Loading...
HomeMy WebLinkAboutBLD2014-00518 Final SFR and Garage - BLD Permit / Conditions - 8/4/2015 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 P14 RESIDENTIAL BUILDING PERMIT BLD2014-00518 OWNER: CYNTHIA DOUGLAS RECEIVED: 6/10/2014 CONTRACTOR: LICENSE: EXP: ISSUED: 7/21/2014 SITE ADDRESS: 8551 NE BEAR CREEK DEWATTO RD BELFAIR EXPIRES: 1/21/2015 PARCEL NUMBER: 223047500160 LEGAL DESCRIPTION: TR 16 OF SURVEY 4/120 PROJECT DESCRIPTION: DIRECTIONS TO SITE: RESIDENCE WITH GARAGE BELFAIR HWY 300 CONTINUE TO LID BELFAIR BELFAIR HWY TURN LEFT ON BEAR CREEK DEWATTO RD SITE IS 7 MILES ON LEFT General Information Construction&Occupancy Information Square Footage Information No.of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R3U Lot Size: Deck: Type of Work: NEW Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:1,793 Garage-Attached 591 Valuation: $ 223,707.95 Building Height: Occ. Status: Primary Basement: cov porch 54 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: S 190.0 Ft. Shoreline: Ft. Water Body: Rear: N 390.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Shoreline Desig.: Side 1: E 190.0 Ft. Year: Serial No.: Side 2: W 86.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Water Closets (Toilets) 2 Heat Pump 1 Plan Check Fee TW 6/10/2014 $ 1,025.00 S2201400000001 Lavatories 3 Furnace<100K 1 Plan Check Fee TW 6/10/2014 $72.30 S1201400000001 Bath Tubs 2 Ventilation Fan 3 Planning Review Fee TW 6/10/2014 $205.00 S2201400000001 Showers 1 Exhaust Hood 1 Fire Warden Review TW 6/10/2014 $73.00 S2201400000001 Water Heaters 1 Dryer Vent 1 EH Plan Review BJS 6/10/2014 $200.00 S7201400000001 Clothes Washer 1 Building Permit Fee DLC 7/14/2014 $ 1,688.15 S1201400000001 Kitchen Sink 1 Building State Fee DLC 7/14/2014 $4.50 S1201400000001 Dishwasher 1 Mechanical Permit Fee DLC 7/14/2014 $85.70 S1201400000001 Hosebibs 2 Mechanical Base Fee DLC 7/14/2014 $28.50 S1201400000001 Laundry Tray 1 Plumbing Permit Fee DLC 7/14/2014 $ 119.30 S1201400000001 Plumbing Base Fee DLC 7/14/2014 $24.70 S1201400000001 Total $3,526.15 BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 1 of 7 CASE NOTES FOR BLD2014-00518 CONDITIONS FOR BLD2014-00518 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X CP 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X cQ 3) Approved final installation required prior to temporary/final occupancy. X Ll;�— 4) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No foundation drains within 30ft, down gradient of drainfield/reserve area. X L' 5) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. XCCE 6) Owner/A ent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. C 7) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removpLqLapproved documents will result in failure of required building inspections. X 8} THE FQUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X tI BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 2 of 7 9) The "approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the Buil�d(ug Department prior to any further inspections being performed or approvals granted. X 10) 2012 IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine -4C, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49. In addition the following credits from R406.2 shall be completed as follows: Required 1.5 credits: Option 3B (1.0 credit): High efficiency HVAC equipment, air source heat pump minimum HSPF 8.5. Option 5A(0.50. credit): Efficient water heating, Electric water heater with min. EF of 0.93. All showerheads and kitchen sink faucets shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. PROVIDE COMPLIANCE INFORMATION FOR HEAT PUMP, WATER HEATER, AND FAUCETS AVAILABLE AND ON-SITE FOR FINAL OCCUPANCY INSPECTION. Maximum heat equipment output: 26,619 btu/hr X i 11) A permanent certificate, completed by the owner, builder or registered design professional, shall be posted within three feet of the electrical distribution panel. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section 105.4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECCLWSEC Section R402.4. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 750 square feet. Reference IECC/WSEC R401.3 & R101.4.3 Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2012 Certificate"and are available in %or%sheets. The �I Mason County Permit Center will also have some available. X C IT m in lightingfixtures shall be high efficacy lamps in accordance with IECC/WSEC Section 12) A minimum of 75 percent of all permanently installed lamps g y p R404.1. X C BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 3 of 7 13) WIND LOADS - Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. X 14) REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. (IRC 2012 R905.2.8.5) X 0_,0- 15) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. XN��-- 16) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charge¢ar}dshall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 17) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit re o X 18) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAY. X 19) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X o BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 4 of 7 20) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with XasoCC uunty ordinances and building regulations. 21) All property lines shall be clearly identified at the time of foundation inspection. X ��- 22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X GS�� 23) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or-regulation, must be reviewed and approved by Mason County prior to construction. X L 24) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your pro _ X BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 5 of 7 25) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts arl d flGXible air connPctors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal IILI;ngJ shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. X L.�L 26) Approved p dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X � S 27) All construction and demolition debris must be removed from the site after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X C_k�- 28) Temporary erosion control measures must be implemented to prevent water quality degradation of adjace4 waters or wetlands. Silt fencing, straw, or surface matting must be installed and maintained until upland vegetation has become established. X L 29) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X C 30) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Apgzoy Site an to ensure these structures are shown and meet the setback conditions listed. X cl, 31) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 6 of 7 OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT AAPygPLICATION' OFF 180,DAYS WILL INVALIDATE THE APPLICATION. / / /Any o /� i it• �f�H6 t/A /�� _ _ n �! 47 Sig,Xature Do OWNER - REPRESENTATIVE - CONTRACTOR Prinf Name (Circle one to indicate) BLD2014-00518 Please refer to the following pages for conditions of this permit. Page 7 of 7 o CONCRETE MECHANICAL MANUFACTURED HOME p Date By Jjoi outings !Setb Gas Piping ! t. Ribbons (j C) Interior Date By Interior-Date By Date By Exterior Date BPW4 Exterior-Date B Cl) DSet-up Point Load!isolated Footings INSULATION DateBy _< Date By BG!SLAB INSULATION - Z Data gy FIRE DEPARTMENT Foundation Walls Floors Date By = Date C'7-I B JJ Data Z�y By L-02 DECKS D FRAMING Wails Date By Date ;!A of By j,44{ Data By PROPANETAW(S PLUMBING Vault Date � ey Date By THE Groundwork Attic Type. Date By Date By Date By Q.w.v DRYWALL 1a Type- Date ��I /k BY Int Brace Wall Date By m Date By FINAL INSPECTION m Water Line Fire Separation N O Date By Date By Date (.� ! By �L .� m � o Pass or Request Inspect. c s Type of Insp. Fail Date Date Done By Comments CA 0 ile .- co 1� CD JA4 m o: rZ,430S t7n N Cn t 1w Gss 30 �tS 4'S y itS ro PQrmit'# IHI bo I MASON COUNTY BUILDING 111 426 W, CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION N07RICE Job Location `sSS�� h11; Let r CCU& -ttj eco structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be correctgd to gain compliance -&Ic 4t h',I La25a h - - <� a ^6 t 1�rGvt r Ir 1-.'- 4 -ew S Z:FA You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ please contact our office ❑ Make corrections, items will be checked on next inspection regarding possible structural ca (/to °"� Ail -( //(` 1,j ti ( � damage incurred by recent "nal ural/man made" ❑This is not a complete inspection disasters.This is NOT a Date 1 ����/ 7 Departmentl�►� _ CORRECTION NOTICE. Inspector )C� N�L *T 1?, i-�1 �4 ; ' TH11% T, , Jk Permit# MASON COUNTY w BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location SAS hi r Ct+C J�:Iry This structure has been inspected b Mason Count Building Department p Y Y 9 p and the following VIOLATION of County Laws and Ordinances has been found: Items listed below must be corrected to gain compliance I-lz',�,�N c �f s �� �. I.1 •�C1.1 f C 6' a (t f:.C''L 3 y T• l.i � >4— :1 ti tEtil _s:t� f3iii-rsc' T _ �'( Cam? 4o-- •�r.sl41l 'e -, � I'.4LG_ 1I Af4,- /� A f-. I /�T'e— 8,fI'f 4T AA v.r V14 n _ '7 You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ please contact our office ® Make corrections, items will be checked on next inspection regarding possible structural OK to ( Cv� l c' � 0,L,V S damage incurred recent "natural/man made" ❑This is not a complete inspection ,�� '�nn disaster. .This is NOTa Date �i� ��I S� Department 1✓ L16 CORREGWON NOTICE. Inspector L� ff ,C, * N�L *T *4 ' THIqx T, ' * qff �+ 9 A I 331' � PLANNING: ` > ALL SETBACKS ARE:MEASURED FROM THE FURTHEST PROJECTION OF THE BUILDING 3 � �► PLANNING - � APPROVED 66 MASON COUNTY DCD PLANNING SITE PLAN REQUIRED TO BE ON SITE CHANG S SUBJECT TO APPROVAL 0 By Date RECEIVED JUN 10 201tt 426 W, CEDAR ST. �o- T It(,A V) -hn 'DUo as iY,U`1A ��52g i ACCESS & GRADE INSPECTION BLD ADDRESS: �SS� �f Get "GCt-�61ly INSPECTOR: DATE OF INSPECTION: FIRE SPRINKLER REQUIRED?(circle) NO !7 YES IF fire sprinkler required, was notification letter mailed? DATE MAILED: DRIVEWAY ACCESS ( ) need post at access of driveway with reflective address numbers � Length: OD Width: r�, 14 Surface: G_e� Size of turn-around: Condition of shoulders: Vertical clearance: GRADE OF DRIVEWAY D %, OF ROAD % ROAD ACCESS Length: Width: Surface: Condition of Shoulders: Vertical clearance: BURN PERMIT REQUIRED FOR LAND CLEARING FIRE. (_) LOT INSIDE UGA—NO OUTDOOR BURNING PERMITTED. LOT TOO SMALL FOR: BURN PERMITS 4 X 4 FIRES 2 X 3 FIRES PASSED ( ) FAILED ( ) ON HOLD ( ) REMARKS Is-of f0j"-f W 1 ,`rt, elo STD/zLs y�►..� Idl r . ,. 1 � Name Parcel# ZZ50-1 "�5^CO(DO BLD#9Q1 -0� i5 l Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Imperviou' ) Z -) ``''. If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,ackno�e';YCd gh lfe1 Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this deMpUtZMl ity. 42d6 W. CEDAR SST. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work or er or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. rm (�lq X Owner/ en ontractor(circle one)Date: — ( //q If the otal Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name v S Parcel# ZZ JQ9 66 -W t(o0 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A e relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed i h entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions, guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850,Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: RECEIVED Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 JUN 10 2014 Physical: 426 W Cedar St, Shelton WA 98584 425 W. CEDAR ST. A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- des 'bed roperty for review and inspection as may be required. /� I Ig X Owner/ gent/ ntractor(circle one)Date: "l Page 2 of 2 i co MASON COUNTY PERMIT NO. DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING• PLANNING•FIRE MARSHAL 03 5 I _ WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext. 352 1854 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352 BUILDING PERMIT APPLICATION OWNER INFORMATION: t CONTRACTOR INFORMATION: NAME: C tG�S NAME: . L�,,.� 1�4 MAILING DRESS: .©. ( I MAILING ADDRESS:0 2106 (o'a 1.) Q�L CITY: STATE:�p��ZIP: CITY: X�� STATE: ZIP: ' PHONE:10 (*jCELL PHONI :� ,,y p CELL: EMAIL: EMAIL :`7me , L&I REG# $SOS$-R-0 1 EXP.t► /Ls PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) Z C� FIRE DISTRICT LEGAL DESCRIP ION(ABBREVIATED) I l/ i SITE ADDRESS ITY DIRECTIONS TO SITE ADDRESS D I 3 V QA A v oilipulkiiiv uct un Ko&kCv'00Y_1Xkt S�fib. IS PROPERTY WITHIN 200 FT: 15 1 IIA I G� SALTWATER ❑ LAKE ❑ RIVER/CREEK ❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM ❑ DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN 14% YES[] NO TYPE OF JOB: NEW ADDITION ❑1@CCALTERATION ❑ REPAIR ❑ OTHER ❑ USE OF STRUCTURE(RWDENCE,GARAGE ETC.) r K I IS USE: PRIMARY SEASONAL ❑ UMBER OF BEDROOMS. NUMBER OF BATHROOMS DESCRIBE WORK SQUARE FOOTAGE: I ST FLOOR sq. ft. 2ND FLOOR-sq.ft. 3RD FLOOR sq. ft. BASEMENT sq.ft. DECK sq. ft. COVERED DEC sq. ft. STORAGE sq. ft. OTHER2. q. tT '' GARAGE O j_sq. ft. ATTACHED DETACHED ❑ CARPORT sq. ft. ATTACH�DETACHED ii ,I 12w, J MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN t. C DAP, ST. MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF IINSP CT N INA2T"I)� 'HIS�MIT APPLICATION OF 180 DAYS WIL INV 41 %DATE THE APPLICATION. gnature of pplicant Date `7 x byu Wba OWNER / EPRESENTATIVE ONTRACTOR Print Name (CIRCLE INDICATE) IDEPARTMENTAI J EVIEW BUILDING DEPARTMENT — 14-. A10 PLANNING DEPARTMENT FIRE MARSHAL a `7ac� (,o FX Z7b Z"9�� es) Gam" I a a Co CIX �t°aoN coL��� MASON COUNTY PERMIT NO. DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext. 352 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: 1`yj : S NAME:U ��K lr � MAILING DRESS: 1 Z MAIG ADDRESSI)�n(a CITY: STATE: ZIP: CITY. u ,-1 STATE jj ZIP:q%3")3 PHONE:3( ()-Z j [-Jooq CELL: PHONE253 CELL: EMAIL: EMAILc L&I REG#-bSo, EXP. PARCEL INFORMATION: n � ,, PARCEL NUMBER 12 DIGIT NUMBER): l�3� 16-001 LOCI' LEGAL DESCRIPTION(AB MATED):._.- I SITE ADDRESS: .1 r i M CITY: Itl 11 j DIRECTIONS TO SITE ADDRESS: t (Q (--)b Vi COWh TYPE Of JOB NEW ADD ALT REPAIR OTHER USE OF BUILDING LOCATION OF FIXTURES/UNITS— 1ST FLOOR V 2ND FLOOR BASEMENT GARAGE k1r OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNIT Tyne of Fixture No. of Fixtures Fees Fuel Type:Electric VLPG Natural Gas Heat Pump_ Toilets \� 2. Type of Unit No.of Units Fees Bathroom Sink \, 3 Furnace Bath Tubs V Heatpump Showers%,,V�00 Spot Vent Fan _ Water Heater Propane Tank Clothes Washer 1 Gas Outlets Kitchen Sinks f Wood/Gas/Pellet Stove Dishwasher I Kitchen Exhaust Hood Hosebibs 2 Dryer Vent f Other LO Uo U� I Other J � 77 -E i V E111 D Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL I ! OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permite,yqcaticLn.L D a R S T. Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION QF 180 DAYS WILL INVALIDATE THE APPLICATION. X � U 0 IN Si ature of Applicant Date X KOLA — Owne k Hers Representative ontractor Print Name (indicate which one) tftPARTMENTAI<REVIEVL' KY,P iJ BATE fif&f E-b ICE T—G-S- utkSTCd. 1 0 j§ BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL