HomeMy WebLinkAboutSWG - SWG Application / Design / As-Built - 6/12/1992 SEWAGE SYSTEM PERMIT APPLICATION No. Permit Expires
MASON COUNTY DEPARTMENT OF GENERAL SERVICES FOR DEPARTMENT
ENVIRONMENTAL HEALTH DATE I BASI IAMOUNT iRECEIPT
303 NORTH 4TH/P.O.BOX 186/SHELTON,WA 98584 C'rC 1 ��.�: p
PHONE(206)426-5561 01 V /O
AFRICANTSMNATUR[ SITE: pprove No
".�iCrS M ELGS 377- 8�'tG �PProved
AIwREA PIIGf . BY:
N(Jf£RTr owNER DE SYSTEM REQUIRED Nt/
$AME SWME
AlxwEss N1pNf IN tATION,4Approved ❑Not Approved
SEwA C sEW,kiE \ RY:
NCIgf N.v,1. SElDTIc, DEBK.IEROJO NES
Bcu Eeefn ,� DE H TO WATER TABLE
P-QfCEL4< as302 - 43- oo/ao _ _
- - SOIL TYPE: �
7r � 2 -.2 3-a
TYKOF .0/JG<n. FNM1vcV NO.Of LOT
BUILDING BEDROOMS SIZE LiK Fl_xir 25.5 Z
SINGLE RESIDENCE 21 PU&IC WATER
WATER SYSTEM SYSTEM NAME
COMMERCIAL ONLY
LIQUID WASTE G.P.D. tq,r.
DIRECTIONS TO SITE:
SEPTIC TANK (S) GAL. PUMP RED-
—
JP + C c I .,- "__ .. r<�i '- DISTRIBUTION TILE TOTAL FEET
i ot.yrkT FILTRATION AREA TOTAL SQUARE FEET
FINAL INSPECTION RE{ UI D EFORE BACKFILLING
—. 11�• E DEPrR a
BACKFILL
2"STRAW OR PAPER
B.0•,A�i_ RiRliOwi� A)N i. ✓EKL EO STONE.
SY FO[C cw/ RiR6n./5 To PEQ kFZJ O OV�ER TILE
PIPESIZE
di4 p+(r TE_ r/. -or , - E—STONE
SITE PLAN AND SPECIAL STIPULATIONS I UNDERTILE
(INDICATE DIRECTION OF DRAINAGE) CRQ 5ECr1 Of TRFNCN f
�i_ . is
CoN Src.vcTronl ' to /: s - c -/6 y�
• TR.f:rJL!+ ?.Err/: rZ r_urr! /8 Cr C-oo AiF:DruNi 5:,A6L-' C'CUAi W17t ii
MTrJTnEb'M1i CF
s REMOVE No 7cP .sO ;� Dvkr•JCr �•�
o LATE,e�acs To FDLe c,,J CGnJTOUK. CA' sC 6,0e
• CVRYiR lh1 (7.eAnJ AZI Tf QUrk$D . 9Y TH;6 -r,N6
• *WltVlJ.9e- TRRAFr ,VDT ACCo<UEO CN ANV A4e7- tF D,PAre/FitcOAKe'Aq.4+.CiMSrvE�-
Le4nmJ.
• OWr.1�/C. -r0 ,OCAnjr, 0ae S5 pljFrL. Erl/r�k ORAr�1FiEl0 ALeA A.vO MArA/TAv^/
E,eo Lu-r v
DIUMT" roZL GROun/p WATf4- DRArnI/IGE. 9WAy 'YxoAA 3EprT4 F/ECDs_
fro UN DA- 7W - GZ;r CF_ DWRIAAG-E To 6�- DI VERB-MD : ?wvV AcoM -SE"pM FiEC05.
• RELOMM1ErJDeO THA> .a A� GEerrF^FO ;Na Trlct�G. iNS�ct sYSreM y' DtAtfer wRrL c-,
J O
MASON COUNTY SEWAGE SYSTEM DESIGN
DEPARTMENT OF GENERAL SERVICES xP OCP Nlzx
WKN /B' SalloY �� •�DEPTH OF
ENVIRONMENTAL HEALTH SECTION Cdf/e� wnN peek F L Bq<KFIEt
P.O.BOX 186.303 NORTH bth STREET.SHELTON.WA98584 5/*+� d OpT/Deln� Ca:EK-
PHONE(206)C26.5561 d< T'STRAWORPAPER(54.
PROPERTY OWNER DATE SUBMITTED
(a- 8 E O STONE
ADDRESS DESIGNED BV OVERTILE
,ram,0. hex .J/3Z a p JoN E®PIPE SIZE
r3eLFA1/ WA 9B .ZV SOIL LOG— DATA
LEGAL DESCRIPTION B' /3p"'j MFD.SRA/O W.Ts' STONE
f4OEf. dZ7.302-43-00/00 B-.2AVtL5 UNDER THE
T�L SAME O W Ratrllcth'.
O F S LOAMY SgND w.rN lT/�� CROSS SECTION OF TRENCH`IY Lw r
w-AVF-
CALCULATIONS: GPD if ptller SHOW THE FOLLOWING ITEMS IN GRID BELOW:
No.Bedrooms I than reddenee A. Horizontal system plan and, if mound system is proposed or
Application Rate:gal./sRJt./dw A/Z slopes exceeding 15%provide cross section,
B. scale
Grainfield Sizing:Absorption Area L� Ft.z Total LengN (7B FL C. Benchmark A,rtubout elevation, tank outlet elevation, Ibpf
form of pipel, elevation at finish grace at center of drainfield.
Pump Specifications: High level alarm Elevation Difference FL D. Property lines,Wilding,trees,slopes in excess of 5%,drwevery.
GPM /-r/4 Discharge Volume E. All wells or.drinking water supplies within ISO It.,water lines.
Volume of sump 'A F. Drainage system detail (i.e.curtain drain).
Septic Tank Size and Manufacturer /1: 5/. G. Replacement area.
SEE 47rRi ,._ vo> [.�., ;rl?- _.
5,0
I.F s
/ L C
p rar>a foe. SrTrrvvc— fg0 N
Y a4
rn.K Y
g 4DATEb
DJE/za/ '_11ANl
s
� The undersigned agrees not to hold the Mason County Department of General Services, Environmental Health Section,
n responsible in the event that the system as proposed by - )o..le s
fails to operate as required by the Mason County Health Code.
K:ar) vim CRC C- -;1 -(j,( & _ 8-e
Slgnatumof Owner Dab SignaWn of Daaign Data
i
{ MASON COUNTY
I
GENERAL SE44ICES DEPARTMENT - 148 B
P.O.BOX 186•S0.T NORTH 4th STREET•SHELTON,WA 8458�
PHONE(NIB)4R 61
RECORD OF FINAL INSPECTION OF YOUR SEWAGE DISPOSAL SYSTEM
OWNER AA ADDRESS/9
THIS RECORD IS NOT A GUARANTEE OF PERFORMANCE. CITY ZIP Qp/� �l
A SEPTIC SYSTEM IS NOT A MUNICIPAL SEWER. HOWEVER /07 a
WITH PROPER MAINTENANCE AND CAREFUL USE OF LEGAL DES ION
WATER IT CAN GIVE MANY YEARS OF TROUBLE FREE SER- 9309^ Y- - &0/m'0
[ •/,P S'F
VICE. MANY PROBLEMS WITH SEPTIC TANKS ARE CAUSED SOIL /j� - a 3 f T
BY FLUSHING EXCESSIVE AMOUNTS OF PAPER, CLOTH COMMENTS C:�/
AND PLASTIC MATERIALS DOWN THE DRAIN, OR BY SITE FIELD n
LARGE AMOUNTS OF WATER FROM LEAKY FAUCETS OR NO. SIZE o2 D X G [/
FAULTY FIXTURES. DEPTH TO MONTH
THE SEPTIC TANK ITSELF SHOULD BE CLEANED EVERY WATER TABLE OF YEAR
TWO OR THREE YEARS DEPENDING ON THE HABITS Of THE INSTALLER
FAMILY, THE NUMBER OF FIXTURES IN THE HOUSE, AND Ti' N
THE AMOUNT THAT A GARBAGE DISPOSAL IS USED. CLEAN- SIZE
ING AT THE RIGHT TIME WILL AVOID THE RISK OF INJUR- SEPTIC TANK (S) 11.5
ING OR DESTROYING THE DRAINFIELD DUE TO SOLIDS DRAINFIELD v G/, ' FEET
CARRYING OVER INTO THE DRAINFIELD. CALL THE LENGTH �I !Y
MASON COUNTY HEALTH DEPARTMENT FOR A LIST OF TRENCH AREA �a a SQ. FT.
LICENSED SEPTIC TANK CLEANERS IN YOUR AREA. THE O
CLEANER CAN SERVE YOU BEST IF YOU SHOW HIM THIS TILE ElCORRUGATED RIGID O CEMENT
DEPTH
RECORD WHEN HE COMES. // DEPTH -7
HEAVY TRUCKS OR EQUIPMENT SHOULD NEVER BE CTOTL
U.YDS. �,� (O BPIPE DEPTH WL
DRIVEN OVER THE TANK OR DRAINFIELD. CONSULT THIS SPACE RESERVED FOR
RECORD IN CASE OF ANY BUILDINGS, DRIVEWAYS, REPLACEMENT DISTRIBUTION FIELD: pc G X LO SQ. FT.
SWIMMING POOLS, OR EXTENSIVE GRADING OR FILLING NORTH
O
ARE LATER CONTEMPLATED. 2
SHRUBS OR TREES SHOULD NOT BE PLANTED CLOSE TO I K
THE SEPTIC TANK AS THEY WOULD INTERFERE WITH
CLEANING OF THE TANK. THEY CAN BE PLANTED IN THE Q
DRAINFIELD AREA PROVIDING WILLOWS ARE NOT USED. 1j
THE YARD GRADE IN THE DISPOSAL AREA SHOULD BE al
SUCH THAT SURFACE WATER IS NOT POCKETED ON THE
DRAINFIELD. ANY SETTLING OF THE GROUND OVER THE �
TRENCHES SHOULD BE FILLED IN WITH SOIL. DO NOT EX-
CESSIVELY WATER THE LAWN IN THE DRAINFIELD AREA.
WATER EVAPORATION FROM THE DRAINFIELD IS ABOUT
EQUAL TO ONE HALF INCH OF RAIN PER DAY.
FOOTING DRAINAGE, DOWNSPOUTS AND WATER 1
SOFTENER RECHARGE WATER SHOULD NOT BE CON- I�
NECTED TO THE SEPTIC SYSTEM OR DISCHARGED INTO THE ,r
DRAINFIELD AREA. 5 p'
THE TYPES OF BACTERIA NEEDED IN A SEPTIC TANK ARE 1 3 '
ALWAYS FOUND IN SEWAGE. THERE IS NO NEED TO ADD D a11•
YEAST OR OTHER STARTERS TO A SYSTEM. THE USE OF RE- (D
JUVENATORS OR CHEMICALS TO CLEAN A SEPTIC TANK
HAVE NOT BEEN PROVEN TO BE BENEFICIAL AND MAY BE
HARMFUL BY FLUSHING SOLIDS OUT OF THE TANK OR BY
CHANGING THE CHARACTERISTICS OF THE SOIL THE
NORMAL USE OF BOWL CLEANERS OR CLEANING COM-
POUNDS WILL NOT KILL THE BACTERIAL ACTION OR SLOW SOUTH y
DOWN THE OPERATION OF THE SEPTIC TANK. /_�� p, � ' - L
THIS IS AN IMPORTANT DOCUMENT DATE ;�/,,aP6t�`Y�AT-ORE '(INSTALLER
KEEP IT WITH DEED OR OTHER
ESSENTIAL PAPERS. DATF GNAT /JF INSPECTOR