HomeMy WebLinkAboutGRD2018-00003 9 acre biosolids pond embakment - GRD Permit / Conditions - 6/1/2018 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County P! 615 W Alder St y Shelton, WA 98584 xs� LAND MODIFICATION BUILDING PERMIT GRD2018-00003 OWNER: BIO RECYCLING CORPORATION RECEIVED: 3/13/2018 CONTRACTOR: LICENSE: EXP: ISSUED: 6/1/2018 1 ENGINEER: LICENSE: EXP: EXPIRES: SITE ADDRESS: 820 E WEBB HILL RD UNION PARCEL NUMBER: 321181002000 LEGAL DESCRIPTION: S1/2 NE PROJECT DESCRIPTION: DIRECTIONS TO SITE: SCOPE OF WORK: EXCAVATION AND EMBANKMENT TO CONSTRUCT BROCKDALE RD TO MCREAVY RD, L ON WEBB HILL RD, FOLLOW TO A DOUBLE-LINED SURFACE IMPOUNDMENT FOR WINTER STORAGE SITE ADDRESS OF CLASS B LIQUID BIOSOLIDS (FILTRATE) - TOTAL SIZE OF PARCEL 80 ACRES - SIZE OF AREA TO BE EFFECTED 9 ACRES - ESTIMATED Inspection Area: Fill?: Yes Comp. Plan Desig.: Rural Grading?: Yes IRO Desig.: Cutting?: Yes Shoreline Desig.: Not Applicable Area Graded: 9.00 Acres SEPA?: Yes Cubic Yards: 86,789.00 FEES Type By Date Amount Receipt Grading Plan Check Fee GMM 3/13/2018 $356.78 S32018000, Grading Permit Fee GMM 3/13/2018 $1,323.44 S32 0 1 80 001 Planning Review Fee GMM 3/13/2018 $240.00 S32018000! Planning Stormwater Re\, TW 5/29/2018 $300.00 S320180001 Total $2,220.22 GRD2018-00003 Please refer to the following page(s)for conditions of this permit. Page 1 of 7 CONDITIONS FOR GRD2018-00003 1) Subject to all permit conditions as required by ECY. X rX�K 2) Access Roads to the site must not be degraded as a result of work. X (!Z5 / 3) A 20 foot wide fire apparatus access road is required to extend within 150 feet of any portion of the exterior walls of the building. An unobstructed vertical clearance of 13 feet, 6 inches is required. Dead-end fire apparatus, s roads longer than 150 feet are required to have an approved turnaround. The maximum grade of a fire apparatus access road is 14%. X 4) Approved per site plan and topographic cross-section provided by Parametrix dated May 2018. X 5) ALL CLEARING,CUTTING, GRADING, EXCAVATING, TERRACING, FILLING AND SIMILIAR WORK WILL BE REGULATED BY THE REQUIREMENTS PURSUANT TO THE MASON COUNTY GRADING PERMIT STANDARDS ADOPTED BY RESOLUTION 141-96 and MASON COUNv�E, TITLE 14, CHAPTER 14.44. X 6) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCW THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAYx 7) The owner/applicant shall provide to Mason County inspection reports prepared by the engineer record, complying with the requirements as noted in Chapter 14.44, section 14.44.220 through 14.44.230 and documents prepared by Parametrix and detailed in Appendix D of Final Engineering report for Surface Impun ment dated May 2018. X �e 8) Cut and fill slopes shall be setback from site boundaries in accordance with Section 14.44.190. X AV 9) Owner responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X GRD2018-00003 Please refer to the following page(s)for conditions of this permit. Page 2 of 7 10) Compliance with an approved Storm Water Plan shall be subject to an on site inspection, or inspections, by the engineer of record (Parametrix) or an authorized representative. Said inspection(s) shall be performed in accordance with the approved plan, and prior to any modification that would make a determination of compliance impossible. Inspection reports shall be submitted to verify all engineering requirements have been completed in accordance with the approved storm water plan. Reports shall be submitted to the Mason County Department of Community Development prior to each corresponding inspection and final permit approval. �f all special inspection reports shall be made available at time of inspection. X 11) An inspection performed by a representative of the geologist, their authorized representative, or engineer of record, shall be completed on-site prior to the footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations. In addition a final inspection report, prepared by a representative of the geologist, their authorized representative, or engineer of record shall be required to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations. Reports shall be submitted to the Mason County Building Dept., PO Box 186, Shelton, WA 98584, prior to the footing and final inspections and available for inspection rr X 12) Retaining walls needed to support a surchargZW/ chs structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 13) Prior to any earthwork a Stormwater Pollution Prevention Plan (SWPPP) shall be submitted to Community Services by the selected Contractor and approved TESC measures shall be in place per the approved plans. X The Contractor shall be responsible for ensuring construction activity will not result in discharge to surface waters of the State. X The Engineer of Record (or Engineer's designee) shall perform construction inspection of the conveyance system to ensure construction as designed and/or document any deviations. The Engineer of Record shall submit a certified as-built prior to final approval. X 1 The Owner shall conduct Operations and Maintenance according to Appendix C, Sections 6.5, 9.1.2 and 9.2.1 of the Design Report. The Annual Report shall be subrrj#ted to Community Services upon request. X GRD2018-00003 Please refer to the following page(s)for conditions of this permit. Page 3 of 7 14) Scope of work includes excavation and embankment to construct a double-lined surface impoundment for winter storage of class B liquid bio solids (filtrate)with fencing and dam safety as appoved by Department of Ecology. X 15) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. Documents to be present on site for all inspections: '"Final Design Engineering Report for Surface Impoundment: 847 pages "Plan pages: 25 Pages X 16) All changes to"approved" plans that effect compliance any Mason County ordinance or regulation, must be reviewed and approved by engineer of record and submitted to Mason County prior to construction. X J�OK 17) All permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. All engineer and geological reports must be sumbitted prior to final inspections. X 4�" 18) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 19) All property lin 11 be clearly identified at the time of inspection. X 20) A COMPACTION REPORT PREPARED AND SIGNED LICENSED DESIGN PROFESSIONAL SHALL BE REQUIRED. THE REPORT SHALL VERIFY THAT FILL MATERIAL HAS BEEN COMPACTED TO NOT LESS THAN NINETY-PERCENT OF MAXIMUM DRY DENSITY. SUBMIT COMPACTION REPORT(S) TO THE MASON COUNTY BUILDING DEPT., 615 W ALDER STREET, SHELTON, WA 98584 PRIOR TO THE FINAL INSPECTION. X �� GRD2018-00003 Please refer to the following page(s)for conditions of this permit. Page 4 of 7 21) Must supply a copy of the Final Design Engineering Report for Surface Impoundment dated May 2018 prepared by Parametrix on-site. X 22) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries. Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0 he person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 23) THE FOUNDATION/SLABS SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X ,dK 24) 3000 PSI CONCRETE WILL REQUIRE SPECIAL INSPECTION IF THE QUANTITY EXCEEDS 50 CUBIC YARDS< LESSER AMOUNTS WILL REQUIRE AN APPROVED CONCRETE SUPPLIER TO PROVIDE YOU WITH A�H TICKET THAT WILL BE REQUIRED TO BE SUBMITTED TO THE SITE INSPECTOR FOR THE VERIFICATION OF MATERIAL USED. X 25) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties & responsibilities shall be as specified in Chapter 17. Special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton WA 98584 and available for inspection. Inspection reportss shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final occupancy inspections`' / X 26) Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed, approval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by,the,Mason County Building Department prior to any further inspections being performed or approvals granted. X 27) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS. X 28) An inspection performed by a representative of the geologist, their authorized representative, or engineer of record, shall be completed on-site prior to the footing pour to verify that earthwork and foundation installation activities comply with the Geotechnical report or assessment recommendations. In addition a final inspection report, prepared by a representative of the geologist, their authorized representative, or engineer of record shall be required to verify that erosion control, drainage and final work is completed in accordance to the Geotechnical report or assessment recommendations. Reports S Ubmitted to the Mason County Building Dept., 615 W Alder Street, Shelton, WA 98584, prior final inspection. X GRD2018-00003 Please refer to the following page(s)for conditions of this permit. Page 5 of 7 This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 daypenody Final inspection must be approved before building can be occupied. OWNER OR AGENT: Ge%S�'/ DATE: GRD2018-00003 Please refer to the following page(s)for conditions of this permit. Page 6 of 7 o CONCRETE MECHANICAL MANUFACTURED HOMEDate Oo N _�_ O wFootings !Setbacks Gas Piping By Ribbons ....___. _ _�_ 0o Interwar Date By Interior.Date By Date By n 0 o Exterior Date By Exterior-Date B Set-up n Point Load/Isolated Footings INSULATION Date By r Date By Data By BG I SLAB INSULATION FIRE DEPARTDEPARTMENTO Foundation Walls Floors Date By n a-Date By Data By O DECKS X FRAMING Wails Date By 0 Date By Data By PROPANE TANKS O0� PLUMBING vault Date By —DI Date BY OTHER O Groundwork Attic Z Data By Date By Type- DRYWALL By D.W.V DRYWALL Type. (D Int Brace Wall 'n w Date By m Date By Date By --— 0 FINAL INSPECTION N Water Line Fire Seperation p Date By Date By Date By 00 o 1 Pass or Request Inspect. o o Type of Insp. Fail Date Date Done By Comments o o w cn v m 0 n O a 0 N O U N 3 N (D V O v r'151°EG'F1D w cp eD Mason County Community Services Building Division SPECIAL INSPECTION & 615 WAIderStreet Shelton, WA 98584 TESTING AGREEMENT 360.427.9670 ext. 352 www.co.mason.wa.us (All references are per the 2015 International Building Code) Project Name: Bio Recycling Corporation North Ranch Surface Impoundment Project Address: 820 E Webb Hill Rd, Union, Washington Building Permit Number: GRD2018-00003 Date Issued: BEFORE A PERMIT CAN BE ISSUED: The registered design professional in responsible charge shall fill out the Agreement and include the name of each inspector as well as their appropriate license/certification number. Two (2) copies of this form are to be submitted to the County prior to the issuance of a building permit. If changes are made as to who will perform the special inspections a new form shall be submitted and turned into the Building Permits & Inspections Division for approval. STATEMENT OF SPECIAL INSPECTIONS: In addition to this Agreement, a "Statement of Special Inspections" shall be provided per IBC 1704.3. This Statement shall be made as part of the approved plans, and be placed in a conspicuous location,such as the first page of the construction plans or the first page of the structural sheets. SPECIAL INSPECTORS: All special inspectors shall be approved by the Building Division prior to performing any duties. The special inspector shall provide proof of certification as a special inspector for each inspection item and be licensed by the State of Washington. SPECIAL INPSECTION REPORTS:.Special inspection reports are to meet the requirements of IBC 1704.2.4. Copies of each report are to be sent to the address listed in the letterhead noting the Project Address and Permit Number. A final report shall be submitted stating that all special inspection and structural testing items were completed and are in conformance with the approved design drawings and specifications. Items not in conformance,unresolved items, or any discrepancies in inspection coverage (i.e. missing inspections, periodic inspections when continuous was required, etc.) shall be specifically itemized in the final report. GENERAL SPECIAL INSPECTION ITEMS(per IBC Chapter 17) [Only checked items ore required] Areas requiring special inspection: Name of Agency: Name of Inspector: License/Cert.No. ❑ Unapproved Fabricators(IBC 1704.2.5) Other than Structural Steel(IBC Table 1705.2.2) ❑ Steel floor&roof decks ❑ Welding of reinforcement ❑ Cold-formed steel Structural Steel ❑ Welding(Per N5.4 of AISC 360-10) ❑ Details(Per N5.7 of AISC 360-10) ❑ High-strength bolts(Per N5.6 of AISC 360-10) Concrete Construction(per IBC Table 1705.3) ® Reinforcement,embeds,anchors Materials Testing and Randy Grey S1015D4 ® Formwork Consulting Inc. ® Materials ❑ Shotcrete ❑ Post-tensioned/Pre-stressed Concrete ® Erection of precast concrete Page 1 of 3 Mason Count ,1 y Community Services Building Division SPECIAL INSPECTION & 615 WAIder Street Shelton, WA 98584 TESTING AGREEMENT 360.427.9670 ext. 352 www.co.mason.wa.us GENERAL SPECIAL INSPECTION ITEMS(per IBC Chapter 17)-continued [Only checked items are required] Areas requiring special inspection: Name of Agency: Name of Inspector: License/Cert.No. Masonry Construction (IBC 1705.4) ❑ Prior to Construction(Article 1.15,TMS-602) ❑ As Construction Begins(Article 1.19.2,TMS-402) ❑ Prior to Grouting(Table 1.19.2,TMS-402) ❑ During Construction(Per TMS-402&TMS-602) Wood Construction ❑ High-Load Diaphragms(IBC 1705.5.1) ❑ Wood Trusses>60ft(IBC 1705.5.2) Materials Testing and Randy Grey S101504 ® Soils(IBC Table 1705.6) Consulting Inc. ❑ Driven Deep Foundations(IBC Table 1705.7) ❑ Cast-in-place Deep Foundations(IBC Table 1705.8) ❑ Helical Pile Foundations(IBC 1705.9) ❑ Sprayed Fire-Resistant Materials(IBC 1705.13) ❑ Mastic&Intumescent Coatings(IBC 1705.14) ❑ EIFS(IBC 1705.15) ❑ Fire-Resistant Penetrations(IBC 1705.16) ❑ Smoke Control(IBC 1705.17) ❑ Other (IBC 1705.1.1) ❑ Other (IBC 1705.1.1) SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE(IBC Section 1705.11) [Only checked items are required] Areas requiring special inspection: Name of Agency: Name of Inspector: License/Cert.No. ❑ Structural Steel(IBC 1705.11.1&AISC 341-10) ❑ Structural Wood(IBC 1705. o - orme Steel TIBC . ® Mechanical&Electrical Components(1705.11.4) Materials Consultin ninq Inting and Randy Grey SI01504 c. ❑ Architectural Comp . ❑ Storage Racks(IBC 1705.11.7) Page 2 of 3 j Mason County Community Services Building Division SPECIAL INSPECTION & 615 W Alder Street Shelton, WA 98584 TESTING AGREEMENT 360.427.9670 ext. 352 www.co.mason.wa.us Declaration by Architect/Engineer g I, the design professional in responsible charge for this project, declare that the 1. SIM P wAs above listed special inspection and structural testing items are required for this of �j project in accordance with IBC Chapter 17. � �co c x Digitally signed by Cedar I. 5/30/18 l Signature Date: 2018.05.3012:17:43-07'00' Date o 55398 ISTER�'9 �S�'IONAL � /30/18 Declaration by Owner I, the Owner of the project, de a that the above listed firm(s) or individual(s) are hired by me to perform special inspections and str testjpdfor the project pursuant to IBC 1704.2. Signature Date CONTRACTOR RESPONSIBILITY: Each contractor involved with the construction of wind or seismic force-resisting systems shall comply with the requirements of IBC 1704.4. The contractor is responsible for providing the special inspector access to approved plans and contract documents at the job site. All special inspection records shall be retained at the job site by the contractor and shall be made available to the Building Department upon request. Declaration by General Contractor 1, the General Contractor of the project, agree to comply with the "Contractor Responsibility" items noted above. Spencer SIominski Signature Date Special Inspection Reports: • Placement report, reinforcing steel report, and compressive strength testing report from 8/16/18 not provided. • Compressive strength testing report from 8-27-18 not provided. • Please submit all soil reports (sample pick-up, compaction, etc) Final Report form engineer/geo-tech as noted within permit conditions 10, 11, and 13 L&I electrical final approval Page 1 of 1 "W �Van&Associates, Inc_ Field Geotechnical Engineering.Environmental Engineering Report NO.:10618146DFRO7202018R'U Construction Testing and Inspection DATE: Set Count: CONTRACTOR: ERRG PROJECT#: 10618146 PERMIT W GRA2018-00003 PROJECT: North Ranch Surface Impoundment INSPECTOR: Bill Ugolini LOCATION: Union JURISDICTION: Mason Co. And Dam Saftey Office KA P.M.: WM WEATHER: overcast TEMP:60 Krazan Special Inspector onsite per request of Cedar of Parametrix. Purpose and Scope I was onsite for reinforcing steel inspection. I met with Cedar for a review of the contract documents and building permit. Findines Areas of inspection: Under drain encasement assembly from interior toe to exterior toe. Documents referenced: Sheet 2/ C10 by Parametrix. Reinforcing steel assembly consists of#5 long wise bars and#3 hoops at 36"on-center. Conclusion Reinforcing steel per contract documents and CRSI Guidelines. AUG 0 3 2018 615 W. Alder Street REVIEWED Reviewed B ""�' """'"°t 1 z�' °t n,gate ASTM Test#: Asset Number(s): To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: 13i,UL Ugo4i, Offices Serving the Western United States Lynnwood (425)485-5519 -Poulsbo (360) 598-2126 •Tacoma(253) 939-2500 The information provided ve dtis report is prepued for the a huive use of the client.This report may not be reproduced in any format i ithwt the written permissive of the chew and Krazan&Associates This report indicates on,inspectors observation and testing results based on site cooditiom and contractor activities.This information is subject to review prior to final submittal. B}signing this report.our inspector does not accept responsibilin for validity of result.The same information has been provided b�others on site. Page 1 of 1 """lean &Associates, Inc. Field Geotechnical Engineering- Environmental Engineering Report NO.: 10618146DFRO7242018DW Construction Testing and Inspection DATE: 7/24/2018 Set Count: CONTRACTOR: Parametrix PROJECT#: 10618146 PERMIT#: GRA2018-00003 PROJECT: Bio Recycling Corp North Ranch Surface INSPECTOR: David Wright LOCATION: 820 E Webb Hill Rd,Union,WA JURISDICTION: Mason County KA P.M.: Wes Mahan WEATHER: Clear TEMP:740 F As requested by Seter,I arrived onsite at the Bio Recycling Corp North Ranch Surface Impoundment project located at 820 E Webb Hill Rd,Union,WA.This report presents our purpose and scope of services,our findings,and conclusions. Purpose and Scope The purpose of our services,as requested by Seter,was to perform a concrete cylinder pickup.Five concrete compressive strength test cylinders had been previously cast by Bill Ugolini on July 23,2018. Findings All five cylinders were in-place at their initial set location and did not appear to have been tampered with or damaged. Conclusion The five cylinders were transported to our Poulsbo Lab for standard curin-and compressive strength testing. AUG 0 3 2018 615 W. Alder S6-Get REVIEWED Reviewed B : '""° °""""°"°' �'' '' ASTM Test#: Asset Numbers To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: / Offices Serving the Western United States Lynnwood(425) 485-5519 -Poulsbo (360) 598-2126 - Puyallup (253) 939-2500 The roformauon provided on this report is prepared far the exclusive use of the client.This report may not be reproduced in an m d format without the written permission of the client and Kraren E Associates This report mdtcates our inspectors obsenatiou and testing results based on site conditions and contractor activities.This information is subject to review prat to foul submittal.Fiv signing this repM,our inspector does not accept responuibilits for validih of results.The same information has been provided by others on site. a -� � &Associates, Inc. CONCRETE GEOTECHNICAE ENGINEERING-ENVIRONMENTAL ENGINEERING 10618146CR07232018W U CONSTRUCTION TESTING ANO INSPECTION REPORT NO.: DATE: Monday,July 23,2018 CONTRACTOR: Parametrix PROJECT#: 10618146 PERMIT#: - GP C7 Z41 S --evoo 3 PROJECT: North Ranch Surface Impoundment INSPECTOR: William Ugolini LOCATION: Union,WA JURISDICTION: Mason Co KA P.M.: Wes Mahan WEATHER: Sun TEMP: 84 Field Data Reported_Batch DATA ..., Concrete: �— XX Other �_� Cement Type 1/I I Design Actual Supplier: Miles Plant No. 224 Site Mix: Mix No. 025506 Cem lbs. Mix Temp Air Temp F.Ash Ibs Time Truck# Ticket# %Air Slump Inch (F) (F) Unit Weight C.Agg.Lbs. 3/4#57 166905 NT NT C.Agg.Lbs. C.Agg.lbs. Sand Ibs. CL 11 Placement Area Water Location: Underdrain encasement from interior toe to exterior toe. Admixture Admixture Admixture Air Ent. 02/cwt Water Added On Job Site Remarks: Concrete placed by boom pump and consolidated by mechanical (Gals) 0 vibration. 17 yards placed total. Field Test ASTM Method Please Refer To Field Report Number: 10618146DFRO7232018WU C143 p C138 ❑ C1064 E] C173 ❑ C31 El Other ❑ Inspector: William Ugolini Laboratory Data Design Strength 3000 @ 28 days Date Specimen Rec'd 7/24/2018 Cyl. Test Field Dia. Break Code Date Cure Age (in) Area C.F. Max Load Comp.Str,(psi) Set# Tested By Type Test Method C1736 7/30 7 3.99 12.50 53745 4300 EB 2 ASTM C39 C1736 8/20 28 4.00 12.57 72585 5780 EB 3 ASTM C109 ❑ C1736 8/20 28 4.00 12.57 69825 5560 EB 2 ASTM C617 0 C1736 8/20 28 4.00 12.57 70325 5600 EB 3 ASTM C1231 p C1736 H ASTM C1019 ❑ OTHER ❑ Test Results [D Conforming Remarks: ❑Non o Results Reviewed By: Date: 14 Codes for Break Type © ® ®® ® 1n I 1 2 3 4 5 6 PUG feet Offices Serving the Western United States `del s Lynnwood (425)485-5519 Poulsbo(360)598-2126 Puyallup(253)939-2500 6115\44' Concret Report Revision 11 Effective 02111/Zol3 The informabon prcv:dad on this report is prepay<a for the a}eWsive use a!the ctwm.This report mat not be reproduced m any format avithout the wneten pe[m'tsvon of the clnmt and Nratan&AtsatidtCs.This report indicates our inspectors observation and testing results based on site conditions and c hactor acdrvtties.This information is subject to revicm prior to heat submittal.BY signingti is report,our unpector does not accept responub+ley fervaWity,of the results.The same information has been prm:ided bvathers on site. { a a Y Page I of 1 —'KrOffan8tAssociates, inc. Field Geotechnical Engineering.Environmental Engineering Report NO.: 10618146DFRO7232018WU Construction Testing and Inspection DATE: Set Count: CONTRACTOR: Parametrix PROJECT#: 10618146 PERMIT#: GRA2018-00003- PROJECT: North Racch Surface Impoundment INSPECTOR Bill Ugolini LOCATION: Union JURISDICTION: Mason Co. KA P.M.: WM R: Sun TEMP: Krazan inspector on site per request of Cedar of Parametrix. Purpose and Scope I was onsite for concrete sampling and continuous inspection of concrete placement. I met with Drew of Parametrix for a review of the project plans and specifications and concrete mix design from Miles. Findings Areas of pour: Underdrain encasement from interior toe to exterior toe. Concrete placed by boom pump and consolidated by vibration. One concrete sample was taken and tested for slump and temperature,and one set of five 4"x8"test cylinders was cast for compressive strength testing. I observed the placement of 17 yards of concrete Mix#025506 supplied by Miles concrete. Cylinders placed in water bath under job shack. Reinforcing steel inspected on 7-20-2018 with Cedar Simmons. Conclusion Concrete placement per contract documents and ACI Directives. RECEIVE AUG U 3 2018 615 W. Alder Street REVIEWED Reviewed By: 1.'" "A""""°"''°° "'� �°'a ASTM Test#: Asset Numbe s : To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: 13 U L Ug o-(,i� Offices Serving the Western United States Lynnwood(425)485-5519 •Poulsbo (360) 598-2126 •Tacoma(253)939-2500 The information provided oe this report is prepared for the exchtsme use of the client.This report may not be reproduced in anv fame wahom the written permission of the client and Kr &Associates.This report indicates our inspectors obser,non and testing results based on site conditions and contractor aemities. This information is subjem to res m prior to fmal submmal. By signing this report.our inspector does not accept responsibility for validity of results.The same information has been prmided b%others on site. T I, Page I of 1 KraZan & ASsociates, inc. Field Geotechnical Engineering a Environmental Engineering Report NO.: 10618146DFR07252018WU Construction Testing and Inspection DATE: ' 018 Set Count: CONTRACTOR: ERRG PROJECT#: 10618146 PGRA2018-00003 PROJECT: North Ranch Bio Recycling INSPECTOR: Bill Ugolini LOCATION: Union,WA JURISDICTION: Mason Co_ KA P.M.: WM } ATHER; sunny TEMP: Krazan Inspector onsite per request of Cedar Simmons of Parametrix. Purpose and Scope I was onsite for reinforcing steel inspection,concrete sampling,and continuous inspection of concrete placement. I met with Drew Norton for review of approved contract documents and mix design. Findin6s Reinforcing steel was 4 each#5 bars longwise and#3 stirrups at less than 36"on-center. Spacing on west side of trench from steel to trench wall varied from I I"to IT'. On west side of trench was consistent at 3". HDPE Pipe met the 6"minimum clearance requirement from pipe to trench wall on east side of pipe. Areas of pour: Submerged inlet-outlet 12"HDPE with 48"manhole(cancelled at 12:30 M). Areas of new pour: Underdrain encasement from interior toe to exterior toe east side gap between previous pour and trench wall. Said gap varied from 3"to 6". Documents referenced: Sheet 2/C10 by Parametrix 5-30-218. Concrete placed by boom pump and consolidated by mechanical vibration. One concrete sample was taken and tested for slump and temperature,and one set of test cylinders was cast for compressive strength testing. I observed the placement of 11 yards of concrete Mix#025506 supplied by Miles Concrete.Please see Concrete Report 10618146CR07252018WU for the field test results and break dates. Conclusion Reinforcing steel per contract documents and CRSI guidelines. Concrete placement per project plans and specifications and ACI Guidelines. r— �?iz �._ AUG 0 3 2C18 615 W. Alder Street REWEWED Reviewed By: ASTM Test#: Asset Numbe s : To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: 13UL Ug&LZ4 -i, Offices Serving the Western United States Lynnwood (425)485-5519 •Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report ts prepared for the exclusive me of the client.This n:part inn.not be reproduced iu any format Without the Written permission of the client and Kra td As-ales.This report indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to review prior to final submmal.B}signing this report.our inspector does not accept responsibility for validity of results.The same information has been provided by others on site. 14 . .l - 4"Kr;aZ . &Associates, Inc. CONCRETE GEOTECHN CAL ENGINEERING�ENVIRONMENTAL ENGINEERING 10618146C RO7252018 W U CONSTRUCTION TESTING AND INSPECTION REPORT N 0.: DATE: Wednesday,July 25, 2018 CONTRACTOR: Parametrix PROJECT#: 10618146 PERMIT#: ��1C.��A19 DaD"57 PROJECT: North Ranch Surface Impoundment INSPECTOR: William Ugolini LOCATION: Union,WA JURISDICTION: Mason Co KA P.M.: Wes Mahan WEATHER: Sun TEMP: 80 Field Data Reported Batch DATA Concrete: XX -1 Other Cement Type 1 1/11 Design Actual Supplier: Miles Plant No. 208 Site Mix: Mix No. 025505 Cem lbs. 514 Mix Temp Air Temp F.Ash Ibs Time Truck# Ticket# %Air Slump Inch (F) (F) Unit Weight C.Agg.lbs. 3/4#57 1846 12:45 PM M014 167015 NT 5.75 79 80 N/A C.Agg.LIDS. C.Agg.Lbs, Sand Ibs. CL 11 1497 Placement Area water 29.5 Location: Underdrain encasement from interior toe to exterior toe.Gap Admixture between previous pour and trench. Admixture Admixture Air Ent. OZ/cwt Water Added On Job Site Remarks: Concrete placed by boom pump and consolidated by mechanical (Gals.) 1Q vibration. Concrete sampled at 11 yards of 11 total. Field Test ASTM Method Please Refer To Field Report Number: 10618146DFRO7252018WU C143 E C138 ❑ C1064 Ej C173 ❑ C31 � Other ❑ Inspector: William Ugolini Laboratory Data Design Strength F 3000 28 days Date Specimen Rec'd 7/26/2018 Cyl. Test Field Dia. Break Code Date Cure Age (in) Area C.F. Max Load Comp.Str,(psi) Set# Tested By Type Test Method C1743 8/1 7 4.00 12.57 48475 3860 EB 3 ASTM C39 Q C1743 8/22 28 3.99 12.50 57865 4630 EB 3 ASTM C109 ❑ C1743 8/22 28 3.99 12.50 58880 4710 1 EB 3 ASTM C617 ❑ C1743 8/22 28 3.99 12.50 56530 4520 EB 3 ASTM C1231 7 C1743 H ASTM C1019 ❑ OTHER ❑ Test Results 0 Conforming Remarks: ❑Non Conforming Results Reviewed By: t Date: Codes for Break Type G 1 2 3 4 5 6 1► offices Serving the Western United States Lynnwood(425)485-5519 Poulsbo(360)598-2126 Puyallup(253)939-2500 AUG :Oncret Report Revision 11 Effective 02/1/12013 l Street The vitormaUon.provided or thn report Is prepared for the exdUsive use o1 the cite nt.This report mat not be reptodueed In anyfprotat without a 6—Itto pertlnss "d!the Cl—:a^ -,�7r�l s. t'Mde s rtpf md-wits our Inspectors obse-;,tior=and testing results baseo on site cordro.,arw contractor scow is This informattor,is wbjW to rewew prior to furl submittal.By sitrtingthis report.our t cla does not recto: resp—shaty for validity of the rowits.The same tnformatior.has beenpr-ided by othars on site A % Page 1 of 1 *bra & A s s o c i a t e s, I n c_ Field lO6l 8146DFR07262018WU Geotechnical Engineering- Environmental Engineering Report NO.: Construction Testing and Inspection DATE: 7/26/2018 Set Count: CONTRACTOR: ERRG PROJECT#: 10618146 PERMIT#: GRA2018-00003 PROJECT: North Ranch Surface Impoundment INSPECTOR: Bill Ugolini LOCATION: Union JURISDICTION: Mason Co. KA P.M.: WM WEATHER: sun TEMP:60 Krazan inspector onsite for pick-up of concrete cylinders cast on 7-25-2018 by Bill Ugolini. Cylinders were retrieve from their initial set location and did not appear to have been tampered with or damaged. The cylinders were transported to our Poulsbo laboratory for standard curing and future compressive strength testing. R k- r- AUG 0 3 2018 615 W. Alderl j REVIEWED Reviewed B °r"°°"'aRNeOiOM°'z.am,�� Z°'° ASTM Test#: Asset Number(s): To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: 13i,(L Uga i,v>. Offices Serving the Western United States Lynnwood (425)485-5519 -Poulsbo (360) 598-2126 - Tacoma(253)939-2500 The information provided on this report is prepared for the exclusive use of the client.This report nra}not be reproduced in an,forma without the written pumission of the chew and Krarm&Associates.This report indicates our inspectors obsm ation and testing results based on site conditions and contractor activities.This information is subject to review prior to final submittal.By signing this report,our inspector does not accept rsponsibilitY for validity of rsults.The same information has been provided by others on site. "r Page 1 of 1 UKmzan &Associates, Field I n c. Geotechnica( Engineering . Environmental Engineering Report NO.: 10618146DFR07302018wU Construction Testing and Inspection DATE: 41111M018 Set Count: CONTRACTOR: ERRG PROJECT#: 10618146 PERMIT#: GRA2018-00003 PROJECT: North Ranch Surface Impoundment INSPECTOR: Bill Ugolini LOCATION: Union JURISDICTION: Mason Co. KA P.M.: WM WEATHER: sun TEMP:63 Krazan Special Inspector onsite per request of Cedar Simmons of Parametrix. Purpose and Scope I was onsite for reinforcing steel inspection,concrete sampling,and continuous inspection of concrete placement. Findines Steel reinforcement was inspected. Stirrups placed at less than 36"on-center with 4 each#5 bars at the 90 degree bends #3 stirrups. Clearances have been maintained by use of dobies to keep the 3"clearance from steel to earth per ICC and 6"from earth to 12"HDPE per Parametrix. Areas of concrete pour: Submerged inlet-outlet 12"HDPE encasement pour. Documents referenced: Sheet 2/C10 by Parametrix dated 5-30-2018. Concrete placed by boom pump and consolidated by vibration. One concrete sample was taken and tested for slump and temperature,and one set of five 4"x8"cylinders was cast for compressive strength testing.I observed the placement of 41 yards of concrete Mix#026026 supplied by Miles. Conclusion Reinforcing steel placed per contract documents and CRSI Guidelines. Concrete placement per contract documents and ACI Guidelines. JUL 3 12018 ;t w. Alder Street REVIEWED Reviewed By. ASTM Test#: Asset Numbe s : To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: 13 U,L Ug o-{.i 4� Offices Serving the Western United States Lynnwood(425)485-5519 -Poulsbo (360) 598-2126 •Tacoma(253)939-2500 The information provided on this report is prepared for the exclusive use of the client This report may not be reproduced in m}'format without the written permission of the client and Kraran&Associates. Thu report indicates our inspectors observation and testing results based on site conditions and contractor activities.Tbis information is subject to revim prior to final submittal. B)signing this report.our inspector does not accept responsibility for validity of results.The same information has been provided bi others on site. 1*"KrazM 8E Associates, Inc. CONCRETE GEOTECHIOCAL ENGINEERING-ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION REPORT NO.: 10618146CR07302018WU DATE: Monday,July 30,2018 CONTRACTOR: ERRC PROJECT#: 10618146 PERMIT#: 1111111111111111110 PROJECT: North Ranch Surface Impoundment INSPECTOR: William Ugolini LOCATION: Union,WA JURISDICTION: Mason Co KA P.M.: Wes Mahan WEATHER: Sun TEMP: 63 Field Data Reported Batch DATA Concrete: XX Other Cement Type 1/II Design Actual Supplier: Miles Plant No. 208 Site Mix: Mix No. 0260A6 Cem lbs. 562 Mix Temp Air Temp F.Ash Ibs Time Truck# Ticket# %Air Slump Inch (F) (F) Unit Weight C.Agg.Lbs. 3/4#57 1894 6:35 AM M0971 167049 NT 5.5 79 63 N/A C.Agg.lbs. C.Agg.Lbs. Sand Ibs. CL 11 1373 Placement Area Water Location: Submerged inlet-outlet 12" HDPE with 48" manhole Admixture poly997 3.4 Admixture MBAE90 2.5 Admixture Air Ent, OZ/cwt Water Added On Job Site Remarks: Concrete placed by boom pump and consolidated by mechanical (Gals.) vibration. Concrete sampled at 10 yards of 41 total. Field Test ASTM Method Please Refer To Field Report Number: 10618146DFRO7302018WU C143 C138 ❑ C1064 C7 C173 ❑ C31 p Other ❑ Inspector: William Ugolini Laboratory Data Design Strength 2500 @ 28 days Date Specimen Rec'd 7/31J2018 Cyl. Test Field Dia. Break Code I Date Cure Age (in) Area C.F. Max Load Comp.Str,(psi) Set# Tested By Type Test Method C1748 8/6 7 3.99 12.50 54910 4390 EB 3 ASTM C39 2] C1748 8/27 28 3.99 12.50 62935 5030 EB 2 ASTM C109 ❑ C1748 8/27 28 4.00 12.57 61010 4860 EB 3 ASTM C617 ❑ C1748 8/27 28 3.99 12.50 64240 5140 EB 3 ASTM C1231 R C1748 H ASTM C1019 ❑ OTHER ❑ Test Results {y Conforming Remarks: ❑Non Conforming Results Reviewed By: V Date: Z /°v ie Codes for Break Type ® ® ®® ® no "" 1 2 3 04 5 6 raps et Offices Serving the Western United States p� P\60 Stje Lynnwood(425)485-5519 Poulsbo(360)598-2126 Puyallup(253)939-2500 Yy NJ. Concret Report Revispn ll Eftectiye 02f1043,� The"formatmn prov!oee on this repott!s prepared for tee exUes!ye_wof the dent.TMs report that not be reproaUced In any for niat wtthoLt the written permission of the clicrt and Kratar rs Associates.This mpdrt rndKMes oo*;nspecto pbservm—and testing re.Itt based on I'M<ondd.n atm tpnfrattdr aw0t.,This nform t,or.R subject co rewew prior to frnat xuL mttal.By s!gning this report,our inspector^e ^:o;accept responsibility,fo*validity pf the resutts.The same u!formm—has been pr av d brothers or:sit.. ,r . N Page 1 of 1 "&sAQ 1(raLZa1&A s s o c i a t e s, I n c. Field 10618146DFR08022018EB Geotechnical Engineering-Environmental Engineering Report NO.: Construction Testing and Inspection DATE: 8/2/2018 Set Count: CONTRACTOR: PROJECT#: 10618146 PERMIT#: PROJECT: North Ranch Bio Recyccing INSPECTOR: Elizabeth Basler LOCATION: 820 E Webb Hill,Union,WA JURISDICTION: Mason Co. KA P.M.: Wes Mahan WEATHER: Sunny TEMP:79"F As requested by Cedar,I arrived onsite at the Bio Recycling Corporation North Ranch Surface Project located at 820 E Webb Hill,Union,WA.This report represents our purpose and scope of services,our findings,and conclusions. Purpose and Scope The purpose of our services was to perform a concrete cylinder pick-up.One set of five concrete compressive strength test specimens had been cast on July 30,2018 by William Ugolini. Findines The five concrete cylinders were in-place at their initial set location and did not appear to have been tampered with or damaged. Conclusion I transported the concrete cylinders to our Poulsbo Lab for standard curing and future compressive strength testing. �liO T0111- S�teek 6`N.P�det Reviewed By: ASTM Test#: Asset Numbe s : To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood(425)485-5519 -Poulsbo (360) 598-2126 -Tacoma(253) 939-2500 The information provided on this reports prepared for the exclusive use of the client.This report in-trot be reproduced in my fame without the written permission of the client and F:raran$Associates.This report indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to review prior to furl submihal.B�signing this report,our inspector does not accept responsibilih for validity of results.The same information has been provided by others on site. Parametrix ENGINEERING.PLANNING,ENVIRONMENTAL SCIENCES 60 WASHINGTON AVENUE,SUITE 390 1 BREMERTON,WA 98337 I P 360.377.0014 TECHNICAL MEMORANDUM DATE: September4, 2018 RcpI 2O TO: Brian Hickey and Roger Hickey—Bic Recycling Corporation Z%_4 Sueet FROM: Steve Wagner,S.E.—Parametrix SUBJECT: Development of North Ranch Surface Impoundment rp1 CC: Cedar Simmons—Parametrix PROJECT NUMBER: 216-7573-001 (02/02) PROJECT NAME: Air Content of Pond Discharge Concrete Pour This Technical Memorandum is to address the non-conformance noted in Krazen &Associates Field Report number 10618146DFRO8162018WU regarding testing done for the concrete pour on August 16,2018. This pour was for the"Submerged Inlet/Outlet" structure shown on Drawing S1.The discrepancy noted was on the air entrainment, which was measured as 3%against the 6%which was specified. No other field test indicated any other problems with the concrete being supplied. I was contacted by Drew Norton of Parametrix when this test result was taken and gave the OK to continue the pour.The lower air content is not a concern to me as the primary purpose for the entrained air is to increase durability of the concrete due to freezing in exposed locations such as pavements.This particular concrete was for a structure that will be protected under the pond liner and not exposed to weather. Per American Concrete Institute and Portland Cement Association publications, the main functions of air entrainment are durability and to make the concrete more workable during placement. Addition of air content actually reduces concrete strength, and this is compensated in the mix design by adding cement content.Thus, I have no concern for the air content being detrimental to the strength of the concrete, unless shown as deficient due to other reasons in the up-coming cylinder tests. We will review the 7-day and 28-day break results to confirm that the quality of the concrete poured is acceptable. p,LANT h G 18711 �3(?RTAL 7/j_/ze/& 9NON-CONFORMANCE _ Air content of concrete did not inset Page 1 of 1 nrojec cation G= � &Associates, Inc. Field Geotechnical Engineering.Environmental Engineering Report NO.: 10618146DFRO8162018WU Construction Testing and Inspection DATE: 8/16/2018 Set Count: CONTRACTOR: ERRG PROTECT#: 10618146 PERMIT#: PROTECT: Bio Recycling Corp.North Ranch INSPECTOR: Bill Ugolini LOCATION: Union JURISDICTION: Msson Co. KA P.M.: WM WEATHER: overcast TEMP: Krazan Inspector onsite per request of Drew of Parametrix. Purpose and Scope I was onsite for reinforcing steel inspection,concrete sampling,and continuous inspection of concrete placement. I met with Drew for a review of the contract documents and mix design. Findings Areas of pour: Submerged inlet-outlet-north end. Documents referenced: S 1 drawing 20 of 25 by Parametrix. Steel reinforcement placed at 6"on-center for#3 bars at base and walls.4 each #5 bars at horizontal placed over future pipe channel. Concrete placed by boom pump and consolidated by vibration. One concrete sample was taken and tested for slump, temperature,air content,and one set of five 4"x8"test cylinders were cast for future compressive strength testing.I observed placement of 5 yards of concrete Mix#0260A6 supplied by Miles Concrete. Note on concrete: Specification by Parametrix call for 6%air content. Concrete tested at 3.0%air content. All parties were notified as soon as the testing was complete. I notified Rick of EERG,the concrete subcontractor,and Drew of Parametrix. Conclusion. Reinforcing steel per contract documents.Concrete placement per project plans and ACI Guidelines,with the exception of the air content as noted above. RECENEL AUG 3 0 20113 615 W. Alder Street REVIEWED Reviewed B : my-RNamaaatr-so.mrs ASTM Test#: I I Asset Number s To the best of my knowledge,the above WAS N performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: 6UL ugo-Li,H,i, Offices Serving the Western United States Lynnwood(425)485-5519 -Poulsbo (360) 598-2126 •Tacoma(253) 939-2500 The information provided on this report is prepared for the exclusive use of the client.This report riary not be reproduced m anc format without the wriden permission of the client and Kraran&Associates.This repon indicates our inspectors observation and testing results based on site conditions and contractor activities.This information u subject to revim prior to fmsl submittal.B%signing this report.our inspector does not accept responsibihtn for validity of results.The same information has been provided b}others on site. ti CONCRETE `= _�aZM&Ass o c i ate s, Inc. REPORT NO.: 10618146CRO8162018WU Geotechnical Engineering•Environmental Engineering Construction Testing and Inspection DATE: 8/16/2018 CONTRACTOR: ERRG PROJECT#: 10618146 PERMIT#: PROJECT: Bio Recycling Corp. North Ranch INSPECTOR: William Ugolini LOCATION: Union JURISDICTION: Mason Co. KA P.M.: WM WEATHER: overcast TEMP: Field Data Reported Batch DATA Concrete: X Other: Cement Type Supplier: Miles Plant No. 208 Site Mix: Design Actual Slump Mix Air Unit Mix No. 0260A6 Time Truck# Ticket# %Air Inch Temp(F) Temp(F) Weight Cem.Lbs. 562 \ H R29 1 167208 3.0 1 2.75 78 ° 64° NA F.Ash lbs. C.Agg.Lbs C.Agg.Lbs C.Agg.Lbs 7/8#57 1855 Placement Area Sand lbs Class 2 1267 Location: Submerged inlet-outlet north end. water Admixture Poly 997 34.4 Admixture MB AE90 2.4 Admixture Air Ent. (oz/cwt.) Water Added On Job Site Remarks: Concrete placed by boom pump and consolidated by (Gals.) 0 mechanical vibration. Sampled at 5 yards of 5 yards total. Field Test ASTM Method Please Refer To Field Repot Number: 10618146DFRO8162018BU C172 C143 C138 C1064 C231 Inspector: Bill Ugolini C31 Other Laboratory Data Design Strength: 4000 @ 28 days Date Specimens Re Cyl. Test Field Wt. Max Comp. Set Tested Krk Test Method Code Date Cure Age Dia. Area # Load Strength # By Typ ASTM C39 8/23/18 7 ASTM C 109 9/13/18 28 ASTM C617 9/13/18 28 ASTM C 1231 9/13/18 28 ASTM C 1019 H OTHER Test Results Remarks:1 Air content was low-6% needed Results Reviewed By: Date: Codes for Break Types ---72 4_j 5;_ . ' Offices Serving The Western United States Concrete Report Effective 0212 2/2 0 1 8 Lynnwood(425)485-5519 • Poulsbo(360) 598-2126 • Tacoma(253)939-2500 The bAormation prwieetl m Inis rep«t¢preperee for uie eslvene ree d the cY«d,one may rqt be repr°eicee n anY forma wtrioit the wrRlen perenKsan W the Gi«it arN K2zan&Assaci�a Ths repM indcata our repacta s observation one tatmg rauMs Dave m sile c°rmei«s one m.xr:«any.rng nr«maron sugea o rmw w«m nw submmr.er ere«ne m5 report.w trspea«eoa nor aueq rabaey t«�a+r d rain.Tne­nr«matwn tms teen awaee br anus m see. Page 1 of 1 -- �� &Associ ate s, inc. Field Geotechnical Engineering.Environmental Engineering Report NO.: 10618146DFRO8172018DW Construction Testing and Inspection DATE: 8/17/2018 Set Count: CONTRACTOR: Parametrix PROJECT#: 10618146 PERMIT#: GRA2018-000031 PROJECT: Bio Recycling Corp North Ranch Surface INSPECTOR: David Wright LOCATION: 820 E Webb Hill Rd,Union,WA JURISDICTION: Mason County KA P.M.: Wes Mahan WEATHER: Overcast TEMP:71°F As requested by Seter,I arrived onsite at the Bio Recycling Corp North Ranch Surface Impoundment project located at 820 E Webb Hill Rd,Union,WA.This report presents our purpose and scope of services,our findings,and conclusions. Purpose and Scope The purpose of our services,as requested by Seter,was to perform a concrete cylinder pickup.Five concrete compressive strength test cylinders had been previously cast by Bill Ugolini on August 16,2018. Findings All five cylinders were in-place and did not appear to have been tampered with or damaged. Conclusion The five cylinders were transported to our Poulsbo Lab for standard curing and future compressive strength testing. TO REVIEWED Reviewed B .erm.,rR awaa.a.'.asaa•ap*''°r'ASTM Test#: Asset Numbers : To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425)485-5519 -Poulsbo (360) 598-2126 -Puyallup(253)939-2500 The information provided on this report is prepared fa the exclusive use of the client.This report mad not be reproduced to=3 format without the written permission of the client and Kra &Associates.Tiffs report indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to r—cu prior to final submittal. B.signing this report,our inspector does not accept rmpons bility for validity-of results.The same information hu been provided h�others on site. Page 1 of 1 1(r2VM&Associates, lnc. Field Geotechnical Engineering•Environmental Engineering Report NO.:10618146DFR8272018BU Construction Testing and Inspection DATE: 8/27/2018 Set Count: CONTRACTOR: ERRG PROJECT#: 10618146 PERMIT#: GRD2018-00003 PROJECT: Bio Recycling Corp North Ranch INSPECTOR: Bill Ugolini LOCATION: Union JURISDICTION: Mason Co. KA P.M.: WM WEATHER: Sun TEMP:80s Krazan Inspector on site per request of Drew of Parametrix. Purpose and Scope Krazan I on site for reinforcing steel inspection,concrete sampling,and continuous inspection of concrete placement. I met with Drew for a review of the contract documents and mix design. Findings Areas of pour: Submerged inlet/outlet assembly. Documents referenced: S 1,20 of 25 by Parametrix. Concrete placed by excavator bucket and consolidated by vibration. One sample was taken and tested for slump, temperature,air content,and cast 1 set of 5 each 4"X8"test cylinders for compressive testing. Observed placing of 3 yards of mix#025506 supplied by Miles Concrete. Conclusion Concrete placement per contract documents and ACI. Reinforcing steel per contract documents and ICC. FG� 01� SVeek Reviewed By: ASTM Test#: Asset Numb s : To the best of my knowledge,the above WAS performed in accordance with the approved plans,specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425)485-5519 - Poulsbo(360) 598-2126 - Tacoma(253) 939-2500 The information provided on this report is prepared for the exclusive use of the client.This report ma)-not be reproduced in any format without the written permission of the client and Kr &Associate. This report indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to review prior to final submttid By signing this report,our inspector does not accept responsibiiit%for validm of results.The same information has been p—ded by others on site.