Loading...
HomeMy WebLinkAboutSWG2025-00026 - SWG Application / Design - 1/30/2025 415 N 6TH STREET,SHELTON.WA 98584 MASON COUNTY SHELTON:360427- .EXT 400 BELFAIR:360-275-44674487,EXT 400 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX:360427-7787 On-Site Sewage System Permit: SWG2025-00026 0Vr�'1 APPLICANT STEPHENS CHARLES&JULIE Phone: Address: 18004 SE 282ND CT KENT,WA 98042 OWNER STEPHENS CHARLES&JULIE Phone: Address: 18004 SE 282ND CT KENT,WA 98042 SEPTIC DESIGNER DALE TAHJA' Phone: 360463-8023 Address: 2450 W DEEGAN ROAD WEST SHELTON,WA 98584 SEPTIC INSTALLER CRAIG SHOCKMAN Phone: 206-734-1869 Address: 90 Quetilquasoon Road MANSON,WA 98831 Site Address: 221 N WEBSTER LN Primary Parcel Number: 224065100008 Permit Description: Repair 2bd Oscar II Permit Submitted Date: 02/03/2025 Permit Issued Date: 02/19/2025 Issued By: Rhonda Thompson Current Permit Fees Paid: $825.00 (abditional fees rear be regwned upon matalmon O "on. Permit Expiration Date: 02113/2026 (based on dale a inspection) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. 4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic Designer/Engineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for final installation approval. THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.govlhealthlenvironmentallonsiteloss-Inspection-request.php or call: 360.427-9670, extension 400. OFFICIAL USE ONLY MASON mmu=nCOUNTY nlM NNIB,I �SWG TMOW eD "- OOOZO COMMUNITY SERVICES ao A w ON-SITE SEWAGE SYSTEM APPLICATION m PHONE Charles es Stephens (206)510-1431 c NAILwaAmREss-srflEET,clrv.sTATe,m \h 1 WA 98042 = M 18004 SE 282nd Ct. iJ m A SITEMgtE66-BTPEET LT',31P COO" 221 N. Webster Ln. o Lilliwaup WA 98,555 { (" HMIEOF CESIONER O Dale L. Tahja m (360)463-8023 N NWE OF MSTPI u- PHONE { Craig Shockman (509)449-3232 FFFNIITIE(M _) CC IXtINKING WATER SOVRCE O I O 9RESIDENTIFLOSS L.NCC11 COMMUNRYOSS F11COMMERCU1066 EIPRNATEINDNIDUALW U. EOFRNATETNOPARTYWELL 2 { 0) TYPCE O1P WORK fraa arnl PUBLIC WATER SYSTEM TMN^ne. . EA, , NEWCONSTRUCJDNIUPGRADEs ®REPAIRIREPIACEMENT OTNIJI pETALR(NNd NxwaxHl 0WLE IX REPAIR I IT SUBcMI�I'TMS OSURFACINOSEWAOE OEXISTWOFAILURE 064ORELINE PSDESKSN FORM(REGU WED) �EPTIC DESIGN(REQUIRED) EEDRCONS LOTaIEE 0 I CC�T � SyiWANEIi(6)(IF APPLICABLE) 2 0.73 acre x { O OIFECTKPAS TO BIIENIO AlECIX1DIfION6:0c AxlieCpb) Go north on Hwy 101, right on Webster Lane, property on the left, directly across from N. CD Bow Tree Lane. c I o ti O 00 co MEYUDIBEMOOEDFRONMAM ROAD A/Y11EdTXNETW615EiLA40E01Ml1ITEYT/KKENWMERA OFFICIAL USE ONLY BELOW THIS LINE IIPORPDEUNTARE SONWE(b NI.aINB MF MPI O VOLUNTARY OMAINTENPNCEDRIMPING OBNLDING PERMIT OHOME SALE OCOMPLAINT DOTHER'. INSPECTON601LLOGs CCT.M.',,ONORIQYS r ✓6 `{ W 2 Z Ti= 0-zA ESL vA V, v�3 7M S an.k 0„5 RECDRD DRAwwo ANG lrvsTsaLAnaN REPGRr aO eaoec y-y GIGRAVELLY S=SMO L=LOM1 NzSILT C=IXAY E=EXTREMELY ft=flWTS REWIRED FIXiFMLLAPPRMPL. INSPECTOR SIGNRTURE WTE MPLICATXHI FJPHUTION WTE APPLILATIONM+ROVEDf ISSUED BY DATE nI , qA v- LLG Lh2±jW TNMFORMMAYBE NEDANDAVAILAMLEFORPUBLICVEWOMTNEMABIXICOUMYV1EB61TE REVISED lw.'s DESIGN FORM—PAGE ONE Assessor's Parcel Number: 2 2 4 0 6 — 5 1 — 0 0 0 0 8 A design will be reviewed when 3 coda of each of the following are sal n fitted: •Completed design form that has been signed and dated. Scaled layout sketch,including all applicable items on checklist v Scaled plot plan,including all applicable items on checklist. I Cross-section sketch,including all applicable items on checklist. This form may be scanned and available for pudic view on me Mason County web site.Maximum Paper size 11"X 17" PARCEL IDENTIFICATION QO -00026 Dcsi er's Name: Dale Tahla [Applicant's it Numbtt: SWG 2� � 3604286940 Name: Charier Stephens Designer's Phone Number:ing Address: 18004 3E Mod LY Designer's Address: 2450 W Deegan Rd W \hqA(\ WA a9042 Siwlbn WA aB580 C' State Zi citystate Z' NPARAMETERS Treatment Device ❑Glendon Biofit= ❑Sand Filter ❑Monad ❑Sand Lined Dr unfield ❑Recirmlating Filter,Type: ❑Aerobic Unit MAdModel ❑Disinfection Unit Make/Model Oche: WA Drainfield Type ❑Gravity ❑Pressure 0 Trench fit(Bed Ef Sub Surface Drip Septic Tank/Dr tinfseld Specifications Laterals Number of Bedroom 2 Schedule/Class OS-100 coils Daily Flow:Operating Capacity 180 god Length 7X7 ft Daily Flow:Design Flow 240 gpd Diameter Netafim Bioline in Septic Tank Capacity(working) 1,000 gal Number 3 Receiving Soil Type(1-6) 4 Separation 1 ft Receiving Soil Appl.Rate 0.6 gpd/ftt Orifices Required Primary Ara 400 ftt Total Number of Orifices 300 emitters Designed Primary Ara 400 fit Diameter Netafim Bioline in Designed Reserve Area 400 ftt Spacing 100 emitters/coil in Trench/Bed Width 16 ft Manifold Trench/Bed Length 25 ft Schedule/Clam Sch.40 Elevation Measurements Length 260 ft Original Dramfield Area Slope 14 % Diameter 1 in New Slope,If Altered 13 % Preferred manifold configuration used? 0 Yes Iallo Depth of Excavation U"10a 0 in Transport Pipe from original Grade gown-slope 0 in Schedule/Class Sch.40 Designed Vertical Separetion 25 in Length 5 ft Gravelless Chambers Required? ❑Yes id No 0 Optional Diameter 1 in Pump Required'/ 510 No hosing and Pump Chamber Pump/Siphon Specifications Number ofdosa/day 360 Diff.in Elevation Between pump&Uppermost Orifice 25 ft Dose quantity 0.67 gal Drainfield Squirt Height/Selected Residual(head) drip it Chamber Capacity(flood) 1,000 gal Uppermost Orifice Of ❑Lower than Pump Shutoff Pump controls:Please check those required capacitycapacity(a)Total Pressure sure R Head 30 gpm Timer Bllifflapse Meter G(Evem Counter Calculated Total Pressure Head 30 fl If Timer: Pump on 0.32 min Pump off 3.52 min Comments Audio/Visual Alarm required. This system replaces the existing system and meets new construction standards. \ 0. DESIGN FORM—PAGE TWO Assessor's Parcel Number:2 2 4 0 8 — 5 1 — 0 0 0 0 8 Permit Number. SWG ': DE9I(iN L"�UkYf.Ih :� . rd Plot Plan Scaled Layout Sketch Cross-Section Sketch st hole locations 19 Drainfield orientation and layout Reference depth from original grade: il logs 56 Tranch/bed dimensions and � Septic tank operty lines critical distances within layout 19 Draintield cover ig D-Box/Valve box locationsxisting and proposed wells Reference depth from original grade ithin 100 ft of property R1 Septic tank/pump chamber and restrictive strata: 1Z Measurements to cuts,banks,and locations l5 Laterals,trench/bed,top and surface water and critical areas 19 Observation port location bottom m Location and orientation of 19 Clean-out location ❑ Curtain drain collector curtain drain and all absorption 56 Manifold placement 19 Sand augmentation components 19 Orifice placement Other cross-section detail: Location and dimension of R1 Lateral placement with distance Sf Observation ports/cleanouts primary system and reserve area to edge of bed Other Information Id Buildings 1f AudibleMsual alarm referenced Yes No 1J Direction of slope indicator E6 Scale of drawing shown on scale 21 ❑Design staked out m Waterlines bar ❑ ❑Recorded Notices attached Ib Roads,easements,driveways, ❑ ❑ Waiver(s)attached parking E6 ❑Pump curve attached Id North arrow and scale drawing ❑ ❑Evaluation of failure shown on scale bar Non-residential justification ❑ ❑Waste strength ❑ ❑ Flow DE$16NAPP$(1�i1(+ The undersigned designer` b�e nottiified b ''nsi'ali�`at time of installation Yes ❑ No Signature ofDesigner Date The undersigned has reviewed this design on behalf of Mason County Public Health and � i- compliance with state and local on-site regulations: Environmental Health Specialist M cwi CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING COND %Yp ✓ The design is stamped"Approved"by Mason County Public Health. ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Dminfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County Web site. dated Dart: 17/72015 2�` \�l•�eb�Er L.�n I y 1 e 51002 02 'Jak L Tahje LICFNSED DESIGNER .� O 7J7` 1 y � 4 ON _ . fi.__S1ITCVV �t�\V APPROVED FEB 19 2025 J MASON COUNTY ENVRONMENTALHEAUN RET � FEB 19 2025 MASON COUNTY E AR NMENTAL HEALTH �c AS�c �'l C• 33 Say 4 a 1 bale L WO LICENSED DESIGNER mioo Coil Datell: mom { 1 5y \ � / 1 1 °°°• �� 51 0021 Dak L.Tahja LICENSED DESIGNER The OS-10D OSCAR GMt M taha faD 0.42 yph NeWM emitters in a SD sq. ft. fact prmL Emitter cwmmw ton ls 2 emitters per sq. ft. Desipn flow for each Osf 00 is too gpa. x NSF APPROVED FEB 19 2025 MASON COUNTY ENVIRONMENTAL H RET Thermoplastic Reinforced Thermoplastic motor bracket and discharge with bui77: p has a stainless steel top bearing and motor coupling.These are assembled with our A.Y.McDonald stainless steel motors.Two wire single phase models include pump,motor,and 10'lead. This four inch submersible is supplied with grounded leads meeting the National Electrical Code(N.E.C.)specifications. The performance curve below will assist you in choosing the pump that meets your needs. I MODELS E-36 GPM 00 e - 30OPM lair IIItL NPSL IN _j- _ _ T_ i I L re 1N IJ2me•4STA�GT I 1 e u N 40 N N Ft N FWON a N N N N dN tN tN in FLOW GPM APPROVED Specifications FEB 19 2025 Lora' trz Plank 115 1 1 1 10.94 1 953 1 211ASON COUNTY ENVIRONMENTAL HEALTI' RER,s SUOMFFTALINFORMATION - stainless steel pump shell and pump shaft - Powered by A.Y.McDonald submersible matins lU2 HP. - Reinforced Thermoplastic diffusers and impellers - 111V FNPT Discharge - Thermoplastic intake screen and cable guard N04L O:The weighted average of the wetted surface of this na-lead product contacted by consumable water contains less than one quarter of one percent(0,25%)lead. Lowridge Onsite Technologies,to. Tall Free: daveFFiawridgetech.com P.O.Box 1179 Fat 1.425-335-3622 oscaronsite.com Lake Stevens,WA 98258 AY.McDonald c miden the imnNnN enthb"sunbb drung Nnat when WblishW.aem and on.arelleerity,1"Uh illwIhudNA ere-inlab'hang'wi[W n-fm Submitted by: MOM