT, SK-HEAT-HT and SK-HEAT-ROR Technical Specifications . PHYSICAL ORDERING INFORMATION For a complete listing of all Height:2.0"(S.Ocm) SK-HEAT:Fixed thermal detector(135°F) compliance approvals and Diameter:6.1"(155mm)installed in B201LP base SK-H EAT-ROR:Fixed rate of rise detector(135°F) certifications,please visit www.silentknight.com. Shipping Weight:4.8oz(137g) SK-HEAT-HT:Fixed high temperature thermal detector(190°F) Microsoft.Windows,and ELECTRICAL the Windows Logo are Operating Voltage:15-32VDC Peak ACCESSORIES registered trademarks r de arks or Standby Current:300 µA @ 24VDC RA100Z:Remote LED annunciator Microsoft Corporation. LED Current:6.5mA L 24VDC max RMK400:Recesses mounting kit.Provides low profile for use with B501 Silent Sensor,"nightm.System and Honeywellw ENVIRONMENTAL XR2B:Detector removal tool.A removal and are registered Operating Temperature replacementtoolforSK series plug-in detectors. trademarks of Honeywell SK-HEAT&SK-H EAT-ROR:-41—100°F(-20°C— Includes the T55-127-000 International,Inc. 38°C) M02-04-01:Detector test magnet. This document is not SK-H EAT-HT:-4°—150°F(-20°C—66°C) M02-09-00:Test magnet with telescoping handle intended to be used for Humidity:10%—93%non-condensing XP-4:Extension Pole for XR2131.Extends from 5— installation purposes.We 15 ft. try to keep our product THERMAL RATINGS T55-127-000:Detector Removal Head information up-to date and accurate.We SK-H EAT:Fixed temperature alarm BCK-200E:Black Detector Kit.For SKseries cannot cover all specific 1350F(57°C) detectors applications or anticipate SK-HEAT-HT:High temperature heat sensor 1351 all requirements.All F subject -190°F(57°C-88°C) specifications are sub COMPATIBILITY 1 The SK-HEAT,SK-HEAT-HT and SK-H EAT-ROR to change without notice. SK-HEAT-ROR:Rate-of-rise detection 150 F/min (8.3°C/min) are compatible with the following Honeywell For Technical Support, Silent Knight fire alarm control panels: call800-446-6444. 6820:Addressable fire alarm control panel 6820EVS:Addressable fire alarm control panel with an emergency voice system. 6808:Addressable fire alarm control panel 6700:Addressable fire alarm control panel 5700:Addressable fire alarm control panel 5808:Addressable fire alarm control panel 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 SILENT' Doc 3501201 Rev G I Ol/18 800-328-0103 ©2018 Honeywell International Inc. KMC.HT Km V H UTU W *_ak - Addressable Photoelectric Smoke Detectors The Silent Knight' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and `... maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics,and are direct replacements for the SK-PHOTO Series detectors.A new modern,sleek contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel Point ID capability allows each detectors address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level.Dual electronic thermistors add 135°F(57 0 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detectorfor use with DNR Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Integral communications and built-in • Expanded color options • Sleek and stylish contemporary design device-type identification • SEMS screws for wiring of the separate base • Stable communication technique with • Remote test feature from the panel • Optional remote,single-gang LED noise immunity • Built-in functional test switch activated by accessory • Addressable by device external magnet • Optional sounder,relay,and isolator bases • Rotary,decimal addressing(Refer to the • Walk test with address d351634isplay(an Silent Knight panel manuals for device address of 121 will blink the detector LED capacity) 12-(pause)-I) • Two-wire SLC connection • Low standby current • LEDs blink every time the unit is polled • Built-in tamper-resistant feature • 3600-field viewing angle of the visual alarm • Designed for direct-surface or electrical- indicators(two bi-color LEDs);LEDs blink box mounting green in Normal condition and turn on • Sealed against back pressure Honeywell steady red in Alarm • Plugs into separate base for ease of installation and maintenance SILENT' 13 KNIGHT INSTALLATION B224BI-IV:Ivory,plug-in System Sensor isolator detector base The SK-PHOTO-W Series plug-in intelligent thermal detectors use a ACCESSORIES separate base to simplify installation,service,and maintenance. Installation instructions are shipped with each detector. TR300:White,replacement flange for B210LP or B300-6 bases Mount base(all base types)on an electrical backbox which is at TR300-IV:Ivory,replacement flange for B21OLP or B300-6 bases least 1.5"(3.81 cm)deep.For a chart of compatible junction boxes, RA100Z(A):Remote 3-32 VDC LED annunciator,mounts to a U.S. see SK-61045. single-gang electrical box,for use with B501 and B300-6 bases Note:Because of the inherent supervision provided by the SLC loop, only end-of-line resistors are not required.Wiring"T-taps"or branches M02-04-00:Test magnet are permitted for Class"B"wiring. M02-09-00:Test magnet with telescoping handle Note:When using relay or sounder bases,consult the SK-ISO CK300:White,detector color kit,pack of 10 installation sheet 156-3627 for device limitations between isolator CK300-IV:Ivory,detector color kit,pack of 10 modules and isolator bases. CK300-BL:Black,detector color kit,pack of 10 OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent)on the Signaling Line Circuit(SLC).It responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the panel(or a local magnet test),it stimulates its electronics and reports an alarm.It blinks its LEDs when polled and turns the LEDs on when commanded by the panel.The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note:"-IV"suffix indicates ivory color. SK-PHOTO-W:White,low-profile photoelectric sensor SK-PHOTO-T-W:White,same as SK-PHOTO-W but includes a built-in 1350F(57°C)fixed-temperature thermal device SK-PHOTO-R-W:White,low-profile intelligent photoelectric sensor, remote test capable,for use with DNR/DNRW B300-6:White,standard flanged low-profile mounting base B300-6-BP:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged low-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL:Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base B501-WHITE-BP:Bulk pack of B501-WHITE,contains 10 B20OS-WH:White,Intelligent,programmable sounder base B20OS-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B20OS-LF-WH:White,Low Frequency Intelligent,programmable sounderbase B20OS-LF-IV:Ivory,Low Frequency Intelligent,programmable sounderbase B200SR-LF-WH:White,Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for retrofit applications B224RB-WH:White,plug-in System Sensor°relay base B224RB-IV:Ivory,plug-in System Sensor relay base B224BI-WH:White,plug-in System Sensor isolator detector base Page 2 of 3—351634:C•5/28/2020 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAUENVIRONMENTAL DETECTOR SPACING AND APPLICATIONS ' ` ' Sensitivity: _ registered trademarks of -UL Applications:0.5%to 4.0%per foot Silent Knight recommends spacing obscuration. detectors in compliance with NFPA 72.In Honeywell International, low airflow applications with smooth ceiling, intendedThis -ULC Applications:0.5%to 3.5%per foot space detectors 30 feet(9.1m).For specific " • ' ' obscuration information regarding detector spacing, used for installationpurposes. Size:2.0"(51mm)high;base determines placement,and special applications referto try to keep our product inf• • diameter NFPA 72.ASystem Smoke Detector up-to-date• . accurate. cannot Application Guide,document SPAG911coverall specific applications or -B300-6:6.1"(15.6 cm)diameter available at www.systemsensoncom. -B501:4"(10.2 cm)diameteranticipate requirements. •- - • - •- For a complete list of detector bases,see AGENCY LISTINGS AND APPROVALS S K-61045. without notice. Shipping weight:3.4 oz.(95 g) These listings and approvals apply to the Country of origin: Mexico modules specified in this document.In some Operating temperature range: cases,certain modules or applications may • SK-PHOTO-W:32°F to 122°F(0°C to 50°C) not be listed by certain approval agencies,or • SK-PHOTO-T-W:32°F to 100°F(0°C to listing may be in process.Consult factory for 380C) latest listing status. • SK-PHOTO-R-W installed in a DNR/DNRW: • UL Listed:S6173 -4°F to 158°F(-20°C to 70'C) • FM Approved • CSFM:7272-0559:0512 UL/ULC Listed Velocity Range:0-4000 ft/ min.(1219.2 m/min.),suitable for installation in ducts Relative humidity:10%—93%non- condensing Thermal ratings:fixed-temperature set point 135°F(571C),rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communication every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203.484.7161 351634 1 c 1 05/20 Sn1wr* www.sitentknight.com ©2020Honeywell International Inc. ®WC.HT SYSTEM �A SEIVSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications - System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modem aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units. The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING O o LISTED S5512 FM approved except 7125-1653.0504 S401 1 for ALERT models 7135-1653.0503 3057383 AVDS868-02.12101/2017•Page 3 L-Series Specifications Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95. 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS8W-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn • .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86"2.12/01/2017•Page 3 SYSTEM �..� SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SPECTRQUed SpectrAlert®Advance outdoor audible visible products �► a v A N c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40oF to 151 of • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back U� boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch F M MEA 7300-,653:,67(«,moor strobes) LISTED APPROVED approved 7125-1653:188(hornese�orobe, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket S4011(chimes,horn strobes,horns) 53593(outdoor and Merl strobes) MEA452-05•E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Arch itecttEngineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6""L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-1-x 5.1""W x 2.0-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UIL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UIL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with •8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe • Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 Randy Collins From: Randy Collins Sent: Tuesday, March 11, 2025 12:28 PM To: 'Justin Leech' Cc: Drew Carlson Subject: Ace Hoodsport Fire Alarm Follow-up Permit 2025-00003 Justin, When I returned to the office, I applied Table 17.6.3.5.1 to the retail space with the 16'-6"ceiling and came up with following: • The plans show the space is 52' tong by 20'wide • With a 16'-6"ceiling,the detector spacing is multiplied by.71. • Given normal spacing of 30'x 30',that would reduce the required spacing to 21'-3" • Given the width is 20 feet,spacing for that dimension is adequate • Given the length of the room is 52 feet and there are 3 detectors present, spacing for that dimension is also adequate. To that end,the only remaining items on the punch list: • Providing"As-Builts"that reflect the current floor plan for the office area at the east end of the retail space as well as the reduced detectors in the attic spaces • Installing a permanent"FACP Inside"sign on the door to the electrical room where the panel is. Once you send me the plans and a picture of the FACP sign, I will sign off on the permit. Questions, let me know. Randy Collins Fire Marshal Mason County 360 427-9670 x309 360 490-0167 Cell 1