HomeMy WebLinkAboutBLD2024-01128 BAV2024-00008 SFR - BLD Application - 9/16/2024 Permit No: I
MASON COUNTY KtULIVLD
COMMUNITY DEVELOPMENT SEP 16 2024
Permit Assistance Center,Building,Planning
BUILDING PERMIT APPLICATION L6f5 1ffAlder Street
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
t
NAME:MTT HOMES NAME:MTT CONSTRUCTION
MAILING ADDRESS:16000 Christensen Rd Ste 150 MAILING ADDRESS:16000 Christensen Rd Ste 150
Q CITY:rutcwly STATE:WA ZIP:salsa CITY:TuKwrLA STATE:WA ZIP:9e18e
(�J PHONE#1:253-508-2156 PHONE:253-508-2156 CELL:
PHONE#2: EMAIL:
EMAIL:KASH@MTTHOLDINGS.COM L&I REG#MTTCOCL866KT EXP. g / 3 / 2ffCz
PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER❑+ z
NAME NORTHWEST PERMIT INC.-CHLOEMILLHOLLIN EMAIL CHLOE@NWPERMIT.COM
MAILING ADDRESS 1026 SW 151ST ST CITY BURIEN STATE WA ZIP 98166
PHONE 208fi01-7043 CELL
PARCEL INFORMATION: J
PARCEL NUMBER(12 Digit Number) 1222o-50-stoos ZONING URBAN GROWTH AREA
LEGAL DESCRIPTION(Abbreviated) ALLYN LOT:5 BLK:61 S 42/242 FIRE DISTRICT
SITE ADDRESS 61 E COMPASS LN CITY ALLYN
DIRECTIONS TO SITE ADDRESS
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO❑+ SNOW LOAD:__psf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW 0 ADDITION❑ ALTERATION❑ REPAIR❑ OTHER
USE OF STRUCTURE(Residence,Gamge,Commercial Bldg,Etc)RESIDENTIAL
IS USE: PRIMARY❑r SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2
HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Part[s]ofBldg)I] NO[I
DESCRIBE WORK NEW SFR
SOUARE FOOTAGE:(proposed)
I ST FLOOR 4wr tG(;sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK 195 sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE400 sq.ft. Attached I] Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER NEW 0 EXISTING❑
PLUMBING IN STRUCTURE? YES El NO❑ I,fyes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES 0 NO[] EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS 3 TOTAL BEDROOMS 3
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this penult and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This pennitlapplication becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
X
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT J )2—S
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY COMMUNITY SERVICES Permit No:5 le-1 Z0; 11:A b
PERMIT ASSISTANCE CENTER:
•BUILDING •PLANNING •FIRE MARSHAL
615 W.Alder St-Shelton,WA 98584
www.co.mason.wa.us
Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7796
Phone Belfair:(360)275-4467• Phone Elma:(360)482-5269 L�;
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:MTT HOMES NAME:MTT CONSTRUCTION
MAILING ADDRESS:16000 Christensen Rd Ste 150 MAILING ADDRESS:16000 Christensen Rd Ste 150
CITY:TUKWILA STATE:WA ZIP:98188 CITY:TUKWILA STATE:wA ZIP:98188
1 st PHONE:253-508-2156 PHONE:253-508-2156 CELL:
2nd PHONE: EMAIL :
EMAIL: L&I REG#MTTCOCL866KT EXP. 6 /3 /2026
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number):12220-50-61005 Zoning:URBAN GROWTH AREA
LEGAL DESCRIPTION(Abbreviated):ALLYN LOT:5 BLK:61 S 42/242
SITE ADDRESS:-B1 EAST COMPASS LANE CITY:ALLYN
DIRECTIONS TO SITE ADDRESS:
(SEE ADDRESSING FORM DIRECTIONS)
TYPE OF JOB:
NEW ✓0 ADD ALT[=REPAIR=OTHER=USE OF BUILDING RESIDENTIAL
LOCATION OF FIXTURES/UNITS—1ST FLOOR=2ND FLOOR=BASEMENT=GARAGE=OTHERO
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:ElectricOLPGCNatural GasODuctless0
Toilets 2 Type of Unit No.of Units Fees
Bathroom Sink 3 Furnace 1
Bath Tubs 2 Heat Pump 1
Showers 2 Spot Vent Fan 3
Water Heater 1 Propane Tank
Clothes Washer 1 Gas Outlets 1
Kitchen Sinks 1 Wood/Gas/Pellet Stove
Dishwasher 1 Kitchen Exhaust Hood 1
Hose bibs 2 Dryer Vent 1
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null 8 void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE APPLICATION.
X
Signature of Owner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT STZ
PLANNING DEPARTMENT
FIRE MARSHAL
Rev.1/27/2016 JBN
A ,
LOT STATISTICS LEGEND NOTM ALLYN 10
1. BUILDING IS OFFSET 6.00'SOUTHEAST
LOT AREA 4,800 SF —x—B— sti FdLE AND IS AUGNED PARALLEL.TO THE LOT 5
PROP.FOOTPRINT: 1.872 SF TAHsIAICIIDN NORTHWEST PROPERTY LANE TAX PARCEL NUMBER: 122205061005
COVD PORCH/PATIO: 195 SF DURANCE Z SEE ARCH.PLANS FOR ROOF ADDRESS:61 E COMPASS LN i
TOTAL BUILDING COVERAGE: Z067 SF iW50. OVERHANG DIMENSIONS MTf(HOE N WEST
`2
DRIVEWAY/CONC.: 496 SF FlOO(PIE PLAN ICED-1479 t._
TOTAL ROOF AREA Z3%SF _—sue cTtArmc scACE \/`�1
g7Eit
TOTAL IMPERVIOUS AREA! Z852 SF
TOTAL IMPERVIOUS: 591 TON 24.0D '"•v R
— 20.1. 78.00' ' V 6
CIOTAL IM'FRNOUS ILEA FOR WRS IDT M1EEQ ____��—y
ALL ROOF.UNCONFm wROI,PAWQ WAIFA B
DRnEwIr,Nn soewNx uEAa
qq WATER SERVICE
573.00'OLE 120.Do,_
30.00' 130.00'
SEE RESIOFNTAL CONSTRUCTION ENTRANCE .'.�
DETAIL NOTE FUTURE CONCRETE DRIVE TO FE SILT FENCE y I I 3
INSTALLED OVER THE CONSTRUCTION ENTRANCE. LOT a $ 8 j Q a
AT FLOW LIE i I 3 M
lion I 8 3
_
/ C o
Lu. •/ �- F.-O N
SMc q toW� I I — _ 57J'00'00'E 120.W J =J W
INSTALL CB PROTECTION(TYP)
ADS o-Wb p PROPOSED STRUCTURE —— OL 6'SSCO Q C = >
.t'~? Jq V ROOF DRNN LANE(TAP) 01111-54AS C„)
W SPLASH 9LOG((TAP.)SEE ROOF DOWNSPOUT CIEARtlO LYTS EE59.9' H00g =
DETAIL I ON THIS SHEET _ o
ROOF DOINSW BDOES W TD N
LY WR NO S.F.OF NOV. _ t
r WEL 11100E55 ��.
OF 3/4'TO I /!CRUM uMW1 -_ -
PRWUE RAL WIH OF KKZ/MIM NFA ILTs -
STABAUZO CMTAUCTM ENTRANCE
GEDIT.TILE FABRIC T NIIL F4BRIc -
2'N2•VDDO POST(TYP) 9T'T2.L. TRENCH ��.�..ppe� I/.A1�.IxYy �
DR EDUIVALENT dt RETTER AND 114E MESH TO AT LEAST ENTT`E MVIp BEYt.VPR BLOCK
!6 R 114=.O.C. / BOTTOM TRENCH
{'-6.0 0.5 BEFORE PLACING NAVEL -2'zz'=�'VOOD POST OR _� D.RIprGi GAD
DERBUNO SWFACE T EQUIVALENT W BETTER Ch-A NDA
12'DEEP,B'VIDE TRENCH EnER9ONT CxBvk.O� CAD
FiL1E0 VITN 3/I•TO 11R' skm
O' VASHn GRAVE].Qi VEGETAL aDO( DCb• OB/t2 3l
T OEEP,B'VIDE D-- 2.S
T14'T FILED VITA I. Cv fLOV ERI3 D JRO Na: 211R3
VA9ED GRAVEL P VE T � 2.5' 1 R0.1ND SURFACE rtAlUR6 wITNED M 1115 DRAVK ex.vt NO.-
/Byr MD12MG HR MOT IBCkD TB ROM .
10TT7l1 ETEIEMB IF_/ �_ ROR-Q-CAM,F/3LO11,PNIOL UE$
ILc FARIL N.T.S. SPLASH BLOCK DETAIL BLOCK DETAIL ff�q nnAxaz � 1
x1s wMNG ROE DDE. max wNO
__ Rrmlms aR IIyI.IRFD FR(xl rBmclD
uutExGs vmlm ar Drum RI t sn..t.
�.OZo7� -o►IZ$
09/23/2024
APPROVED
MASON COUNTY DCD PLANNING
LOT STATISTICS LEGEND NDTEs: ALLYN 10 SO-0RLIEDY,AICP
LOT AREA
_ 1. BUILDING IS OFFSET 6,00' SOUTHEAST
4,80o SF SILT FENCE AND IS ALIGNED PARALLEL TO THE LOT 5 Digitally V °
PROP. FOOTPRINT: 11872 SF NORTHWEST PROPERTY LINE.
7`j», CONSTRUCTION TAX PARCEL NUMBER; 122205061005 scow Rug ty signed
COVD PORCH/PATIO: 195 SF ENTRANCE 2, SEE ARCH, PANS FOR ROOF ADDRESS: 61 E COMPASS LN R Sc tt
TOTAL BUILDING COVERAGE 2,W7 SF DYERHANG DII ENSIONS, NTT HOMES NORTHWEST
TOPSOIL Front yard-15 feet.10 feet on cul-de-sacs as long as the (206) 466-0991 All setbacks are measured from the furthest RE
DRIVEWAY CONC.: 496 SF — — STOCKPILE average setback is 15 feet. PLAN ED-1479
/ NC projection of the building. �
Side yard-5 feet,or less with review and approval of an GRAPHIC ,9CALo \/\
TOTAL ROOF AREA: Z356 SF _5� administrative building variance j
_— SEWER Streetside yard-8 feet BAV2024 00008 4'MIN SUBJECT TO BLD CODES a
TOTAL IMPERVIOUS AREA': 2,852 SF Rear yard-10 feet.In cases when the rear yard abuts a (,
N MET
TOTAL IMPERVIOUS: 597E —_ STORM right-of-way,the primary structure setback shall be 20 feet. I Iron-90 It. NA
20.00' 76,00' 24.00' `, R
-TOTAL IftIPERylWS AREA FIX(THIS LOT INCLUDES; _ v
ALL ROOF,UNCOVERED PORCH.PADO, WATER a Ra
DRIVE*'AY,AND 9DE1yALK AREAS,
$ WATER SERKE
All required setbacks shall be measured from the nearest m
property line,except that front yard setbacks shall be measured �yI _� 573'00'00'E 120.00'
from the property line or the edge of an access easement. 1D'!p' 10•�1 — — — — } — —
00' �' 1 30 00' a
- ------- ---- -----------
SEE RESIDENTIAL CONSTRUCTION ENTRANCE I I �;��� 5 BSBL —
DETAIL. NOTE: FUTURE CONCRETE DRIVE TO BE '�.r ^ ���SILT FENCE
INSTALLED OVER THE CONSTRUCTION ENTRANCE. F = Q P CD Z
AT FLOWU E I cam' LOT 5 _�$ o Q c, I I ~
' •ne,t"` °' „ FF=171.2 I 4°d,, n< I W
Public sewer and water ZI o- 4ao0' I o p 3
pp
9
I I I PORCH
Q I _ RD
4�y,��` ° LI I 57300'00"E 120.00' �— INSTALL CO PROTECTION (TYP) J = _J U 3
6� pp OP PROPOSED STRUCTUR 8 EX 6" SSCO
� ttp /s�V,�0 V ROOF DRAIN LINE ) � RIM=64,43' Q V = >
C °az Nfo W SPLASH BLOCK (TYR) SEE ROOF DOWNSPOUT CLEARING LIMITS IE=59.9' HOUSE �
/N. DETAIL 1 ON THIS SHEET tic 0 o
ROOF DO'ANSPOUT SERYES UP TO
26 ON.RAO EH APPROVED Too s.F.OF ROOF. � >�
Rhonda Thompson 1V14/2024 _' 5
6'IIIN.THICKNESS ,\,>y`�. ., � N
IX 3p'TO FULL
MO CRUSHED N GRAVEL BAV2024-00008-4'MIN SUBJECT TO BLD CODES
PROVIDE FULL MOTH OF iNCRE55/EGRESS AREA _
All setbacks are measured from the furthest
STABILIZED CONSTRUCTION ENTRANCE projection of the building.
2'x2' W13M POST (TM (CO7EXTILE FABRIC TEx FILE FABRIC _ _^�,� o u
-AND MIRE MESH VRPP AROUND TRENCH SPLASH
ry
DR EQUIVALENT OR BETTER CROSS SECTION BLOCK
F 6 FT HAX.O.C. TO AT LEAST ENTIRE
1. BOTTOM Or TRENCH
0,5' BEFORE PLACING GRAVEL 2'x2'x5' WmD POST _ Deslpnec: CAD
EXISTING l2' DEEP. B' WIDE TRENCH EQUIVALENT OR BETTER — D011NSPOUT Drawn: NDA
GROUND SURFACE T, EX
Chackatl: CAD
FILLED WITH 3/4' TO 1 1/2' �" Scale 1-_20'
2 WASHED GRAVEL OR vfGET0.
L2'DEEP, 8' VIDE 1 2.5' SBLOCKPLAS Date: 09/12/24
TRENCH FILLED WITH 10' DIRECTION DF—�;_1 FXTST1N, ,lob No.. 24183
3/4' TO 1 1/2' I 2.5' vATER FLOW 12 ! GRDUkO SERFAGE
WASHED GRAVEL OR VEC TIQ;4 L FEATURES C(INTANEP�IN THS pRA�ING, Sheet Ne.:
2.5 N0.UDNG BUT NOT l�!LED T0,BOUf�ppMY,
BOTTOM EXTENTS[IF I 1 RIGHT-OF-Il'AY,EASEMENT,PARCEL LINES,
GEOTEXTILE FABRIC N.T.S. SPLASH BLOCK DETAIL BEARINGS.DISTANCES,AETLMDS AND
i NTS BUFFERS,WERE DERIYED FROM PUBLIC SILT FENCE DETAIV_
RECORDS OR ACOUARED FROM AUTOCAD , of 1 Shasta
DRAWS SUPPLIED BY OTHERS.
09/23/2024
APPROVED
LOT STATISTICS LEGEND NOTES: ALLYN 10 MASON S�(77TRUEDYA1�PLANNING
LOT AREA: 4,800 SF —X—X— SILT FENCE 1. BUILDING IS OFFSET 6.00' SOUTHEAST p 'a
AND IS ALIGNED PARALLEL TO THE LOT 5 Digitally V
PROP.FOOTPRINT: 1,872 SF NORTHWEST PROPERTY LINE. TAX PARCEL NUMBER: 122205061005 Signed a:
�. '�y:i, CONSTRUCTION s ocR edy
ti by Scott C N
r -i- COMPASS W
COVD PORCH/PA110: 195 SF ENTRANCE ADDRESS: 61 E 2. SEE ARCH. PLANS FOR ROOF MTT HOMES NORTHWEST Ruedy o,
TOTAL BUILDING COVERAGE: Z067 SF OVERHANG DIMENSIONS. t
I TOPSOIL Front yard-15 feet.10 feet on cul-de-sacs as long as the (206) 466-0991 All setbacks are measured from the furthest p
DRIVEWAY CONC.: 496 SF STOCKPILE average setback is 15 feet. PLAN #CED-1479 projection of the building. Z `
Side yard-5 feet,or less with review and approval of an GRAPHIC SCALE C
TOTAL ROOF AREA: 2,356 SF _sue administrative building variance e W
SEWER BAV2024-00008-4'MIN SUBJECT TO BLD CODES . �
TOTAL IMPERVIOUS AREA*: Z852 SF —. RearStree side yard-8 feet ^L`l)
�SD� Rear yard-10 feet.In cases when the rear yard abuts a �e rar 1 R � d�
TOTAL IMPERVIOUS: 59% —— 9= right-of-way,the primary structure setback shall be 20 feet. 76 24.00'
'TOTAL IMPERVIOUS AREA FOR THIS LOT NC.IAES: —w
_—
ALL ROOF,UNCOVERED PORCH,PATIO, W
DRIVEWAY,AND SIDEWALK AREAS. WATER
8 WATER SERVICE °
All required setbacks shall be measured from the nearest S73'00'00°E 120.00'
property line,except that front yard setbacks shall be measured
from the property line or the edge of an access easement. 10.00' 10��t — 30,QD' k 30.00' _
SEE RESIDENTIAL CONSTRUCTION ENTRANCE a , ,- 5 BSBL
DETAIL NOTE: FUTURE CONCRETE DRIVE TO BE I ? a^, I SILT FENCE19 Z I o 3
INSTALLED OVER THE CONSTRUCTION ENTRANCE. I LOT 5 g o
AT FLOW LINE 10% Ay m ° I Z to
m
Public sewer and water 21 b_ a,, ` I N W I -� I
JI I a � 48.00' I Io I ;I I �• 0
Q 2
II P y I
U J I i Z = o
_ I �- I— o
�o gy�rro a I I S73736'00'E 120.00' INSTALL CB PROTECTION (TYP) J Z O Nu
3
Sod 4Si/ �i Q PROPOSED STRUCTUR S EX.6'SSCO J O C u
R sa�4,o 7fAdQ =�.ro U ROOF DRAIN LINE ) RIM=64.43' Q U
q zgNfO W SPLASH BLOCK (TYP.)SEE ROOF DOWNSPOUT CLEARING LIMITS IE=59.9' HOUSE Z
DETAIL 1 ON THIS SHEET zp m
EH APPROVED ROOF DOYMSPOUT SERVES UP TO—
EH
700 S.F.OF ROOF.
25'MIN.RADIUS '
Rhonda Thompson 11/14/20",
6'MIN.THICKNESS
OF 3/4'TO 1-1/2'CRUSHED GRAVEL BAV2024-00008-4'MIN SUBJECT TO BLD CODES N
PROVIDE FULL WIDTH OF INGRESS/EGRESS AREA N.T.S.
STABALIZED CONSTRUCTION ENTRANCE All setbacks are measured from the furthest -
projection of the building. N
I�EOTEXTILE FABRIC
GEOTEXTILE FABRIC SPLASH
2'x2'Vm0 PBST<TY% WRAP AROIMD TRENCH - a` V
ANTI JT?E �sH CROSS SECTION BLOCK
OR EQUIVALENT dt BETTER TO AT LEAST ENTIRE
V 6 FT MAX.ELC. BOTTOM ff TRENCH
0.5' BEFORE PLACING GRAVEL 2•x2•><g' WOOD POST OR Designed: CAD
�- EOUIVALENT OR BETTER DOWNSPOUT Dr Checked: CAD
NDA
[XISTIIVri -. _. .._ .. .. ."" 12' DEEP.8' VIDE TRENCH
cRD,ND sutRFACE �, FILLED VITN WASH Tp 1 112' T EXTENSION
I Scale: 1-_20'
WASHED GRAVEL OR vEGETATN BLOCK Data: 09/t2/24
12'DEEP, B' VIDEDViCCTIQ+t» 1 15, Job:0, 22/24
TRENCH FILLED WITH 1.01 WATER FL13V - "" GROL"FXISTINCSuRFACE Sheet No,
WASH TO t 1/2' 2.5' 12 FEATURES CONTAINED IN THIS DRAWING,
WASHED GRAVEL OR VEG T � � 2.5' INCLUDING BUT NOT UNITED TO,BOUNDARY,
BCRTOM EXTENTS OF RIGHT-OF-WAY,EASEMENT,PARCEL ONES,
GEOTEXTILE FABRIC N.T.S. �- 1 SPLASH BLOCK DETAIL BEARINGS,DISTANCES,WILANDS AND
SILT FENCE DETAIL BUFFERS,WERE DERIVED FROM PUBUC
NTS RECORDS OR ACQUIRED FROM AUTOCAD
DRAWNGS SUPPUED BY OTHERS 1 of 1 Sheets
<<011-V
t \y MASON COUNTY Mason County Permit Center Use:
COMMUNITY SERVICES BAV
Building,Planning,Emironmental Health,Community Health
615 W.Alder St.—Bldg.E,Shelton,Wa 98584 Date Rcvd
Phone:(360)427-9670 ext.352♦ Fax:(360)427-7798
Fee: S aZ50 00
Request for Building Administrative Variance for
Side Yard Reduction (Urban Growth Areas only)
Please fill out the following form for a request in reduction of the standard side yard setback
required for your zoning. The maximum allowed reduction will be based off of building and fire
code regulations; critical areas (if present)will also be considered. Setbacks are measured from the
furthest projection of the structure, including roof eaves and gutters.
Applicant/Owners: MTT CONSTRUCTION LLC
Mailing Address: 16000 CHRISTENSEN RD STE 150
City: SEATTLE state: WA Zip: 98188
Telephone: 253-508-2156
Email: KASH@MTTHOLDINGS.COM
If this reduction is tied to a building permit, please give permit case number.
BLD 2024 -
Parcel Number(s): I P_a a V'5 D-�1001155 Zoning
Site Address: (p I E COMPASS LN. ALLYN, WA 98524
Requested setback variance (side yard only):
ft. ❑ North
ft. ❑ West
ft. ❑ East
ft ❑ South
Side Setbacks-From the side property line. Minimum side yard setback allowed is based off of Table
R 302.1(])from the International Residential Code (IRC). See next page for table.
An illustrated site plan is required.
Your site plan must show the following: north arrow, abutting street or easements, and set backs to all
property lines and existing buildings, slopes, surface water, wetlands, critical areas, septic, well and
driveway. Show all proposed new development.
Table R 302.1(1)
Exterior Walls
Exterior Wall Element Minimum Fire Resistence Rating Minimum Fire Separation Distance
1-hour tested in accordance with ASTM E 119 or
Fire-resistance rated <5 feet
UL 293 with exposure from both sides
not fire-resistance rated 0 hours 25
Walls
not allowed N/A <2 feet
Fire-resistance rated One hour on the underside- z2 feet to<5 feet
not fire-resistance rated 0 hours >_5 feet
Projections
not allowed N/A <3 feet
25%maximum of wall area 0 hours 3 feet
Openings in Walls unlimited 0 hours 5 feet
All Comply with Section R302.4 <3 feet
Penetrations None required 3 feet
For SI:1 foot=304.8 mm
N/A=not applicable
1.Roof eave fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave if fireblocking is provided from the wall too olate to
the underside of the roof sheathing.
2.Roof eave fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave provided that gable vent openings are not installed.
SIDE YARD REDUCTION REQUESTS: Explain how the circumstances preclude a reasonable
development proposal from meeting the setback standard for the residential zone in your Urban
Growth Area(Shelton,Allyn, or Belfair).
Owner/Agent(please indicate)
Signature Date
Official Use Only
Planning Approval: Date
Building Approval: Date
Denied by:
Reason for denial: