Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2003-01042 Final MFG Home - BLD Permit / Conditions - 6/21/2007
Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Irflo Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2003-01042 OWNER: STEVE KENNEDY RECEIVED: 7/29/2003 CONTRACTOR: LICENSE: EXP: ISSUED: 9/26/2003 SITE ADDRESS: 1241 NE BLACKSMITH DR BELFAIR EXPIRES: 3/27/2005 PARCEL NUMBER: 223107900640 LEGAL DESCRIPTION: TR 64 OF SURVEY 11/17 PROJECT DESCRIPTION: DIRECTIONS TO SITE: MANUFACTURED HOME BEAR CREEK DEWATTO RD TO BLACKSMITH LK RD. FOLLOW PAST FORGE COURT TO BLACKSMITH DR. LOT ON LEFT MARKED WITH ORANGE General Information Construction &Occupancy Information Square Footage Information No.of Bedrooms: Type of Constr.: Type of Use: MH Insp.Area: OT No.of Bathrooms: Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No.of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make:GOLDEN W Length: 56 Ft. Front: W 195.0 Ft. Shoreline: Ft. Water Body: NONE Rear: E 597.0 Ft. Slope: Ft. SEPA?: No Model:OAKWOOD Width: 28 Ft. Shoreline Desig.: Side 1: Ft. N 100.0 Year:2003 Serial No.: N26993 Side 2: S 100.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Mobile Home Submittal Fee TW 7/29/2003 $211.05 S22003000 Planning Review Fee TW 7/29/2003 $150.00 S22003000 Mobile Home Issuance Fee JRN 7/30/2003 $211.05 S22003000 Building State Fee JRN 7/30/2003 $4.50 S22003000 Address Fee GMM 8/8/2003 $140.00 S22003000 EH Plan Review CEW 9/3/2003 $75.00 S22003000 Final Expired Permit KKK 6/4/2007 $64.o0 S22007000 Total $855.60 BLD2003-01042 Please referto the following pages for conditions of this permit. 1 of 4 f ' Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 ' Shelton,WA 98584 molt RESIDENTIAL BUILDING PERMIT BLD2003-01042 OWNER: STEVE KENNEDY RECEIVED: 7/29/2003 CONTRACTOR: LICENSE: EXP: ISSUED: 9/26/2003 SITE ADDRESS: 1241 NE BLACKSMITH DR BELFAIR EXPIRES: 3/26/2004 PARCEL NUMBER: 223107900640 PERMIT LEGAL DESCRIPTION: TR 64 OF SURVEY 11/17 NULL & VOID BY EXPIRATION PROJECT DESCRIPTION: DIRECTIONS TO SITE: y MANUFACTURED HOME BEAR CREEK DEWATT�Tb TO-B-L-AeK VtITM-LK . FOLLOW PAST FORGE COURT TO BLACKSMITH �FR�oL T O i LEFT I�(IARKED WITH ORANGE 4 � General Information Construction&Occupancy Information Square Footage Information No.of Bedrooms: Type ofConstr.: Type of Use: MH Insp.Area: OT No.of Bathrooms: Occ. Group: R-3 Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No.of Stories: Occ. Load: Building: Valuation: Building Height: Occ.Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make:GOLDEN W Length: 56 Ft. Front: W 195.0 Ft. Shoreline: Ft. Water Body: NONE Rear: E 597.0 Ft. Slope: Ft. SEPA?: No Model:OAKWOOD Width: 28 Ft. Side 1: N 100.0 Ft. Shoreline Desig.: Not Applicable Year:2003 Serial No.: N26993 11 Side 2: S 100.0 Ft. I Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Mobile Home Submittal Fee TW 7/29/2003 $211.05 S22003 Planning Review Fee TW 7/29/2003 $150.00 S22003 Mobile Home Issuance Fee JRN 7/30/2003 $211.05 S22003 Building State Fee JRN 7/30/2003 $4.50 §22003 Address Fee GMM 8/8/2003 $140.00 S22003 EH Plan Review CEW 9/3/2003 $75.00 S22003 Total $791.60 BLD2003-01042 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR BLD2003-01042 CONDITIONS FOR BLD2003-01042 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 2) In accordance with the Uniform Building Code, all sites shall have approved numbers or addresses located in such a position as to be plainly visible and legible from the street or road fronting the property. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X G- 3) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL.X 4) The"approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X �.. 5) Any retailer, manufacturer or contractor who installs a manufactured home warrants that the manufactured home is installed in accordance with the State Installation code, chapter 296-150M WAC. All installers hired to do installation work shall be certified manufactured home installers and shall be present to supervise the installation of all on-site work. An Installer Tag shall be posted on site giving the certification number and signature of the certified installer responsible for each major part of the installation. RCW43-63B.090 x � 6) If you are installing a manufacturing home and no longer have the installation manual for the home, you must use the instructions of the American National Standards Institute (ANSI). To order the ANSI instructions you may either get an order form from the Mason County Building Department or you can contact the Offfice of Manufacturing Housing (360) 725-2800. 7) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the 1997 UBC, and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. I further understand that this investigation will be scheduled as time allows. Until resolution of any/all problems no occupancy(Final Inspection)will be granted for the residence. OWN ER/CONTRACTOR(indicate which)Signature X BLD2003-01042 Please refert the following pages for conditions of this permit. 2 of 4 8) This permit is for the placement and installation of the manufactured home only and does not imply approval or review for any other items indidcated on the plot plan. X • 9) All mobile/manufactured home landings or decks must be freestanding (self supporting). The largest landing or deck allowed without drawings or a building permit MUST be under 30" in height from surrounding grade. NO second story decks, or decks above 30"can be built without a permit. Any landing or deck th t is 30"or more in height from walking surface to finish grade requires a Permit. Any landing or deck that has 4 or more risers requires a handrail. ti 10) Proposed structure or portions thereof with an projection over 30" in height from grade line, must maintain a 5'separation distance between adjacent structures and that furthest projection. X 11) The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the Uniform Codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspect r shall be made prior to requesting additional inspections. 12) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be clearly marked in the installation instructions. 13) All property lines shall be clearly identified at the time of foundation inspection. X 14) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Cswnty ordinances and building regulations. X/%-• 15) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 16) Approved per dimensions and setbacks on submitted site plan.X 4z: .- 17) All upland areas disturbed or newl ated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting).X 18) OWNER MUST SHOW R� �OF SATISFACTORY WELL LOG AND WATER SAMPLE PRIOR TO TEMPORARY/PERMANENT OCCUPANCY OF THE RESIDENCE. X BLD2003-01042 Please refer to the following pages for conditions of this permit. 3 of 4 e This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. OWN ER OR AGENT: < �' _ DATE: 2 S 0-3 BLD2003-01042 Please referto the following pages for conditions of this permit. 4 of 4 o`+ ONCRETE MECHANICAL MANUFACTURED HOME N M 0 w Footings r Setbacks Date By Ribbons Z Gas Piping rn o Inter►orDate By Interior-Date By Date By p N Exterior Date By Exterior-Date By Sit-up Point Lead!Isolated Footings INSULATION Date By BG!SLAB INSULATION Date By Data By FIRE DEPARTMENT r.m m Foundation Walls Floors Date By Date By Data Sy DECKS FRAMING Wads Date By Date By Data By PROPANE TANKS PLUMBING vault Data By Date By OTHER Groundwork Attic Type: Date By date By Date By D.W2V DRYWALL Type_ Int Brace Wall Date By W � Date By oAte By 17, FINAL INSPECTION Water Line Fire Sops ration CD By Date By Date �j�� �� By�L p m W Pass or Request Inspect. Type of insp. Fail Date Date Done By Comments CD o - -122 !77 Gl `x� / 717� Iv >� . xzr in O D fD O 7F C L f • • y N� i o CONCRETE MECHANICAL MANUFACTURED HOME o 0 ootin s' etbacks Lp4— Date By Ribbons o Dat 7/D3lok By Gas Piping Date By N Foundation Walls Date B y Set-up CPPn-e Date By INSULATION Date ,-3 -cP3 By B G / Slab Insulation Floors Final y Date By Date By Date By FRAMING Walls FIRE DEPT Date By Date By Date By PLUMBING Attic OTHER Groundwork Date By Date By WALLBOARD NAILING D.W.V. Date By Date By FINAL INSPECTION Water Line Date By T Date By ;.f"4-o � .y � �. Date By Z 03 z� - 1vtx E's See, A-rvc�ejLAG y 6 3 .. (0n lrCc ro e cu µ+.e �� w,�G� �y� AO za � -�j =li' / (i-✓.ram - C_...� l `-s' �� �� /r, fr�J_ I m / �e57 YQ�e- 72� 4,4AZz Cn 8 _ �v _a a� R!//vim �.L /-,�s'�, � L O cz- T W ' ~ y (1)A 6e-L 1,J 4Z- 03 D a C ' N ©3 Z -/,t:5> -t'-!� ,✓ ' 'ti-� <S - 11, 0 +._.__... tiers. ,I`It• ....._ r--_I —._--_ -----_--_ __.._---� !/p� r OPT.GChIlA:fta DA.TI{ nd o� Lu F' LL lJ r� CqLL �. o a -� N w ! �.__-• Hh.71 i �.— I W tt W tars c C� - ? BATH rJy KITCHIDjJtl fFfh_Y ACVj oa� O �' su cnt y I !/ �• Ojai � � _ Irasr - LING 11 1 �,{ BE z DEW„ oa, "V 3 PL 7 G t 0,•,naJ Hr.rlrl 0 wa.rt aA.7! I NAii NA r, H GRAND I tt THREE 13EDROOhi, T4VO BATH, OPT. BDRML 04 - 1,512 SR. F OAKWOOD HOMES ol.MY� ALBANY DIVISION — •fzs Iln! SALES FLOOR RP:Ut Y LYQ ALS&H s. �y 01-561F ] LEAHY, 6R PACIFIC Btvp, PLJgh� 97521 lu � 541 926-85JI phone pavl,l:/llt woINalPr I r�12 oau ElX 658-3552 (vz p�yYp,l 3-10-GI a - --- ALBAMY DIVIS10�7 J. HPIRY S ITT .n,x, —A 1 3-20-02 k � i Driveway and drainage diagrams This plan will move the current path of runoff from these parcels to provide a better arrangement of the driveways for both of them. The new runoff path will be open with sloped sides except for the portion that flows through a culvert where the driveways will cross it. Disturbed soils will be reseeded with pasture grass to return the area to the current conditions. Total volume of soil moved will be approximately 200 cubic yards. ?aR?31 ➢ . MASON COUNTY PERMIT NO. _...- BUILDING PERMIT APPLICATION 426 W. Cedar - P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the Web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner n Contractor Name r-c r C o c, Mailing Address O 13tt ,n , <, Mailing Address -1530 t. City -f Orcl.Aa I State Li i Code City Pert p-c�arc� State U/0 Zi Code gE3b'7 Phoneb92- t'•NSOther Ph. ( ) Phone (3 )_t5 S-Fsl/.Sather Ph. (3 64)3y�o'�.g Lien /Title Holder Contractor Reg. #PRE C.t"kP*. Email Address Email Address kr,PnM c -I a• on ,, I' C' SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System Well *�<Water System Name of Water System PARCEL INFORMATION - 12 digit Tax Parcel No. 22 3 n / _/ Co log{0 Fire District Z Legal Description QLnc kSn1�'/4 1-cl e suhd,'./,.""I, fleck L',+ 6q '7P'(2`�/�I,C Site Address (Please include street name, street number and city) Directions to site c t Q e l 5 '- +• r 4- of, Lef-I 9-il O Will timber be cut drid sold in parcel preparation? (Yes/No) A..0 Is property located within 200' of saltwater Lake River/ Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs PERMANENT RESIDENCE -• SEASONAL RESIDENCE ❑ TYPE OF JOB - New Add Alt Repair Other Use of Building Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action? (Yes/No) Describe Work No. of Bedrooms No. of Bathrooms SQUARE FOOTAGE - 1st Floor 2nd Floor 3rd Floor Loft Basement Deck Other sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make��eA UY odel Model Year 9_n03 Length 561 Width Serial No. N2(o993 No. of Bedrooms 3 No. of Bathrooms Type of Heat s- Purchase Price $ 5,, me). 00 Replacement Unit? (Yes/No) /V Installer Name Certification No. (pP.Tn15 32 1 NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. THE OWNER OR AGENT ON OWNER'S BEHALF, REPRESENTS THAT THE INFORMATION PROVIDED IS ACCURATE AND GRANTS EMPLOYEES OF Mason COUNTY ACCESS TO THE ABOVE DESCRIBED PROPERTY AND STRUCTURES FOR REVIEW AND INSPECTION OF THIS PROJECT. OWNER/BUILDER ACKNOWLEDGES SUBMISSION OF INACCURATE INFORMATION MAY RESULT IN A STOP WORK ORDER OR PERMIT REVOCATION. ACKNOWLEDGEMENT OF SUCH IS BY SIGNATURE BELOW: OWNER AFFIDAVIT- I certify that I am exempt from the require- CONTRACTOR'S AFFIDAVIT - I certify that I am currently regis- ment of the Contractor Registration Law RCW 18.27 and am aware tered as a contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and of the ordinance requirements regulating the work for which this that all work will be done in conformance therewith. No changes permit is issued and all work shall be done in conformance there- shall be made without first obtaining approval. with. No changes shall be made wi hout first oob ainirl royal. X Date X Date(5 r FOR OFFICIAL USE BEYOND THIS POINT Accepted by Planning Pd Date Bld Pd. 1� R e c i e p t No.a DEPARTMENTAL REVIEW APPROVED DENIED CONDITION CODES Building Department 01 30 U3 —7 Occ Group Type Constr. Planning Department Environmental Health Department Public Works Department C C I V ED Fire Marshal `1 v Valuation $ 426 FEES ST! Building Permit Fee 05 Site Inspection Plan Review Fee \` EH Review Fee Plumbing & Base Fee Planning Review Fee I S Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee State Fee rip Violation Fee Pre-Paid at Submittal / 1 TOTAL FEES I Ec.2ot- ZCo� Ec,zi•• *Avoid soil log j13 . Install the primary drain field where soil log #1 and #2 are located. � * Follow the attAFhed construction notes carefully. i I ' d C ,,e7)9,,/DG4„J Q° ° G8' 15L x Toc o856+cv/?nu..1 Po275 \S ` \ - a o \C 1 4F_Akl-5ur OD o 0 \ �!n ORAIELo 1 o a l PoMPr�i,i \moo J \ a o_ J o 2C�3, 57 PLANNING �'JN COUNTY OCU RECEIVED ,I i E PLAN REQUIRED TO BE ANGES SUBJECT TO APPRU. JUL 2 9 2003 QS y _Date 426 W. CEDAR STa suR1��y IIAOIP*a#f s .�wtY�y ..ro/�o�ivT A �--- � AlP-w cyty&.4 xs Li Poiwr- %�• i � c vc✓�cT Notes: • Scale: 1 inch = 20 feet. • Elevations are relative to the outflow of culvert beneath the current driveway. • Survey map for placement of this diagram relative to plot. • Excavated material will be used as fill centered around the point marked "D" on the map. This will be the location where the driveways will cross the low area. I )CJ*.f *WO' ANo PM-CA-4490 Mo`i FRox Pour- "I9" ro 1-itwr ��cls r/•v4 �i?oFiL�' Notes: • Horizontal scale: 1 inch = 20 feet • Vertical scale: 1 inch = 4 feet • The vertical scale is exaggerated for clarity. • This cross section profile is a side view of a line running from Point "A" to Point "B" on the plan-view map. E X coo rloa/ 440-ff s*C-iow ?Mc!A&t JfT POINT AorroH Notes: • Scale: 1 inch = 4 feet • This is a cross section view showing the profile of the excavation at the deepest location; approximately Point "C" on the plan view diagram. • The bottom of the excavation will be a minimum of 3 feet wide to ensure adequate flow area. This will minimize the flow rate and reduce chances of erosion. -- l C oht o v Dtrive woor Amo mA.ir/e s CRotf McTiav v«w (A"W61- wasr) 30� TD 1'AL /FAf�/tilt�%J' bv/d Tiy AS ,D�w�rwi►y ur��ry Notes: • The diagram above shows the typical view of the arrangement of the driveway, the utility trench, and potential ditch within the easement. • The utility trench will contain a 7200 volt power line that must be buried at least 3 feet below the surface and must be at least two feet from other contents of the trench. This sets the dimensions of the trench. • Ditching may be needed in some locations on the south (left in the diagram) side of the road. This will be included as needed during construction. Well house utility trench Notes: • The well house utility trench will contain a 220 volt power line and the water line that will supply the houses on both of the parcels. • The trench will be a minimum of two feet deep and wide enough to allow adequate separation of the contents of the trench. • The trench runs from the well house in a northerly direction to the utility trench in the common driveway/utility easement. From that point contents of the well house trench then will be included in the main trench. r .� ����r/�- `A pw � I -=0" �U J C IV --2o�r r , L ac#7-i0-v ai �tavr� i d r �"lyl�N /�O/ari o� �1 D rrlr �rTit�.rT C R&.4T1 1,w 0JC1-,CV5f7-1*A1) Topological map to locate house site on Funk property on Stretch Island. Notes: • Scale: 1 inch = 20 feet • Elevations are relative to the high point of the ridge crest, as marked on map. • Survey markers are indicated by heavy dots. • House is located 65 feet from the nearest edge of the top of the bluff and 60 feet from the north property line. • House is aligned such that its north and south walls are parallel to the north and south property lines. • See the survey map and the geotech report for more details