Loading...
HomeMy WebLinkAboutBLD2013-00411 Final SFR - BLD Permit / Conditions - 5/28/2014 If" Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2013-00411 OWNER: DEANNE MONTGOMERY RECEIVED: 6/5/2013 CONTRACTOR: HILINE HOMES 253-840-1849 LICENSE: HILINH*983BD EXP.. 11/8/2013 ISSUED: 7/9/2013 SITEADDRESS: 1383 NE MUNSON BLVD BELFAIR EXPIRES: 1/9/2014 PARCEL NUMBER: 223097600130 LEGAL DESCRIPTION: TR 13 OF SURVEY 12/34 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR HILINE HOME 1768 ST RT 3 TO BELFAIR, L ON ST RT 300/ NORTH SHORE RD, R ON SAND HILL RD, L ON BEARCREEK DEWATTO RD, L ON TAHUYA BLACKSMITH RD, LO MUNSON BLVD T-O-/SITE R C C AD HARED om!\/y\n/n�\AIITL� �-�� /^✓J�[�i! 2—�� General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3/U Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: 2 Occ. Load: Building:1,768 Garage-Attached 528 Valuation: $ 212,349.72 Building Height: 28 Occ. Status: Primary Basement: COV PORCH 201 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: S 100.0 Ft. Shoreline: Ft. Water Body: Rear: N 60.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: E 200.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: W 100.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 3 Dryer Vent 1 Plan Check Fee GMM 6/5/2013 $ 1,057.26 S1201300000001 Lavatories 4 Exhaust Hood 1 Fire Warden Review GMM 6/5/2013 $ 73.00 S1201300000001 Bath Tubs 2 Ventilation Fan 4 EH Plan Review GMM 6/5/2013 $ 103.00 S1201300000001 Water Heaters 1 Water Adequacy Plan Revi GMM 6/5/2013 $ 103.00 S120130000000i Clothes Washer 1 Planning Review Fee GMM 6/5/2013 $ 205.00 S1201300000001 Kitchen Sink 1 Building State Fee LDK 7/2/2013 $4.50 S1201300000001 Dishwasher 1 Building Permit Fee LDK 7/2/2013 $ 1,626.55 S1201300000001 Hosebibs 2 Mechanical Permit Fee LDK 7/2/2013 $58.20 S1201300000001 Mechanical Base Fee LDK 7/2/2013 $28.50 S1201300000001 Plumbing Permit Fee LDK 7/2/2013 $ 119.30 S1201300000001 Plumbing Base Fee LDK 7/2/2013 $24.70 S1201300000001 Total $ 3,403.01 BLD2013-00411 Please refer to the following pages for conditions of this permit. Page 1 of 6 CASE NOTES FOR BLD2013-00411 CONDITIONS FOR BLD2013-00411 1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X n 2) All property lines shall be clearly identified at the time of foundation inspection. X 0if 3) All construction and demolition debris must be removed from the site after project completion. Pro pp� disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X SSG 11 11 4) Temporary erosion control measures must be implemented to prevent water quality d�e radation of adjacent waters or properties. Silt fencing must be installed and maintained until upland vegetation has become established. X � 5) Prior to final approval, all upland areas disturbed or newly, eated by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 6) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X v 7) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. X C)41-1 8) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800- 47-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X J,/7l 9) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X �'1 10) O /Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. Xs �/-Zj BLD2013-00411 Please refer to the following pages for conditions of this permit. Page 2 of 6 11)' The plan review check list and corrections are part of the approved plans and must remain thereto. i ::; 'ne responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be char:: or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the j "<iiOn of the project. Failure to comply and/or removal approved documents will result in failure of required building inspections. X 7? 12) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X�7� 13) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 .hour) will be charged and shall be collected by the Buildin Department prior to any further inspections being performed or approvals granted. X �G,JY 14) Washington State Energy Code Compliance has been approved as follows.- Heat Type: Electric or other than electric, Compliance Method: Prescriptive option III, Window (Max U-Factor):0.28, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-38, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credit from Table 9-1 shall be completed: 3A& 5A 3A- UP FLOOR INSULATION TO R-38 AND WINDOW U-FACTOR TO .28 5A- ELECTRIC HWT 93% 15) A permanent certificate, completed by the builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 503.10.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 0.00030 Specific Leakage Area (SLA) when tested with a blower door at a press of 50 Pascals (0.2 inch w.g.). Testing shall occur at any time after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation, and combustion appliances and sealing thereof. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference WSEC 105.4 Certificate and 502.4.5 Building Air Leakage Testing. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2009 Certificate" and are available in Y4 or'/2 sheets. The Mason County Permit Center will also have some available. X BLD2013-00411 Please refer to the following pages for conditions of this permit. Page 3 of 6 l 16r A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s) with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Refererlce� C 505. 17) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. x 18) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 19) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 10ft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No pundation drains within 30ft, down gradient of drainfield/reserve area. X 20) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X � 21) Carbon monoxide alarms, listed as complying with UL 2034 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. New and existingdwellings within which fuel-fired appliances are installed and new dwellings with an attached garage shall beequipped with carbon 9 Pp 9 9 9 mon i alarms. de a a ms. Carbon monoxide alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms. p P 9 Y X 22) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such pads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X ! � BLD2013-00411 Please refer to the following pages for conditions of this permit. Page 4 of 6 2M' Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged qrd)shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 24) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit rpvo ion. X ( /�7� T 25) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project X 1/ 26) Placemen�t of structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 27) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance,or regulation, must be reviewed and approved by Mason County prior to construction. X `� � 28) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Insppetpr shall be made prior to requesting additional inspections. X C(_/_/_17? 29) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mas ounty ordinances and building regulations. X 1'7 30) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit (old pv prevented action from being taken. No more than one extension may be granted. BLD2013-00411 Please refer to the following pages for conditions of this permit. Page 5 of 6 j Pressure treated wood ;manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connecters, and flashinc. Install metal connectors approved for contact with the new types of pressure treated material. X /�Yl Retaining walls needed tc support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of son County access to the above described property and structure for review and inspection. OWNER OR AGEN ' DATE: '? i BLD2013-00411 Please refer to the following pages for conditions of this permit. Page 6 of 6 ic o CONCRETE MECHANICAL MANUFACTURED HOME 0 NO Date 3j;11"( BY t61 z 1�1 Footings I Setbacks Gas Piping Ribbons 0 0 Inteno(Date By interior-Date By Date 0 Exte(w Date0 ByR Exterior-Date By Set-up M Point Load I Isolated Footings INSULATION Date Bv ;0 BG I SLAB INSULATION Date By Date ray FIRE DEPARTMENT Foundation Wallis Floors Date By M Date By Data > DECKS z FRAMING Walls Date By z - 3� Dal`' By PROPANETANKS M PLUMBING Vault By Date ay OTHER Groundwork Attic Date By _Date Type By Date By D.W.V DRYWALL Type- Date By Int.Brace Wall Date By -a Dale By (D FINAL INSPECTION a) Water Line Fire Separation Date By Date By Date By (D Pass or Request Inspect. 6 C) Type of Insp. Fail Date Date Done By Comments 7 en 3ft-ed U) E� - 0 /v 0 a nt 5131lq 0 Cn 0 If W tom, N77 Jq /q 3 Wf"Ile 0 h Permit# 13 ayf! MASON COUNTY BUILDING III 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location I 3X:5 A414s, This structure has been inspected by Mason County Building Department an the following VIOLATION of County Laws and Ordinances has been f nd: Items listed below must be corrected to gain compliance ft j ✓ > • � 1 sr "Cl You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing Ll please contact our office Make co rections, ite p will be checked on next inspection regarding possible structural damage incurred by recent "natural/man made" This is not a complete inspection C j-CAW disasters.This is NOTa Date f 1-Y Department s CORRECTION NOTICE. Inspector moor I ,or zT , florollf THI Rib, T A k Permit# 13 �( MASON COUNTY ' BUILDING III 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been f nd: Items listed below must be corrected to gain compliance TG II& -*�3 rrcce.e_ o2s UP Less L ioc•►L { r " S f iT cVciLl I 7A'rGS u - Piexacs SK s r► f I.ccQ — vt N�. W5. Oe,4 -r caw 114)-C --4 Spees -3t 101 e (L k -ry ic- % fArrtv.-1 4:Ogr Li c.,•r G -r-0 r-e U You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ® Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ❑ OK to damage incurred by recent VThis is not a complete ins ectio . "natural/man made" 'J com p P nj1`G.c.l J �'j, disasters.This is NOT a Date �I L1 Department CORRECTION NOTICE. Inspector bo 1(— ■ st 4 NnT PIUV ' THIS T'm-rqu i t 23,11 � 5iZ ' J PAM-*: / 2 2 30 4-16-�tS� I 11t.13 OF SugvEy t2/34 oo� ue�u. t.�u /s�tcr acE.x \ sog:044 rya- t I / for srr� e , / I N � � - 1 _ J,j► I I � ➢-cox �" mt,�,.�s�ovc H Q- I � I ALLSETBACK5XRE MEASURED SkT.IS��2 I � FROM T))E FURTHEST � PROJECTI OF THE BUILDING &0-316"C-St- -A O S.T. m-,nu I .� FJ•� I ;�" � ,_-• ,/ GSA 1 I � ? IOW �• 38'"+ TL1.tr APIROVED s,L/s.WACI� IA70 o MASOIy,C00 Ty DCD PLANN RRPROVED MCALTH DEFT CHA SIT£PL#A REQUIRED TO BE ON SITE NOV 3 0 1000 I - _ _ _ ES SUBJECT TO APPROVAL W `^ BY Date L ADR 13 81 n E vnu✓15cy C'A v w Mason County Map Output Page Page 1 of 1 Mason County Map r l m z m C N Z 5 pN 2 � � N v � z z m M C °1 S v n A A O I ,T i PLANNIN ' Z Z U r� RECEIVED JUN032013 ® 426 W. CEDAR ST (0 nsrt DISCLAIMER AND LIMITATION OF LIABILITY: The data used to make this map have been tested for accuracy,and every effort has been LEGEND made to ensure that these data are timely,accurate and reliable.However,Mason County snakes no guarantee or warranty to its accuracy as to labeling,dimensions,or placement or ,.r�� location of any map features contained herein.The boundaries depicted by these data are iwals r � Fo4oral Laws approximate,and are not necessarily accurate to surveying or engineering standards,and are intended for informational purposes only.Mason County does not assume any legal liability . Hightiays City of Shelton or responsibility arising from the use of this map in a manner not intended by Mason County. R vats g ;trfams ,,. C:osrity 84ura8ry 11 NdR In no event shall Mason County be liable for direct,indirect,incidental,consequential, L._i special,or tort damages of any kind,including,but not limited to,loss of anticipated profits Parc*ls Commissioner Districts or benefits arising from use of or reliance on the information contained herein S40ons Lakes ®2009-Mason County GIS ._I 100 W.Public Works Dr lJ Tvwnsh95 '� get Suvno d Maio(I_ Shelton,WA 98584 http://mapmason.co.mason.wa.us/servlet/com.esri.esrimap.Esrimap?ServiceName=amason... 5/3 0/2013 3W - 1-tL'-50yk LE) '--)ou 1(�n u z-/3y 1383 nfr ill vr�5an '1�1 vc1 O PLANNING RECEIVED N 3 3 .1013 W `'EDAR ST Name � " O MAIUA Parcel# BLD# L W Mason Count 3 2013 y JUN 0 Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14, Chapter 14.48 a stonnwater site plan is required whenever a building application is made for residential development, or redevelopment', with more than 2,000 square feet of impervious surface'. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X !� X = t. Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = Driveways X I _ X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Are is LESS THAN 2000 Square Feet, pl a read, acknowledge and sign below. Based Upon the information you have provi ed a Stormwater Site Plan IS NOT equired for this development activity. Owner/Builder/Agent Acknowledges that submissi urate in ay result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare tha e owner,owner's legal representative,or the contractor.I furthgr"acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- desci iibed property for review and inspection as may be required. Y. (!1 Owner/Agent/Contractor(circle one)Date: S / If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign the information provided on page 2 of 2. Pagel of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the Stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Permit Assistance Center SHELTON (360)427-9670 BELFAIR(360)275-4467 Elma (360)482-5269 FAX: (360)427-7798 WEB SITE: www.co.mason.wa.us P.O. Box 186, SHELTON 98584 2009 Washington State Energy Code (WSEC) Effective January 1, 2011. Ventilation & Indoor Quality Ventilation code provisions are now located in the 2009 International Residential Code (IRC), 2009 International Mechanical Code (IMC), & 2009 International Building Code The following information will be required for the WSEC and ventilation code plan review: 1. Complete the Washington State Energy Code/Ventilation code application located on the reverse side including information about the project, proposed compliance methods and proposed energy credit(s) listed in Table 9-1 attached to this form. All dwelling units are required to develop at least one credit from Table 9-1. 2. Include all windows, skylights, sliding glass doors, french doors and any other door with 50% glass or more on the window and door schedule. Use rough opening dimensions to calculate size. It is always helpful to list the u-factors of windows and doors, if known. If you do not know u-factors, the plan reviewer will assume that all window & door glazing will have the required u-factor of the compliance option. When using the area weighted average methods to comply with prescriptive-path include calculations with submittal documents. 3. Identify the location and fuel type of the heating system, water heater, location of exhaust fans (bathroom, laundry, kitchen, etc.) and R-factor of proposed insulation for walls, floors, ceilings, and slabs on the building plans. Indoor and outdoor lighting shall be high efficacy luminaires that comply with WSEC section 505. To verify compliance, provide lighting information on plans. 4. Questions? Call Mason County Community Development at (360) 427-9670 ext. 352. WSEC compliance information and code text is also available on the WSU-Energy Program website at: http://www.energy.wsu.edu/code/ Prescriptive Requirements ',' for Group R Occupancy Climate Zone 1, Table 6-1 Glazing Glazing U-factor Wall Waal Waal Slab 6 Area % Vaulted int ext DoorU- Above on Option of Floor Vertical overhead Factors Ceiling2 Ceiling3 Grade below Below Floors Grade grade Grade R-49 or R-21 R-21 1 13% .34 .50 .20 R-38 R-38 int' TB R-10 R-30 R-10 adv R-49 or R-21 R-21 II * 25% .32 .50 .20 R-38 R-38 int' TB R-10 R-30 R-10 adv R-49 or R-21 R-21 III Unlimited .30 .50 .20 R-38 R-38 int' TB R-10 R-30 R-10 adv *Reference Case/Call(360)427-9670 ext. 352 for footnote information. Log&solid timber wall with a min. avg.thickness of 3.5"are exempt from the above grade wall insulation requirements. MASON COUNTY DEPART MENT OF COMMUNITY DEVELOPME T ' D' NG WSEC/ Ventilation Code Compliance Application Owner: YYlI Parcel#:2Z30`17600/30 I Type of project: S;n IP Fumi�y Total Sq. Ft. 1 loor : 2" floor: Heated Basement: of heated area:: 1 -7(0$ 84y �gy Heating System Type: &Electric wall heater O Electric Central Furnace O LPG Furnace fl 202 O Heat Pump with electric furnace O Heat pump with gas furnace O Ductless Heat Pump O Boiler, specify fuel type: O Other: Specify: Glazing Compliance 11 Prescriptive Option see reverse side circle one: 1 II III Percentage: Method p Component Performance , Chapter 5— Calculation worksheets required �% Check one:: Other (Specify): Check one opWhole House Ventilation system µ Whole House Ventilation µ Other, Ventilation using exhaust fans&window or Integrated with a Forced Air describe: System wall fresh air vents (M1508.4) System (M1508.5) Referencing WSEC Section 901, "Additional Residential Energy Efficiency Requirements," all NkW residential units must develop 1 credit from Table 9-1. Identify and describe which option(s)will be used ENERGY to comply. If the table is not attached to this form you can access the table on our website at: http://www.co.mason.wa.us/forms/Community Dev/index. h . CREDITS Option: 777e4�cf'pitf "�r�/� ekiv� tJ= f2.�$ w1'nd�J 2-38 � Table 9-1 t't1�Ci Eft{ i�f�1� ( { MSv(U.�+�M 3ek + S.-I LVaEet {t0eO Ce�ec}�i�) chit). EF 0.'13,//ccu 20 Window & Door Schedule (If needed, attach an additional sheet) Total Manufacturer Room/location U-Factor Size Quantity Square Feet Windows: f I� .2 3 .2°k 5'�, Den-Di tit n4lLIv1 GD 6`X 6 10 i 4 /4 r( CYjN cX y t 9 80 Windows: Total Sq. ft. 220 Doors: ode E n Er .20 20 Doors: Total Sq. Ft 38 Total window and door area 2 g i 901 Additional Residential Energy Efficiency Requirements. Dwelling units permitted under this Code shall comply with all provisions of Chapter 5 of this Code and develop 1 credit from Table 9-1. EXCEPTION: Buildings complying using Chapter 4 Building Design by Systems Analysis shall meet this provision of this section by demonstrating that the proposed building energy use is 8 percent less than the target building energy use. Table 9-1,Energy Credits (Debits) OPTION DESCRIPTION CREDIT(S) 1 a HIGH EFFICIENCY HVAC EQUIPMENT 1: 1.0 Gas,propane or oil-fired furnace or boiler with minimum AFUE of 92%, or Air-source heat pump with minimum HSPF of 8.5. lb HIGH EFFICIENCY HVAC EQUIPMENT 2: 2.0 Closed-loop ground source heat pump;with a minimum COP of 3.3. 1 c HIGH EFFICIENCY HVAC EQUIPMENT 3: 1.0 DUCTLESS SPLIT SYSTEM HEAT PUMPS,ZONAL CONTROL: In home where the primary space heating system is zonal electric heating,a ductless heat pump system shall be installed and provide heating to at least one zone of the housing unit. 2 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM:' 1.0 All heating and cooling system components installed inside the conditioned space.All combustion equipment shall be direct vent or sealed combustion. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat is not permitted under this option. Direct combustion heating equipment with AFUE less than 80%is not permitted under this option. 3 a EFFICIENT BUILDING ENVELOPE 1: 0.5 Prescriptive compliance is based on Table 6-1,Option III with the following modifications: Window U=0.28 floor R-38,slab on grade R-10 full,below grade slab R-10 full. or Component performance compliance: Reduce the Target UA from Table 5-1 by 5%, as determined using EQUATION 1. ' 3b EFFICIENT BUILDING ENVELOPE 2: 1.0 Prescriptive compliance is based on Table 6-1,Option III with the following modifications: Window U=0.25 and wall R-21 plus R-4 and R-38 floor, slab on grade R-10 full,below grade slab R-10 full,and R-21 plus R-5 below grade basement walls. or Component performance compliance: Reduce the Target UA from Table 5.1 by 15%, as determined using EQUATION 1. ' 3c SUPER-EFFICIENT BUILDING ENVELOPE 3: 2.0 Prescriptive compliance is based on Table 6-1,Option III with the following modifications: Window U=0.22 and wall R-21 plus R-12 and R-38 floor, slab on grade R-10 full,below grade slab R-10 full and R-21 plus R-12 below grade basement walls and R-49 advanced ceiling and vault. or Component performance compliance: Reduce the Target UA from Table 5.1 by 30%,as determined using EQUATION 1. ' 4a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION: 0.5 Envelope leakage reduced to SLA of 0.00020 building envelope tightness shall be considered acceptable when tested air leakage is less than specific leakage area of 0.00020 when tested with a blower door at a pressure difference of 50 PA. Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing,electrical,ventilation,and combustion appliances. and All whole house ventilation requirements as determined by Section M1508 of the Washington State Residential Code shall be met with a heat recovery ventilation system in accordance with Section M1508.7 of that Code. 4b ADDITIONAL AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION: 1.0 Envelope leakage reduced to SLA of 0.00015 building envelope tightness shall be considered acceptable when tested air leakage is less than specific leakage area of 0.00015 when tested with a blower door at a pressure difference of 50 PA. Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing, electrical,ventilation,and combustion appliances. and All whole house ventilation requirements as determined by Section M1508 of the Washington State Residential Code shall be met with a heat recovery ventilation system in accordance with Section M1508.7 of that Code. Sa EFFICIENT WATER HEATING:' 0.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.62. or Electric Water Heater with a minimum EF of 0.93. and for both cases All showerhead and kitchen sink faucets installed in the house shall meet be rated at 1.75 GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less.2 5b HIGH EFFICIENCY WATER HEATING: 1.5 Water heating system shall include one of the following: Gas,propane or oil water heater with a minimum EF of 0.82. or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 Certified Solar Water Heating Systems. or Electric heat pump water heater with a minimum EF of 2.0. 6 SMALL DWELLING UNIT 1:' 1.0 Dwelling units less than 1500 square feet in floor area with less than 300 square feet of window door area. Additions to existing building that are less than 750 square feet of heated floor area. 7 LARGE DWELLING UNIT 1: -1.0 Dwelling units exceeding 5000 square feet of floor area shall be assessed a deduction for purposes of complying with Section 901 of this Code. 8 RENEWABLE ELECTRIC ENERGY: 0.5 For each 1200 kWh of electrical generation provided annually by on-site wind or solar equipment a 0.5 credit shall be allowed,up to 3 credits. Generation shall be calculated as follows: For solar electric systems,the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PVWATTs. Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors: The wind turbine power curve; average annual wind speed at the site; frequency distribution of the wind speed at the site and height of the tower. Footnotes: 1. Interior Duct Placement: Ducts included as Option 2 of Table 9-1 shall be placed wholly within the lieated envelope of the housing unit. The placement shall be inspected and certified to receive the credits associated with this option. Exceptions: Ducts complying with this section may have up to 5%of the total linear feet of ducts located in the exterior cavities or buffer spaces of the dwelling. If this exception is used the ducts will be tested to the following standards: Post-construction test: Leakage to outdoors shall be less than or equal to 1 CFM per 100 ft2 of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa)across the entire system,including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 2. Plumbing Fixtures Flow Ratings.Low flow plumbing fixtures(water closets and urinals)and fittings (faucets and showerheads)shall comply with the following requirements: (a)Residential bathroom lavatory sink faucets: Maximum flow rate-3.8 L/min(1.0 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1. (b)Residential kitchen faucets: Maximum flow rate- 6.6 L/min(1.75 gal/min)when tested in accordance with ASME Al 12.18.1/CSA B125.1. (c)Residential showerheads: Maximum flow rate- 6.6 L/min(1.75 gal/min)when tested in accordance with ASME A112.18.1/CSA B125.1. BUILDING PERMIT INFORMATION FORM - PLAN 1768 CONTRACTOR INFORMATION Creative Design Builders d.b.a.HiLine Homes RECEIVED 11306 62nd Ave. E Puyallup,WA 98373 .JUN 0 3 2013 i�gd 253-840-1849 HILINH*983BD/UBI#601-584-067 426 W. CEDAR ST expires: 11/08/2013 This will be a New Single Family Residence Type of work: NEW HOME CONSTRUCTION y� � 'a� ' HOME INFORMATION: D (sq.ft.) MAIN/1ST 884 #of stories 2 SECOND 884 Bedrooms 3 TOTAL 1768 Bathrooms 2.5 GARAGE(attached)528 Porch 198 ft2 CONSTRUCTION METHOD: WOOD FRAME HEATING SYSTEM: NOTE:BE SURE TO CHOOSE THE INFORMATION BELOW THAT COOROLATES WITH THE HEAT SYSTEM YOU HAVE ORDERED NOTE:HVAC MECHANICAL CONTRACTOR IS THE SUB INSTALLING HEATING SYSTEM 0-5ET/WALL MOUNT/ZONE HEATERS(STANDARD COMPONENTS) INSTALLER EVERGREEN STATE ELECTRIC CONTACT Justin Chamberlin LICENSE# EVERGRSE066JA PHONE (253)770.0656 EXPIRES 04/01/14 LOCATION Orting MANUF. Cadet BRAND Register Plus MODEL RM202; RM162 KW: 7/AMPS: 20 HEAT PUMP w/FURNACE w/HOT WATER HEATER INSTALLER CONTACT LICENSE# PHONE EXPIRES LOCATION MANUF. TRANE MODEL 4TEC3F31*4TWB4024 TONAGE 2 HSPF 8.5 KW 10 LRA/LRC 63 EFFICIENCY 100% SEER 14 NATURAL GAS FURNACE w/HOT WATER HEATER INSTALLER CONTACT LICENSE# PHONE EXPIRES LOCATION MANUF. TRANE MODEL BTU 60,000 EFFICIENCY 95% WATTS 997 PROPANE GAS FURNACE w/HOT WATER HEATER INSTALLER CONTACT LICENSE# PHONE EXPIRES LOCATION MANUF. TRANE MODEL BTU 60,000 EFFICIENCY 95% WATTS WATTS 997 PLUMBING CONTRACTOR INSTALLER K&M PLUMBING CONTACT Shawn Moody LICENSE# KMPLUS1995K5 PHONE (253)503.2676 EXPIRES 05/07/14 LOCATION University Place toilets 3 kitchen sinkf 1 bath sinks 4 water heater: 1 tubtshower 2 clothes wasf 1 showers 0 dishwasher 1 soaking tub 0 ENERGY COMPLIANCE INFORMATION:OPTION#3 UNLIMITED(per WSEC 2009) TOTAL Sq.Ft.of glazing(glass)divided by total sq.ft.of heated area=glazing% please see enclosed window schedule *swinging doors and skylights are not counted in this configuration because they meet all min.requirements Continuously operating Whole House Ventilation System using exhaust fans&window fresh air vents Whole House Ventilation System:IRC M1508.4 Discrete Spot&Whole House manufacturer Broan Model# QTRE110 CFM:110 Bathroom one-bulb heater I fans:Quantity(PER UNIT): manufacturer Broan Model# 162 CFM:70 it FIRE MAR$AAL GRADE INSPECTION BLD 26 l 3. 661A � ADDRESS: 1383 nE mUhc26(x- —&i yC� - 6E I fal x;L INSPECTOR: ")( DATE OF INSPECTION: l FIRE SPRINKLER REQUIRED? (circle) 0 YES IF fire sprinkler required, was notification letter mailed? DATE MAILED: DRIVEWAY ACCESS — / G Vol t,,,'G l y,.P_.2 d 00 need post at access of driveway with reflective address numbers Length: Width: Surface: Size of turn-around: YV Condition of shoulders: Vertical clearance: GRADE OF DRIVEWAY %, OF ROAD % ROAD ACCESS Length: Width: Surface: Condition of Shoulders: Vertical clearance: (� BURN PERMIT REQUIRED FOR LAND CLEARING FIRE. U LOT INSIDE UGA—NO OUTDOOR BURNING PERMITTED. LOT TOO SMALL FOR: BURN PERMITS 4 X 4 FIRES 2 X 3 FIRES PASSED ( ) FAILED ( ) ON HOLD ( ) RE S: ' N G � ,� -�►�-��� -�;� lam' �E s�2 RECEIVED JUN o 3 202 p—�l,ez i f't— 4�2 �Lvt S 5Svc 426 W. CEDAR ST 0-2— 3 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies 1 Deanne Montgomery project HLH#1768B 1383 NE Munson Blvd. Belfair,WA 98528 Parcel#223097600130 Heating System Size Ducts are located in unconditioned spate Conditioned Floor Area 1768 Equipment size over design load" 150i�0 Conditioned Building Volume 14144 Btu/hour output 26,311 Weather Statior Shelton . KWI 7.7 Component Performance,R-3 occupancies Code Target Values Proposed Design Values Area UA Area UA Vertical Glazing U= 0.300 265 79.6 220 63.8 Overhead Glazing U= 0.500 0 0.0 0 0.0 Doors U= 0.200 20 4.0 20 4.2 Flat/Vaulted Ceilings U= 0.027 884 23.9 884 17.7 Wall(above grade) U= 0.056 1617 90.5 1662 94.7 Floors U= 0.029 884 25.6 884 25:6 Slab on Grade F= 0.360 Below Grade 2'depth,wall U= 0.042 0 0.0 0 0.0 2'depth,slab F= 0.590 0 0.0 0 0.0 3.5'depth,wall U= 0.041 0 0.0 0 0.0 3.5'depth,slab F=0.640 0 0.0 0 0.0 7'depth,wall U= 0.037 1 01 1 01 0.0 7'depth,slab F= 0.570 1 01 0.0 1 0 0.0 Target UA Total 223.6 Proposed UA Total 206.1 Target Credits from Chpt.9 1.0 Proposed Credits from Chpt.9 1.0 If the Proposed UA s the Target UA, and the Proposed Credits From Chpt. 9 are>_ 1 than the home meets the 2009 WSEC. Check other code requirements Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 5/22/2014 1 of 6 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies Vedical Glazing Plan Componef Glazing Width Height ID Description Ref. U Qt. Feet "`h Feet "`h Area UA 3gl Wood/vinyl,Low-el 1/2"+argon v 131.00 10-613 0.290 1 2 5 10.0 2.9 3gl Wood/vinyl,Low-el 1/2"+argon w 131.00 10-613 0.290 3 5 5 75.0 21.8 3gl Wood/vinyl,Low-el 1/2"+argon w 10-613 0.290 1 6 6 10 41.0 11.9 3gl Wood/vinyl,Low-el 1/2"+argon V 10-6B : 0.290 1 4 3 6 14.0 4.1 3gl Wood/vinyl,Low-el 1/2"+argon V 10-613: 0.290 4 5 4 80.0 23.2 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0:0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 ::::0 0.000 1 0.0 0.0 1.00 ::::0 0.000 G.0 0.0 0.000 0.0 0.0 ::::::.1.00 0 0.000 O:fl 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 _ 0.0 0.0 0 0.000 0.0 0.0 0.000 GJ0 0.0 0 .. 0.000 0.0: 0.0 0 0.000 O.fl 0.0 0 0.000 0.0 0.0 0 0.000 O fl 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0:::: 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.0 0.0 0 0.000 0.10 0.0 0 0.000 0.0 0.0 0 1 0.000 0.0 0.0 Copyright 2010.WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 5/22/2014 2 of 6 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies w 0 0.000 0.0 0.0 w 0 0.000 0.0 0.0 w 1.00 0 0.000 0.0 0.0 w 1.00 0 0.000 0.0 0.0 w 1.00 0 0.000 0.0 0.0 w 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 Sum of Area and UAI 220.01 63.8 Glazing Area Weighted U 1 .290 Exterior Doors Plan Component Door Width Height ID Description Ref. U Qt. Feet Inch Feet Inch Area UA 1 Exempt Door if less than 24 SF #N/A NA 0.0 ISteelWE 1gl 6%22x8' 21.00 10-6C 0.210 1 3 6 8 20.0 4.2 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 1.00 0 0.000 0.0 0.0 :: 1.00 0 0.000 0.0 0.0 :A.00 0 0.000 0.0 0.0 :1.00 0 0.000 0.0 0.0 : 1.00 0 0.000 1 0.0 0.0 1.1.001 0 1 0.000 1 0.0 0.0 If exempt door is selected, must be<_24 SF. Sum of Area and UA 20.01 4.2 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 5/22/2014 3 of 6 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies Overhead Glazing: Plan Component Glazing Width Height ID Description Ref. U Qt. Feet Feet Feet Inch Area UA 1.00 0 0.000 0.0 0.0 V 1.00 0 0.000 0.0 0.0 V 1.00 0 0.000 0.0 0.0 V ':1.00 0 0.000 0.0 0.0 ::1.00 0 0.000 1 1 0.01 0.0 Ij .1.00 0 0.000 0.01 0.0 :1.00 0 I 0.000 0.01 0.0 . ... . . . .. . ........ Sum rea and. . . .. 1. 1.c . ,FlatNaulted Ceilin9 s .......... . . ... ..... ............. .. Plan Component Attic ID Description Ref. U >.. :.:: :::.:•:::> >. Area UA R49 blown Scissor 5:12 ADV baffled 25.00 10-7 0.020 884.0 17.7 1.00 0 0.000 0.0 . ............... ....... 1.00 0 0.000 0.0 1.00 0 0.000 0.0 ...... . Sum of Area and UA 884.0 17:7 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 5/22/2014 4 of 6 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies Walls(Above Grade) Plan Component Wall ID Description Ref. U Net Area UA R21 cavity+RO foam STD 2X6W Lap w 236.00 10-5 0.057 1662.0 94.7 V 1.00 0 0.000 0.0 V 1.00 0 0.000 0.0 W 1.00 0 0.000 0.0 1W 1.00 0 0.000 0.0 1W 1.00 0 0.000 0.0 1W 1.00 0 0.000 0.0 V 1.00 0 0.000 0.0 1.00 0 0.000 0.0 V 1.00 0 0.000 0.0 V 1.00 0_ 0.000 0.0 1.00 0 0.000 0.0 1.00 0 0.000 0.0 Sum of Net Wall Area and LIAI 1662.0 9:4 7 Floor(over crawl or exterior) Plan Component Floor ID Description Ref. U Area UA R30 vented Joist 16oc 12.00 10-3 0.029 884.0 25.6 1.00 0 0.000 0.0 1.00 0 0.000 0.0 1.00 0 0.000 0.0 Sum of Area and UAI 884.01 25.6 Slab on Grade(less than 2 feet below grade) Plan Component Slab Slab ID Description Ref. F Length UA V 1.00 0 0.000 0.0 W 1.00 0 0.000 0.0 1W 1.00 0 0.000 0.0 1W 1.00 0 0.000 0.0 Sum of Area and UAI 0.01 0.0 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 5/22/2014 5 of 6 Washington State Energy Code: Component Performance Worksheet,Type R-3 Occupancies Below Grade Walls and Slabs: 2 foot depth Plan Component Wall Wall Wall Slab Slab Slab ID Description Ref. U Area UA F Length UA 0 0.000 0.0 0.000 0.0 1W 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UAI 0.01 1 0.0 0.0 Below Grade Walls and Slabs: 3.5 foot depth Plan Component Wall Wall Wall Slab Slab Slab ID Description Ref. U Area UA F Length UA V 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 V 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 Sum of Area,Length and UAI 0.01 0.01 0.01 0.0 Below Grade Walls and Slabs:7 foot depth Plan Component Wall Wall Wall Slab Slab Slab ID Description Ref. U Area UA F Length UA 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 0 0.000 0.0 0.000 0.0 Sum of Area, Length and UAI 0.01 1 0-01 0.0 Chapter 9 Options Total of 1 Credit Required Opt, Opt. Description 1 a IHigh Efficiency HVAC Equipment 1 ❑ 1b High Efficiency HVAC Equipment ❑ 1c Hi h Efficiency HVAC Equipment 3 ❑ 2 High Efficiency HVAC Distribution System ❑ 3a Efficient Building Envelope 1 F 0.5 3b Efficient Building Envelope 2 ❑ 3c Super-Efficient Building Envelope 3 ❑ 4a Air Leakage Control and Efficient Ventilation ❑ 4b Additional Air Leakage Control and Efficient Ventilation ❑ 5a Efficient Water Heating 0.5 5b High Effieciency Water Heating ❑ 6 Small Dwelling Unit ❑ 7 Large Dwelling Unit ❑ 8 Renewable Electric Energy ❑ kW Total Credits 1.00 Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 5/22/2014 6 of 6 ' Specification Data Panasonic Panasonic Ventilation Fan �js c� DENT/LAT/ON FAN ����� Description EftM Ventilating fan shall be Low Noise ceiling mount type rated for continuous run. Fan shall be ENERGY STAR rated and certified by the Home Ventilating Institute (HVI). Evaluated by Underwriters Laboratories and conform to both FV-08 VKM3 UL and cUI,safety standards. (0-80 CFM) Motor/Blower: • Enclosed DC brushless motor technology, currently more energy ro, efficient than the minimum ENERGY STAR requirements, rated for s continuous run. y'C • Power Rating shall be 120 volts and 60 Hz. h • Fan shall be UL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thermal cut-off fuse control. • Removable with permanently lubricated plug-in motor. Housing: Rust proof paint,galvanized steel body. • Detachable 4"diameter duct adapter. 410?3 • Built-in backdraft damper. ''?•� • Expandable extension bracket up to 24". Double hanger bar system allowing for ideal positioning. Grille: ,3 Attractive design using PP material. Attaches directly to housing with torsion springs. Warranty: The factory warranty shall be a minimum of 6 years limited warranty on 'O• the motor and 3 year limited warranty on parts. Typical Specifications: 0.80 --- --- Ventilating fan shall be of the ceiling mount, ENERGY STAR rated type,with m �� variable speed of 0-80 CFM and no more than 0.3 sone as certified by the Home 0.70 - -20 Fe Ventilating Institute(HVI) at 0.1 static pressure in inches water gauge. Power ---"'°Fwt consumption shall be no greater than 7.0 watts and ENERGY STAR rated with -80 Fs°` efficiencyrating of no less than 12.1 CFM/watt.The motor shall be enclosed a 0.60 1 80 FW with brushless DC motor engineered to run continuously.Power rating shall be ;, --"100 F°°` 120v/60Hz.Duct diameter shall be no less than 4". Fan shall be UL and cUL 0.50 -••70 CFM listed for tub/shower enclosure when used with GFCI branch circuit wiring. 1 --eo CFM Fan shall be California Title 24 compliant. 0.40 -50 CFM ....40 CFM DC Motor Technology: 1 -••30 CFM • Allows the fan to run continuously at a pre-set lower level(0,30-70 CFM). 0.30 The fan then elevates to a maximum level of operation (80 CFM) when j motion sensor is activated. °'20 • When fan faces static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised,which allows the fan to 0.10 perform as rated. _' 4, • Automatically activates whenever someone enters or leaves the room. 0•00 0 20 40 60 80 100 A MW CFM) Whis erGreen FV-08VKM3 Static Pressure in inches w. . 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume CFM 80 79 70 75 60 59 50 54 40 39 30 32 Noise (sones) <0.3 0.4 <0.3 0.4 <0.3 0.3 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 Power Consumption watts 7.0 11.0 5.4 10.1 5.0 8.7 4.3 7.5 3.7 6.6 3.2 5.8 Enerav Efficiency CFM/Watt 12.1 7.6 13.3 7.7 13.6 7.7 12.4 7.7 12.8 7.1 11.4 6.7 Speed RPM 832 1 11301 791 1 11251 773 i 11061 749 1 1101 1 740 1093 745 1087 Current (amps) 0.02 1 0.01 0.03 0.01 0.05 1 0.01 0.05 1 0.02 0.05 1 0.03 1 0.06 0.04 Power Rating V/Hz) 120/60 120/60 120/60 120/60 120/60 120/60 As of 1/11 1E I. �� For Complete Installation Instructions Visit www.panasonic.com/building C c UL US H€aVI Model Quantity Comments Project. Location: Architect: Engineer. Contractor: Submitted by: Date: Panasonic Home& Environment I One Panasonir.Wav i Seraucus- NJ 07094 i 866-292-7292 1 www-nana.-onir.com/buildina Learn about Panasonic's FV 08VKM3 http://www2.panasonic.com/webapp/wcs/stores/servlet/ModelDetail... Panasonic fdoas for life ¢nneun+ar intlt51v101 >WhisperGreen>FV-08VKM3 FV-08V KM3 Catalog WhisperGreen 80 CFM Ceiling Mounted Ventilation Fan with DC 4SPrint this page Motor,Variable Speed Controls, and Motion Sensor �i view/compare all models See Dealer for Price >%'" Find Dealer FQLP71e features ""�� ......................._._.._..._—__..............._.. ..... ._......__ .____._.... .. .._...._.._.... ................._.... Motor Type DC Type of Motor Bearing Ball ....._...._....................._...._....__..............................._.__.................._........... _.._...... .... ....... ......... ...... _........_......................._................_......................._.__......_._..........._...._.. Thermal Fuse Protection Yes Blower Wheel Type Sirocco ........................-......................................................................................._._. .._._.._.._..._—_._........__......_.....___._................... __......_..."'--"""'" Mounting Opening(inches 101/2. sq.) Grille Size(inches sq.) 13" ........................___._._......__....._..._.__._.___._....._... ....--- __--- _...._..__......._...______.__............... --- _._......_.._._--------- _. SmartAction-Motion Yes Sensor High/Low Delay rimer Yes CustomVentm Variable Yes Speed Control SmartFlow—Optimum CFM Yes Technology ......_._...._._......_...._.....................____..._._.__._..._.........._.__..._._.__...._._.............___.....-___.__-...._._....._._....-----............__...._._.._....._......... Washington State VIAQ Yes Code California Title 24 Yes Compliant .................................._........._........................_.._._.._............._._..—_..._._............_....__._...__........._............._............._.__..._............ __ Mfg in ISO 9001 Certified Yes Facility Energy Star Qualified Yes ..................._..........._..._.._.................._---.... ...._._.—._.__.__..____._...—..........._.__........................................_............................... Duct Diameter(inches) 4"or 6" Gross Weight(lbs.) 12.1 .............................................................................................._.............._.._....._...__._._____._._.._—_.___........_....................................._..—............ UL tub/Shower Enclosure Yes Dimensions(H x Wx D) 11.0"x 14.25"x 17.0" ................... ...................................._._.--- —" ---._._._..._.......---.._...__...__.......................---.._.__ Weight 12.5 Its F.evp,apciRcraonr 8 Atie vuE�tb clwpe MVwre roEw. cnr:v�.r�ca��rxu�m.•s:,ca�wrrno a smrrt M:. oc ra.m�a,ro-::::::.c. 1 of 1 5/22/2014 8:50 AM Leam about Panasonic's FV-08VKM3 http://www2.panasonic.com/webapp/wcs/stores/servlet/ModelDetail... Panasonic* x=s for life >WhisoeKireen>FV-08VKM3 - FV-08V KM3 Catalog WhisperGreen 80 CFM Ceiling Mounted Ventilation Fan with DC ^an SPrint Shis page Motor,Variable Speed Controls, and Motion Sensor View/comoare all models See Dealer for Price / •find Dealer For Price `wF, ovemaw Constant CFM Performance This WhisperGreen®model features built-in intelligence called SmartFlow Optimum CFM Technology.This unique"electronic-brain"lets the fan do what was once thought to be impossible:perform at a constant CFM regardless of elbows and other factors that might hinder performance.Basically,when a WhisperGreen®fan faces static pressure,Its speed Is automatically Increased to ensure that the desired CFM Is actually achieved.This allows the fan to perform as rated and makes for easier sizing because the specifiers no longer has to worry as much about compromising the fan's performance. Quiet Motor Means Quiet Operation Panasonic is the first ventilation fan manufacturer to Incorporate a DC motor in residential mechanical ventilation fans.The WhisperGreen®series Incorporates an enclosed DC motor designed for extremely quiet,energy-efficient operation.The permanently lubricated motor is also engineered for trouble-free,continuous run for several years. SmartAction®Motion Sensor The SmartAction motion sensor automatically activates whenever someone enters or leaves the room. Variable Speed Control This fan is equipped with a CustomVent Variable Speed Control.This allows the fan to run continuously at a pre-set lower level of 0,30-70 CFM that can then be elevated to a maximum of 80 CFM when the switch Is turned on.A High/Low delay timer(adjustable up to 60 minutes),will then return the fan to the minimum CFM level after a period of time set by the user. Delay Timer A High/Low delay timer(adjustable from 30 seconds- 60 minutes),will then return the fan to the minimum CFM level after a period of time set by the user. ENERGY STAR®-Qualified for Energy Savings ENERGY STAR®-qualified products feature super-quiet operation and high CFM-to-Watt efficiency.The ENERGY STAR program was created to help consumers Identify products that can save them money and protect the environment by saving energy.As an ENERGY STAR partner,all of our fans are ENERGY STAR-qualifed and labeled accordingly. User-Friendly Installation Detachable 4 or 6 inch adaptors,firmly secured duct ends,adjustable mounting brackets(up to 26"), fan/motor units that detach easily from the housing and uncomplicated wiring all lend themselves to user-friendly installation.This model also features a double-hanger bar system for ideal positioning. Tired of Cold Air Coming Through Your Ventilation Fan? 1 of 2 5/22/2014 8:51 A� Learn about Panasonic's FV 08VKM3 http://www2.panasonic.com/webapp/wcs/stores/servIeVModelDetail... This Panasonic fan has a built-in damper to prevent backdraft,which helps to prevent outside air from coming through the fan.Also,thanks to our efficient, cool running motors,it does not create excessive heat. Loose fill or batt Insulation can be placed directly over the fan housing to prevent heat from escaping. FW.,O*C*** 8 pkft 0ulMtl b ohn IAOW roNw. es,'a: 2 of 2 5/22/2014 8:51 A� MASON COUNTY PERMIT NO.'?)IU2D��' B" I LD I N G BUILDING PERMIT APPLICATION 426 W. Cedar • P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670• Belfair (360) 275-4467 • Elma (360) 482-5269 AW On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner .-:,: "_ 1-6c,'i L,ot tzr Company Name N,I-fle No-me s Mailing Address 1 E r Mailing Address i 13C E•2'2 A,,- F City =1 �- State -�'N Zip Code 225211 City P.tikil�� State ✓A Zip Code `1837 3 Phone S40-7 "�-81k 3 Other Ph. 6-0 2 0" -07-Z-3 Phone 25S-'3y0 I iLj t Other Ph. Lien/Title Holder KG Mc 'A a Contractor Reg. # 0 I Lf ur tci 8 3'D Exp. E mail address 0- r;1 r, vto E,60 r .Y E Mail Address o 1--"es Drivers Lic.#t'-1o: tT_1L DOB C-F {; 4�x Drivers Lic. # DOB SEPTIC/WAT M INFORMATION - Conne Existing Septic onnect to ter System Name of Water em II Water System er System PARCEL INFORMATION - 12 Digit Parcel No. 2)3orf.7(c)v 130 Fire District Legal Description Site Address (Please include street name, street number and city) '033 NE M�,�sv°r t3'ty a. B� 14, � Directions to site Will timber be cut and sold in parcel preparation? Yes/No Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs ) 15% Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New x Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building S'loc 4--:W' ,= Describe Work LL&-- b-,1+ I�c,vw en c�'0c.rc#e 4-�n�wn',-Yl No. of Bedrooms 3 No. of Bathrooms -'I L Square Footage- 1 st Floor, 2'zg 2nd Floor '33-f 3rd Floor Basement Deck Covered Deck_ Other Sq. ft: Garage Attached tr Detached Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information providers sits ccurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF)CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. J` . \J X D �_.:_•:.�'-�az,.,�_ Gr _ '�-;� ate• Owner/Owners Re resent ro /Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted b A 0 Date 5_36 2W 1 DEPARTMENTAL REVIEW APPROVED DENIED P NOTES Building Department 70&3 L,p Planning Department Environmental Health Department OA +0 Public Works Department Fire Marshal FEES Building Permit Fee Site Ins ection Plan Review Fee EH Review Fee Plumbing & Base Fee Planninq Review Fee Mechanical & Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES MASON COUNTY PERMIT NO.'b Id 2013 - 010q l I L- •-'IPLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670• Belfair(360)275-4467- Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner D'ea ?,.7 r_ /o/0.,i `�r r�7 e� 4 _ Company Name J-I,L+ne HCyM A Mailing Address Mailing Address 113[`r City-/' '• State Zip Code 2 93z 4 City P- 1 State "'A Zip Code `f S-' / 3 Phone360.32; Other Ph. _?(..o a j-0'73 Phone �"� � �° i�"`' Other Ph. Lien/Title Holder WL!E:ii2%2 bt;c, K0C+&Cx A jz­ Contractor Reg. # IL L i ti H `7§3 F 8D Exp.-I- 0 L i Email address rr��/-art�c�t= ya.7?ej . C_c,"-, E Mail Address ��� 015 C � i A �� yes �•^^ Drivers Lic.#t'fGr-!T-G P,L !mil:` DOB C S .?l Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. 2�3C''7 7C 00 i 3() Fire District Legal Description Site Address (Please include street name, street number and city) Directions to site Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New 'x Add Alt Repair Other Use of Building Location of Fixtures/Units - 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNIT Tyne of Fixture No. of Fixtures Fees Fuel Type:Electric V LPG_Natural Gas_Heat Pump_ Toilets 3 Type of Unit No. of Units Fees Bathroom Sink - � - I^ Furnace Bath Tubs G �--� rry Heatpumps Showers — Spot Vent Fan Li Water Heater Propane Tank Clothes Washer ' Gas Outlets Kithen Sinks r Wood/Gas/Pellet Stove Dishwasher I Kitchen Exhaust Hood t Hosebibs 2 Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required fpr�any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permi i6n from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provi d is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PR F OF.•CONTINUA F ORK16 BY MEANS OF A PROGRESS INSPECTION. SC Date: )` ID Owner/Owners Representative Ontractor m icate which one) FOR OFFICIAL USE BEYOLNP,THP POINT Accepted b • Panning Pd Ck# Date 30 12C)i3l3ld Pd Receipt No. DEPARTM TAL REVIEW APPROVED DENIED NOTES Building Department 1 Occ Group-Type Constr. 7 L �3 ► vTIT 7171 Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee Other Violation Fee TOTAL FEES