Loading...
HomeMy WebLinkAboutBAV2025-00003 - BLD Application - 3/4/2025 MASON COUNTY Mason County Permit Center Use: COMMUNITY SERVICES BAV 202_5 Building,Planning,Environmental Health,Community Health 615 W.Alder St.—Bldg.8,Shelton,Wa 98584 Date Rcv4- -2 ? Phone:(360)427-9670 ext.352♦Fax:(360)427-7798 Fee: $ Q 66 , Request for Building Administrative Variance for Side Yard Reduction (Urban Growth Areas only) Please fill out the following form for a request in reduction of the standard side yard setback required for your zoning. The maximum allowed reduction will be based off of building and fire code regulations; critical areas(if present) will also be considered. Setbacks are measured from the furthest projection of the structure, including roof eaves and gutters. Applicant/Owners: Rob May Mailing Address: 271 E. Okonek Rd. City: Grapeview State: WA Zip: 98546 Telephone: 206-999-7764 Email: 1414rbmay@gmail.com If this reduction is tied to a building permit, please give permit case number. BLD 2024-01147- Parcel Number(s): 12108-24-00060 Zoning Site Address: Same Requested setback variance(side yard only): 4 ft. ❑✓ North ft. ❑ West ft. ❑ East ft• ❑ South Side Setbacks-From the side property line. Minimum side yard setback allowed is based off of Table R 302.1(1)from the International Residential Code (IRC). See next page for table. An illustrated site plan is required. Your site plan must show the following: north arrow, abutting street or easements, and set backs to all property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and driveway. Show all proposed new development. s Table R 302.1(1) Exterior Walls Exterior Wall Element Minimum Fire Resistence Rating Minimum Fire Separation Distance Fire-resistance rated 1-hour tested in accordance with ASTM E 119 or <5 feet UL 293 with exposure from both sides Walls not fire-resistance rated 0 hours >5 not allowed N/A <2 feet Fire-resistance rated One hour on the underside°^ >_2 feet to<5 feet not fire-resistance rated 0 hours >5 feet Projections not allowed N/A <3 feet 25%maximum of wall area 0 hours 3 feet Openings in Walls unlimited 0 hours S feet All Comply with Section R302.4 <3 feet Penetrations None required 3 feet For SI:1 foot=304.8 mm N/A=not applicable 1.Roof eave fire-resistance rating shall be Permitted to be reduced to 0 hours on the underside of the eave if fireblocking is provided from the wall ton plate to the underside of the roof sheathing. 2.Roof eave fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave Provided that gable vent openings are not installed. SIDE YARD REDUCTION REQUESTS: Explain how the circumstances preclude a reasonable development proposal from meeting the setback standard for the residential zone in your Urban Growth Area(Shelton, Allyn, or Belfair). We would like to put the heat pump unit on the north wall (exterior), Elevated about 8-10 ft. The unit is approximately 12" deep with a 4" set off the wall for a total of 16"+-, set off the wall. This would encroach slightly into the 5' set back as we are 5'-6" from the property line. We are hoping that since it is elevated (so as not to impede anyone passing by and that it is quite small in size that this would be OK? Owner/Agent (please indicate) nMML2-26-25 ure Date O acialll Onl Planning Approval: Date Building Approval: Date Denied by: Reason for denial: w oavp a v voa Iv QQ� v4 avo� �`��♦p� O OO4 OOC? OHO OOO OOO OO�� 05�0 O ` � 4 D D O D O O D 4 D O �-O(�+ Qo0 400 4p4 4p �S9 , • po0 4 NEw-� �v.r►.p ° a s ,, SEC 8 00-1 ip o0 PO PO OO ':;� - •S �2 10 Ik °O Q4 4O 04 O aQ ° QO Q r •}�' %iti.�.•�,• �• ti~.;... :r ?� I DFCCh/ PARCEL NO. O 1 2 1 08-24-00060 .�`�' ' -'. GARAGE f sroe.Z 12¢- 6.2' JE�' ' ;.,,' SHED 271 E OKO.NEK RD ` 8 48' HOUSE07 ?��' F .•f DECK .�;...�•, .4 :. 44 F�J ado, 10 CoNc7rcT( pu�KE�E�� wAu r. FLOOR R1Lrt�P L I� I 1� I 3 ON GRADE O I NORTH ELEVATION SCALE:3/B'•1'4r