Loading...
HomeMy WebLinkAboutBLD2023-00563 MFG Home - BLD Application - 11/14/2023 Well radius for 22 -79-90664 +0' el 184.83 +7'el °� Adjoining property Q wetlands are 150'off yr�6 o t Parking& �\o� QsS� 0 o I Turnaround L�6 the northwest property m n Area �� corner,270'from the a. o proposed structure j / V � VB J Pump"•......,. / N Tank Septic Tank 100% 6os / \ I Reserve 1°0 P er SO 300 �i:•P' pa e Q�°e �°� 00 Downspout Drainage f oo��. .•y Q�c�`ca�.r:. Line to daylight �` C: ti�. Planned \ yr Rain Garden/ a Runoff Well Retention in -ew�5a� House Area N ro Pie �• �et�e Proposed o� E y' Well Sea`' �a o N -0 c: Y U `\ .E N (D En c E E = ) o W �e a `P Cz NNN - CD () N 1 EH APPROVED 0 �, Cz ° (0 o LL cn � , a. Rhonda Thompson 11/13/2023 �1 c ' _ I o > +5' el 184.46' +9'el V (D p Q co 0 L N o Building Site Plan Name: Marcinko Tax Parcel: 22310-79-90663�� � Q� E � � a co o •; W Scale = 1" = 40' Address: 797 NE Blacksmith Or, Belfair Q N U > N J Cz � `-' EH Setbacks a 0 td A.) Draintie Id/Reserve requires 10'setback from footing/foundations B.)Septic tank(s)requires 5'setback from all footing/foundations C.)No foundation/Perimeter Drains within 30ft,downgradient of Drainfield/Reserve area D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area Name_ �N�N�r � Parcel# .. 79 q 1QO BLD40Id 202 JOO 15 IV J Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only aft?r Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" # PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A)'Awhe relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B, _ An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT. 450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. / X Owner/Agent/Contractor(circle one)Date: sl�G2-5 Page 2 of 2 Name /rIN/('Ciln o Parcel# 2 31(i --49 - 9 0101 3 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X 3. 1 = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X = Parking Areas X = !� (pQ Snc( i T = Any paved, gravel or packed area per definition above table X = PatiosMalks m.431 X to 1 = 93.3341 /Lq i 1 X Lt = .5 Any paved,gravel or packed area per definition above table X _ Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 3 .2 If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for revi and inspection as ay be required. /� l X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Mason County Community Services-Building Division MANUFACTURED HOME PLAN REVIEW SPECIFICATIONS UNIT INFORMATION: Snow Load Z4 Make Model _ y &2, Square feet q10 Width �� I Length 2tj) ?i3 ) D 4) Singl /Doubt triple-wide (indicate) NEW or Replacement(indicate) All footings must be min. 12" below grade within 24"of the skirting when perimeter blocking is required. When manufacture specification is not available use ANSI A22S.1 or HUD 24 CFR 3285. Must provide pier plan with reference sections. Allowable Pressure(Pound Per Square Foot)No Allowances made for overburden pressure,embedment depth,water table height,or settlement problems Soil bearing is assumed at 1500 psi If set-up is using a greater soil bearing capacity a soil report from a design professional is required Fill(compact or uncompacted) Compaction Report required through Special analysis Peat or organic clays Compaction Report required through Special analysis SET UP SPECIFICATIONS: b Manufacturer' Pier Plan X ANSI A225.1/HUD24 CFR part 3285 FOUNDATION: Check the type of foundation and attach detail plans from manufacturer's or the ANSI A225.1/HUD24 CFR part 3285 O Pads O Continuous concrete footing(runners) X Slab ANCHORING: O Ground O Magnum 1X Concrete-2500 PSI 1 J-bolt Expansion bolt For new units,this information can be obtained from the home retailer or contractor. Previously owned units,which manufacture's instruction are not available must utilize the ANSI A 225.1/HUD24 CFR part 3285 code for installation. Washington State law requires that a certified installer install manufactured homes. The undersigned I hereby acknowledge he/she does understand that the Mason County submittal and review processes will be based on the information provided herein and will be verified at time of inspection. X Applicant/Dealer/Installer(indicate) Date MASON COUNTY Permit No:'/?)I 61 202,�5 -006V3 COMMUNITY DEVELOPM]K: tIVED NBC Permit Assistance Center, Building,Planning MAY 18 2023 BUILDING PERMIT APPLICATION 615 W. Alder $treqMn PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: 14,RLb NAME: fl'-11L14. UzeA#6 NAME: �rtA,rlL - ""= MAILING ADDRESS: 5617MAILING ADDRESS: CITY:S-etyAtfjG STATE:_ IP: 6 CITY: STATE: ZIP: PHONE#1: L1dJ _ CELL: PHONE#2: AAA ) 162-1 EMAIL : ----- EMAIL: L&I REG# EX . PRIMARY CONTACT: , OWNERY CONTRACTORX OTHERXs-�/G- ben n0/-:; NAME_�fA44k A Ad&rG 4 EMAIL �S MAILING APDRESS CITY STATE ZIP PHONE CELL PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) .9t A 3 ZONING Stil iG AftlI 'S LEGAL DESCRIPTION(Abbreviate ) ►- FIRE DISTRICT#IqSn thn¢ SITE ADDRESS 7qJ WE 81ackS of S p 9S90�—Jn VVb4 5 DIRECTIONS TO SITE ADDRESS,�d _ ENE Sm I�h�, F ie Ln- Am d NA a ��- Q� IS THE PROJECT WITHIN no FT OF SLOPES)GREATER TEIAt`J t4a/'.: YES❑ NOX SNOW LOA J: A5 psf I IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER❑ LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF❑ STREAM ❑ TYPE OF WORK: NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER USE OF STRUCTURE (Residence,Garage, Commercial Bldg Etc) IS USE: PRIMARY % SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS 2. HEATED STRUCTURE? YES (whole Bidg)X YES(Part[sj of Bldg) ❑ NO ❑ff'� DESCRIBE WORK De( ' d ft 1a NbW A4 4 SQUARE FOOTAGE: (proposed) 1 ST FLOOR�•�q. ft. 2ND FLOOR sq.ft. 3RD FLOOR sq. ft. B A QFA,mi T'r _ _sq`ft.- DECK _ _ I.& COS,/EWDECK 195 sq. ft. STORAGE sq.ft. OTHER 1 � 'VrJ r tq.J.-Y - ' GARAGE sq.ft. Attached❑ Detached 0 CARPORT-- - --- - --sq. ft. Attached Q Detached MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE F1 f e+ulood MODEL Bf en'rg+11Y) YEAR Z LENGTH (� WTDTH_ 3 BEDROOMS _ BA''TH��S Thy SERIAL NUMBER�/�I F) Q z 31A6q ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTICQ` SEWER❑ / NEW J;� EXISTING ❑ PLUMBING IN STRUCTURE? YES 54 1 yf✓ NO❑ If yes, attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES [J NO� EXISTING SQ.FT. EXISTING BEDROOMS_�� PROPOSED BEDROOMS�_ TOTAL BEDROOMS Z OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by srguawce uewuu, e`r r udr.a 04de s d e uf Sues wHe tf r-dHH s fURHeP esrdrts that t drti diitkled td receive tHly permit and to do the work as proposed.1 have obtained permission from all the necessary parties;including any easement holder or parties of interest regarding this project. The owner or legal rPnrPQPntafivP ranmcantc that tha infnrrnatinn nrnviriori is acruratP anri nrantc PmnlnvPPc of 11Aacnn r',ra infix accPcc to the ahnva riPcrrihPri nrnnarty