HomeMy WebLinkAboutBLD2024-00551 Garage, Living Space - BLD Inspections - 3/12/2025 t � r MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584 � -E COMMUNITY SERVICES SHELTON:360.427-9670,EXT 352 i BELFAIR:360-275-4467,EXT 352 Building,Plannuig,Environmental Health,Community Health ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http:itwww.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2024-00551 Date Issued 06/21/2024 Issued By /1-),)e)R S Project GARAGE W/BONUS SPACE Site Address 2510 E State Route 302 Applicant REYNOLDS JAMES G&JESSICA Contractor RED DOOR DESIGN&BUILD Contractor Phone 360.927.1578 Prima Code 2018 IBC,IRC,IFC,IEC,IMC,& T Primary UPC Type Permit Type GARAGE/STORAGE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.** PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor (( ` �•` Other rtYC.�JM�Y% Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other rA)L ^ ((-25,.?"l 060 fdG aid' INSPECTION RESULTS Pagel - fmMASON COUNTY Department of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton,WA 98584 Permit Assistance tenter;Building,Planning (360)427-9670 ext.352 Application# BLD2024-00551 Application Type GARAGE/STORAGE Owner REYNOLDS JAMES G & JESSICA Parcel# 122162100030 Site Address 2510 E State Route 302 Belfair, WA 98528 Inspector Inspection Type Date Status Comments 11-25-24 DED 1)structural plans do not match with truss engineering. Contact Engineer of record and Provide documentation from engineer with plans for moving forward. 2)deck ledger lags not installed per plans. ledger lag screws are screwed into bottom cord of truss and several screws are only screwed to sheeting. Provide engineers fix Dave Dobson FRAMING INSPECTION 11/25/2024 FAIL for this. *�keveral anchor bolts are missing nuts 4)hurricane clip above garage door missing nails. 5) Note on plans calls for attic trusses to be sheathed. Please provide clarification from engineer. NOT A COMPLETE INSPECTION INSPECTION RESULTS Page MASON COUNTY Department of Community Development COMMUNITY DEVELOPMENT 615 W Alder St, Shelton,WA 98584 Permit Assistance Certt�t,Budding,Planning (360) 427-9670 ext. 352 Application # BLD2024-00551 Application Type GARAGE/STORAGE Owner REYNOLDS JAMES G & JESSICA Parcel# 122162100030 Site Address 2510 E State Route 302 Belfair, WA 98528 Inspector Inspection Type Date Status Comments 12-27-24 DED 1)refer to previous correction report and provide necessary engineering documents at the time of reinspection. 11-25-24 DED 1)structural plans do not match with truss engineering. Contact Engineer of record and Provide documentation from engineer with plans for moving forward. Dave Dobson FRAMING INSPECTION 12/27/2024 FAIL 2)deck ledger lags not installed per plans. ledger lag screws are screwed into bottom cord of truss and several screws are only screwed to sheeting. Provide engineers fix for this. 3)several anchor bolts are missing nuts 4) hurricane clip above garage door missing nails. 5) Note on plans calls for attic trusses to be sheathed. Please provide clarification from engineer. NOT A COMPLETE INSPECTION Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov BLD2024-00551 GARAGE/ STORAGE PROJECT DESCRIPTION: GARAGE W/BONUS SPACE ISSUED: 06/21/2024 SITE ADDRESS: 2510 E STATE ROUTE 302 BELFAIR EXPIRES: 12/18/2024 PARCEL: 122162100030 APPLICANT: REYNOLDS JAMES G&JESSICA OWNER: REYNOLDS JAMES G&JESSICA 2510 E STATE ROUTE 302 2510 E STATE ROUTE 302 BELFAIR,WA 98528 BELFAIR,WA 98528 425-8304440 CONTRACTOR: RED DOOR DESIGN&BUILD 1706 FRONT ST#443 LYNDEN,WA 98264 360.927.1578 GENERAL CONTRACTOR'S LICENSE: RED DOOR DESIGN&BUILD License: REDDODD821 MJ 1706 FRONT ST#443 Expires: 07/11/2024 LYNDEN,WA 98264 360.927.1578 VALUATIONS: FEES: Paid Due Uncovered Deck 240.00 $3,600.00 Plan Check Fee $870.69 $0.00 U VB Utility, miscellaneous 2061.00 $137,015.28 Building Permit Fee $1,339.52 $0.00 Change in Tenant- Minor EH $135.00 $0.00 Plan Review State Fee-Residential $6.50 $0.00 Technology Surcharge $44.20 $0.00 Planning Review Fee $240.00 $0.00 Total: $140,615.28 Totals : $2,635.91 $0.00 REQUIRED INSPECTIONS Setback Inspection Underfloor Inspection Footing Inspection Framing Inspection Foundation Wall-Pre-Pour Inspection BLD-Final Inspection Printed by:Anna Schaffran on:06/21/2024 12:09 PM Page 1 of 5 AIL AIK_ Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov GARAGE/ STORAGE BLD2024-00551 CONDITIONS * OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. * The use, handling and storage of hazardous materials or flammable and combustible liquids is not allowed without the approval of the Mason County Fire Marshal. * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being taken. * All changes to "approved"building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. * All property lines shall be clearly identified at the time of foundation inspection. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * Concrete used for basement walls,foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). Printed by:Anna Schaffran on:06/21/2024 12:09 PM Page 2 of 5 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov GARAGE/ STORAGE BLD2024-00551 All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. For more information contact Public Works, at(360)427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 mph with 110 mph gust factor. Printed by:Anna Schaffran on:06/21/2024 12:09 PM Page 3 of 5 Mason County Ilk Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov GARAGE/ STORAGE BLD2024-00551 * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance contact the Mason County Public Works Department prior to construction at Ext 450 * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Code 14.28 and 14.17. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the intemational codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The foundation/footing must be placed on undisturbed,firm-native soil. Proper frost depth, minimum 12 inches, shall be observed below grade in undisturbed soils. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and approved by the Washington State Department of Transportation. For more information contact Washington State Department of Transportation, at(206)357-2620, ext. 630. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * Not approved as an ADU * This structure is approved as unheated space. To be considered unheated space the area may be provided with a heating system that does not exceed maxium output of 1 watt per square foot., or 3.4 Btu/h per square foot. A permit and approval is required prior to installation of any heating system. When a heating system exceeds 1 watt per sq.ft(or 3.4 btu/h per sq. ft)the heated space shall be insulated in accordance with the energy code in effect at the time of permit application. * This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved. * Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * LETTER OF APPROVAL OF TRUSS PACKAGE, FROM ENGINEER OF RECORD, TO BE ONSITE AT FRAMING INSPECTION Printed by:Anna Schaffran on:06/21/2024 12:09 PM Page 4 of 5 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov GARAGE/ STORAGE BLD2024-00551 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: /�nno, S . Contractor or Authorized Agent: _ Date: v ( 1 Printed by:Anna Schaffran on:06/21/2024 12:09 PM Page 5 of 5 Hodge 1114/2°25 Report# 240129B engineeringinc. RE: 2510 E State Route 302 Belfair, WA Renolds Garage Items 2 and 5 of Correction Notice 5. My engineering specifies to sheath the bottom chords of the attic truss to provide lateral stability. Per the builder 5/8" drywall has been screwed to the trusses for the ceiling. The 5/8" drywall is adequate for added lateral stability requested by engineering. 5/8" drywall can contribute to the lateral stability of trusses when installed on the bottom chord. The drywall acts as a diaphragm, providing some lateral stability to the trusses by distributing loads and resisting lateral forces. Being thicker, 5/8" drywall is more robust than 1/2", enhancing its ability to stabilize the bottom chord compared to thinner drywall. K' 1r-------- -- -- - _-__1 rr- 1l14 25 cz- 7886 �i S iY i Repo ISTER�' �4. �nnEp arnc e.Ae t= I F IONAL �G Y ears+oaos m Y Y a , E+rEaoie urvae rqe I t u ,rAWWrts John Hod/fie RE If EY i i , il I .7 II � a i .warwaiYs I I tdro�or+R7 I —77 Y ¢ Sago I I I r PWWWR 1t L_4-1.. .------ ----C—f—_---w---C-------- -- ---�—,—J r= Hodge Engineering, Inc. '' Rosedale St NSW.Suite 200,Gig Harbor,WA 8 x„ 3733 �, � 335 (253)857-7055 Hodge 1/40/295Report # 24Q129B engineeringinc. RE: 2510 E State Route 302 Belfair, WA Renolds Garage Items 2 and 5 of Correction Notice As a repair the builder may add 2x6 blocking cut to fit between the truss vertical webs as shown below. The deck screws that missed structure are to be reset into the 2x6 blocking. Cover the 2x6 blocking and truss webs with an additional 2x6 nailed to the blocking and truss. Note that the truss is engineered as fully supported by the wall below. The 2x6 added will not adversely affect the truss members tension or compression capacities. 212 34 33 T2 F c F1 STB ST9 ST5 ST5 STs ST4 f ST8 W3 S 8 ST6 ST4 St3 t�'�'Q W2 Ti ST2 W1 ST6 V�2 < Wt ST2 i 82 N :.1s'I .� �. HW1 yyayA,yy...........:.. ,..,,�...................,,............�y...ayb..,..,..._.,,_........_saa�.aysrere:.umeueutm................,.,._........,.aeur:aearuwevaeeuz� Area of 2x6 backing S 5 S 17 ct 8 S 8 W% i T � F 2 � 6 2 1LO - Closeup of 2x6 backing area Hedge Engineering, Inc. .John P.. Hodge K K 3733 Rosedale St MN,Sttite 200,Gib; Hartxtr, WA 95335 (253)557-7055 1/14/2025 / Hodge Report # 240129B 9 9 en ineerin inc. RE: 2510 E State Route 302 Belfair, WA Renolds Garage Items 2 and 5 of Correction Notice I or,:,OTTE i 2 Wd�---- --------- i (J •(Dwxk-&:s o u ATE TO - --- 314 74610 MM !d•W OZ. ix OR rM FLOOR.05- S 3 V•4'OcMO. "ATWW.TO SW 4!Ott I SEE 54EAR AALL SC4EDuLE I ■ (3)6OW5224COM SCREW � s 5'dGGER£D 0 w'OG J-: I OR STRUCTURAL Itm a� � ©aEa,,0 516 PER PLAN 3:4,T#G FLOORRNG S 1 F-45WWG BY DE6&&R I 5EU ------ I ROR ADO TOUR N.Y 11" �y�•. DECK`EC*ER Cam'E�' a i ,>pTTy N LEtu I i fC] i `Q P I.� ;n • 4.. _ -a Hodge Engineering, Inc. John F. Ilodge P. F. h 3733 Rosedale St NW,Suite eon,Gig Harbor,WA 95335 ..i/ (253)857-70.55 1/14/2025 Hodge Report 4 240129B engineering inc. 9 9 RE: 2510 E State Route 302 Belfair, WA Renolds Garage Items 2 and 5 of Correction Notice To Whom It May Concern: I have provided the lateral and gravity load engineering for the Renolds Garage, located at 2510 E State Route 302 Belfair. Engineering Requested: At the builder's request I have reviewed items 2 and 5 of the 11/25/24 correction notice below. Item 1 was addressed in my engineering report 240129A dated 12/12/24 fo the manufactured trusses from Louws Truss dated 6/26/24. The correction notice below and pictures were provided to Hodge Engineering on 1/13/25. 4r r Mstructural plans • . not match with truss engineering. 'iContact Engineer of record and Provide documentation 'from engineer with plans for moving forward- !12)deck ledger lags not installed per plans. ledger lag 1'zicrews are screwed into bottom cord of truss and several screws are only screwed to sheeting. Provide iengineers fix for anchorbolts are missing nuts 4) hurricane clip above garage door missing nails. 5) Note on plans calls for attic trusses to be sheathed. Piease •- clarification from • 2. Deck Ledger Screw As-Built is Not Acceptable: The deck ledger detail 2202 specifies the deck ledger to be screwed to a rim board. To raise the deck to meet the attic truss opening the builder has raised the deck ledger_ Hedge Engineering, Inc. John F. Ilodge N. F,. 373:3 Rosedale. St NW,Suite 200,Gig Harbor,WA 98335 (25:3)857-7055 12/12/2024 fPHodge Report # 240129A g gen ineerininc. RE: 2510 E State Route 302 Belfair, WA Renolds Garage Manufactured Truss Review To Whom It May Concern: I have provided the lateral and gravity load engineering for the Renolds Garage, located at 2510 E State Route 302 Belfair. Manufactured Trusses: At the builder's request I have reviewed the manufactured trusses from Louws Truss dated 6/26/24. The truss layout is attached, and an image clip is below. '-ilAJ } j t B 12-v w xaaao oaom CIS a1TXMld7 �•tlr.Ca 1L16:A:!f:! ! 75A VFi .- .�s a ae 1 Hodge Engineering, Inc. John E.Hodge P.E. 3733 Rosedale St NW,Suite Zoo,Gig Harbor,WA 98335 (253)857-7055 Hod e 12/12/2024 Report # 240129A engineering inc. RE: 2510 E State Route 302 Belfair, WA Renolds Garage Manufactured Truss Review If R )28 E _— : •� »-SD53 �GT4-SD53 .E i li i f nL DM �i 118 � I• � n The trusses follow the design and engineering. The manufactured trusses do not adversely affect my engineering provided detail 4/D1 holdowns shown above were installed. 12/3/2024 `y U Report#240129A j 3 John Hodge P. =- Hodge Engineering, Inc. John E.Hodge P.E. 3733 Rosedale St NW,Suite Zoo,Gig Harbor,WA 95335 - (253)857-7055