HomeMy WebLinkAboutFIR2024-00033 - FIR Inspections - 3/4/2025 Mason County Fire Marshal 615 W.Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 Fire Alarm Certification/Final Test FIR /�Jf'<,YX��:' Location: Contractor: Phone#: Contact: ,/�,�,�; , /os�� Test Date: lzs9 z5 CHECKLIST Verify panel is in "Normal'condition and clear of any signals ✓ Kill Power At Electrical panel &verify dedicated circuit, red breaker& lockout ✓ AC Trouble/No Power displayed? Activate device(s), verify it activates the alarm and shows correctly on the panel Check the Notification Alarm Circuit(NAC)for activation of devices.Walk building while alarm is activated under battery load. Check for all lights and sounds to be in-sync .J Silence Alarm Activate a few other devices in different areas to verify alarm reactivates after being silenced Reset Alarm Does panel still show trouble (due to AC power)? ✓ Disconnect Signal Loop Circuit(SLC)to create/verify a trouble for each device on circuit Reconnect SLC. System should reset& only AC trouble showing yi Disconnect the communication line&verify communication trouble Do batteries AMP/HR match plans? FACP Sign on Door(s) leading to panel location? Device Test Log Notification Device Time Comments Water flow Inspectors test Smoke detector at FACP Tamper switch 1 /l/ Tamper switch 2 4/ Manual pull at � y� Manual pull at Manual pull at Heat Detector Lj Heat Detector Heat Detector Heat Detector Heat Detector Smoke Detector Smoke Detector Smoke Detector ',- /2 o Punch List/Comments: Passed Final Test? Yes V No SYSTEM SENSOR° Indoor Selectable- Output Strobes and Horn Strobes for -_ Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING U` naaaoveo LISTED 55512 FM approved except 7125-f653:0504 S40t1 for ALERT m dels 7135-1653:0503 3057363 AVDS86U2.12101,,2017•Page 3 l ' L-Series Specifications ArchitectlEngineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75.95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PhysicaltElectrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5'high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9'diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02.12/01/2017•Page 2 w r UL Current Draw Data UIL Max.Strobe Current • UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UIL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe • .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVOSS68-02•1 210 11201 7•Page 3 L-Series Dimensions 2.47'(62.7 mm) 1.37'(34.8 mm) 6.92'diam. 2.5' - 6.83'diam. (175.77 mm) (64 mm) (173 mm) i a O c CD c0 O O O O O o CDo 0 Aos4so0 A0546-00 ' Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box a 0 ° O 0 O A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire, Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". �� .SYSTEM 02017 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specrfications subject to change mftut notice.visit systemsensor.com �� SENSORA Phone:800-SENSOR2•Fax:630-377-6495 o cunentpoduc information,including the stversonof hisdaasheet. AVD5868-02.1 J01J2210112017 -PDPAD300 (E,) POTTER The Symbol of Protection Photoelectric Smoke Detector Features • Low profile,less than 2 inches with the base • Wide selectable sensitivity range of 1.1 to 3.50/o/foot • Detector communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting,no programming tool required • Magnetic test switch • LED alarm indicator • Product includes 5-year warranty • UUKL Listed for Smoke Control • L L268 7th edition compliant p U� 032M541 Description Technical Specifications The Photoelectric Smoke Detector is a listed Analog Addressable smoke detector compatible with fire alarm control panels that utilize Operating Voltage 24 VDC the Potter Addressable Device(PAD)protocol.The PAD300-PD is a low profile smoke detector with a wide sensitivity range.The detector Detector Current Draw 300 µA and base are made of a durable plastic in an off-white color to blend in with the ceiling. Alarm Indicator 1 LED The PAD300-PD has a sensitivity range of 1.1 to 3.5%per foot and is Alarm Set-point Range L I to 3.5%/ft(3.6 to 11%/m) UL listed.The PAD300-PD features drift compensation and has built in dirty detector warning as well. The PAD300-PD and the control Installation Temperature Range 32 to 120°F(0 to 49°C) panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. Operating Relative Humidity 0%to 93%(Non-condensing) The total polling speed is less than five(5)seconds,well under the UL range requirements. Start-up Time Max. 1 sec. The detector is compatible with any of the PAD300 series detector bases and simply twists on.The PAD300-PD is addressed using DIP Maximum Number of Addresses 127 switches in the rear of the detector and can be easily programmed in Per Loop the field without special tools. Maximum Number of Lighted Indicators in Alarm Per Loop 30 Setting the Address Each addressable device on the SLC loop must have a unique address Color Eggshell White from 1 to 127 to function properly. The address is set using DIP Weight(without base) 91g(3.2oz) switches. Before connecting a device to the SLC loop, take the following Height: 1.42 in(36mm) precautions to prevent potential damage to SLC or device.Verify the Dimensions(without base) Diameter:3.93 in(100 mm) following: 1.Power to the device is removed. 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830216-REV B 2/23 PAGE 1 OF 2 (E) POTTER PAD300-PD The Symbol of Protection Photoelectric Smoke Detector Air Velocity Ratings The PAD300-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD300-PD will operate even though the LED may not illuminate. Operation The PAD300-PD is an analog addressable detector that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD300-PD with the PAD300-4DB or PAD300-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The detector includes an insect screen to prevent foreign objects from reaching the chamber and can be cleaned to restore operation of a dirty detector. Detector Sensitivity The PAD300-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the detector is installed over time,the detector compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty detector.The detector will then have to be cleaned or replaced. The PAD300-PD can be programmed to provide a maintenance alert prior to reaching the dirty detector level which will allow for intervention prior to the detector going into trouble. This allows for detector replacement or cleaning prior to a nuisance trouble occurs. NOTE:As required by NFPA, do not install the detectors until all construction is complete and the work area has been thoroughly cleaned. If the detectors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PAD300-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang,3-1/2"octagon,3-1/2"square,double gang,4"octagon,4"square,50mm c/c,60mm c/c and 70mm c/c boxes. Device Description Stock No. PAD3004DB 4"Detector Base 3992781 PAD300-6DB 6"Detector Base 3992782 PAD300-IB 6"base with an isolator module included 3992783 PAD300-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 13992784 PAD300-SB 6"base with sounder module included.Sound pattern is provided from external source 13992785 PAD300-LFSB 6"base with 520Hz sounder module included.Sound pattern is provided from external source 13992786 Ordering Information 1I odel Description Stock No. PAD300-PD Photoelectric Smoke Detector 13992775 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830216-REV B 2/23 PAGE 2 OF 2 (R) POTTER PAD300-H D NS atfthatim Heat Detector Features • Selectable Rate of Rise and/or Fixed Heat Detector • Low Profile • Reliable Detection Technology • LED Alarm Indicator • Ambient Temperature Listing of 32°F to 150°F • Simple DIP Switch Address Setting,No Programming Tool • .r ` Required too ,. • Magnetic Test Switch • �+" • Product includes 5-year warranty • UUKL Listed for Smoke Control i u.�s-os,s Description Technical Specifications The PAD300-HD is a listed analog addressable rate of rise and/or Operating Voltage 24 VDC fixed temperature heat detector compatible with any fire alarm control panel that has the Potter Addressable Device(PAD)protocol.The heat Detector Current Draw 300 µA sensing portion utilizes a proven thermistor for accurate and reliable Alarm Indicator 1 LED heat detection. The detector and base (not included) are made of a Alarm Set-point Range 135°F to 185°F(57°C to 85°C) durable plastic in an off-white to blend in with the ceiling. Rate of Rise Detection 8.3°C/min. The PAD300-HD is UL listed with a selectable fixed temperature (Selectable Option) 15°F/min.( ) point from 135° to 185° Fahrenheit and can be used for rate of rise applications. See detector spacing limitations below.This flexibility Installation Temperature Range 32°F to 150°F(0°C to 66°C) allows the installer to cover a wide variety of applications with a single unit. Operating Relative Humidity The PAD300-HD and the control panel communicate over a proven Range 0%to 93%INon-condensing) and robust digital communication path and the system analyzes the Start-up Time Max. 1 sec. information at the particular device.The total polling speed is less than Maximum Number of Addresses five(5)seconds,well under the UL requirements. Per Loop 127 The detector is compatible with any of the PAD300 series detector bases and simply twists on.The PAD300-HD is addressed using DIP Maximum Number of Lighted 30 switches in the rear of the detector and can be easily programmed in Indicators in Alarm Per Loop the field without special tools. Color Eggshell White Setting the Address Weight(Without Base) 68 g(2.4 oz) Each addressable device on the SLC loop must have a unique address Height: 1.5 in(38 mm) from 1 to 127 to function properly. The address is set using DIP Dimensions(Without Base) Diameter 3.93 in(I00mm) switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device.Verify the following: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 88302I0-REV C 6/23 PAGE I OF 2 (R)POTTIER PAD300-H D ft&A"dt Heat Detector Operation The PAD300-HD is an analog addressable detector that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LED flashes every time the unit is polled and it will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD300-HD with the PAD3004DB or PAD300-6DB has a low profile to blend into the surrounding environment.The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD300-HD will operate even though the LED will not illuminate. Spacing The ANSUUL listed spacing limitations of PAD300-HD smooth ceiling are dependent on alarm set point. Alarm Set-Point Rate of Rise Spacing Fixed Temperature Spacing 135OF to 1850F (57°C to 85°C) Max.70 ft. Max.70 ft. Compatible Bases All bases will mount on a single gang,3-1/2"octagon,3-1/2"square,double gang,4"octagon,4"square,50mm c/c,60mm c/c and 70mm c/c boxes. Device Description Stock No. PAD300-4DB 4"Detector Base 3992781 PAD300-6DB 6"Detector Base 3992782 PAD300-IB 6"Base with an Isolator Module Included 3992783 PAD300-RB 6"Base with One Form-C Relay Contact 2A @ 30VDC,0.5A @ 125VAC 3992784 PAD300-SB 6"Base with sounder module included.Sound pattern is provided from external source 3992785 PAD300-LFSB 6"Base with 520Hz sounder module included.Sound pattern is provided from external source 3992786 Ordering Information Model Description Stock No. PAD300-HD Heat Detector 13992776 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830210-REV C 6/23 PAGE 2 OF 2 1�15G LTE - M CELLULAR TG = 7FS C 0 M M U N I C A T 0 R FOR COMMERCIAL FIRE THE ALAPM COMMUNICATION EXPEPTS d COMMERCIAL FIRE Part of the full line of Telguard universal fire communicators, the TG-7FS can augment or replace legacy Telco lines with reliable cellular signal reporting. AHJs know that the TG-7FS meets all UL and ULC standards, and works in virtually every installation. PRODUCT FEATURES 5G LTE-M 4- Powers directly from a 12 or 24VDC alarm panel — no electrician T' needed for an outlet. Or, for AC, use included plug-in adapter. Operates on LTE-M networks, for 5G longevity, lower power consumption, and better in-building penetration. w- Interfaces with fire panels using a single DACT connection for universal compatibility. No DACT is no problem — just add a TG-PEM accessory to the TG-7FS. i- American made, and backed by award-winning, U.S.-based tech support. This is the communicator dealers have loved for over a decade, updated with a more modern 5G LTE-M cellular radio, more efficient use of power, and more options. You're in control when setting up and installing the TG-7FS. Apply desired settings when you're in the office or on the road using the Telguard online dealer portal. Signals can be reported to your central station of choice. CommercialUL Listings(AT&T and Verizon) Size (without antenna) Specifications 864 Consumption. • Central Station • Standby. 18mA co 24VDC Only)ULC Listings(AT&T Contents 40mA &12VDC S559 Commercial Fire TG-7FS universal communicator Transmit: 110mA 8L 24VDC S304 Commercial Burglary Antenna with extension cable 200mA Eu 12VDC AC adapter • • blocks Models by Carrier CID, SIA, Pulse(4x2,3xl), Canada): Verizon(US • to connect •• panels Range of antenna cable lengths High-gain . • 0 External antenna NFPA V USED For the most current product specifications and UL Listings visit telguard.com/tg-7fs.In Canada,cellular data may be carried by Rogers,Bell,Telus or SaskTel. CHOOSE THE COMMUNICATOR THAT BEST FITS THE NEEDS OF YOUR UPGRADE, TAKEOVER, OR NEW INSTALL PROJECT. COMMUNICATION PATHWAYS INPUT POWER OPTIONS MO Z�LULAR iM01:4M!M%r4& gram., TG-7UB 800.229.2326 13225 Cumberland Blvd SE•Suite 300•Atlanta,GA 30339•USA I telguard.com .�►METEK�•c 2021 Telguard I Telguard and the Telguard Logo are registered trademarks of Telular Corporation.I Telular is a business unit of AMETEK,Inc.All Rights Reserved.