Loading...
HomeMy WebLinkAboutBLD2001-00952 Final Horse Arena - BLD Permit / Conditions - 2/11/2002 Insection Line 262 27- MASON COUNTY DEPT. OF COMMUNITY Pho ne: (360)427-9670,4ext7352 DEVELOPMENT Mason County Bldg. 3 426 W. Cedar P.O. Box 186 � Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2001-00952 OWNER: CHUCK ERNS T 360-372-2570 CONTRACTOR: SOUND BUILDING SYSTEM360-2997-7317 RECEIVED: 9/12/2001 SITE ADDRESS: 1711 NE TOONERVILLE DR BELFAIR ISSUED: 10/31/2001 PARCEL NUMBER: 223117500160 EXPIRES: 4/30/2002 LEGAL DESCRIPTION: TR 16 OF SURVEY VOL 3 PG 98 PCL 2 OF BLA#97-65#655175 PROJECT DESCRIPTION: DIRECTIONS TO SITE: HORSE ARENA G WEST ON BEAR CREEK DEWATTO RD, FIRST LEFT AFTER ELFENDAHL PASS RD, IS TOONERVILLE DR, SITE IS LAST DRIVE ON LEFT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: V-N Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: U-3 Lot Size: Deck: Type of Work: ACC Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:5,760 Valuation: $63,360 Building Height: 27 Occ. Status: Basement: AG bld Manufactured Home Information Setback Information Shoreline & Planning Information Make: Length: Ft. Front: N 309.0 Ft. Shoreline: Ft. Water Body: Cat III wetland Rear: S 20.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 810.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: W 30.0 Ft. Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Building State Fee MRr, innnnnn, -ta Sn r,77Fo Building Permit Fee MRr. 1 n/77/7nn• -Z7a1 7; 577RQ Plan Check Fee ki%Ai oil,>i,?nni -teR�1 A s717A EH Plan Review r.PM/ 0h1al7nn1 nn 9;77Ao Planning Site Inspection RAM ondnnm 0.7n nn s77ao Total $1,323.39 BLD2001-00952 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD2001-00952 During site inspection on 9/21/01 1 noted some excavation/disturbance in one of the wetlands. Counseled property owner on the need to obtain Mason Environrr in the future.` Area impacted is characterized by artificial drainage ditch established during earlier loggong practices. Recent work was done as maintenance of 1 CONDITIONS FOR BLD2001-00952 1) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X �Gv 2) This application is su ject to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X 3) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 4) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work w��ffect X your project. 5) Proposed structure or any portion thereof greater than 30" in height from grade line, must maintain a minimum of 5' setback from all property lines, easements and 10' from all County and State Road right of ways. X from 6) All upland areas disturbed or never reate by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X /J�� 7) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project. X 8) Approved per dimensions and setbacks on submitted site plan. X_ 9) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour(minimum 1 hour) will be charged and must be collected by the BuildinDepartment prior to any further inspections being performed or approvals granted. BLD2001-00952 Please refer to the following pages for conditions of this permit. 2 of 3 10). In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or X contractor fait tp post the address on site prior to requesting inspections. G✓ 11) The "approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee in the amount of$47.00 per hour (minimum 1 hour) will be charged and shall be collected Xy Mng Department prior to any further inspections being performed or approvals granted. 12) All property lines shall be clearly identified at the time of foundation inspection. X�� 13) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being X non-compliant with ason County ordinances and building regulations. l 14) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit er ha prevented action from being taken. No more than one extension may be granted. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. 1 OWNER OR AG ENT: BLD2001-00952 Please refer to the following pages for conditions of this permit. 3 of 3 I CONCRETE v1sT ,�r MECHANICAL MOBILE HOME Footings•Setback date by R+bboris date ' by /Z_ pas PpIng date by Founcladon Waal date by Set UP date by INSULATION date by BG/SLAB Insulation Fbors Final to by date date by FRAMING Wass FIRE DEPT.date by date by date by PLUMBING Attk OTHER Groundwork date by date by WALLBOARD NAILING D.W.V. date by date by FINAL INSPECTION Water Line rJ !n � date c y y �pZY L<� date by date by I/—/6 '�/ p!ri,ST�-,�o Gas ��9-ds G��.� .%t� �� <s it�i✓F O -�v�xS G (V 1 - Uk MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Processing/Inspections/Addressing Mason County Bldg.111 426 W.Cedar P.O. Box 186 Shelton,WA 98584 (360) 427-9670 Belfair(360) 275-4467 Elma (360) 482-5269 Seattle (206) 464-6968 September 24, 2001 Mr. Rolla B. Boughan Consolidated Engineering P.O. Box 2321 Bremerton, Washington 98310 Re: BLD2001-00952; Chuck and Marion Ernst Dear Mr. Boughan, Your plan for the building permit referenced above has been reviewed. This review letter contains only those comments related to the Building Department review and does not reflect any additional needs of the other county departments. Please review the following project data, and plan review comments. It is important that you then follow the instructions for re-submittal following the plan review comments. PROJECT DATA: Site Address: 1711 Toonerville Drive,Belfair Code Editions: 1997 Uniform Building Code, WAC 5140 1997 Uniform Plumbing Code, WAC 51-46,51-47 1997 Uniform Mechanical Code, WAC 5142 PLAN REVIEW COMMENTS: On page numbered 5 of 5 in the calculation packet, the U.B.C. edition 1994 is referenced, on the first page of the construction plans, the U.B.C. edition is not legible, as it has been altered. The Uniform Building Code edition currently adopted by Mason County is 1997. Please make the required corrections and/or clarifications and submit the revisions, marked on the sheets and noted with a cloud surrounding them or some other method of distinguishing the revisions. If only affected pages are re-submitted, arrangements should be made to remove the voided sheets and re-insert the new sheets into both building department copies of the submitted plans. Please detail all corrections and/or revisions in a transmittal letter to aid in a timely re- submittal review. Please be sure to reference the BLD number noted above to identify the file to which all re-submitted documents belong. Re-submitted plans are normally reviewed within 5 working days of the receipt of proper and complete revisions in our office. If re-submittal documents are incomplete or changes are made requiring additional review, an additional plan review fee may be charged at the rate of$47.00 per hour. If you have any questions regarding this review, you may contact me at(360)427-9670 extension 219. Si el ickerson, Plans Examiner Mason County Building Department 1711 NE Toonerville Dr. Belfair, WA. 98528 9/3/2001 To Whom Tt Mav Concern: The riding arena that we are requesting the permits for is to be used for private use only. Thank you, Charles Ernst Jr. i 1 PERMIT NO.: BLD MASON COUNTY a�lv BUILDING PERMIT APPLICATION 426 W.Cedar/P.O.Box 186,Shelton,WA 98584 Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 APPLICANT INFORMATION CONTRACTOR INFORMATION Owner rA,,c K a ,[yfA.-ions �rrs"� Contractor Name (3v.Id;N. SuJ+1P Mailing Address /7/I Too�C rv�(�ti b r. Mailing Address111? acL.Rl), CityIle-IF�t ' r State 1„tA. Zip Code_9d 3a�T City State L✓,a, Zip Code 93 Phone(?bo -77;2n,%J7oOther Ph.L ) Other Ph.(3t,o )7.31-60So Lien/Title Holder Contractor Reg. # So t✓ Address Expiration g /Z�/ SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septicy�Existing Septic ✓ Connect to Sewer S ste e S s ✓y m v Nam of ewer System Well Water System Name of v Water System PARCEL INFORMATION-12 digit Tax Parcel No. „r2 2�// /�5 / 6 0 Fire District Legal Description Site Address(Please include street name, street number and city)_ Directions tositeelo QtH o.v (le.or CrerKDeLja#D IZD. Fir-s-r LeF-'F aF+�.- U- fA^A,6►\ P,.ft RA, i r Ton.,a 11 p fir-. So'te i 1 /,or-1 bl.:re- a k Le H Will timber be cut and sold in parcel preparation? (Yes/No) 4/O Is your property within 200' of the following: Body of Water (Name) o Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs TYPE OF JOB New ✓ Add Alt Repair Other Use of Building Describe Work Pp�jp ±,.,u No. of Bedrooms No. of Bathroo s SQUARE FOOTAGE-1st Floor 2nd Floor 3rd Floor Loft Basement Deck Other- - r+f�U1 /Sfs rri A,r�„�q sq. ft.5 7e,0 Garage Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make Model ear Length No. of Bedroois No. of Bathrooms Type of Heat ��P rice $ Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COM'II ENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PfkOOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. Q X Date X Date FOR O F CI bUSE BEYOND THIS POINT Accepted by -7 Date Submittal Amount Due ?4 4Receipt No. �75% DEPARTME TALIR I EYV APPROVED CONDITION COOES Building D a 4 0", 1 Occ Grou etr. Planning Dep ent Environmental Health Department Public Works Department I Fire Marshal Valuation $ FEIrS Building Permit Fee Site Inspection Plan Review Fee UFC Plan Review Fee Plumbing & Base Fee Public Works Review Fee Mechanical & Base Fee Other Wood/Gas/Pellet Stove Fee Other Violation Fee Pre-Paid at Submittal ( ) > w..,.:..... TOT S «:.�. . AL FEE FORM MUST BE COMPLETED IN INK PLEASE PRESS HARD MASON COUNTY PROJECT SITE INFORMATION Case No.�?_ Name rhur l� Zr^­�st PARCEL NUMBERd'ZIJ// -75-00(4 Date - SHOW THE FOLLOWING ON SITE PLAN Show Direction by indicationg N, S, E, W in relation to the site plan Lot Dimensions Fences Existing Structures Driveways Structure Setbacks Shorelines Water Lines Topography Well Location (including adjacent) Drainage Plan Names of Streets Easements Names of Fronting Streets Septic System DRAW SITE PLAN BELOW Include adjacent properties if on shoreline or within 100 feet of adjacent property line. adjacent property line- I I Fadjacent property line I I I I I I I I I I I I i I I I I I I I I I C I I I I I I � I I � I I I I I I 1 I I I 1 I I I I I 1 I I 1 I 1 I I I adjacent property line-> ' ' E-adjacent property line SAMPLE SITE PLAN adja�nt property lined 3zo� _ _ _ f-adjacent property line D 30" rR�SCRvE 364 CREE{C \ I � fi HOM 6 i .GraatnJ I > PROP. I 1 , I � VACAkiT I fi Gy1tt AC.B I 3o i 1 � p0.oPosCD R\ � I� A6RLC,,VrL JMAL So 1 I I - I 8 0'—mil I \ I I � ' !" "e.LL I 1 I I I I x, /DO• I I ta�LL 1 I I lC I `V I adjacent property line-� Fadjacent ro ert line TOPOGRAPHY PROFILE(Show a side view of property. Show slopes, cuts and fills. If possible include height and the degree of slopes. See sample topography profile.) SAMPLE TOPOGRAPHY PROFILE Pro dtstnncQ pert y l s Ab st le✓e to rt �} d ca-'o r cL t o S/ y t�t s /O 3 I � 70ut Slops f a¢ J .+a..aa ,in AL Sig ature Date