Request for Building Administrative Variance for
Side Yard Reduction (Urban Growth Areas only)
Please fill out the following form for a request in reduction of the standard side yard setback
required for your zoning. The maximum allowed reduction will be based off of building and fire
code regulations; critical areas(if present) will also be considered. Setbacks are measured from the
furthest projection of the structure, including roof eaves and gutters.
Applicant/Owners: Rob May
Mailing Address: 271 E. Okonek Rd.
City: Grapeview State: WA Zip: 98546
Telephone: 206-999-7764
Email: 1414rbmay@gmail.com
If this reduction is tied to a building permit, please give permit case number.
BLD 2024-01147-
Parcel Number(s): 12108-24-00060 Zoning
Site Address: Same
Requested setback variance(side yard only):
4 ft. ❑✓ North
ft. ❑ West
ft. ❑ East
ft• ❑ South
Side Setbacks-From the side property line. Minimum side yard setback allowed is based off of Table
R 302.1(1)from the International Residential Code (IRC). See next page for table.
An illustrated site plan is required.
Your site plan must show the following: north arrow, abutting street or easements, and set backs to all
property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and
driveway. Show all proposed new development.
s
Table R 302.1(1)
Exterior Walls
Exterior Wall Element Minimum Fire Resistence Rating Minimum Fire Separation Distance
Fire-resistance rated 1-hour tested in accordance with ASTM E 119 or <5 feet
UL 293 with exposure from both sides
Walls not fire-resistance rated 0 hours >5
not allowed N/A <2 feet
Fire-resistance rated One hour on the underside°^ >_2 feet to<5 feet
not fire-resistance rated 0 hours >5 feet
Projections
not allowed N/A <3 feet
25%maximum of wall area 0 hours 3 feet
Openings in Walls unlimited 0 hours S feet
All Comply with Section R302.4 <3 feet
Penetrations None required 3 feet
For SI:1 foot=304.8 mm
N/A=not applicable
1.Roof eave fire-resistance rating shall be Permitted to be reduced to 0 hours on the underside of the eave if fireblocking is provided from the wall ton plate to
the underside of the roof sheathing.
2.Roof eave fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave Provided that gable vent openings are not installed.
SIDE YARD REDUCTION REQUESTS: Explain how the circumstances preclude a reasonable
development proposal from meeting the setback standard for the residential zone in your Urban
Growth Area(Shelton, Allyn, or Belfair).
We would like to put the heat pump unit on the north wall (exterior), Elevated
about 8-10 ft. The unit is approximately 12" deep with a 4" set off the wall for a total
of 16"+-, set off the wall.
This would encroach slightly into the 5' set back as we are 5'-6" from the property
line. We are hoping that since it is elevated (so as not to impede anyone passing by
and that it is quite small in size that this would be OK?
Owner/Agent (please indicate) nMML2-26-25
ure Date
O acialll Onl
Planning Approval: Date
Building Approval: Date
Denied by:
Reason for denial:
w oavp a v voa Iv QQ� v4 avo�
�`��♦p� O OO4 OOC? OHO OOO OOO OO�� 05�0
O `
� 4 D D O D O O D 4 D O �-O(�+ Qo0 400 4p4 4p �S9 , • po0 4 NEw-� �v.r►.p
° a s ,, SEC 8
00-1
ip o0 PO PO OO ':;� - •S �2
10
Ik
°O Q4 4O 04 O aQ ° QO Q r •}�' %iti.�.•�,• �• ti~.;... :r ?� I DFCCh/
PARCEL NO. O
1 2 1 08-24-00060 .�`�' ' -'. GARAGE f sroe.Z 12¢- 6.2'
JE�' ' ;.,,' SHED
271
E OKO.NEK RD ` 8 48'
HOUSE07
?��' F .•f DECK .�;...�•, .4 :.
44
F�J ado,
10
CoNc7rcT(
pu�KE�E��
wAu
r.
FLOOR
R1Lrt�P
L I�
I
1�
I
3 ON GRADE
O I NORTH ELEVATION
SCALE:3/B'•1'4r