Loading...
HomeMy WebLinkAboutBLD2013-00527 Garage to Living - BLD Permit / Conditions - 8/6/2013 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 i� RESIDENTIAL BUILDING PERMIT BLD2013-00527 OWNER: DAN WILSON CONTRACTOR: LICENSE: EXP: RECEIVED: 7/5/2013ISSUED: 8/6/2013 SITE ADDRESS: 172 W CLARK RD SHELTON EXPIRES: 2/6/2014 PARCEL NUMBER: 320312200012 LEGAL DESCRIPTION: TR 6 OF NW NW SEE SURVEY 9/26 PROJECT DESCRIPTION: DIRECTIONS TO SITE: COVERTING ATTACHED GARAGE TO FAMILY ROOM TAKE LAKE BLVD TO CLOQUALLUM LEFT ON CLARK RD 300 YARDS TO ADDRESS General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 1 Occ. Group: Lot Size: Deck: Type of Work: ALT Fire Dist.: 13 No. of Stories: 1 Occ. Load: 0 Building:438 Valuation: $ 28,951.00 Building Height: Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: SEPA?: Rear: Ft. Slope: Ft. Model: Width: Ft. Side 1: Ft. Shoreline Desig.: Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 1 Ventilation Fan 1 Plan Check Fee TW 7/5/2013 $280.57 S2201300000001 Lavatories 1 EH Plan Review TW 7/5/2013 $ 103.00 S220130000000i Showers 1 Building State Fee DLC 8/5/2013 $4.50 S2201300000001 Kitchen Sink 1 Building Permit Fee DLC 8/5/2013 $431.65 S220130000000i Water Heaters 1 Plumbing Permit Fee DLC 8/5/2013 $43.50 S220130000000i Plumbing Base Fee DLC 8/5/2013 $24.70 S2201300000001 Mechanical Permit Fee DLC 8/5/2013 $9.00 S2201300000001 Mechanical Base Fee DLC 8/5/2013 $28.50 S220130000000i Total $925.42 BLD2013-00527 Please refer to the following pages for conditions of this permit. Page 1 of 4 CASE NOTES FOR BLD2013-00527 CONDITIONS FOR BLD2013-00527 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-098 The)person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X Z) 2) Owner/Agent is r spgnsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X �j 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department pri_�r to any further inspections being performed or approvals granted. X �,� 4) Owner/Age pis responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X �✓ 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved dogprnetswill result in failure of required building inspections.( 6) All replacement windows shall be installed per manufacturer's specifications and be flashed per IRC section R703.8. All installations shall meet requirements for guards per R613 and safety glazing per R308.4. WSEC requires a U-factor of.30 or less in all heated spaces. Existing, non-conforming, egress window openings are not required to be enlarged, but it is highly recommended. Egress windows replaced in an existing opening shall be brought into compliance with current codes if a product is available for this application. Building plans/permit are required for windows in new, enlarged or relocated openings these installations must meet all current codes. Windows and doors shall be installed in accordance with the manufacturer's written installation instructions and shall be available during inspections. X V\ BLD2013-00527 Please refer to the following pages for conditions of this permit. Page 2 of 4 7) Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Mason County alternative method for change of use, Window (Max U-Factor):0.30, NO Skylight, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Ceiling Insulation R-60 and Slab Insulation R-0. In addition the following credit from Table 9-1 shall be completed: .50 credit, water heater EF .93 or better, and showerhead max 1.75 GPM or less and sinks 1.0 GPM or less X L) 8) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Reference WSEC W5.� X 9) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 10) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org X � 11) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within.25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 12) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or re do i must be reviewed and approved by Mason County prior to construction. X 'V BLD2013-00527 Please refer to the following pages for conditions of this permit. Page 3 of 4 13) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. Tile construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be rr d✓l Jor to requesting additional inspections. X 14) All property lines shall be clearly identified at the time of foundation inspection. X 15) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinan s a building regulations. X 16) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented ti n ff�om being taken. No more than one extension may be granted. X 17) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROADWAY. ,n X �W This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of a on ounty access to the above described property and structure for review and inspection. OWNER OR AGENT: DATE: BLD2013-00527 Please refer to the following pages for conditions of this permit. Page 4 of 4 FORM MUST BE COMPLETED IN INK MASON COUNTY PERMIT NO. 7 .3:- PLEASE PRESS HARD BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 7 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (350) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATIf N Owner 0(",Le l -!s 81 W c ,-5r , Company Name ( Mailing Address I ly e-ln-i-V.-PA Mailing Address City—ShaAA� StateS�Zip Code 9y'311 City State Zip Code Phone 25(--0 Laf,,-0-n` Other Ph.--)5(-b 'f90 -905( Phone Other Ph. Lien/Title Holder Lx= Contractor Reg. # Exp. E mail address WXT , ALLIOR(L % e—&- E Mail Address Drivers Lic.# U I f._So DOB to/a'- Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic X Connect to Water System XName of Neater System Well_ Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No Fire District I Legal Description .T tic e>L WO 14 L�L.% -& Q►r 1 Qr#e Rd Site Address (Please include street name, street number and city) I-? 3-- L0 l Directions to site t �1- �� d � <n-, GO �\ Will timber be cut and sold in parcel preparation?Yes CNZ> Is property within 200'of Saltwater - 90 Lake u n River/Creek Pond_ Wetland N c Seasonal Runoff��Stream N o Slopes or Bluffs 15% Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add_.,X Alt Repair Other PRIMARY RESIDENCE EASONAL Use of Building �— escribe Work Q a- No. of Bedrooms, o. of Bathrooms Square Footage= st Floor. 4 24Floor 3rd Floor Basement Deck — Covered Deck Other - Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection.This permit/application becomes null & void if work or authorized construction is not commenced thin 180 days r i co tructio ork is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFA PR CRESS tNSP NAC T I iTY OF THlS PERM(TAPPLICATION OF 180 DAYS WILL INVALIDATE THEAPPLiCATION. X ' Date: -7 1 /?, Owner;fOwners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVEP DENIED NOTES Building Department T9Z4;1� 9l0• Go _- gli� Planning Department Environmental Health Department Fire Marshal ,FEES Building Permit Fee / Site Inspection Plan Review Fee g20 EH Review Fee Plumbing & Base Fee fAA7o Planninq Review Fee Mechanical & Base fee f Other Wood/ Gas/ Pellet Stove Fee State Fee _ Violation Fee Pre-Paid at Submittal �05 Valuation $ oZ `l51. TOTAL FEES r MASON COUNTY PERMIT NO. PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar•P.O. Box 186, Shelton,WA 98584 Shelton (360)427-9670•Belb (360)275-4467•Elma (360)482-5269 On the we www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION/ Owner ncc4'tt,- I t 14 1,2v\Ct- Lx�t (5r�n Company Name Mailing Address 17 2- D-- Q=8 Mailing Address City I-)V, State W1 Zip Code `7'K55-4 City State Zip Code Phone?s(_-,O Other Ph.mac) q-90-90 5 j Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address `�" vv-\ E Mail Address Drivers Lic.# L_ i f_5c CY+7aCP6 DOB ja c,, Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic_�� Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No. �x Fire District 1 Legal Description i I" ]4Q &0 -L Pr`:vc4-o_. to P A i S I/aP' Site Address(Please i clude strept name street number and ci � ty) Directions to site I � A-k, [,(,A +r) CA OQU 1itM f.� j- a. C' c�v-K d rx` v v,4 Is property within 200' of Saltwater Lake N River/Creek Pond Wetland �—Seasonal Runoff �( a Stream o Slopes or Bluffs > 15% TYPE OF JOB - New Add_X Alt Repair Other Use of Building i—c,O,v\ to vi Location of Fixtures/Units- 1st Flooi. > 2nd Floor Basement Garage Ioset PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG—Natural Gas_Heat Pump_ Toilets I Type of Unit No.of Units Fees Bathroom Sink I Furnace Bath Tubs Heatpumps Showers I Spot Vent Fan Water Heater I Propane Tank Clothes Washer Gas Outlets Kithen Sinks I Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. f X Date: O`er Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group T e Constr. Planning Department Environmental Health Department FEES Plumbing& Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES 6' 7.5' 7.0 3.5x5 1t Y( N D4 n: � 3'x 4'Shower O O F m str rV G 4 5 _ 3 o O tz I� C N JN ?Q cs C' 0G �vL CG W w Ol G o m a � X m � = o ►3 c l7 2-V13- o U S'2-7 3�031- 2-2- 0 vU l z-- tj'xCc k{DtZ y 'X& D2 Ll'Al, -0K- 3'x 1.5' 3'x 1.5' 3'x 1.5' �S OZ Pow 6 - - 36" Step-up Xh. j&OD ID cn 21 M &0 b - R--© x M 5' i Exterior Exterior Wall Wall M X I X ROOD T J M �O i Slider5' 6'slider S' r'''il r+ 36"