HomeMy WebLinkAboutBLD2021-00856 SFR - BLD Inspections - 12/17/2024 MASON COUNTY 615 W.Alder St.Bldg 8,SHELTON,WA 98584
I.
COMMUNITY SERVICES SHELTON:360-427-9670,EXT 352
BELFAIR:360-275-4467,EXT 352
Building Planning,Environmental l Ic Ith,Community I With ELMA:360-482-5269,EXT 352
www.co.mason.wa.us
INSPECTION CARD AND CERTIFICATE OF OCCUPANCY**
To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php
Permit Number BLD2021-00856 Date Issued 09/01/2021 Issued By
Project NEW 2 STORY SFR W/BOTTOM WALK OUT GARAGE
Site Address 41 N Mardell Ave
Applicant CORCORAN MARK&AMY
Contractor
Contractor Phone
Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type
Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy
-APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS.
-DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED.
-THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY.
-ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION.
-OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION.
**THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.**
PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET
Public Works Access/Driveway Other
Health D Septic Well
eptartment
Planning Site Inspection
Department V1
Fire Marshall Fire Apparatus Access Fire Sprinkler
Auto Fire Alarm Hood and Duct
Other Final
Building
Department Building Official: Community Services Designee
Concrete Setbacks l,• Z Slab Z
Footing Perimeter Point load Footing
Footing Interior Footing Decks/Porches
Foundation Stem Walls _ Other
Rough-In Groundwork Plumbingi L-1 S Framing Z I ( I Z(4
Groundwork Mechanical Plumbing
Groundwork Gas Pipe Mechanical J is/z•{ Ta'_
Gas Piping Shear Wall Nailing /Z
Underfloor
Other
Insulation Slab 71/3 ZZ -:Pa- Ceiling 2 / 2-, J
Floor L(t it 4 _1xk Vaulted Ceiling
Walls j_ Vapor Barrier 42 4
Other V
Wallboard Inferior Wall Brace Panels Fire Walls � '�
Nailing
Other
Y
Final Building �2 /? ,Z� ''7Alzql2S
ManufacturedSetbacks Setup
Home
Concrete Foot/Runners Final
Other
l�
2- �&A
a 1 lY
F 172- T Z.3
C'�htl(� : 31..�e�r O F. f'a�l S4 11ITIZ3I/j'! PL—S -�+01 ,1 Fr""�"l FHrI /ZS�Z�f
o r' ♦ ,
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY SERVICES 360-482-5269 Elma ext.352
Building,Planning, Environmental Health,Community Health
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER. n-Q Z j-M(9=, :S(0
ADDRESS/LOCATION: vf� .
FINDINGS:
, e n n &,de --as- k oem m
rYv�,► rk.
2 r ov
Cb
n
1 h
►�
Items listed above must be corrected to gain compliance.
NEZHIS IS NOT A COMPLETE INSPECTION
This structure has been inspected by Mason County Building Department and the items listed
,�P,Bove are m VIOLATION of Mason County laws and/or ordinances.
all for re-inspection when corrections are made before proceeding with any further work.
Make corrections, items will be checked on the next inspection.
OK to
Date:_— - Z C, ❑ Please contact our office regarding possible
Department: ML structural damage incurred by recent
Inspector: y-r 1 "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY 360-427-9670 Shelton ext.352
Belfair352
COMMUNITY SERVICES 3 0-275-4467 360-482-52 9 Elma exit.352
Building, Planning,Environmental Health,Community Health
615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER. ` Z.�-p(� BSCp
ADDRESS/LOCATION: LA\ N mat\GAY Ave
FINDINGS•
�J 1lie
V � vcW
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
-�all for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to
Date:(P—- , ❑ Please contact our office regarding possible
Department: structural damage incurred by recent
Inspector:41f "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC 14.12
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352
Building,Planning,Fire Marshal
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: 19L0 2nzi —tioSsrg
ADDRESS/LOCATION: 4l N. A ard•.t1 Aw_
FINDINGS: ( `runs
S
Via.- �n�r -to A.re K� .Ka �tY✓►
Items listed above must be corrected to gain compliance.
THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call for re-inspection when corrections are made before proceeding with any further work.
Make corrections, items will be checked on the next inspection.
❑ OK to
Date: 3 ❑ Please contact our office regarding possible
Department: 3LD structural damage incurred by recent
"natural/man made"disasters.This is NOT a
Inspector: .lam CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext. 352
COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352
Building,Planning,Fire Marshal
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: bL-D Ziz t - Do RS-G
ADDRESS/LOCATION: iq► tiJ Aa j u W�w
T
FINDINGS: ,L^j 5
t7 l— A^ Ins; of
Caw"V- Must- !9 '1 a r &I aw njrft- l- 2S fi
r-1c�1�.t,r+r� •U,si�n•, IG�k. o��l- on 1�aoQ 1��c�.
Items listed above must be corrected to gain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
❑ Call for re-inspection when corrections are made before proceeding with any further work.
Make corrections, items will be checked on the next inspection.
OK to -D%Svlwk, - t7o Ltd l—�w,sOtad� cor"C' 9,,—
Date: ILq ❑ Please contact our office regarding possible
Department: -6�, structural damage incurred by recent
Inspector: -t2�y "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352
Building,Planning,Fire Marshal
615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: bL p 2o-2 � — oo gS-G
ADDRESS/LOCATION: y_l N, Arilj ji Am-
FINDINGS: fi*iaw, pl,,,, p j S 1{ SL ,r Weat Sct,,.al...,l S W.3
5 W i f lk, cs-t- g"rt- M i LA • S W O W 4.4 IS " O L cyJh.A�—
;s �aP:aJs(t_ y S ai,.,j,c_ A,9LJ iUa�t Lg
S W `l wuAA �s ` o c. CW La ;Ain-o whk tlS
iv`oG or &It
•tm LT P �l 7"a c o r q W ng s.
RL^ pol S14 ID 2 2S 2 Sl.r
W W t�(� ?4 a.l-c A O(d On�`0P
ca.l,t��-a�s A-re PN.%U l— atna( ytr Ltd
F ZA4 NOt— I�aaLrl
Items listed above must be corrected to gain compliance.
THIS IS NOT A COMPLETE INSPECTION
This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call for re-inspection when corrections are made before proceeding with any further work.
Make corrections, items will be checked on the next inspection.
OK to
Date: 11. bf/0 ❑ Please contact our office regarding possible
Department: 'Q LP structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
•� MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY DEVELOPMENT 360-482-5269 Elma ext. 352
Building,Planning,Fire Marshal
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMIT/CASE NUMBER: ZLb 2-a 2-I ---pp 8S G
ADDRESS/LOCATION: L4 (
FINDINGS:�ENrA.'Y-4
C��rC�.cd in tZc A
C-i L � r
r 1 our —Otot i,.)n 1, rv4-A- lrn^au � Nab- Rr sr- —
P4 U-11-cr 1-coves E6 IZ ;�o r Co mr.e�t.V�e._ .Lkw w�S
it 4 o r L. S�e,14 `fir QkA^.
5L
&r AIL u-)e..tUsAr
A 31�c1.",A, ?,-A v; ,,-A OWL clrt rG W a,to Am Lakt r
Items listed above must be corrected to !lain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
OK to
Date: 12 ❑ Please contact our office regarding possible
Department: L�L 0 structural damage incurred by recent
Inspector: �� "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
INSPECTION RESULTS Pagel
MASON COUNTY Department of Community Development
COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584
Penult Assistance tenter,budding,Planning (360) 427-9670 ext. 352
Application # BLD2021-00856 Application Type NEW SINGLE FAMILY Owner CORCORAN MARK&AMY
RESIDENCE
Parcel# 422015005008 Site Address 41 N Marcell Ave Hoodsport, WA 98548
Inspector Inspection Type Date Status Comments
11-19-24-J Q
�e n�cy,o�
4rr-Wo( CODE OR LOCK BOX CODE 7832
-54 DECK-WIRE GUARDS SHALL BE SPACED NO GREATER THEN 3-5/8" OR SO
A 4" SHPEAR CAN NOT PASS THROUGH -CURRENT CONDITION IS 6"
BETWEEN WIRES
A GRASPABLE HANDRAIL WITH TURN OUTS IS REQUIRED PLEASE SEE
COUNTY HAND OUT FOR DECKS
XSTORMWATER RUNOFF IS IMPACTING AJACENT PARCELS PLEASE
CORRECT WITH PROPER DRAINAGE PER COUNTY CONDITIONS.
Joshua X.Blower door test is not completed please post permanent WSEC with in 3'of
Quarders BLD-FINAL INSPECTION 11/19/2024 FAIL electrical panel. 5 ACH or better
install anti tip device on range
Range vent is corrugated piping please remove and install Smoothwall pipe.
!Smoke detectors are not alerting when placed on test. please correct
�,W Install erosion control around perimeter of dwelling (bark, gravel, straw)
nstall 90 degree turn down on T&P drain. at exterior rear wall
IF ANY OUTSTANDING CORRECTIONS REMAIN PLEASE ADDRESS BEFORE
NEXT INSPECTION IS SCHEDUALED
CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE
PROCEEDING WITH ANY FURTHER WORK.
INSPECTION RESULTS Page
MASON COUNTY Department of Community Development
COMMUNITY DEVELOYMEW 615 W Alder St, Shelton, WA 98584
Permit Assistance Center,Building,Planning (360) 427-9670 ext. 352
Application# BLD2021-00856 Application Type NEW SINGLE FAMILYRESIDENCE Owner CORCORAN MARK &AMY
Parcel# 422015005008 Site Address 41 N Marcell Ave Hoodsport, WA 98548
ins �'tor._ Ins ection T ,e, .. Date Status Comments
v►a:1 Act.t 1 AU tong � u.'S 12-3-24-JQ
J� Per signed county conditions pg. 8 of 8 a fire permit for fire suppression is required
IZj`(j&4 prior to final inspection
please contact the Fire Marshals office @ 360-427-9670 x 309
(2'Per the approved plan pg. S2 a 1-hour fire rated self-closing and latching door shall
separate the garage from living space above. please correct-current condition no fire
3 separation door is in place separating the garage from the living area above.
3. Per IRC R 311 not less than 1 egress door shall be provided to access the exterior
of the dwelling and not through a garage. A sliding door is not approved as an egress
door. Egress doors shall be side hinged exterior grade with a clear width of not less
, ���d than 32". Please review the referenced code section and correct the current
64aill't *'�'`" condition. -the sliding glass door leading to the deck and stairway will need to be
jVgeisb, replaced with a side hinged door that conforms to the referenced code section.
s �
previous corrections have been addressed and are ok this date.
CALL FOR REINSPECTION WHEN CORRECTIONS ARE MADE BEFORE
PROCEEDING WITH ANY FURTHER WORK.
11-19-24-J Q
Joshua BLD-FINAL INSPECTION 12/03/2024 FAIL 1. NO ACCESS AT TIME OF INSPECTION PLEASE PROVIDE ACCESS (GARAGE
Quarders CODE OR LOCK BOX CODE) 7832 contractor arrived access was granted.
pl, DECK-WIRE GUARDS SHALL BE SPACED NO GREATER THEN 3-5/8" OR SO
�A 4" SHPEAR CAN NOT PASS THROUGH -CURRENT CONDITION IS 6"
BETWEEN WIRES
3�A GRASPABLE HANDRAIL WITH TURN OUTS IS REQUIRED PLEASE SEE
COUNTY HAND OUT FOR DECKS
4. STORMWATER RUNOFF IS IMPACTING AJACENT PARCELS PLEASE
CORRECT WITH PROPER DRAINAGE PER COUNTY CONDITIONS.
0lower door test is not completed please post permanent WSEC with in 3' of
INSPECTION RESULTS Page
MASON COUNTY Department of Community Development
COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584
Perm It Assistance Centel,Budding,Planning (360)427-9670 ext. 352
electrical panel. 5 ACH or better
install anti tip device on range
Range vent is corrugated piping please remove and install Smoothwall pipe.
�S Smoke detectors are not alerting when placed on test. please correct
Install erosion control around perimeter of dwelling (bark, gravel, straw)
/ Install 90 degree turn down on T&P drain. at exterior rear wall
IF ANY OUTSTANDING CORRECTIONS REMAIN PLEASE ADDRESS BEFORE
NEXT INSPECTION IS SCHEDUALED
CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE
PROCEEDING WITH ANY FURTHER WORK.
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
' Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
F
-00856 NEW SINGLE FAMILY RESIDENCE
ESCRIPTION: NEW 2 STORY SFR W/BOTTOM WALK OUT ISSUED: 09/01/2021
ESS: 41 N MARDELL AVE HOODSPORT EXPIRES: 02/28/2022
PARCEL: 422015005008
APPLICANT: CORCORAN MARK&AMY OWNER: CORCORAN MARK&AMY
7300 E GREEN LAKE DR N 7300 E GREEN LAKE DR N
SEATTLE,WA 98115 SEATTLE,WA98115
206.601.2551
OTHER: LARRY STEVENS
123 XXX XX,XX.00000
VALUATIONS: FEES: Paid Due
U VB Utility, miscellaneous 928.00 $45,277.12 Plan Check Fee $1,315.13 $0.00
Uncovered Deck 478.00 $7,170.00 Mechanical Base Fee $30.00 $0.00
Covered Deck/Carport 411.00 $9,042.00 Building Plan Review/Change of $120.00 $0.00
Use-Onsite Sewage
R-3 VB Residential, one- 1534.00 $189,725.12 and two-family Plumbing Fees $122.00 $0.00
Building Permit Fee $2,023.28 $0.00
Mechanical Fees $142.00 $0.00
Planning Review Fee $240.00 $0.00
Technology Surcharge $73.15 $0.00
Plumbing Base Fee $25.00 $0.00
State Fee-Residential $6.50 $0.00
Total: $251,214.24 Totals : $4,097.06 $0.00
FIXTURES
(fit Mechanical Fixtures (sty Plumbing Fixtures
1.0000 Dryer Vent(s) 1.0000 Number of Clothes Washers
1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Dishwashers
1.0000 Furnace(s) 1.0000 Number of Kitchen Sinks
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM Page 1 of 8
Mason County
* Mason County - Division of Community Development
615 W.Alder St. Bldg.8
red Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-00856
(Qty Mechanical Fixtures (sty Plumbing Fixtures
1.0000 Heat Pump(s) 1.0000 Number of Water Heaters and or Vent
1.0000 Wood/Gas/Pellet Stove(s) 2.0000 Number of Hose Bibs
2.0000 Number of Bath Tubs
2.0000 Bathroom Sink
2.0000 Number of Showers
2.0000 Number of Toilets
REQUIRED INSPECTIONS
Setback Inspection Framing Inspection
Footing Inspection Rough-Plumbing Inspection
Foundation Wall-Pre-Pour Inspection Mechanical Inspection
Underground Plumbing Insulation Inspection
Underfloor Inspection BLD-Final Inspection
Shearwall Inspection
CONDITIONS
* Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate
building permit and approval prior to construction of the retaining wall.
* The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not
allowed without the approval of the Mason County Fire Marshal.
* The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
* All property lines shall be clearly identified at the time of foundation inspection.
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM
Page 2 of 8
k Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2O21-00856
Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181 A-P for pressure-sensitive tape, 181 A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by
the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or
100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the
access permit from Public Works has been finaled and approved.
* Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* When parcel development requires direct access to state road(s), a Road Access Permit or Approval must be granted and
approved by the Washington State Department of Transportation. For more information contact Washington State
Department of Transportation, at(206)357-2620, ext. 630.
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM Page 3 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
h
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-00856
A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
The foundation/footing must be placed on undisturbed, firm-native soil.
All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site,then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
" Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM Page 4 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2O21-00856
" Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries (L&I).
For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415-
4000.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
* REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
* By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind
speed for Mason County is 85 MPH.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM
Page 5 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
rt Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-00856
* Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
2 Heat pump
1.7 Advanced framing and raised heel trusses or rafters Vertical Glazing U-0.28, R-49 Advanced (U-0.020)as listed in
Section Al02.2.1, Ceilings below a vented attic and R-49 vaulted ceilings with full height of uncompressed insulation
extending over the wall top plate at the eaves.
2.4 Compliance based on Section R402.4.1.2:
Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals or
For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.15 cfm/sf
maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International
Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system
with minimum sensible heat recovery. efficiency of 0.80. Duct installation shall comply with Section R403.3.7. 1
3.6 Ductless split system heat pumps with no electric resistance heating in the primary living areas. A ductless heat pump
system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor
air temperature.
4.2 HVAC equipment and associated duct system(s)installation shall comply with the requirements of Section R403.3.7.
Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat and
ductless heat pumps are not permitted under this option. Direct combustion heating equipment with AFUE less than 80% is
not permitted under this option.
5.6 Water heating system shall include one of the following:
Electric heat pump water heater with a minimum UEF of 2.9 and utilizing a split system configuration with the air-to-
refrigerant heat exchanger located outdoors. Equipment shall meet Section 4, requirements for all units, of the NEEA
standard Advanced Water Heating Specification with the UEF noted above or for R 2 Occupancy, electric heat pump water
heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification and utilizing a split system
configuration with the air-to-refrigerant heat exchanger located outdoors, shall supply domestic hot water to all units. If one
water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8
minimum pipe insulation.
Provide Water heater and Heat pump Specs at or prior to final for verification of eff requirements of energy credits selected.
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM
Page 6 of 8
j
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-00856
* A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls, foundation (slab,
basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the
solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component,the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service
water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3& R402.4.1.2,
and air leakage results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are
available in '/4 or%sheets. The Mason County Permit Center will also have some available.
* A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM
Page 7 of 8
Mason County
Mason County - Division of Community Development
615 W.Alder St. Bldg.8
.i Shelton,WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
NEW SINGLE FAMILY RESIDENCEBLD2021-00856
" Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather,
garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of
3000 psi (IRC Table R402.2).
On-site Septic System final installation approval required prior to temporary/final occupancy of the residence.
Horizontal setbacks per WAC246-272A-0210 must be maintained, unless prior approval is obtained
Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered.
A.) Drainfield/Reserve requires a 1Oft setback from all footing/foundations.
B.) Septic tank(s)requires 5ft setback from all footing/foundations.
C.) No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area.
D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area.
" Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to
the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of
the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In
addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with
the 2015 IBC, Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener
spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S4 designate wall(s)type SW3 and
SW4 with fastener spacing 4 inches or less.
The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified
to inspect lateral connections, the Engineer of record (EOR), or an authorized representative of the (EOR). The special
inspectors duties and responsibilities shall be as specified in Chapter 17. When a third party inspector is used to perform the
inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton,
WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted
to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said
project.
(:�D)er notes fire protection sprinklers are required, fire permit is required prior to final inspection.
SEE CAD.'-I � m AC f-re.,PkxO tit 4}kcW bcAed l2/317-q spri),-",.- W X%-y_d�
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By: GLIA
Contractor or Authorized g nt: Date:
Printed by:Genie Mcfarland on:09/01/2021 01:44 PM
Page 8 of 8
Joshua Quarders
From: Randy Collins
Sent: Tuesday, December 3, 2024 2:09 PM
To: chrispeterson695@gmail.com
Cc: Joshua Luck; Genie McFarland; Joshua Quarders; hugotorres556@gmail.com
Subject: Fire Sprinklers Permit BLD2021-00856 41 N. Mardell Lane
Attachments: BLD2021-00856 Permit Conditions.pdf
Chris,
I appreciate the opportunity to talk with you about this project and the information you provided regarding its
evolution. Based on what you shared, I was able to review the project history as well as the notes in our permit
system.After reconciling them with your comments, I was able to discern the following:
• On September 2, 2021,the original Building Permit was issued to Mark Corcoran
• On January 19, 2022, an extension of the permit was granted thru April 27, 2022
• Between March-July 2022 a series of underground/foundation inspections were performed (no further
inspections were documented until Dec 2023)
• On June 26, 2023,the permit was renewed by Marimar White-Estin. From this point on, construction
proceeded at what we would consider a normal pace.
While the original permit and conditions (see enclosure) identified the requirement for fire sprinklers, because our
records do not show a copy of the permit(or any of its conditions)were shared with Ms.White-Estin,yourself, or
Mr.Torres when the renewal occurred. Based on these findings, I feel it would not be fair to impose the sprinkler
requirement at this time and will be waive it.
In our discussion, I did mention I would delay sending you anything in writing until I spoke with the Building
Inspector to confirm if there was anything outstanding from their inspection who did mention there were several
items that needed correction (to be sent in a separate email) so I would encourage you to coordinate closely with
Mr.Torres.
If you have any questions, please let me know.
Respectfully,
Randy Collins
Fire Marshal
Mason County
360 427-9670 x309
360 490-0167 Cell
1