FIR2007-00041 Final Bldg 3 AFA - FIR Permit / Conditions - 10/31/2008
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton,WA 98584 FIRE PROTECTION PERMIT FIR2007-00041 APPLICANT: MASON COUNTY PUBLIC WORKS RECEIVED: CONTRACTOR: 12/14/2007 TAURUS INDUSTRIES 754�491 LICENSE: TAURU11011L1 EXP: 9/5/200 SITE ADDRESS: 100 W PUBLIC WORKS DR BLDG E SHELTON ISSUED: PARCEL NUMBER: 420021000010 EXPIRES: LEGAL DESCRIPTION: PCL 2 OF BLA 06-72 PROJECT DESCRIPTION: Automatic fire alarm- Building 3-Sign Shop and Equipment GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 11 Flow Switches: Visual Devices: Door Releases: Hood&Duct?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: N Wet Chemical?: N Zones: Heat Detectors: Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:()_ Second Floor: Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Permit $150.00 $0.00 Auto. Fire Alarm Plan $97.50 $0.00 Total: $247.50 $0.00 FIR2007-00041 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FIR2007-00041 CONDITIONS FOR FIR2007-00041 1.) The fir alar system m t be in compliance with NFPA 72 and be fully monitored by a UL certified monitoring company. X The equipment a e appurtenances need to be compatible and installed to the manufactures installation specifications. A copy of the manufactures installation splecifications need to be on site for all inspections. X Two out side dedicated phone lines are required. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a pro gress-trt"spection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The ownerofth'agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure forand inspection. OWNER OR AGENT: DATE: l s : FIR2007-00041 Please refer to the following pages for conditions of this permit. 2 of 4 -n 56 CONCRETE MECHANICAL MANUFACTURED HOME > IN) —_ --- U) Q Footings !Setbacks By 0 (D Gas Piping Ribbons 4 Interior Date By Interior-Date By Gate z 6 0 QC) Extenoir Date By Exterior- Date By Set-up 0 - - - INSULATnldk C Point Load I Isolated Footings Uati, 8v z Cate B y BG I SLAB INSULATION Dato By FIRE DEPARTMENT Foundation Walls Floors Dante Date By DECKS Date By co FRAMING Walls Walls Da"O' By By Data t 11"'y PROPANE TANKS PLUMBING Vault Uotu i3.y 0 Daley X OTHER X Groundwork Attic (n Oato By Date By Type. Date B y D.W. DRYWALL Type- r Int.Brace Wall Date By (D 9!e By Daft , By FINAL INSPECTION (D Water Line Fire Separation C) Date By Date By Date By CD CD 0 Pass or Request Inspect. CD Type of Insp. Fail Date Date Done By Comments CID 72 0 0 :3 W 0 3 0 MASON COUNTY FIRE MARSHAL Mason County Bldg. III 426 W Cedar St PO BOX 186 Shelton,WA 98584 (360)427-9670 Ext.273 Permit # Mason County Fire Protection System Permit Application Incomplete application will not be accepted Owner: , o 41 Tt4)1 i ca Phone #: Mailing Address: Y ,S Al. (o-ft ST City:5he.j&n State:U Zip: gs5-89 Site Address:j jg1,5 Dn l.rf"on >4 rUorf h` D City: 3,hejioyj State:L�R Zip: y?,,� Parcel /�. c-�(-c its Legal Description:,�',ec-_ .2 j,)(1Af. 'A 21 kf Lien/Title Holder: / -)QZ1 n n'-Ic t.il " Address: City: State: Zip: Contractor: rt uru�, Thc�1 4-t lam` `T r,f° . Phone#:(3I o)I54-$y 91 Address: 1C?.3 , 7 ' AVE s E City: n�mp;cj State: Zi aal�_ p: 98501 Contractor Registration #: iLl P,0 Expiration Date: 1 ho I n y Building Square Footage (existing&proposed): 1" 2nd / 3rd / Building Use: Nc !� S,a n ,Sho Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet Dry New System: Standpipe: Wet Dry Modification. AFA: Hood &Duct: Dry Chem: Wet Chem: Fire Pump: UL certified Monitoring company: Phone #: Contractors Bid Price: $ 1 ,j®b . 0 C) \\CLUSTERI_HOME_SERVER\HOME\COMMON\BUILDING\Fire Protection System Permit A lic .y r' stun ioc Plan Submittal Requirements Your plan submittal shall include the following: • Plans shall be on standard 24" x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls, partitions, stairway enclosures, concealed spaces, etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits, devices, and end—of— line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$100.00. A plan review fee will be calculated at 65% of the permit fee and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a cutxe registered contractor in the State of Washington. I am aware of the uixem ordinance red ``e� g nts regulating the work for which the permit is issued and certify that all work wiy.)de in compliance with this ordinance. No changes will be made without first obtaining appr?YAl from the Mason County Fire Marshal. By: -Bruce Towhe Date: Taurus Industries, Inc. President PROJECT MASON COUNTY PUBLIC WORKS MAINTENANCE FACILITY HELIX PROJECT # A05-081 DATE December 13, 2007 CONTRACTOR ROGNLIN'S INC PO BOX 307 ABERDEEN WA 98520 (360) 532-5220 PHONE (360) 52-5761 FAX OWNER MASON COUNTY PUBLIC WORKS PO BOX 1850 SHELTON WA 98584 (360) 427-9670 PHONE SUB-CONTRACTOR TAURUS INDUSTRIES INC. 1036 73RD AVE SE OLYMPIA WA 98501 (360) 754-8491 (360) 352-0368 FAX SUBMITTAL PACKAGE FIRE ALARM BLDG 3 1 MASON COUNTY PUBLIC WORKS MAINTENANCE FACILITY HELIX PROJECT #A05-081 TABLE OF CONTENTS BUILDING THREE (A) EXPANSION MODULE (B) SMOKE DETECTORS (C) PULL STATIONS (D) M.I.M.S (E) HORNSTROBES AND STROBES (F) BATTERY CALCULATIONS (G) DRAWINGS k.vURTESY OF TAURUS INDUSTRIES INC.1036 73RD AVE SE 12/13/2007 OLYMPIA WA 98501 (360)754-8491 phone (360)352-0368 fax A EXPANSION MODULE i INTELLIKNIGHT ACCESSORY Model 5895XL Intelligent Power Module I The intelligent way to distribute power throughout your installation. With 6.0 amps of output power, six programmable FlexputT"" I/O circuits, and two Form C relay contacts, the Model 5895XL Intelligent Power Module allows you to greatly enhance the capabilities of an IntelliKnight system, distributing power where needed throughout a facility. 5895XL modules connect via the RS-485 system bus. Up to eight 5895XL modules can be used per IntelliKnight system. Each 5895XL has its own optically isolated RS-485 bus to which other modules, such as 5860 remote annunciators and 5824 printer interface modules, can be connected. You can also connect 5815XL SLC expansion modules, adding flexibility and wiring distance. Each 5895XL supports its own backup batteries and monitors the AC power. Description • Up to 6,000 feet wiring distance 5895XL adds 6.0 amps of power, from 5895XL(same distance as six Flexput 1/0 circuits, and two main FACP) Form C relay circuits to an • Battery charging capacity 35 Ah IntelliKnight installation. The 5895XL is optically isolated • Large cabinet can house two 18 providing ground loop isolation and Ah batteries or RBB accessory transient protection. The 5895XL cabinet can house battery sizes conditions the RS-485 system bus larger than 18 Ah allowing up to an additional 6,000 • Room in FACP cabinet to mount feet of wiring. two 5815XL SLC expanders Operation • Built-in synchronization for The green LED on the 5895XL appliances from AMSECO , board indicates communication with Gentex®, Faraday, System the IntelliKnight FACP.' Sensor@, and Wheelock@ The Flexput circuits can be notification appliance circuits, Electrical Specifications continuous power, resettable Primary AC: power, door holder power or 120 VRMS @ 60 Hz, 2.5A initiation circuits that can support 240 VRMS @ 60 Hz, 1 AA both 2- and 4-wire smoke Total Accessory Load: detectors. All Flexput circuits and 6A @ 24 VDC relay outputs are individually Current: mappable from the IntelliKnight Standby: 40 mA 5820XL FACP. Alarm: 160 mA Model 5895XL Features 1/0 Circuit Power: • 6.OA output power 3A per circuit (6A total per system) Approvals • Flexput 1/0 circuits, 3A each, Mechanical Specifications NFPA 13, NFPA 15, NFPA 16, programmable as notification Flush or surface mount NFPA 70, NFPA 72 and circuits, auxiliary power circuits, Dimensions: NFPA 101 or initiation circuits 14-1/2"W x 24-3/4"H x 3-7/8"D UL 864 • Supports Class A configuration (36.8 W x 62.9 H x 9.8 D cm ) CSFM for SBUS & Flexput circuits Overall Dimensions: 16-1/8"W x 26-3/8"H x 4-1/8"D MEA 429-92-E, Vol. IX • Ground loop isolation (40.6 W x 67 H x 11.8 D cm) • 2 Form C programmable relays Color: Red FM approved rated at 2.5A at 24 VDC • Transient protection Environmental SILENT Operating Temperature: KNIGHT • SBUS repeater conditions the 32°F — 120OF (0°—49°C RS-485 signal Humidity: 10% —93% L3 non-condensing by Honeywell INTELLIKNIGHT ACCESSORY Model 5895XL Intelligent Power Module Engineering Specifications The contractor shall supply a power module compatible with the IntelliKnight Model 5820XL FACP. The power module must have 6.0 amps of output power, Flexput 1/0 circuits rated 3.0 amps each, and two Form C relay contacts rated at 2.5 amps at 24 VDC. The power module shall connect to the main FACP via an RS-485 system bus (SBUS). The power module shall contain an additional RS-485 bus that is completely compatible with all IntelliKnight add-on modules, including 5815XL SLC expanders, 5860 remote annunciators, 5824 serial/parallel printer interface modules. The power module RS-485 bus shall be optically isolated providing ground loop isolation and transient protection. The unit shall be an SBUS repeater that conditions the signal driving up to 6,000 feet of additional wiring. 5820XL FACP 5895XL -- - -- - ' � MAIN SBUS IN' OUT 23 22 21 20 19 18 17 16 33 32 31 30 23 22 21 20 19 18 17 16 + A B - + A B + A B + A 8 + A B NACs,Auxilary ; SLC Power,etc. -- - _ _- _._ -- - - - -- 5824 5860 Used in Used in To Next 3 Class A Class A SBUS Device D z configurations Up to 6,000 Feet,Non-shielded Configurations D 5895XL Connection to FACP z m r- rn _ 07 C rn NACs,Auxilary Power,etc. NACs,Auxilary Power,etc. 5895XL-1 SBUS 5895XL-2 SBUS To Next 5895XL 5860 5860 5824 SLC SLC 5895XL Installation Example SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350212 Rev.C,02/06 by Honeywell subject to change without notice. For more information,contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927 Copyright©2006 Silent Knight Phone: (800)328-0103, Fax: (763)493-6475 IntelliKnight is a Registered Trademark of Silent Knight Flexput is a Trademark of Silent Knight B SMOKE DETECTORS INTELLIKNIGHT ACCESSORY I � N Addressable t� Photoelectric otoel ectric Type Smoke Detector Detect smoldering fires quickly and get AV r;. help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog /Addressable an electronic signal. Under normal . Photoelectric Type conditions, the status LED blinks Smoke Detector approximately every 15 seconds, The SD505-APS is particularly indicating that the head is %ft 00 suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. L3.-, foam or other similar materials which tend to smolder and produce Features large visible particles. • Low profile, 2 inches, including SD505-APS Smoke Detector base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17-41 VDC compensation for contamination without mechanical switches and a simple detector calibration Current Consumption: • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the . Built-in fire test feature Alarm: .55 mA WindowsTM based downloading Ambient Temperature: software). Simple detector calibration 32°F to 120°F testing through the control panel (0°C to 49°C) Operation or remotely through a Mounting: 4"Square, 4" The SD505-APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal-resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light . Field cleanable from the pulsing light source. In the Air Velocity: 0 300 FPM • UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505-6AB detector and light is reflected from (Sold Separately) (6" Base) the smoke particles to the receiving CSFM approved SD505-4AB element. • MEA approved (4°Base) • FM Approved SILENT 10 KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of,combustion in the chamber to ensure testing of detector circuits. Diameter=5-15/16" \ Diameter=3-15/16" u 0 c : = o Height=2 inches \.. including base a����KNI(3R Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA r KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350225 Rev C,.05/05 subject to change without notice.For more information,contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone: (800)328-0103, Fax: (763)493-6475. c i PULL STATIONS INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station i IntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means eans of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds.up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA , • Corrosion-resistant gold-plated Addressable Pull contacts. • Reflective label makes it easier Station to locate in low light The SD500-PS is a single action Operation addressable fire pull station, and The SD500-PS/PSDA single action the SD500--PSDA is a.dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32`F to 120`F • UL Listed communicating with the loop. The (o°C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box -• ADA compliant the addressable module is used to Optional Red Surface Mount Box PS-SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) • Surface mount back box Specifications Operating Voltage: 24VOC available SILENT Standby Current: .55mA • Terminals - accept up to 14 Alarm Current: .55mA KNIGHT gauge wire INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. .R ♦ FA.','P ` 3 `q Wiring i 3 21T Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box i i SD500-PSDA ' � h 6eclncal 8m mue oe Installing SD500-LK Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350342, Rev.09/03 •FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2003 Silent Knight D MIMS ACCESSORYINTELLIKNIGHT l - .' Model SD500-AIM WV i Addressable Input Module And Model SD500-MIM Miniature Input Module KEY ti Intellil(night's addressable contact monitor modules combine fast response with pin-point location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight's IntelliKnight fire control panel. The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability an well as eas P y d pleasing a y Installation and stable P g esthetics as able operation—a flexible solution for all your fire protection needs. Model SD500-AIM and SD500-MIM Input Modules The addressable input modules expand the flexibility of the IntelliKnight system by allowing the use of contact type inputs. Typical applications include manual pull wr� stations and water flow switches. l Features �` g • Operates on Class A(Style 6 & Style 7)or Class B (Style 4)SLC Loop. — — Single contact monitor. SD500-AIM SD500-MIM • Up to 127 modules per SLC loop. • SD500-MIM mounts in a single gang Operation box. Specifications Each addressable input module is Operating Voltage: 24 VDC • SD500-AIM mounts in a programmed with a unique SLC 4"-square or double gang electrical loop address. The module Standby Current: 0.55 mA box, and has an attractive ivory supervises the wiring to the contact Alarm Current: 0.55 mA cover plate. with an End Of Line (EOL) resistor. perature: 32°i=to 120T • SD500-AIM/MIM are DIP switch Ambient Tem programmable. If a fault occurs in the wiring, the (o°C to 49°C) module alerts the FACP. Mounting: sD500-AIM • Accepts up to 14 gauge wire. • Both modules UL 864 listed; comply double gang box or with NFPA 72 4"-square electrical • 2500 ft max. wiring distance from box input module to contact. SD500-MIM CSFM listed. single gang box • • MEA 429-92-E, Vol. 9 CTT • FM approved SILENT 13. KNIGHT INTELLIKNIGHT ACCESSORY Model SD500-AIM and SD500-MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate. Model SD500-AIM FRONT VIEW BACK VIEW SIDE VIEW I U O p f�1+ O 1' Model SD500-MIM 2.112" SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350231, Rev. 11/01 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2001 Silent Knight E HORN STROBES AND STROBES � )•��.�1 'fit���<4 ;{?1f C Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications S E R I E S The Commander3 Series is a low profile strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30. 60, and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for f the professional to changa in the field by using switches. The GE3 Series has a minimal operation current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander3 Series is shipped with the standard 4" mounting plate which Product Listings incorporates the popular Super-Slide'M feature that allows the installer to easily test for supervision. The product also features a locking mechanism which (�` 11S F M secures the product to the bracket without any screws showing. APPROVED —- Th..y.-mew�I�w��rr.I .n.I,o,M, k The Commander3 also features the Checkmate'M- Instant Voltage Verification L sw by UNDERWRITERS LABOPATORiES INC feature which allows the installer to check the voltage drop draw and match it to BFP(City of Chicago) the blueprint. BS+A/MEA#285-91-E • CSFM 7135-0569:122(GEC3-24&GEH-24) The GE3 Series appliancE.s are UL 464 and UL 1971, listed for use with fire pro- 7125-0569:123(GES3-24) p 7125-0569:129(GES3-12) tective systems and are warranted for three years from date of purchase. 7135-0569:130(GEC3-12&GEH-12) Standard Features • FM Approved • UL 464&UL 1971 Listed • Nominal Voltage 12 & 24 VDC • CAN/ULC S526-M87 Listed • 24 VDC units have field selectable candela options of ULSZ7.S3406 Listed(GEC3-24, 15, 30, 60, 75, and 110 candela GEH24&GE1112) • 12 VDC units have field selectable candela options of Product Compliance 15, 30, 60, and 75 candela • NFPA 72 • GEH horn is available in 12 or 24 Volt • Americans with Disabilities Act(ADA) • Super-SlideTM Bracket- Ease of Supervision Testing • Checkmate"' - Instant Voltage Verification • Unit Dimensions: 5" h'gh x 4.5" wide x 2.5" deep MEMBER A59£M•tE N • Synchronize Strobe anti/or Horn with Gentex Series 1,.. Control Module (12 Vol; product must use the AVSM • Switch for Continuous or Temporal 3 (not available on Module) whoop tone) ' • Prewire Entire System, Then Install Your Signals • Surface Mount with the GSB (Centex Surface • Lower Installation and Operating Costs Mount Box) • Input Terminals 12 to 18 AWG • Silence Horn While Strobes Remain Flashing • Switch Selection for High or Low dBA • Wide Voltage Range 8-17.5 VDC (12 Volt Models) • Switch for Chime, Whoop, Mechanical and 2400Hz Tone 16-33 VDC or FWR (24 Volt Models) • Tamperproof Re-entrant Grill • Faceplate Available in Red or Off-White GEH 12 or 24 Volt Low Profile Evacuation Horn Model um er Part um er omma Reverberant n nec oic Room Voltage 1Oft. Per UL 464, dBA @loft. 100 1 -1 1 2 1 00 -1 5 7_ _ 1 00 GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe Model um er art um jerTiVoiltage Nominal (UL 1971) Model designations- 15, 77T 75 "W" = Wall Mount 5, 30, 67 75 "R" = Red Faceplate 5 "W" = Off-White Faceplate 9 -1 0 15, 30, 67 75 'P" = Plain (no lettering)Available -1 1 15, 30, 60-, 777717- with all models. -1 5, 30, 60, 75711 These units are non-returnable. 1 2 2 15, 30, 60, 75711 "Agent" bezel also available. 1 0 15, 0, 75, 11 GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn/Strobe Model um er art um er omina an e a Reverberant n nec olc oom Voltage (UL 1971) loft Per UL 464, dBA @ loft. 77 1 -12 1- 1 5, 75 1 1 -1 5, 75 1 1 12 2-0 1 15, 0, 75 1 0 1 -1 15, 75 1 -1 17-002 2 15, 0, 60,775, 110 2 100 -1 5 5, , 75, 11 100 - 15, 30, 60, 75, 11 100 5, 30, 60, 75, 11 Notes: •The GE3 Series is not listed for outdoor use. •Operating temperature: 32°to 120°F(0'to 49'C). •For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12 volt models are DC only. •Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014)„ Product Strobe Current Ratings GE3-24 Product Strobe-Current Ratings Candela I fc c c cd Cande;a I 15cdc c c c m m m m24VUG 55mAm mA 112MA I 136mA ax, I 163mA I 212mAm m LMax' m mA i IJ/mA 180mAm Product Horn Current Ratings - Pro-duct Horn Current Ratings Horn Mode Minimum Minimum egu a e Horn Mode -- Minimum Minimum egu ate dBA @ 10tt. dBA @ 10ft. 12VDC Max. dBA @ 1Oft. dBA @ 10tt. 24VDC Max. per UL464 per UL464 Operating @ (HIGH) (LOW) High Setting(mA) per UL464 per UL464 Operating @ (HIGH) (LOW) High Setting(mA) Temp3240OHz 29 7e-m-p-MOOHz emp ec anica 75 26 lemp 3 Mechanical emp 3 Chime emp 3 Chime onlinuous z ontinuous z ontinuous MechanicaTontinuous Mechanical 25 ontinuous Chime 13 77-tinuous Uhime 70* is [WhoopWhoop 56 'Operating the horn in this mode at this voltage will result in not meeling the minimum UL reverberant sound level required for public mode fire protection service. These set- tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode) Notes:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw,add the strobe current draw and the horn current draw. t The listed reverberant dBA are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA 4 loft.per UL 464 is 77-83 with a horn current draw of 34mA. RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16.33VDC for 24VDC units)(8-17VDC for 12VDC units) For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings.see installation manual. Mounting Super-Slide"' Switch Locations .;N J I I f T rn .e Cant t'J 1Pl FF __- or, rr rl a '1 T r'P GPI OFF �FF r...._. "FF fF Switch Position 6 HIGH dB OFF,LOW dB Switch Poeltlons t and 2 In the off position to select isolated horn and strobe power inputs. Die Cast Metal Mounting Plate: Mounts to single gang, double gang 4"square boxes or GSB box. ON (i Jj4 Checkmate" - Instant Voltage Verification _ ry; �,tl 12 3 4 5 6 4 S+ ° Candela Selection S+ I tug tj m Canita Bt vt*n slider ;wady :J ;re",:enter ana;•H grrt.hr.>&Simd I The access holes are provided in the back of the terminal E ai:(J er 1 IS61 '.y y°I t I` . 1 ]0 1 J rJ block to allow the voltage to be measured directly without -' h 75 removing the device. Typically this would be done at the �:r.,l •„t -r tr rra.lr xA r" 1. argil end of the line to confirm design criteria. Most measure- r.>T..ac�soie.xa vW6 ments will be taken using the S+ and S-locations h it .- Wa' although access is provided to other locations. NOTE: I i Care should be taken to not short the test probes. 1 + I+ Conventional GES3/GEC3 Series Wiring Diagrams UL Listed uL Listed Control Signal Control Panel g Signal panel Signal Signal S+ S+ S- H+ H- S+ S+ S- H+ H- S. S. S- H+ H- S+ S+ S. H+Supervised B 0 0 supervised Signal Circuit Signal Circuit \ \ } -70 \ ERE IS UNE ENO OF LINE RE9r3TOR RESISTOR Eno OF unE REsuroR , i I 4C y £ a., ,'X Y i t�y 4' r IX'S i Wiring Diagram GE3 Series with Gentex Synchronization Module F A.C.P. S.TOR £eC �xf ...................................... �f �M , .'.U5e• TO NFXT SIGNAL TO NOTIFICATION ALARM CIRCUIT wuwp ONLY ........................................... I TO NEAR SIGNAL TO NOTIFICATION ALARM CIRCUIT REMOVE JUMPER FOR INDEPENDENT AUDIBLE SIGNAL EMo a<uaE SYNCHRONIZED STROBE _ AfeatOP foR AND MORN OPERATION "^ CIRCUIT wx,$sa LEAVE JUMPERM PLACE SYNCHRONIZATION xa otaY TO ELIMINATE NEED FOR MODULE 00 ® HORN INPUT ON AVSM LEAVE JUMPER IN PLACE ON _ ANO OPERATE SIGNAL SLAVE UNITS UNLESS SEPARATE IN UNISON MODE 9 CONTROL OVER MORN CKT SYNCHRONIZATION IS REQUIRED. MODULE signet Slgnel S• S' S- H' /4 S- S. S- Il- H- VISIBLE SIGNAL CIRCUIT ErA of uRE RL45TOR E Or CU59 B nano any I i Ehon use ........................RE S:STpII foR ...1_�_..._____-__--_._ , I I CU3a A I , 'Mktg dAY - Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GE3 12 VDC Series, the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc.per UL 1971 and/or UL 464.The notification appliance shall also be listed with the California State Fire Marshal(CSFM)and the Bureau of Standards and Appeals (NYC). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12 or 24V as measured in an ane- choic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- ity to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models. The appliance shall be capable of testing supervision without disconnecting wires.Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton Important Noire G E 1V T E X These material.sum nave been prepared by Centex Corporation l advice an for ould nor be purposes such. are 551 0050-02 necessary summery,and are not purposed to serve as legal mplie end should ma be used as such. Gentex makes no repre3enlalion3 and warranties.express or imptiW,IhAI Ihesa ma18ha13 are Complete CO R P O R A T f O N and accurate.up-to-date.or m Complmnce with all relevant local state and federal laws,regulations and rules. The malenals do not address all legal—sidemllons as mere i3 inewlable un dr my regardnq inlerptetAhon of laws.regulahons and rules and the appiwation of Such IAwa regulations and rules to pad[' Fire Protection Products:www.gentex.com ular fact patterns. Each persod's activities Can differently affect the obbgal,ons that exist Undet appllcaoe was.regulations or rules. Therefore.these materials should be used only for Inlotmauonal purposes and 10985 Chicago Drive Box 310 or Zeeland, Michigan 49464 shouldnol beused as asubstituts lot Seeking professional legal advice. Games lmh not be responsiole for 616 392.7195 Ea 1.800.436.8391 •616.392.4219 Fax any action or leilurs 10 act In reliance upon the information contained in this malarial. I....vr. r...,i,I I •....Il,<• %rT.l „i,.n.•II"..—In th.• 1.11511.yl1.1I If I'-lit—t II (�I nti,n rn Rot YI-lid'nikr F BATTERY CALCULATIONS JOB: MASON COUNTY MAINTENANCE FACILITY DATE:12.7-07 OWNER: MASON COUNTY LOCATION :12913 US HWY 101 NORTH Batte Calculation Worksheet Number of 0-0-- SD500-PS Device devices Alarm Current Per Device Current 5820XL Fire Panel(Current draw Standb : 215mA from batte 1 Alarm: 385mA 385mA SD500-AIMa mA SD500-MIM 35 .55mA 1 . mA 19.25mA 19 .55mA 10.45mA 10.45mA SD500-ARM 127max Standb Alarm: 0.55mA mA mA SD505-AHS SD505-AIS mA mA � mA mA SD505-APS 15 .55mA 8.25mA 8.25mA StandbiL mA Aux Pwr Alarm: mA r s AD500-LED (4010ax) LED mA SLC Standby: Alarm: mA Aux Pwr Standby-, mA SD505-ADHR 027 max) Alarm: mA SLC Standby, mA Alarm: mA AD505-DTS 127 max Alarm: mA SD505-ADHR 127 max None,Included with detector current DSD505-LIA1 254 max SD505=61B 127 max Standby/Alarm mA mA mA ' 5860 Remote Fire Alarm 1 Standby, .20mA .20mA Annunciator Alarm: .25mA 25mA 5824 serial/Parallel Module 2 max Standby/Alarm mA mA mA 5495 Notification Power Expander 4 Standby/Alarm 75 mA 175 300mA 700mA 5865-4 LED Annumciator(with reset Standby" mA mA MEMEW and silence switches) Alarm: mA mA 5865-3 LED Annunciator (8 max) Standby: mA mA _- +';, -s Alarm: mA mA 5880 Generic LED Driver Module Standby: mA Alarm: mA mA Standby: mA mA k 5883 Relay wertace (32 max) Alarm. mA t " mA 22mA per relay) WORD PROCESSING/ALL FORMS/BLANK FORMS/BATTERY CALCS 5820XL 1 A Total System Current 554mA 1,124mA 7Stanfih, Standby, mA mA mA Standby: mA mA mA Stand-by. mA n1A mA . mA mA n1A B 77777 Auxiliary Devies Current STROBE ONLY 6 Alarm/Standb . 72mA HORN/STROBE 75 Cd 432mA 14 Alarm/Standb : 124mA 1736mA Alarm/Standb mA "' ITA Alarm/Standby mA :{,, ITA Notification Appliance Current 21 68mA D Tot al al Current ratings of all devices in system line A+line B+C 554mA 3 292mA E Total current reatin s converted to amperes line D x.001 .554A 3.30A F Number of standby hours 24 or 60 for NFPA 72,Chan ter 1,1-5 2.5 : 24H G Multiply lines E and F. Total stndb AH 13.30AH .; .. H Alarm soundin eriod in hours. for exam le,5 minutes=.0833 hours I Multiply lines E and H. 0833H Total alrm AH .28AH "Add lines G and I. Total ampere hours 13.58AH re wired r `gut WORD PROCESSING/ALL FORMS/BLANK FORMS/BATTERY CALCS 5820XL G DRAWINGS I w PROJECT MASON COUNTY PUBLIC WORKS MAINTENANCE FACILITY HELIX PROJECT#A05-081 DATE December 13, 2007 CONTRACTOR ROGNLIN'S INC PO BOX 307 ABERDEEN WA 98520 (360) 532-5220 PHONE (360) 52-5761 FAX OWNER MASON COUNTY PUBLIC WORKS PO BOX 1850 SHELTON WA 98584 (360) 427-9670 PHONE SUB-CONTRACTOR TAURUS INDUSTRIES INC. 1036 73RD AVE SE OLYMPIA WA 98501 (360) 754-8491 (360) 352-0368 FAX SUBMITTAL PACKAGE FIRE ALARM BLDG 3 � t MASON COUNTY PUBLIC WORKS MAINTENANCE FACILITY HELIX PROJECT #A05-081 TABLE OF CONTENTS BUILDING THREE (A) EXPANSION MODULE (B) SMOKE DETECTORS (C) PULL STATIONS (D) M.I.M.S (E) HORNSTROBES AND STROBES (F) BATTERY CALCULATIONS (G) DRAWINGS uuURTESY OF TAURUS INDUSTRIES INC. 12/13/2007 1036 73RD AVE SE (360)754-8491 phone OLYMPIA WA 98501 (360)352-0368 fax A EXPANSION MODULE INTELLIKNIGHT ACCESSORY Model 5895XL Intelligent Power Module The intelligent way to distribute power throughout your installation. With 6.0 amps of output power, six programmable Flexput TM 1/0 circuits, and two Form C relay contacts, the Model 5895XL Intelligent Power Q Module allows you to greatly enhance the capabilities of an IntelliKnight 2; system, distributing power where needed throughout a facility. 5895XL modules connect via the RS-485 system bus. Up to eight 5895XL modules can be used per IntelliKnight system. Each 5895XL has its own optically isolated RS-485 bus to which other modules, such as 5860 remote annunciators and 5824 printer interface modules, can be connected. You can also connect 5815XL SLC expansion modules, adding flexibility and wiring distance. Each 5895XL supports its own backup batteries and monitors the AC power. Description • Up to 6,000 feet wiring distance 5895XL adds 6.0 amps of power, from 5895XL(same distance as six Flexput 1/0 circuits, and two main FRCP) Form C relay circuits to an • Battery charging capacity 35 Ah IntelliKnight installation. The 5895XL is optically isolated • Large cabinet can house two 18 providing ground loop isolation and Ah batteries or RBB accessory transient protection. The 5895XL cabinet can house battery sizes e conditions the RS-485 system bus larger than 18 Ah allowing up to an additional 6,000 • Room in FACP cabinet to mount feet of wiring. two 5815XL SLC expanders Operation • Built-in synchronization for # . = s" The green LED on the 5895XL appliances from AMSECOS, board indicates communication with Gentex@, Faraday, System rho the IntelliKnight FRCP. Sensoro, and Wheelock® The Flexput circuits can be notification appliance circuits, Electrical Specifications continuous power, resettable Primary AC: power, door holder power or 120 VRMS @ 60 Hz, 2.5A initiation circuits that can support 240 VRMS @ 60 Hz, 1.4A both 2- and 4-wire smoke Total Accessory Load: detectors. All Flexput circuits and 6A @ 24 VDC relay outputs are individually Current: mappable from the IntelliKnight Standby: 40 mA 5820XL FACP. Alarm: 160 mA Model 5895XL Features 1/0 Circuit Power: • 6.OA output power 3A per circuit (6A total per system) Approvals • Flexput 1/0 circuits, 3A each, Mechanical Specifications NFPA 13, NFPA 15, NFPA 16, programmable as notification Flush or surface mount NFPA 70, NFPA 72 and circuits, auxiliary power circuits, Dimensions: NFPA 101 or initiation circuits 14-1/2"W x 24-3/4"H x 3-7/8"D UL 864 • Supports Class A configuration (36.8 W x 62.9 H x 9.8 D cm ) CSFM for SBUS & Flexput circuits Overall Dimensions: 16-1/8"W x 26-3/8"H x 4-1/8"D MEA 429-92-E, Vol. IX • Ground loop isolation (40.6 W x 67 H x 11.8 D cm) • 2 Form C programmable relays Color: Red FM approved rated at 2.5A at 24 VDC • Transient protection Environmental SILENT Operating Temperature: • SBUS repeater conditions the 32°F — 120°F (0°—490C KNIGHT RS-485 signal Humidity: 10% —93% L3 non-condensing by Honeywell ACCESSORY Model 5895XL Intelligent Power Module Engineering Specifications The contractor shall supply a power module compatible with the IntelliKnight Model 5820XL FACP. The power module must have 6.0 amps of output power, Flexput 1/0 circuits rated 3.0 amps each, and two Form C relay contacts rated at 2.5 amps at 24 VDC. The power module shall connect to the main FACP via an RS-485 system bus (SBUS). The power module shall contain an additional RS-485 bus that is completely compatible with all IntelliKnight add-on modules, including 5815XL SLC expanders, 5860 remote annunciators, 5824 serial/parallel printer interface modules. The power module RS-485 bus shall be optically isolated providing ground loop isolation and transient protection. The unit shall be an SBUS repeater that conditions the signal driving up to 6,000 feet of additional wiring. 5820XL FACP 5895XL � MAIN SBUS IN/OUT -- 23 22 21 20 19 18 17 16 33 32 31 30 23 22 21 20 19 18 17 16 + A B - + A B + A B + NACs,Auxilary A e . A SLC Power,etc. IJ- _ - _-- 5824 5860 Used in Used(n To Next 3 Class A Class A SBUS Device D configurations Up to 6,000 Feet,Non-shielded Configurations z D 5895XL Connection to FACP z m r- rn W y NACs,Auxilary Power,etc. NACs,Auxilary Power,etc. 5895XL-1 SBUS 5895XL-2 SBUS To Next 5895XL 5860 5860 5824 SLC SLC 5895XL Installation Example 13 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350212 Rev. C.02/06 by Honeywell subject to change without notice. For more information,contact Silent Knight 7550 Meridian Circle Suite 100,Maple Grove, Mn 55369-4927, Copyright©2006 Silent Knight Phone: (800)328-0103, Fax: (763)493-6475 IntelliKnight is a Registered Trademark of Silent Knight Flexput is a Trademark of Silent Knight B SMOKE DETECTORS INTELLIKNIGHT ACCESSORY Addressable ; ra Photoelectric Type '4 Smoke Detector ilL Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment.And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog /Addressable an electronic signal. Under normal ; Photoelectric Type conditions, the status LED blinks Smoke Detector approximately every 15 seconds, The SD505-APS is particularly indicating that the head is *4. No 1 suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. foam or other similar materials which tend to smolder and produce Features large visible particles. • Low profile, 2 inches, including SD505-APS Smoke Detector base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17-41 VDC compensation for contamination without mechanical switches and a simple detector calibration Current Consumption: • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the . Built-in fire test feature Alarm: .55 mA WindowsTM based downloading software). Simple detector Calibration Ambient Temperature:32°F to 120°F testing through the control panel (0°C to 49°C) Operation or remotely through a Mounting: 4"Square, 4" The SD505-APS units made up of WindowsTm based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal-resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable from the pulsing light source. In the Air Velocity: 0 300 FPM • UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505-6AB detector and light is reflected from (Sold Separately) (6" Base) the smoke particles to the receiving CSFM approved SD505-4AB element. • MEA approved (4" Base) • FM Approved SILENT KNIGHT by Honeywell ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector Ali Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be ULo listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter=5-15/16" Diameter=3-1s116" r� a p Height=2 inches, \• ' including base x,X" aALENT Kxu3rr Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) 10 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight FORM#350225 Rev C,.05/OS by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone: (800)328-0103. Fax: (763)493-6475. c PULL STATIONS INTELLIKNIGHT O. SD500-PS and SD500-PSDA Addressable Pull-Station IntelliKnight`s addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds.up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated Addressable Pull contacts. • Reflective label makes it easier Station to locate in low light The SD500-PS is a single action Operation addressable fire pull station, and The SD500-PS/PSDA single action the SD500--PSDA is a dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull F IRE interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset ALARM explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32`F to 120-F • UL Listed communicating with the loop. The (o°C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box -• ADA compliant the addressable module is used to Optional Red Surface Mount Box PS-SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) • Surface mount back box Specifications available Operating Voltage: 24VDC r SILENT Standby Current: .55mA • Terminals - accept up to 14 Alarm Current: .55mA KNIGHT gauge wire IWELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500 PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. R FA'.P •R \ is Wiring I 3. 2 LT -Z j O Mounting to Single Mounting to Optional i Gang Electrical Box Surface Mount Box SD500-PSDA i Imuff E4clncal Bm mosl;,� Installing SD500-LK Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350342, Rev.09/03 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright 0 2003 Silent Knight D MIMS • - NIS �. Model SD500-AIM Addressable Input Module And Model SD500-MIM im Miniature Input Module ;ems h Intellil(nigt's addressable cont � act monitor modules combine fast response with pin-point location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight's IntelliKnight fire control panel. The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. Model SD500-AIM and SD500-MIM Input Modules The addressable input modules expand the flexibility of the IntelliKnight system by allowing the use of contact type inputs. Typical _ applications include manual pull stations and water flow switches. _ 1 Features �� • Operates on Class A(Style 6 &Style 7)or Class B (Style 4)SLC Loop. — — — • Single contact monitor. • Up to 127 modules per SLC loop. SD500-AIM S0500•MIM • SD500-MIM mounts in a single gang Operation SpeCiIlWtI00S box. Each addressable input module is Operating Voltage. 24 VDC • SD500-AIM mounts in a programmed with a unique SLC 4"-square or double gang electrical loop address. The module Standby Current: 0.55 mA box, and has an attractive ivory supervises the wiring to the contact Alarm Current: 0.55 mA cover plate. with an End Of Line (EOL) resistor. perature: s2 F to 12o F • SD500-AIM/MIM are DIP switch Ambient Tem ° ° programmable. If a fault occurs in the wiring, the (o°c to 491c) Accepts up to 14 gauge wire. module alerts the FACP. Mounting: SD500-AIM • • Both modules UL 864 listed; comply double gang box or with NFPA 72 4"-square electrical • 2500 ft max. wiring distance from box input module to contact. SD500-MIM CSFM listed. single gang box • • MEA 429-92-E, Vol. 9 SILENT • FM approved 132,KNIGHT ACCESSORY Model SD500-AIM and SD500-MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate. Model SD500-AIM FRONT VIEW BACK VIEW SIDE VIEW i Q 0 O f`�n O 1 4-7l6" i1l4- 1' Model SD500-MIM 2-v2" SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350231, Rev. 11/01 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright 0 2001 Silent Knight E HORN STROBES AND STROBES GENTEX CORPORATION i I Commander3 Series Selectable GEC3/GES3 Candela Evacuation Signals 12 & 24 VDC Applications S E R I E S The Commander3 Series is a low profile strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable 4 candela options of 15, 30, 60, and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three in _ 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to changa in the field by using switches. I��IIIII� The GE3 Series has a minimal operation current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander3 Series is shipped with the standard 4" mounting plate which Product Listings incorporates the popular Super-Slide'feature that allows the installer to easily test for supervision. The product also features a locking mechanism which C UL us F M secures the product to the bracket without any screws showing. APPROVED ;—q, T1„c ryrt,ol a inn WonutY.n^—M L..no,.na n u The Commander3 also features the Checkmate'"- Instant Voltage Verification L UM Cy UNOERWRiTER1 LABORATORIES;NC feature which allows the installer to check the voltage drop draw and match it to BFP(City of Chicago) the blueprint. BS+A/MEA#285-91-E • CSFM 7135-0569:122(GEC3-24&GEH-24) The GE3 Series appliancE.s are UL 464 and UL 1971, listed for use with fire pro- 7125-0569:123(GES3-24) p 7125-0569:129(GES3-12) tective systems and are warranted for three years from date of purchase. 7135-0569:130(GEC3-12&GEH-12) Standard Features • FM Approved • UL 464& UL 1971 Listed • Nominal Voltage 12 & 24 VDC • CAN/ULC S526-M87 Listed • 24 VDC units have field selectable candela options of ULSZ7.S3406 Listed(GEC3-24, 15, 30, 60, 75, and 110 candela GEH24&GEH12) • 12 VDC units have field selectable candela options of Product Compliance 15, 30, 60, and 75 candela • NFPA 72 • GEH horn is available in 12 or 24 Volt • Americans with Disabilities Act(ADA) • Super-Slide"' Bracket - Ease of Supervision Testing • Checkmate'""- Instant Voltage Verification �;, • Unit Dimensions: 5" h'gh x 4.5" wide x 2.5" deep , AIN MEMBER L55E+elEO ni • Synchronize Strobe and/or Horn with Gentex Series ME AV Control Module (12 Vol-, product must use the AVSM • Switch for Continuous or Temporal 3 (not available on Module) whoop tone) ' • Prewire Entire System, Then Install Your Signals • Surface Mount with the GSB (Gentex Surface • Lower Installation and Operating Costs Mount Box) • Input Terminals 12 to 18 AWG • Silence Horn While Strobes Remain Flashing • Switch Selection for High or Low dBA • Wide Voltage Range 8-17.5 VDC (12 Volt Models) • Switch for Chime, Whoop, Mechanical and 2400Hz Tone 16-33 VDC or FWR (24 Volt Models) • Tamperproof Re-entrant Grill • Faceplate Available in Red or Off-White GEH 12 or 24 Volt Low Profile Evacuation Horn Model um er Part Number- omina ever Bran n nec oic oom Voltage 1Oft. Per UL 464, dBA @loft. GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe Model um er i1i rt Number omina an e a Voltage (UL 1971) Model designations: "W" =Wall Mount "R" = Red Faceplate "W" =Off-White Faceplate "P" = Plain (no lettering)Available 1 with all models. These units are non-returnable. "Agent" bezel also available. GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn/Strobe Model um er Part Number Nominal Candera- ever erant dBA @ In Anechoic Room Voltage (UL 1971) loft Per UL 464, dBA Q loft. -12 1 1 00 1 5, 11 100 Notes: •The GE3 Series is not listed for outdoor use. •Operating temperature:32°to 120°F(0*to 49'C). •For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR(Full Wave Rectified)) power, see installation manual. 12 volt models are DC only. •Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). Product Strobe CurrentRatings - Product Strobe CurrentRatings an ea c ccl I 60cd I 75cdCandela c c c c c m m m m m mA_l 88mA I 11ZmAm ax mA 21;eMA 1 331 MA 436mAmax, m mA IIJIMA I 180MAm Product Horn Current Ratings Product Horn Current Ratings Horn ModeMinimum Minimum Regulated Horn Mode nimum Minimum Regulated dBA @ 10ft. dBA rd 10ft. 12VDC Max. dBA® 1Oft. dBA®1Oft. 24VDC Max. per UL464 per UL464 Operating® per UL464 (HIGH) (LOW) High Setting(mA) P per UL464 Operating (HIGH) (LOW) High Setting(mA) amp 3 240OHz 76 29 lemp 3 240OHz 28 Temp 3 Mechanicalemp 3 Mecha-F—E37— amp 3 Uhime emp 3 Chime Onlinuous 240OHz ontnuous 240OHz tinuou on s ec anica ontinuous ec amca onbnuous i25 me ontinuous ime 15 jWhoop 55 oop 56 'Operating the horn in this mode at:his voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These set- tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). Notes:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw,add the strobe current draw and the horn current draw. r The listed reverberant dBA are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA 0 loft.per UL 464 is 77-83 with a horn current draw of 34mA. 2 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8.17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Mounting Super-Slide TMSwitch Locations tr-`•. — c oN ON OFF �N� '' EAe•hgN.0 r.nl! f ' :N F-rim F 1 FF J F thm..'nnp LIN ON 'FF t FF ON OFF ry _ I _ vfican OFF OFF OFF t~•••1 .� Svitch Position 6 . I a j��"" ON>HIGH de OFF>LOW dB _ ` f/-�• •` Swath po9ltlons t and 2 In the off position to select /7t isolated horn and strobe jv� power inputs. Die Cast Metal Mounting Plate:Mounts to single gang, l y double gang 4"square boxes or GSB box. I � :' M;"�—:= - � ON Checkmate" - Instant Voltage Verification 1 2 3 4 5 6 iS+ Candela Selection S¢ H+ l range-7 3s3dlcn ana s�4�3.vt:h•o desired [�JfILJrjy Yhr ee3 lt•.d. 4 The access holes are provided in the back of the terminal Ewi<•a ir!o block to allow the voltage to be measured directly without "'"""' ;,lily'n. 1 s•dtla GO set+acn: ;rt� 3eeln^, is removing the device.Typically this would be done at the ran•.;.•fr: 1 ra.1r.t d.:NI p..••• hol.,ar.i end of the line to confirm design criteria. Most measure- r•>T ea"3a.•Xn V.•h�ls c ��••� I�� �}�� ments will be taken using the S+and S-locations •�•°yr'"° p although access is provided to other locations. NOTE: I + Care should be taken to not short the test probes. Conventional GES3/GEC3 Series Wiring Diagrams UL Listed UL Listed Control Control Panel Signal Signal Panel Sa"°I Signal S+ S+ S- H+ H- S+ S+ S- H+ H- S+ S• S- H+ I+ S+ S. S. H+ H- Supervised B 0 B 0 Supervised ignal Circuit Signal Circuit S + \ + L \ END OF UN! END OF LINE RE3111TOR RESISTOR \\\ ENO Or UNE O- Rl3131ON I y�^�yn. •n� � k a V Wiring Diagram GE3 Series with Gentex Synchronization Module F A.C.P +[vsroa�w '.a55• TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT w,sv,G OHir ._. ._..._............................... I TO NEXT SIGNAL �]TO NOTIFICATION ALARM CIRCUIT REMOVE JUMPER FORINDEPENDENT SYNCHRONIZED STROBE AUDIBLE IGNAL' u �„ AND HORN OPERATION CIRCUIT '• ` CIRCUITSar LEAVE JUMPERIN PLACE SYNCHRONIZATION TO ELIMINATE NCEO FOR MODULE F-V RN INPUT ON AVSM E PER IN PUCE ON _© 8 AND OPERATE SIGNAL UNITS UNLESS SEPARATEIN UNISON MODETROL OVER NORN CRT SYNCHRONIZATION IS REQUIRED. MODULE Signal 5;gna S. S. S H- 14 S- S- S. H- M- C L E VISIBLE SIGNAL CIRCUIT ENOo,mE AC45TM[p clue]as e,l,eG WM1r I I I Enoo[l,.a _____ ________________ ..___.__._-.'_t................. _...._. _.__._._........... CWaA w,saro oAr , Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GE3 12 VDC Series, the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc.per UL 1971 and/or UL 464.The notification appliance shall also be listed with the California State Fire Marshal(CSFM)and the Bureau of Standards and Appeals (NYC). The notification appliance(combination audible/visible)shall produce a peak sound output of 100clBA or greater at 12 or 24V as measured in an ane- choic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- ity to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models. The appliance shall be capable of testing supervision without disconnecting wires.Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton Important Not": G E N T E X These materials nave been prepared by Genies Corporation t•Genlex'1 for nionsational purpose.only,are 551-0050-02 ntceasenly summary.and are not purported to serve as 10941 advice and should nor be used as Such. Genes makes no representations and warranties.express or implied,that Ihese mate-is are Complete and flauraN.up,lo-dale.or In compliance with all reltvonl Ieoal,slate and leftist lawe,regulations and CORPORATION runts The materials do not address all legal considerations as mere i$,n—sable umerla,nly regarding interpretation of law].regulations And rules and Ina application of such Is".regulalldnS and rule]to pads'- Fire Protection Products:www.gentex.com utar last paaerns Each person'S Whvllles can d,lferently al1W the obligal,OnS oral exist under applKAme laws,regulations or rules. Therefore.those materials Should be used only lot informational purposes and 10985 Chicago Drive Box 310•Zeeland, Michigan 49464 should nor be Wed as a Substitute I.,].tking Professional advice Genies wet not be responsible IN 616 392 7195 • 1.800.436.8391 •616.392.4219 Fax any..loa or/allure 10 act In reliance upon the,rHCrmahon conlamed,h INS malenal. 6• •,.,,..,,n r n Ihl'h pin-•Lh.pWn Id Ihp P•nqu(1 Ibld,l.Tl.., r[I"'tlia'rr•Lon. mb I,r.RP,N rd'.1U.•r F BATTERY CALCULATIONS JOB: MASON COUNTY MAINTENANCE FACILITY DATE:12-7-07 OWNER: MASON COUNTY LOCATION :12913 US HWY 101 NORTH Battery Calculation Worksheet Number of Stanbl Y Alarm Device devices Current Per Device Current Current For each de/ice use this"formula:,This column: X This column" ,Currenf ,fir riu'rober ofdevices- 5820XL Fire Panel (Current draw Standb 215mA 215mA from batte 1 Alarm 385mA 385mA Addressable SLG,Devices� SD500-AIM 4 mA mA SD500- 35 .55mA 19.25mA 19.25mA SD500-PS PS 19 .55mA 10.45mA 10.45mA SD505-AHS 127m-ARM SD50ax Standb V Alarm: 0.55mA mA mA SD505-AIS mA mA mA mA SD505-APS 15 .55mA 8.25mA 8.25mA Standby: mA Aux Pwr Alarm: mA AD500-LED (40Max) LED mA SLC Standby: Alarm: mA Aux Pwr Standby'. mA SD505-ADHR (127 max) Alarm: mA SLC Standby: mA Alarm: mA AD505-DTS 127 max Alarm: mA SD505-ADHR 127 max None,Included with detector current DSD505-LIN.1 254 max ` Standby/Alarm mA mA mA SD505=61B 127 max 71 'ories Modules a; � , 5860 Remote Fire Alarm 1 Standby. 20mA 2prnq Annunciator Alarm: .25mA 25mA 5824 serial/Parallel Module 2 max Standby/Alarm mA mA mA 5495 Notification Power Expander 4 Standb/Alarm 75 mA 175 300mA 700mA 5865-4 LED Annumciator(with reset Standb mA mA ` and silence switches) Alarm: mA mA 5865-3 LED Annunciator (8 max) Standby: mA mA Alarm: mA mA 5880 Generic LED Driver Module Standby: mA mA Alarm: mA x. : mA Standb : mA mA 5883 Relay Interface (32 max) Alarm. mA m A 22mA er rela WORD PROCESSING/ALL FORMS/BLANK FORMS/BATTERY CALCS 5820XL r. A Total System Current 554mA 1,124mA Alarm/Standb . mA mA mA Alarm/Standby: mA mA mA Alarm/Standby, mA mA mA Alarm/Standby: mA mA mA B Auxilia Devies Current STROBE ONLY 6 Alarm/Standby: 72mA 432mA HORN/STROBE 75 Cd 14 Alarm/Standby: 124mA " :0 1736mA Alarm/Standby: mA yam. mA Alarm/Standby: mA 's';5.; mA Notification Appliance Current 2,168mA D Total Current atin s of all devices ins stem line A+line B+C 554mA 3 292mA E Total current reatin s converted to amperes line D x.001 : .554A 3.30A F Number of standby hours 24 or 60 for NFPA 72,Chan ter 1,1-5 2.5 : 24H G Multiply lines E and F. Totlstndb 13.30AH H Alarm soundin eriod i h for exam le,5 minutes=.0833 hours ' .0833H I Multi I lines E and H. TAdd lines G and I. Total a 13.58AH ' , WORD PROCESSING/ALL FORMS/BLANK FORMS/BATTERY CALCS 5820XL f G DRAWINGS