HomeMy WebLinkAboutBLD2007-00012 Final Detached Garage - BLD Permit / Conditions - 1/14/2008 Inspection Line(360)427-7262
MASON COUNTY DEPT. OF =4MUNITY DEVELOPMENT Phone: (360)427-9670,ext. 352
Mason County Bldg. III 426 W. Cedar P.O. Box 186
IrP4 Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT BLD2007-00012
OWNER: JACK DAVIES RECEIVED: 1/4/2007
CONTRACTOR: SOUND BUILDING SYSTEMS, INC. LICENSE: SOUNDBS027NM EXP: 8/19/2008 ISSUED: 8/9/2007
SITE ADDRESS: 270 NE ERICKSON DR BELFAIR EXPIRES: 2/9/2008
PARCEL NUMBER: 223047500120
LEGAL DESCRIPTION: TR 12 OF SURVEY 4/120
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
CONSTRUCT DETACHED GARAGE
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.: V-B
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck:
Type of Work: ACC Fire Dist.: No. of Stories: 1 Occ. Load: Building: Garage-Detached 1,008
Valuation: Building Height: 14 Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline& Planning Information
Make: Length: Ft. Front: E 90.0 Ft. Shoreline: Ft. Water Body: Category III Wetland
g Rear: Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Side 1: N 20.0 Ft. Shoreline Desig.: Not Applicable
Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee JRN 1/4/2007 $280.57 B12007000
EH Plan Review TW 1/11/2007 $35.00 612007000
Building State Fee RTB 8/2/2007 $4.50 B12007000
Building Permit Fee RTB 8/2/2007 $411.45 612007000
ADJUST--Plan Check Fee RTB 8/2/2007 -$13.13 612007000
Total $718.39
BLD2007-00012 Please referto the following pages for conditions of this permit. 1- of 5
` CASE NOTES FOR
` BLD2007-00012
CONDITIONS FOR
BLD2007-00012
1) No clearing will be permited within 60 feet of the designated wetland vegetation area; and no construction within the 15 foot building setback required
beyond the vegetation area X 4C7 to
2) A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at
(360) 427-9670, ext. 450. The building permit will not be"finaled" until the permit holder can show proof that the access permit from Public Works has
been "finaled" and approved.
X /C t✓
3) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X X t,.
4) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved
access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where
such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road.
X fl-,W
5) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed.
X ,j!�_ !..-.4
6) Water quality is not to be degraded to the detriment of the aquatic environment as a result of this project.
X ICw
7) A site inspection by planning staff is required prior to final permit approval. Please contact Charles Mead McCoy III at (360) 427-9670 ext 294 to schedule
the inspection.X /C I✓
8) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
x
9) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X w
BLD2007-00012 Please refer to the following pages for conditions of this permit. 2 of 5
1C) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are required for this proposed development and
construction must be obtained PRIOR TO SAME DEV.ELOP(L;ENT AND CONSTRUCTION. X )f W
111) -All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building
Department prior to any further inspections being performed or approvals granted.
X �PJr
12) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X ,K_/.,
13) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
X removal of roved documents will result in failure of required building inspections.
14) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
permit shall be applied for, reviewed and approved prior to the change.
X
15) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 'W
16) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the "approved" site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the
Building Department prior to any further inspections being.performed or approvals granted.
X r_ ✓
17) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X %w
18) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international codes and Mason County Regulations unless a "Change of Use" permit is applied for, reviewed and approved.
X Pli
19) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be
charged and all be collected by the Building Department prior to any further inspections being performed or approvals granted.
BLD2007-00012 Please referto the following pages for conditions of this permit. 3 of 5
2,Q) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X
21) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project.
X 1F%i.✓
22) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
X K i,✓
23) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
X jr—1,)
24) All property lines shall be clearly identified at the time of foundation inspection. X ff l,✓
25) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
X ,)Cir
26) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented action from being taken. No more than one extension may be granted.
X 6,/
27) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material.
X �c�,✓
28) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure
these structures meet the setback conditions listed.
x 1�w
BLD2007-00012 Please referto the following pages for conditions of this permit. 4 of 5
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owneror the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and stru ture for eview and inspection.
OWNER OR AGENT: _./��- DATE:
BLD2007-00012 Please refer to the following pages for conditions of this permit. 5 of 5
00 v
o CONCRETE MECHANICAL MANUFACTURED HOME D
oC) Date) Footings I Setbacks$ L3 07 Gas Piping By Ribbons _ m
o Interior Date By Interior-Date By Date By N
o L
N Exterior Date g �L0- By 10_t,A Exterior-Date B Set.up D
Point Load I isolated Footings INSULATION Date By 0
BG I SLAB INSULATION
Date By Data By FIRE DEPARTMENT
Foundation Walls Floors Date By
Date By Data By DECKS
FRAMING Walls Date By
Date By Data By PROPANE TANKS j
PLUMBING Vault Date By
Date By OTHER
Groundwork Attic
Type-
Date By Date By Date By
D.W.v DRYWALL Type.
int Brace Wall Date By co
Date By Date By FINAL INSPECTION 0
ni Water Line Fire Sepe ration 1 IV
Date By Date By Date I — tr — t�� By p
m
Pass or Request Inspect. c
Type of Insp. Fail Date Date Done By Comments o
CD
0 ��s g zl o� �3J4? N
4—�►,,o„t t�o,.S (� offs / ly b�S -7BT4-
CD
N
M
O
8
D_
O
O
O
7
N
(D
0
M
uj
Q
to 4
z
J U LL u; LL J li J IL tL � Q y U
Q d Q d) c� p
X@
x
LL
ODD CN
_ � � O r
cn Z
�D Qu � =s
W U ZQ V 46
1: W uj O V NJ0
Z V _ CAZ r i
a � Q �i— 4 - N a
LLI WQ � W.
�— Ln � ur a W
r cv u Q
WSW �Ep Q� W
W - Q
� ; Zo Wo � lu Q J J a
4 ( z p
p LL W - > W >
J O +�- Z W � (� W W
lu X R cn p w 0 a Z Q Z -j
p 4 � 004 DW ► p p m
F- Z Z J J tQ-
a � � - - a o X vs
Lti
W Z 1-
W J W
\ G N Gm N
w
/ LL
w
cN
� � p �
� Z co WWZ (
w � � �
C� Uw
w
- z -
I djO � w • _ — — � w WgWlL
Zw�
w � O � — v0
zw � Qw p �/
w � �
w
/ Z
LL
(N
z Wi
(S) o `f) c� tl �
� x
II I w
w
I -1wLul
pz L -JL -J
o
I _ , Sm'
I I �
I
W �D
z }
0 I
I I I —
I W r
/ cn
Iw // � W
I O }
v 99'-83�6
I A
a
� z 1
I
e � o
111
i
I 1
MASON COUNTY PERMIT NO. Z adO�
BUILDING PERMIT APPLICATION C)00 Y
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 Nt✓ CON
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INFORMATION
Owner Xi f f' Lc r Company Name So-sad ;I t
Mailin Address I '4 Y< Mailing Address 3S144, / hor„ . kG Roa�J
City Fort Ore-her4State it/A ZipCode 413610 City fort Lt-jso,,-� State Zip Code 9N.51
Phone 3600-87y - 03 &to Other Ph.3bv-,2 96- 3 7 R!'ecil Phone 3rAo-1197 I d 1 9 Other Ph.
Lien/Title Holder Contractor Reg.#SoubD Bs os7 nIr; Exp. Z,u- o e
E mail address E Mail Address
Drivers Lic.# DOB Drivers Lic. # DOB
SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Connect to Water System Name of Water System
Well Sewer System Name of Sewer System
PARCEL INFORMATION - 12 Digit Parcel No. AA 3 a 7S'ao Ix Fire District
Legal Description ,
Site Address (Please include street name, street number/�and city) .t7a Er; k s e h Dr,re-
��1 f�.• /�
Directionsto site�n.rti to Igelfu Take,. �Id lee-44lr Nwv' Wr"t (le Ft) o.t 82ni Crs o k UL ✓a a /�al.
Leff oft Er. k aA r- S'tc en
Will timber be cut and sold in parcel preparation?Yes/ No
Is property within 200' of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs
Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No
TYPE OF JOB - Newest Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑
Use of Building 61—ple- Describe Work (ke to—t—� o� max' k3L' x i.� nola bkildlwl
No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor
3rd Floor Basement Deck Covered Deck Other Sq. ft.
Garage—'-" Attached Detached lO u X Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ Replacement Unit? Yes/ No
Installer Name Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative, or the contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all
the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work
proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or
agent on owners behalf, represents that the informaticn provided is accurate and grants employees of Mason County access to the above
described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is
not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY
MEANS OF PROGRES�4NSP CTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X -`: "�'' ��,, -� Date: `7 '2G - O 3
.';, ner/Owners Representative/Contractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date
DEPARTMENTAL REVIEW APPROVE DENIED NOTES
Building Department 11)
Planning Department
Environmental Health Department
Fire Marshal
FEES
Building Permit Fee Site Inspection
Plan Review Fee 67_ .`� EH Review Fee
Plumbinq & Base Fee Planning Review Fee
Mechanical & Base fee Other
Wood /Gas/ Pellet Stove Fee State Fee y ��
Violation Fee Pre-Paid at Submittal
Valuation $ TOTAL FEES