Fire Alarm System - COM Permit / Conditions - 12/31/1989
PROPERTY p MASON COUNTY FIRE MARSHAL o � mplex Simplex Time Recorder Co. FIRE ALARM SYSTEM SECTION 16720 Submittal Packa &l-ye Pioneer Elementary School Shelton School District Shelton, Washington Simplex Time Recorder Co. 455 N. 35th St. Seattle, WA 98103 (206) 632-4511 FAX (206) 634-0214 Simplex Time Recorder Co. Simplex 455 N 35th Street Seattle, WA 98103 Seattle (206) 632-4511 Tacoma(206) 272-2878 Everett(206)252-0190 Fax (206) 634-0214 Pioneer Elementary Shelton, WA Ace Electric Tacoma, WA Fire Alarm System Index Section I: Bill of Materials Section II: Data Sheets Section III: Warranty Section IV: Testing Section V: Technical Installation Support Corporate Headquarters ■ Simplex Plaza ■ Gardner, MA 01441-0001 U.S.A. ■ (508) 632-2500 Adv 0294-Field Simplex Time Recorder Co. "Simplex 455 N 35th Street Seattle, WA 98103 Seattle (206) 632-4511 Tacoma (206) 272-2878 Everett(206) 252-0190 Fax (206) 634-0214 Pioneer Elementary Shelton, WA Ace Electric Tacoma, WA Fire Alarm System Section 16720 Product Number Description 4020-8001 Fire Alarm Control Panel to consist of: 4020-7003 Master Controller 4020-0112 RS-232 Module 4020-0305 8 Pt. 1/0 Module 4020-2003 6 Unit Package 2081-9271 33 AH Battery FAA-100 Weatherproof Annunciator 4602-8101 Graphic Driver to consist of: 4602-7101 16 Pt. 1/0 Module 4602-2001 2 Unit Package 2099-9795 Pull Station 2099-9813 Trim Plate 2099-9800 Pull Station Wire Guard 4098-9701 TrueAlarm Smoke Detector 4098-9731 TrueAlarm Heat Detector 4098-9781 TrueAlarm Base 4098-9702 TrueAlarm Duct Detector 4098-9701 TrueAlarm Smoke Detector 4098-9803 Baffle 2098-9798 73" Sampling Tube 2098-9808 Remote LED 2098-9207 Beam Detector 2310-9823 Beam Detector Wire Guard 2098-981 6 Remote Test Corporate Headquarters ■ Simplex Plaza ■ Gardner, MA 0 1441-0001 U.S.A. ■ (508) 632-2500 Adv-0294-Field SHG-24HWR Horn, 100 Candela Strobe MIZ-24-WM-VF-R Mini Horn, 117 Candela Strobe EH-ELI-WS-24-VF-R Weatherproof Horn-Strobe 2901-9333 10" Bell 2975-9009 WB-R Weatherproof Box WS3T-24-FR Weatherproof Strobe 2975-9198 WBB-Weatherproof Box 4905-9906 Audible/Visible Wire Guard 2190-9158 4-Wire ZAM 2190-9172A Addressable IAM D8112GB Digital Dialer D360 Keypad D 126 Battery D8109 UL Fire Cabinet D101 F Lock and Key 2190-9042 CRT/Keyboard 2190-9038 Printer 5W604 Cart 5W605 Paper Basket 2088-9008 Remote Relay Spares 2099-9795 Pull Station 4098-9701 TrueAlarm Smoke Detector 4098-9781 TrueAlarm Base 4098-9731 TrueAlarm Heat Detector 4098-9702 TrueAlarm Duct Detector 4098-9803 Baffle 2098-9798 73" Sampling Tube SHG-24HWR Horn, 100 Candela Strobe MIZ-24-WM-VF-R Mini Horn, 117 Candela Strobe 2190-9172A Addressable IAM True: mka I 13,,Simplex Fire Alarm Systems 4020 Series UL, ULC Listed Addressable/Hard-Wired Fire Alarm Controls STANDARD FEATURES: • 80 Character Liquid Crystal Display — Super-Twist Design for Wide Viewing Angle — Back-Lit Alphanumeric Characters — • Same Operator Features as 4100 Series Products • Power Limited Operation Per NEC 760 • 127 Addressable Points • Supports MAPNET II® and TrueAlarmT"' Devices* • 4 Hard-Wired Input/Output (1/0) Points • 1/0 Point Type Field Selectable • 8 Amp Power Supply/Charger • Ground Fault Isolation From Front Panel • City Connection ,,,, • Serial Annunciator Communication Port __ ,.sr.eap±r34lfittFl! • Battery Supervision • Coded Signal Control 4020-8001 FIRE ALARM CONTROL PANEL • Shallow Depth Package MOUNTED IN 2 UNIT CABINET • Flash EPROM Memory SOFTWARE FEATURES: INTRODUCTION: • Standardized Software The Simplex 4020-8001 is a sophisticated Fire Alarm • Easily Customized On-Site Control Panel that provides both addressable and hard- y wired monitor and control in a compact, feature • WALK TEST** optimized package. Similar to the Simplex 4100 series • 4 Operator Access Levels product, the 4020 can be custom programmed to meet • 600 Event Historical Log a variety of applications and local code requirements. • Zone or Point Selectable Alarm Verification Its powerful and flexible software can be quickly and securely modified by trained Simplex field service personnel who can configure, program,and edit on-site. OPTIONAL FEATURES: The system can be easily expanded to 254 addressable MAPNET II points and 20 hard-wired 1/0 points using a • Addressable Expansion to 254 Points field selectable 1/0 module to determine operation as • Hard-Wired Expansion to 20 Points Using 8 either monitor or control. Input points typically are Point 1/0 Card (2 maximum) Initiating Device Circuits such as smoke and heat • RS232 Interface detectors, TrueAlarmTM sensors, manual fire alarm • 4 Unit Shallow Package (pull) stations, and other device contact closures. Output points are typically Notification Appliance Circuits with horns,bells,or strobes.or Auxiliary Control Relays that directly control external devices or connect ID to higher rated relays for specific building control applications. MAPNET is protected under US Patent#4,796,025 TrueAlarm is protected under U.S. Patent#5,565,468. "WALK TEST is protected under US Patent#4,725,818 1992 Simplex Time Recorder Co. Publication S4020-0001-2 11-92 SPECIFICATIONS: Battery requirements................... Standard 4020-8001: Environmental ................................... Operational from .50 amps standby, .64 amps alarm. 32°F (0°C) to 1220F (50°C) Optional 8 Point 1/0 (each module): with normal humidity, and at 10 amps standby, .34 amps alarm. 86°F (30°C) at 85% relative humidity. Optional MAPNET II Module: Electrical Ratings.......................................... .AC Input, .30 amps standby, .32 amps alarm. 4 amps @ 102 to 132 VAC, 60 Hz, Optional RS232/2120 Interface: 2 amps @ 204 to 264 VAC, 50/60 Hz .030 amps standby. PACKAGE MOUNTING DOOR WIDTH 0 2-3/4" 26-3/8" (7 cm) (67 cm) 2-1/2" BOX WIDTH (6.35 cm) 25-3/4" 1-3/4" (65.4 cm) (4.45 cm) r------------------------------------------------ ■ H=20-3/4"(52.7 cm) FOR 2 UNIT BOX =36-1/4"(92 cm) FOR 4 UNIT BOX rCONTROL O INTERNAL BATTERIES ARE LOCATED ON (3.8 cm) BOTTOM OF CABINET. SEMI-FLUSH 5 1/4" CONDUIT ENTRANCE TRIM (13.3 cm) MUST AVOID THIS 1-7/16"WIDE AREA.33AH BATTERIES (3.7 cm) WILL NOT ALLOW BOTTOM ENTRY CONDUIT. • Simplex Time Recorder Co. Simplex Building Systems Gardner, Massachusetts Throughout the U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. Multi-Application Peripherals 1340 ®Simplex and Accessories Batteries and Chargers 2081 Series System Batteries, 6.2 - 50Ah FEATURES: • Rechargeable, Sealed Lead-Acid Design • Lead-Calcium Grid Structure • Immobilzed Electrolyte in Absorbent Separator c • High Reliability Dual Seal Construction • Low Maintenance, No Need to add Water • UL 924 Recognized Pressure Relief Valves • Low Self-Discharge Characteristics • One-Piece, High Impact Polystyrene Cell Cover 2081-9275, 18 Ah BATTERY • DESCRIPTION: APPLICATIONS: Simplex rechargeable, sealed-lead acid batteries Charging: These batteries are intended to be used with provide reliable and repeatable discharge and recharge compatible Simplex battery chargers. characteristics for use in fire alarm and other systems applications. They are designed with immobilized Series Connections: Since these batteries are required electrolyte in an absorbent separator, allowing them to to be connected in series to develop 24 V system provide rated capacity on the first cycle. voltage, battery sets must be of identical voltage, model Because of their sealed construction, packaging is number, and approximately the same date of allowed within the system electronics enclosure (see manufacture for proper operation. figure 1, page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are Testing: Battery capacity testing is recommended to be both minimized. performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge.The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal SPECIFICATIONS: voltage against those predicted for the specific battery Nominal Voltage Rating..............................12 V/Battery size. (Testing is available through Simplex Service). (6 V/Battery for 2081-9211, 50 Ah) Discharge Rating ................20 Hour Rate Disposal: Battery chemicals and materials can be g g"""'"""""""' recycled. Refer to information shipped with the battery Typical Charge/Discharge Cycles.................... 100-150 or on its case. Return to the vendor or to a similarly Preferred Charge Temperature Range..............60-90°F qualified battery processing facility for proper disposal. (15.6-32.2°C) • 91993 Simplex Time Recorder Co. Publication S2081-0006-8 9-93 • Simplex Time Recorder Co. Gardner,Massachusetts 01441-0001 U.S.A. Simplex Building Systems Offices and Representatives Throughout the World Fire Detection • Security • Communications • Time Control All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. FAA-100 Standard mounting WSA Annunciators—The industry standard for instant identification of fire/security emergencies. Designed,engineered,and constructed to be the best,WSA features make the difference. Fire Alarm White photo-emulsion graphics,applied ANNUNCIATOR to smoked plexiglass,assure legibility and ease of on-site updating. Protected by a layer of non-glare plexiglass,each panel is framed in architectural gray aluminum.A key lock and hidden-screw construction provide tamper resistance.Convenient ' removal and reassembly of the front panel are achieved by use of a continuous hinge. The WSA LED system,positioned behind the graphic panel,is visible only in the ON mode, Four colors of socket mounted LED's indicate equipment status and location. LISTINGS: UL AND CALIFORNIA STATE FIRE MARSHAL INITIATING POLARITY: POSITIVE/NEGATIVE OPERATING VOLTAGE 2,b,12,24 VDC INDICATORS SOCKET MOUNTED,HIGH EFFICIENCY LED'S; SUPPLIED AND SUPPORTED BY RED,YELLOW,GREEN AND ORANGE STANDARD DIMENSIONS: HEIGHT 181/4" 9Pimplex WIDTH 181/4" Simplex Time Recorder Co. GARDNER, MA01441-0001 U.S.A. See White Pages for Local Office WS61A ANNUNCIATORS OLU 00201004 Multi-Application Peripherals f3.Simplex and Accessories UL, ULC Listed Individually Addressable **MAPNET II° FM Approved* Communicating Devices FEATURES: • Individually Addressable Communications Over a Single Pair of Wires • System Displays Exact Device Location and Status ADDRESSABLE MANUAL • For Use with Simplex: FIRE ALARM STATION — 4100 Series Control Panels — 4100 Series Universal Transponders — 4120 Series Network Node Panels — 4020 Series Control Panels — 2120 Communicating Device Transponders • Initiating Devices, Notification Appliance Circuits, and Control Relays all Communicate Over the Same Wire Pair IV " ADDRESSABLE (Separate Power Required for Some BASE Devices) • Zone Adapter Modules (ZAMS) Provide Addressability to Conventional Circuits �qg • NFPA Style 4 or 6 Communications • Style 4 Wiring May be Either"T"Tapped or In/ PHOTOELECTRIC Out SMOKE DETECTOR • Dip Switch Address Selection INTRODUCTION: ZONE ADAPTER MODULE(ZAM) MAPNET II*`communicating devices individually annunciate exact identity and accurate status to the connected control panel. Applications include smoke detectors, manual fire alarm (pull) stations, heat j detectors, sprinkler flow switches (or any typical fire --- detecting device) and addressable control. New installation wiring is via twisted, shielded wire. a Performance is compatible with most retrofit wiring where unshielded and untwisted wire exist. SUPERVISED INDIVIDUAL SPECIFICATIONS: ADDRESSABLE MODULE (IAM) MAPNET II input......................24 to 40 VDC with Data ® � Current.............................................See Chart, Page 8 Address Means...........................Dip Switch, 8 Position - Temperature.......................32°F to 120°F (0°C to 49°C) Humidity..............85% Non-condensing Qa 86°F (30°C) ` The 2190-9172 IAM is UL&ULC listed,other listings pending. MAPNET II DEVICES " MAPNET is protected by U.S. Patent No.4,796,025. 01993 simplex Time Recorder co. Publication S2190-0012-6 7-93 PRODUCT DESCRIPTION SUPERVISORY ALARM I.D.* CURRENT CURRENT ZONE ADAPTER MODULE - MONITOR 2190-9153 1 Zone,Style D,Surface Cover 20 mA 90 mA 2190-9154 1 Zone,Style D,Flush Cover 20 mA 90 mA 2190-9155 1 Zone,Style B Surface Cover 20 mA 90 mA 2190-9156 1 Zone,Style B Flush Cover 20 mA 90 mA 2190-9157 4-Wire Detector Zone Surface Cover 20 mA 90 mA 2190-9158 4-Wire Detector Zone Flush Cover 20 mA 90 mA ZONE ADAPTER MODULE - CONTROL SIGNAL 2190-9159 Style Z Signal Surface Cover 15 mA 65 mA 2190-9160 Style Z Signal Flush Cover 15 mA 65 mA 2190-9161 Style Y Signal Surface Cover 15 mA 40 mA 2190-9162 Style Y Signal Flush Cover 15 mA 40 mA 2190-9163 DPDT Control Relay Surface Cover 10 ITA 40 mA 2190-9164 DPDT Control Relay Flush Cover 10 mA 40 mA ADDRESSABLE DETECTOR ELECTRONICS/IAM Current Draw Included w/Control Panel 2190-9172 Supervised IAM** 2098-9651 Detector Base w/Remote LED Output — — 2098-9652 Detector Base w/Alarm LED — — 2098-9744 Remote Alarm Indicator(LED) — — DETECTOR HEADS Current Draw Included w/Control Panel 2098-9202 Photoelectric Detector w/Heat — — 2098-9201 Photoelectric Detector — — 2098-9576 Ionization Detector — — ADDRESSABLE MANUAL FIRE ALARM BOXES*** Current Draw Included w/Control Panel 2099-9795 Single Action — — 2099-9796 Double Action/Breakglass — — 2099-9797 Single Action/Local — — 2099-9761 Double Action/Push-Pull — — 2099-9813 Flush Trim Plate N/A N/A 2099-9814 Surface Trim Plate N/A N/A 2975-9178 Back Box N/A N/A *For ULC listed products,add a"C"suffix(example:2098-9201 C). **2190-9172 is considered as 1.5 devices each for MAPNET II circuit loading.Refer to Simplex data sheet S2190-0018 for more information. ***For ULC listed products,add the suffix"C"if in English,"CF"if in French,or"CB"if Bilingual. Simplex Time Recorder Co. Simplex Building Systems Gardner,Massachusetts 01441-0001 U.S.A. Offices and Representatives Throughout the Wald FIRE DETECTION - SECURITY - COMMUNICATIONS - TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in US.A. Multi-Application Peripherals Simplex and Accessories S Non-Coded Manual Stations Wire Guard 2099-9800 At SURFACE-OR SEMI-FLUSH MOUNTING STATION W/2099-9800 WIRE GUARD -2 9 92 1992 Simplex Time Recorder Co. Publication S2099-0004 • • • Simplex Time Recorder Co. Simplex Building Systems Gardner,Massachusetts 0 U.S.A. Offices and Representatives Throughoutughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. A _ ru e-�g _ ==.1 13,,Simplex Fire Alarm Systems UL, ULC* Listed Communicating Devices FM Approved 4098-Series N.Y.C. BSA Approved TrueAlarMTM Sensors FEATURES: • Digital Transmission of Analog Sensor Values via MAPNET II®, Two-Wire Communications' • Automatic Environmental Compensation • Control Panel Sensitivity Selection y • Multi-Stage Alarm Operation • For use with Simplex 4100, 4020, and 4120 zy' Series Control Panels and Universal e Transponders ~ • Control Panels can Display and Print Detailed Sensor Information in Plain Language 4098-9701 SENSOR WITH • Automatic Alarm Simulation Test of Each 4098-9781 BASE Sensor • • Meets NFPA 72 Sensitivity Testing OPERATION: Automatically The alarm set point for each TrueAlarm sensor is • Sensitivity is Displayed in Percent per Foot determined at the system control equipment to be less (No Interpretation is Required) sensitive or more sensitive as the individual application • Peak Value Logging Allows Accurate requires. Alarm set points can be individually varied Analysis and Sensitivity Selection for each automatically by time of day to be more sensitive at Sensor night and less sensitive during daytime hours. System control equipment constantly monitors each TrueAlarm sensor's output and maintains a moving APPLICATION: average of these outputs. An alarm is determined by TrueAlarm smoke sensors can be ceiling or wall comparing the sensor's current actual value with the mounted. If ceiling mounted, the sensor should be as sensor's average value. Utilizing each sensor's average value as a continuously shifting reference point filters close as possible to the center of the room or hallway.lf out environmental factors which would otherwise this is not possible,the edge of the sensor should be at increase the probability of false alarms caused by shifts least 4 inches from any wall. If wall mounted, locate the in sensitivity either up or down. top of the sensor at least 4 inches and not more than 12 inches from the ceiling. The system will indicate when individual sensors need Sensor locations should be determined only after cleaning. Dirty sensors will automatically be careful consideration is made of the physical layout and annunciated at the control panel and the LED on the contents of the area to be protected. Refer to National dirty sensor's base will glow steadily. In an alarm Fire Alarm Code®, NFPA 72-1993. On smooth ceilings, condition, the LED on the alarmed sensor's base will spacing of 30 ft. (9.1 m) may be used as a guide. glow steadily and any base LED that was on steadily due to a dirty sensor will return to a pulsing indication. Up to 127 Sensors can be connected on a single pair of • wires to a MAPNET II interface panel. Unshielded wire rt ULC listed devices are designated with a„c"suffix may be used in retrofit applications.TrueAlarm sensors (example:4098-9201C). and other Simplex addressable communicating devices t Approved by the New York City Board of Standards can be Intermixed on the Same MAPNET II circuit. and Appeals under Calender Number 707-89-SA. "MAPNET is protected by U.S. Patent No.4,796,025. TrueAlarm is protected by U.S. Patent Nos.5,565,468,and 5,173,683. ©1993 Simplex Time Recorder Co. Publication S4098-0003-6 6-93 TrueAlarMlrm HEAT SENSOR FEAT •URES: • Self Restoring, Combination Rate-of-Rise and Rate Compensated Fixed Temperature • Low Profile • Low Thermal Mass • Sensor Sealed Against Rear Air Flow Entry • Listed to UL 521 Testing Standards • EMI/RFI Shielded Electronics • 2500 Square Feet of Area Coverage v; 4098-9731 HEAT SENSOR °. The 4098-9731 TrueAlarm Heat Sensor is a f , combination rate-of-rise/fixed temperature sensor with self-restoring operation. The sensor's small thermal mass allows an accurate up-to-date temperature reading of each sensor to be logged at the control 4098-9731 HEAT SENSOR panel. Rate-of-rise operation is selectable in either a W/4098-9781 SENSOR BASE 15°F (8.3°C) per minute or a 20°F (11.1°C) per minute rate of temperature rise. Fixed temperature sensing is entirely independent of the rate-of-rise operation and operates at 1350F (57.2°C). In a slow developing fire, the temperature may not increase rapidly enough to • operate the rate-of-rise feature. However, an alarm will 6 3/8" be initiated when the temperature reaches its rated (162mm)--►{� fixed temperature setting. T TrueAlarm heat sensors can be configured as a utilty T 1 1/4" device to monitor for temperature extremes in the range 1 7/8" (31.8mm) from 320F to 1580F (0°C to 2450C). This feature can (46.7mm) provide freeze warnings or alert to HVAC system i problems. WARNING: IN MOST FIRES, HAZARDOUS LEVELS OF SMOKE AND TOXIC GASES CAN BUILD UP BEFORE A HEAT DETECTOR WOULD INITIATE AN ALARM. IN CASES WHERE LIFE SAFETY IS A FACTOR, THE USE OF SMOKE DETECTORS IS HIGHLY RECOMMENDED. • Simplex Time Recorder Co. Simplex Building Systems Gardner,Massachusetts 01441-0001 U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. _True _ °Simplex Fire Alarm Systems UL, ULC* Listed Communicating Devices FM Approved 4098-Series/Photoelectric Duct Type TrueAlarmTM Smoke Sensors FEATURES: • UL Listed to Standard 268A • For Use with 4098-9701 Photoelectric al ; Sensor and 4098-9803 Baffle (Ordered Separately) �� � � • Communicates with Simplex Control Panel � � Models 4100, 4020, or 2120 CDT Over a Common Pair of Wires (MAPNET II®)** • Provides TrueAlarm Features:*** r: — Digital Communication of Addressable Analog Sensing s — Control Panel Sensitivity Selection — Sensitivity Maintained with Dirt Accumulation TRUEALARM DUCT HOUSING — Automatic Self Test 409$-9702; OR -9703 — Panel Indication of Dirty Sensors • • Two Versions Available: The 4098-9702, or the 4098-9703 Duct-mounted — 4098-9703, Two Wire Operation TrueAlarm smoke sensor provides detection of smoke — 4098-9702, Four Wire Operation (with present in the air conditioning or ventilating duct. The Auxiliary Control Contacts) TrueAlarm duct smoke sensor is expressly designed to • Pre-Aligned, Multi-Length Sampling Tubes prevent smoke recirculation in air handling systems. It is for Installation with Housing in Place not suitable to be used as a substitute for the building's area or room type fire detection devices. • Mounts to Round or Rectangular Duct Work The TrueAlarm duct smoke sensor uses a sampling • Integral LED for Power-On, Alarm or Trouble tube extended across the duct to continuously sample • Remote LED Alarm Output the air movement through the duct. The sampled air is • Remote Test Capability returned to the duct via an exhaust tube. The sampling • Optional 120 VAC Operation tube length is determined at installation and should extend across the full width of the duct. GENERAL: Where possible, the duct smoke sensor should be The TrueAlarm Duct Smoke Sensor is a smoke density mounted at least six duct widths downstream from any measuring device which has no self contained alarm set duct openings, deflection plates, sharp bends, or point. The Sensor Housing, with integral electronics, branch connections. To minimize smoke dilution, duct constantly monitors the status of the detachable Sensor smoke sensors should be located in each return air duct Head. Each TrueAlarm Sensor's output, which is a rather than in the main return air duct. function of smoke density, is digitized and transmitted to The 4098-9702 duct smoke sensor provides an the system's control every four seconds. Up to 127 auxiliary alarm relay with two"form C"contacts rated at Sensors can be connected on a single pair of wires to a 2A @ 28VDC or 120VAC resistive. This auxiliary relay Communicating Device Transponder (CDT) as a operates when the sensor reaches its alarm threshold. component part of a 2120 Multiplex System or a Or, when connected to a 4100 control panel, the relay MAPNET II Interface Module within a 4100 or 4020 Fire can be operated via software control, manually or Alarm Control Panel. Non-shielded wire may be utilized automatically, in response to input from other devices or in certain retrofit applications. zones within the system. • Complete instructions and a mounting template are ULC listed models are designated by a"C"suffix such as provided with the unit. The duct housing is mounted 4098-9702C. directly to the outside of a duct with widths from 8 inches MAPNET is protected by patent#4,796,025 to 95 inches wide. The housing may also be used on TrueAlarm is protected by US patent numbers 5,173,683 and round ducts with diameters of 24 inches or greater. 5,565,468. 1993 simplex Time Recorder co. Publication S4098-0004-3 2-93 • Simplex Time Recorder Co. Simplex Building Systems Gardner, Massachusetts 0 U.S.A. Offices and Representatives Throughoutughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. Multi-Application Peripherals Simplex and Accessories Photoelectric Smoke Detectors U L, U LC* Listed 2098 Series FM Approved (Projected Beam Type) FEATURES: • U.L. Listed to Standard 268 • Microprocessor Based • Temperature Compensated • Automatic Gain Control • Up to 350 Foot Coverage • Sensitivity Adjustment (6 Levels) • Front Bore Sighting for Ease of Alignment • Adjustable Optics • Auxiliary Contacts • Tamper Switch • Normal Status Indicator (Flashing Green LED) at Transmitter and Receiver • Alarm Indicator (Red LED) • Trouble Indicator (Amber LED) SPECIFICATIONS: • 2098-9207 • INPUT VOLTAGE: 18 to 32 VDC with a maximum PROJECTED BEAM DETECTOR allowable ripple of 4 Vp-p. • STANDBY CURRENT @ 24 VDC: Receiver=40 mA, DESCRIPTION: Transmitter= 20 mA. • RECEIVER ALARM CURRENT: Trouble = 40 mA, The Simplex 2098-9207 is a long-range photoelectric Smoke Detection = 60 mA. smoke detector consisting of a separate transmitter and receiver. It can be used to protect large areas such as • RANGE: 30 ft. to 350 ft. (10 m. to 110 m.) long gymnasiums, lecture halls, theaters, warehouses, 30 ft. to 45 ft. (10 m. to 13.7 m) wide. atriums, etc. • ADJUSTABLE OPTICS: ±900 horizontal, and± 100 The light source in the transmitter produces an infrared vertical adjustment. beam which is measured by the receiver to determine • SENSITIVITY: Field selectable for 20, 30, 40, 50, 60, obscuration caused by smoke.When the beam intensity or 70% beam obscuration. measured by the receiver falls below a preset threshold, • ALARM CONTACTS: Form "A"with contacts rated 1 an alarm output is generated. amp, 60 VDC maximum for DC resistive loads.Do not If dust builds up to the point where the signal has been use with capacitive or inductive loads. reduced by 50%, a trouble output is initiated. • TROUBLE CONTACTS: Form "B"with contacts rated Intermittent beam blockage during cleaning is ignored, 1 amp, 60 VDC maximum for DC resistive loads. Do and complete beam blockage causes a trouble output, not use with capacitive or inductive loads. not an alarm. • AUX. ALARM CONTACT: For"C"with contacts rated Simplified installation requires only one-time access to 1 amp, 60 VDC maximum for DC resistive loads. Do each unit as the transmitter may be installed and not use with capacitive or inductive loads. aligned using internal bore sights before the receiver is in place. The receiver has micro-processor control • TAMPER:Access door tamper switch is in series with allowing automatic calibration at the touch of a button. trouble contacts. The crystal locked transmitter signature allows the • SIGNAL DELAY: Fire = 30±2 seconds; Trouble = 20 receiver to distinguish the detection beam from all types • ±2 seconds. of EMI, including fluorescent, mercury and sodium • TEMPERATURE:The storage and operating range is lighting. 320F to +130°F (0°C to +54°C) The detector has an attractive beige case with black • MOUNTING:The units are designed to be mounted to face plate. 4"square or octagonal electrical boxes (not supplied by Simplex). •ULC listed model is 2098-9207C. 'D 1992 Simplex Time Recorder Co. Publication S2098-0053-3 7-92 LOCATION: DIMENSIONS: In all installations, good engineering judgement should prevail. Following are some general considerations: • • Do not use mirrors.The 2098-9207 should be installed with a clear line-of-sight path between the transmitter and receiver units. • The intended beam path should also be clear of 5.50" moving objects. (13.97cm) • Do not mount the receiver so that sunlight can shine directly down the beam path and into the unit. • For smooth, flat ceilings, mount the units so that the beam paths are between 4" and 12"from the ceiling. For a sloped or peaked ceiling, the beam path should be located within three (3) feet of the peak of the ceiling. • When two or more adjacent units are installed in the 3.75" 8.75" same area, alternating the transmitter and receiver (9.53cm) (17.15cm) locations is recommended. Reference Simplex publication PER-21-016 (574-666). • Stratification of air in a room may hinder smoke from reaching ceiling-mounted detectors. Stratification occurs when smoke, rising because it is warmer than the surrounding air, reaches a level where it is the same temperature as the surrounding air and does not rise to the ceiling. If stratification is considered a possibility, extra beam detectors should be installed where stratification is expected. • The beam should not pass close to heating,ventilating 1.25" or air-conditioning outlets where smoke might be (3.18cm) • circulated away from the beam.Avoid areas subject to normal smoke concentrations such as kitchens, and 11114.25" garages. (10.80cm) • Avoid areas subject to normal smoke concentrations such as kitchens, and garages. • Do not install units where normal ambient temperature is below 320F (O°C) or above 130OF (540C). • Reference NFPA 72E "Standard on Automatic Fire Detectors"for more detailed information on location and spacing of detectors. ENGINEER GUIDE SPECIFICATIONS: REMOTE INDICATOR/TEST UNIT Furnish and install where indicated on the plans The Simplex 2098-9816Ms a Remote Indicator/Test Unit, Simplex Photoelectric Projects Beam Detector, model to be used in conjunction with the 2098-9207 Beam 2098-9207. The detector shall be Underwriters' Smoke Detector. This unit will indicate the status of the Laboratories (UL) Listed #268. The detector shall be detector, (normal, alarm or trouble) provide test points microprocessor based, have automatic gain control and to check the detector calibration voltage, and can be temperature compensation. The separate transmitter/ used to test(via the key switch)the alarm function of the receiver shall be capable of long-range coverage of up detector. to 350 ft. (106M), and have six (6) sensitivity settings. The 2098-9816 is wired to the 2098-9207 Beam Smoke The detector shall include a normal status indicator detector via color-coded wire leads. For set-up, alarm (Green Flashing LED), an alarm indicator (Red LED), and trouble conditions, or calibration voltages, refer to and a trouble indicator(Amber LED).The detector shall Simplex publication PER-21-016(574-666). obtain its operating power from a Simplex UL Listed fire alarm panel. The operating voltage shall be 24VDC (Nominal). The detector shall have front bore sighting • for ease of installation. Simplex Time Recorder Co. Simplex Building Systems Gardner, Massachusetts Throughout the U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. 93,,Simpiex Time Control Systems Optional Features Clock Guards and Weather Resistant Clocks 12 1 10 ROUND CLOCK GUARD - 9 ® 3 Guard will protect surface or semi-flush clock 9", 12"or 15" round. For use in recreational areas. Finished in ,. 8 4 ,: zinc plate and recommended for indoor use. , 7 5 r • 231 SHOWNN OVER 15" ROUND CLOCK (CLOCK NOT INCLUDED) 0 10 MODERN CLOCK GUARD _ Provides same protection as the round wire clock guard ° 9 3 ° but presents a "Modern"appearance. Finished in zinc plate and recommended for indoor use. , g 4 4 7 5 , 0 2310-9822 • SHOWN OVER 12" ROUND SEMI-FLUSH CLOCK (CLOCK NOT INCLUDED) ©1993 Simplex Time Recorder Co. Publication S2310-0008-2 5-93 FOUR 1/4"MOUNTING HOLES,90'APART • CA OPRODUCT TYPE CLOCK DIMENSIONS I.D. NUMBER SIZE A B C 2310-9820 AE-10 15" 18 1/2" 5 3/8" 20" 2310-9821 AE-11 9"&12" 15 1/2" 5 3/8" 17" 45 45' 31/2" PRODUCT TYPE CLOCK I DIMENSIONS I.D. NUMBER SIZE A B — e & lus A 2310-9822 15F Semi Flush 19 1/4" 3 1/4" 2310-9823' 15S 12"&15" 19 1/4" 5 1/2" Surface • ti �BI FOUR HOLES 1/4"DIA. A WEATHER RESISTANT CLOCKS 72.. FEATURES: • 15" Round Surface Mount • Cast Aluminum Bezel and Back • Spun Aluminum Case • Shatterproof Plastic Lens {. 93 • Light Grey Finish TYPE 2310-7023 15" SURFACE CASE ^t ♦ 1 Simplex Time Recorder Co. Simplex Building Systems Gardner,Massachusetts Throughout the U.S.A. Offices and Representatives Throughout the World FIRE DETECTION - SECURITY - COMMUNICATIONS - TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. GENTEX fltushfG Ne w L o wer Opera ting Current SERIES 4" Electronic Horn HG or SHG Series Applications 4" low frequency electronic horn and horn/strobe that meets code requirements for supervised fire alarm systems. The HG/SHG series are quality electronic signaling devices that offer you both dependable evacuation signals and visual alarms or a combination of both by simple terminal wiring. The SHG series can also be SHG wired to have independent operation of both horn and strobes. (See wiring diagrams). This can be simply done by removing two jumper plugs located on circuit Approvals board. (See installation manual for details.) HG The HG/SHG series are easily field changeable ;5 ; from a steady low frequency alarm signal to a pulsingi UL =NBm low frequency alarm signal by simply removing a � ��e+naea jumper plug. Changing from steady tone to pulsing tone does not prevent reverting back to original tone Americans with Disabilities Act(ADA) at a later date. All units are shipped from the factory BFP in the steady alarm mode. BSA/MEA#412-91-E The HG/SHG series are designed to be used for CSFM#7135-569:115 both new construction or retrofit projects by easily NFPA 72G mounting to 4" electrical boxes or 2 gang old work UL 464 boxes (see back for details). Available Models All HGiSHG devices are UL 464/1638 listed for use with fire protective systems and are warranted for Light Rated Current 2 ears from the date of purchase. Effective Draw @Max Y p Model Operating Intensity in Operating Peak d8 Number Voltage Candela Voltage @ 10 ft. Standard Features HG124 10-30 - 21mA 100 Low frequency/penetrating output. sHG12L 10-16 17.8' 107mA 90 • Low current consumption 21 mA. (HG124) • Wide voltage range. sHG12H 10-16 100 235mA 90 • Screw terminals, separate in/out wiring option for SHG24L 21-30 17.8• 56mA 95 both horn and strobe. N 21-30 i 100 111mA 95 • Steady or pulsing tone. • Textured finish high impact plastic faceplate. •9.7 cd Qa 0"C • Wide variety of mounting options for new construc tion and retrofit applications. NOTE: 24VDC high candela strobes(H option)have PP a 200mA peak operating current @ 24VDC. • Supplied with beauty plugs to accommodate a variety of installations. WHEN PLACING AN ORDER:add the following to the end of the • Flush or semi-flush mounting without the need of a model number: trim plate. = Wall mount and Red faceplate • 100 candela strobe option SHG24H . Meets ADA �0`` Ceiling mount Beige faceplate p ( ) "P" = Plain(no lettering) requirements. t • UL 464/1638 listed for fire protective service. Ii MAO 1 I C A GENTEX SERIES Wiring Diagrams Architect & Engineer Specifications The alarm signal shall be Gentex model or approved equal and shall be listed by Underwriters Labora- A. HG HORN AM SHG SERIES POWERED IN PARALLEL, tories for Fire Protective Service. The model a w s s. H. +s s.H» shall also be listed with the California State Fire Marshal and the 0 0 0 0 Bureau of Standards and Appeals (NYC). CIPOLP The alarm signals shall produce a sound output of 90 dBA E0L' or greater peak as measured in an anechoic chamber. The alarm signal shall be capable of changing from a steady tone to pulsing without permanent alteration to the unit. B SHO SERIES WITH HORN AND STROBE PUMPED INDEPENDENTLY Maximum current consumption at 24VDC for alarm horn NUE:REMOVE CIRCUIT COVER HOU511413 AND REMOVE JUMPERS t AND 2. REPLACE COVER APO PROCEED TO WIRE HORN INTO CIRCUIT only shall not exceed 21 milliamps and the maximum current consumption for horn/strobe using 18 candela or below strobe UL uSTED ;O� +s s<�. +s H. shall not exceed 110mA @ 12VDC and 60mA @ 24VDC. For SUPERVSIEC those applications requiring the higher candela output strobe " 'T EOLA with alarm horn,the strobe output shall be 100 candela. The current consumption of the strobe shall not exceed 90 milliamps Eon° @ 24VDC, and combined with alarm horn shall not exceed 235mA @ 12VDC and 111 mA @ 24VDC. NOTE: POWER'S SUPPLIED TO DEVICES WHEN CONTROL PANEL IS LATCHED. The alarm signal shall be provided with screw terminals for in-out field wiring, the strobe shall be capable of operation independently after horn has been silenced. Mounting: 4"Square boxes w/brackets 21/8"deep minimum 4"square metal/non-metallic switch/outlet boxes 2'/a"deep minimum Gangable 2 gang switch/masonry outlet boxes 21/a"deep minimum SURFACE FLUSH WORKBOX O 00 00 00 QQ�0 QQ�0 QQ 0n0 00 00 _ 00 NOTE: Supplied with beauty plugs to accommodate a variety of installations. GENTEX CORPORATION Fire Protection Products: 10985 Chicago Dr. Box 310,Zeeland,MI 49464 616/392-7195,FAX:6161392-4219 c 117 CANDELA h STROBE PRODUCTS INC. Wheelock's most popular fire signals and speakers are STROBES now available with low current draw 117 Candela Series WM strobes ■ 117 candela flashing WINT Strobes for Americans With Disabilities Act (ADA) strobes for ADA WM3T WM1T applications applications. This is the same product line that has ■ Low current draw— earned the industry's highest overall ratings for quality just 0.088 amps and value in a survey of Fire Alarm ESDs and OEMs'. Description Wheelock's line of 117 Candela Strobe Products features one of industry's lowest cost ADA strobe solutions with state- ELECTRONIC SIGNALS of-the-art audible/visible combination signals such as high Series EH Electronic Strobe Horns output electronic horns and mini horns; uniquely versatile ■ State-of-the- peak dBart with performance nce aalswer installed cost obes electronic multitone signals and chimes; high performance Series AES Multi-Tone Signals ■ A choice of penetrating alarm tones voice evacuation speakers. ■ Multiple alarms with one device These products are described in this data sheet. For full • 106 peak dBA with 117 candela strobes specifications on these life safety signals, call us for the individual product spec sheets referenced in the table on the next page. Features ; Wheelock's alarm signals are the industry's preferred line of F � signaling products because they have a consistent record EH-0 EH-E ' of field proven reliability, because they comply fully with the AES-0 AES-E latest codes and standards, and because they provide big " Series-HORNS savings on every job with features like: Series MIZ Mini-Horns ■ Designed and priced specifically for in-the-roam applications • Lower current draw to minimize power supply and wiring ■ 90 peak dBA with 117 candela strobes costs. • Higher dBA output to enhance audibility—up to 106 peak CHIMES Series CH Electronic Strobe Chimes dBA at 10 feet. ■ Just one-tenth the current draw of conventional chimes ■ 83 peak dBA with 117 candela strobes • Convenient mounting to standard low cost electrical boxes. ET-1070 E-7070 • Fully assembled products to eliminate costly field assem- E-7025 ET-1080 bly. s; • Fast in-out wiring terminals to save on installation time. • UL Listed for Fire Protective Service. 'l '' CH-0 'The U.S.Fire Alarm Market:Characteristics and Trends.STAT Resources, Inc., 1991. SPEAKERS SUPPLIED AND SUPPORTED BY Series ET and Series E Strobe Speakers ■ For exceptional performance in emergency voice communications systems Simplex ■ 78 dBA at 1/8 watt to 96 dBA at 8 watts with 117 candela strobes Simplex Time Recorder Co. GARDNER, MA 01441-0001 U.S.A. See White Pages for Local Office WHEEL i BRANCH, N.J. 07740• (908) 222-6880• FAX 908-222-8707 NEPM MEMBER OTHER CATALOGS AVAILABLE UPON REQUEST Alarm Signals for Alarm Signals for Fire Signaling & Paging Industrial And Life Products • Safety and • Safety • for Telephone Communication Systems Systems �1 0 I •♦to. Luhe�cck !:.%C 273 Branchport Avenue Long Branch, N.J. 07740 (908) 222.6880 National Sales Office S1800-Rev.692 FAX: 908-222-8707 1-800-631-2148 Printed in U.S.A. EMKEHS SERIES whiee�ock,- ELEC7RCNI C HORNS THE SIGNAL SOURCESM AND S7ROBE HORNS Wheelock's new EH-Series Electronic Horns and EHS- Series Electronic Strobe Horns offer outstanding ad- vantages over conventional electromechanical horns in performance, packaging, and economical installa- tion. Standard broadband horn sound output is elec- tronically produced to provide up to 103 peak dB at 10 : feet with only 25 milliamps of current. The solid state design minimizes concerns about in-rush current and . ; RFI noise while providing high reliability and long op- v erating life unmatched by conventional horn designs. The compact package styles incorporate durable, sERIES high-impact thermoplastic construction to provide at- EH-E tractive appearance and convenient installation to EHS-E standard 4" backboxes. All models are available with factory attached strobes for visual signaling in unison with the audible alarm (EHS-Series) or independently (EH-WS Series). cc F , P'Fti d. _ 'eatures A a Solid state construction for unmatched performance, dependability, and economy compared to conven- tional designs. SERIES �► Broadband horn sound output with 103 peak dB for EH-D high audibility. EHS-D s Low current draw (0.025 Amps at 24 VDC) to min- imize power supply and wiring costs. * Wide input voltage range ensures system compati- Specifications bility and allows 24 VDC horns to work on 12 VDC also, using filtered or unfiltered voltage. The Alarm Signals shall be Wheelock EH/EHS Se- * Flush mounting to standard 4" backboxes without ries Electronic Horns and Strobe Horns. They shall need for separate trimplate. be solid state construction and shall produce a • Full range of attractive mounting options for indoor broadband horn sound output of 96 dBA (103 peak or outdoor installations. dBA) at 10 feet in an anechoic chamber. Horn cur- 1 High impact thermoplastic design for durable service rent shall be 0.025 Amps at 24 VDC (0.050 Amps and low shipping costs. at 12 VDC). Strobe current shall be 0.025 Amps at o Strobe horn models with single input for fast tandem 24 VDC (0.050 Amps at 12 VDC) for 12,000 peak wiring or dual inputs for independent operation of candlepower and 0.075 Amps at 24 VDC for 70,000 horn and strobe. peak candlepower. The strobes shall flash approx- • Choice of 12,000 or 70,000 peak candlepower imately once per second. Mountings for surface, strobes. semi-flush, flush, and outdoor installation shall be * Screw terminal inputs for convenient in-out wiring. provided with screw terminals for in-out field wiring a UL listed for Fire Protective Service. of up to #12 gauge wire. All models shall be UL Listed for Fire Protective Service. SUPPLIED AND SUPPORTED BY .q Simpiex Simplex Time Recorder Co. GARDNER, MA01441-0001 U.S.A. dENUE • LONG BRANCH, N. J. 07740 • (201) 222-6880 Ordering Information-1 Input Input Current dBA at 10 Feet Model Voltage (AMPS) 12 VDC 1 24 VDC Mounting Wiring Approvals Number (VDC) 12 VDC 24 VDC Typical Peak Typical Peak Options EH-DLI-R 12/24 0.015 0.025 90 98 96 103 B F ELECTRONIC EH-OL2-R 12 0.050 96 103 Fig 1 UL, CFM HORNS EH-ELI-R 12/24 0.015 0.025 90 98 96 103 A, C, D, E ULC, BSA EH-EL2-R 12 1 0.050 1 96 103 Model Input Input dBA at 10 Feet Peak Mounting Voltage Current Candle- 0 tions Wiring Approvals Number (VDC) (AMPS) Typical Peak power p EHS-DLI-W-VF-R 24 0.050 96 103 12,000 W—VF-LJ ELECTRONIC B, F STROBE HORNS EHS-DL2-W-VF-R 12 0.100 96 103 12,000 fig. 1 UL, CFM (Single Input) EHS-ELI-W-VF-R 24 0.050 96 103 12,000 A, C, D, E EHS-EL2-W-VF-R 12 0.100 96 103 12,000 Ham Strobe Model Input Input dBA at 10 Feet Input Input Peak Mounting Voltage Current Voltage Current Candle- Options Wiring Approvals Number (VDC) (AMPS) Typical Peak (VDC) (AMPS) power EH-0LI-WS-24-VF-R 24 0.025 96 103 24 0.025 12,000 B F EH-DL2-WS-12-VF-R 12 0.050 96 103 12 0.050 12,000 UL, CFM ELECTRONIC EH-EL1-WS-24-VF-R 24 0.025 96 103 24 0.025 12.000 ULC" STROBE HORNS A, C, D, E Fig• 2 (Dual Input) EH-EL2-WS-12-VF-R 12 0.050 96 103 12 0.050 12,000 EH-DLI-WH-24-VF-R 24 0.025 96 103 24 0.075 70,000 B, F UL, CFM EH-ELI-WH-24-VF-R 24 0.025 96 103 24 0.075 70,000 A, C. D, E BSA tOue to continuous development of our products, specifications and offerings are subject to change without notice, in "See Note 5 accordance with Wheelock, Inc. standard terms and conditions. NOTES: 1. Horn models with 12/24 input voltage can be used on 12 VDC or 24 VDC systems.All models are UL listed to operate over -20%of nominal input voltage and can be used with filtered or unfiltered(full wave rectified)voltage. 2. dBA is measured in an anechoic chamber with fast meter response (typical)and peak meter response(peak). 3. Standard strobe horns have white lens with red"Fire"lettering. UL rated light output 1.5 candela for 12,000 candlepower and 15.0 candela for 70,000 peak candlepower. 4. Single input strobe horns are recommended for fast wiring when horn and strobe operate in unison on continuous alarm systems.Dual input strobe horns are recommended for coded alarm systems and for independent control of the horn and strobe. 5. Approvals:UL = Underwriters Laboratories,CFM = California Fire Marshal,ULC = Underwriters Laboratories of Canada(24 VDC,0.050 A strobes for all ULC strobe horns), BSA = NYC Board of Standards and Appeals. Mounting Options (All models shown with optional strobe. Backboxes and plates ordered separately.) Wiring A. SURFACE B. SURFACE C. SURFACE FIG. 1 O a - ®� 1 ,� �� �' (STROBE)HORN iql�L1prt1��'�,� 9 a AP PreceOing Next DBB Signal Signal SERIES 0 DBB SERIES SBB SERIES 3 or FRCP or EOL it EH-E EH-D EH-E EHS-E EHS-D EHS-E D. OUTDOOR E. SEMI-FLUSH F. FLUSH FIG. 2 a 4'sq. x 2Va'deep backbox WBB ��l STROBE HORN Icy Next strobe� M Strode or FACP or EOL ; Preaomg Next is ,� ( SERIES SERIES �' 'j Hgm H.QM SERIES EH-E SFP EH-0 \\ or FACP o,EOL EH-E EHS-E EHS-D EHS-E 4'Sq. x 1112'deep backbox WHEELOCK, INC. • 273 BRANCHPORT AVENUE• LONG BRANCH, N. J. 07740 • (201) 222-6880 FAX: 201-222-8707 S1400-Rev. 1090 Printed in U.S.A. Multi-Application Peripherals Simplex and Accessories UL Listed Bells, Chimes, and Buzzers FM Approved 2901 Series Bells FEATURES: • Modular Design • Low Operating Current • AC and DC Operation • Vibrating and Single Stroke • Red or Beige Finish • Standard 4" (10.2cm) Outlet Box Mounting • High Output Level BASIC 4" (10.2cm) BELLS DESCRIPTION: Simplex heavy-duty vibrating and single-stroke bells are designed to provide a complete choice of mountings, design configurations, and operating voltages at a minimum cost. The basic bell mechanism is available in standard voltages from 4 to 120 VAC and 1.2 to 24VDC. Each bell consists of a mechanism and either a 4" (10.2cm), 6" (15.2cm) or 10" (25.4cm) gong. Mounting hardware for surface, flush, semi-flush, weatherproof BASIC 6" (15.2cm) BELLS and concealed conduit mountings, are available. The bells are gasketed and are easily adapted to weatherproof design by adding a cast backbox m equipped with conduit bosses on the top and bottom for 1/2" (1.2cm) conduit entrance. Bell guards, which cover the entire unit are also available for any size bell. The 2905-9953 yard hood is designed for use outdoors to mount a bell mechanism a with bell gong on a weatherproof box. It is designed to allow a maximum amount of signal level to radiate from the hood outwards, yet protect the audible device from the elements. (Refer to Data Sheet S2975-0005). T BASIC 10" (25.4cm) BELLS ACCESSORY SPECIFICATIONS: PRODUCT I.D. DESCRIPTION DIMENSIONS 2905-9903 Semi-Flush Wall Plate for 4"Box,Red 6"H x 6"W x 3/16"D 2905-9904 Semi-Flush Wall Plate for 4"Box,Beige (15.2 cm x 15.2 cm x 0.238 cm) 2905-9953 Yard Hood,Beige 13 3/16"H x 13 3/4"W x 6 7/16"D (33.5cm x 34.9cm x 16.35cm) 2975-9006 4"Surface, Indoor Knockout Box,Red 4"H x 4"W x 1 1/2"D 2975-9007 4"Surface, Indoor Knockout Box, Beige (10.16cm x 10.16cm x 3.81cm) 2975-9008 Surface,Weatherproof Box, Beige 4 9/32"H x 4 9/32"W x 2"D 2975-9009 Surface,Weatherproof Box, Red (10.87cm x 10.87 cm x 5.08cm) 2975-9909 Concealed Conduit Adapter, Red 6"H x 6"W x 3/16"D 2975-9910 Concealed Conduit Adapter, Beige (15.2cm x 15.2cm x 0.238cm) % Simplex Time Recorder Co. 13Simplex Building Systems Gardner,Massachusetts 01441-0001 U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL THE SIGNALSOURCEsM Wheelock's strobe signals offer maximum reliability and efficiency for effective visual signaling in fire and life safety applications. A xenon flashtube with solid state 1 circuitry enclosed in a rugged polycarbonate lens elim- inates the delicate filaments used in incandescent light '` signals and provides significantly greater light intensity . with lower current requirements. Models with 12,000 C �� (0.6 waft)and 70,000(1.8 watts)peak candlepower are r ' I offered. Flush models mount directly to standard single 's gang or 4" square backboxes and surface models can , � 1 be used indoors or outdoors.All models are compatible ; with DC supervision of alarm lines and satisfy the latest code requirements for visual signaling. C. SERIES E E j Features WST e UL Listed for Fire Protective Service. wHT e High intensity output with minimal power input. Ste, WH3T SERIES e Compact solid state design with long operating life WS1T e Choice of input voltages and light intensities. WHIT a Convenient mounting to standard backboxes. e Compatible with DC supervision of alarm lines. 6 Screw terminals for secure in-out field wiring. s Attractive red textured finish to enhance appearance SUPPLIED AND SUPPORTED BY and durability. 93,Simplex Simplex Time Recorder Co. GARDNER,MA 01441 0001 U.S.A. See White Pages for Local Office i Specifications i The visual signals shall be Wheelock Series WS/WH Strobes or approved equal. They shall be UL Listed for Fire i Protective Service and shall produce 12,000 peak candlepower with 0.6 waft input (1.5 candela) or 70,000 peak k candlepower with 1.8 wafts input (15.0 candela) at approximately one flash per second with continuously applied voltage. Rated voltage range shall be ±20% for nominal 24 VDC and 12 VDC models. The xenon flashtube and associated circuitry shall be enclosed in a translucent white polycarbonate lens with the word FIRE inscribed on the lens. WS/WH models shall mount to recessed 4" square backboxes; WS1/WH1 models shall mount to recessed single gang backboxes and WS3/WH3 models shall surface mount to Wheelock's indoor BB backbox or outdoor WBB ! backbox. All DC models shall be polarized and all AC models shall have a blocking capacitor for DC supervision of alarm lines. Screw terminals shall be provided for in-out field wiring. Product finish shall be textured red enamel. i I t WHEELOCK, INC. • 273 BRANCHPORT AVENUE • LONG BRANCH, N. J. 07740 • (201) 222-6880 • FAX: (201) 222-8707 Ordering Information t 12,000 Peak Candlepower 1.5 candela 70,000 Peak Candlepower 15.0 candela Model Input Rated Model Input Rated Plate Mounting Number Voltage Current Number Voltage Current Color Wirin Options Approvals WST-I2-FR 12 VDC 0.050 WHT-I2-FR 12 VDC 0.150 Red UL, ULC,' WST-24-FR 24 VDC 0.025 WHT-24-FR 24 VDC 0.075 Red Fig. 1 C CFM, WST-115-FR 115 VAC 0.018 WHT-115-FR 115 VAC 0.060 Red Fig. 2 BSA,' BFP WS1T-12-FR 12 VDC 0.050 WHIT-12-FR 12 VDC 0.150 Red WS1T-24-FR 24 VDC 0.025 WHIT-24-FR 24 VDC 0.075 Red Fig. 1 D WS1T-115-FR 115 VAC 0.018 WHIT-115-FR 115 VAC 0.060 Red Fig: 2 UL, CFM, WS3T-12-FR 12 VDC 0.050 WH3T-12-FR 12 VDC 0.150 Red BSA,' WS3T-24-FR 24 VDC 0.025 WH3T-24-FR 24 VDC 0.075 Red Fig. 1 A,B BFP WS3T-115-FR 115 VAC 0.018 WH3T-115-FR 115 VAC 0.060 Red Fig. 2 tDue to continuous development of our products, specifications and offerings are subject to change without notice, in accordance with Wheelock, Inc. standard terms and conditions. 'Note 7 NOTES: 1. All models have white lenses with FIRE lettering. 2. All mounting plates are finished in textured red enamel. 3. All models have screw terminals for in- out wiring. 4. All models produce approximately one flash per second with continuously applied rated voltage. 5. Voltage range is :L20% on all 12 VDC and 24 VDC models using filtered or unfiltered (FWR) input. 6. Series-WS minimum effective intensity is 1.5 candela and series-WH is 15.0 candela per UL standard 1638. 7. Approvals: UL = Underwriters Laboratories, ULC = Underwriters Laboratories of Canada(series-WS rated 24 VDC at 0.050 A), CFM = State of California Fire Marshal, BSA = New York City Board of Standards and Appeals(series-WH), BFP = City of Chicago. Mounting Options (Backboxes ordered separately—specify color) A SURFACE B OUTDOOR C FLUSH D FLUSH P- 0 SERIES 'o j(D SERIESVAdapter Standard WS3 1, ° WS1 single gang SERIES WH3 WH1backbox WS3ggWH3 '�� Standard 4"square ° SERIES backbox WS plate WH supplied Wiring Fig. 1(DC STROBES) Fig. 2(AC STROBES) DC STROBE AC STROBE Preceding Next Preceding Next Strobe Strobe Strobe Strobe or FACP or EOL or FACP >_ or EOL WHEELOCK, INC. • 273 BRANCHPORT AVENUE • LONG BRANCH, N. J. 07740•(201)222-6880 • FAX: (201) 222-8707 S0800-1090 Printed in U.S.A. Multi-Application Peripherals Simplex and Accessories UL Listed Audible/Visible Appliances (4903-Series) FM Approved Visible Only Appliances (4904-Series) FEATURES: R E • UL Listed per Standard #1638 • Xenon Flash Output AUDIBLE/VISIBLE • Low Strobe Current y APPLIANCE W/FRONT MOUNTED HORN • Controlled Flash Rate • Enlarged Lens Design : • Snap-Together Assembly " A • AN Mounts on Standard 4"Square Electrical Outlet Box • Surface or Semi-Flush Mounting • Wall or Ceiling Mounting AUDIBLE/VISIBLE W • Tamper Resistant Lens APPLIANCE CEILING ' R� • Polarized for System Compatibility MOUNTED a, a � r FIRE DESCRIPTION: - The Simplex Audible/Visible Appliances provide a common enclosure for the Fire Alarm system audible and visible alarm notification appliances. The visible AUDIBLE/VISIBLE APPLIANCE W/ appliance snaps into and becomes an integral part of FRONT MOUNTED SPEAKER the housing. The audible appliance is ordered separately and added to the housing. s The A/V appliance may be mounted surface or semi- flush.The housing has been designed to accommodate front mounted horns, bells, chimes and speakers. " The lens for the visible section is clear and is supplied with the word "FIRE" in red letters. A plain lens is also available. The lens has excellent side viewing visibility. F I`"- The strong Lexan lens is provided with locking tabs to ' I resist tampering. VISIBLE ONLY APPLIANCE R If desired, the front bezel,which is constructed of tough UL Listed Noryl, may be inverted so the lens will appear °E E', below the audible appliance. The lamp assembly incorporates a built-in reflector for more efficient light propagation.Simplex A/V appliances incorporate a Controlled Flash Rate circuit enabling all devices on a single circuit to flash at a consistent rate. ! All 24VDC appliances are polarized for operation on the electrically supervised notification appliance circuit(s)of Simplex control panels. AUDIBLE/VISIBLE APPLIANCE Simplex Audible/Visible units are designed for standard W/WIRE GUARD 4" square electrical box mounting. Visible Only appliances mount to single gang boxes. r,1992 Simolex Time Recorder Co. Publication S4903-0001-6 5-92 DIMENSIONS: / �(6.98cm) (5 l,Q 5Yi (14.60cm) (20.95cm) 15/16" -+� (2.38cm) SEMI-FLUSH MOUNTING OPTIONS: 6"or 10" Bell Ab Audible/Visible d Assembly 4"Square jillik 1 Elec.Box* O ® O O O O4"Bell \\ O O o00 • C Q Q � 4"Square Elec.Box* * Not Su B p AudiAudible/VisibleIced Supplied y Simplex. Assembly Chime Simplex Time Recorder Co. Simplex Building Systems Gardner, Massachusetts Throughout the U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY - COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication.and are subiect to chance without notice Printed in U.S.A. E-8112-022-010 R A D I O N I C S Specifications Sheet Omegalarm D8112G2 Control/Communicator Logger, Local Printer, Comex, Skeds, and Modem H Reporting meowvyj,t%� - �oa112 EGA� `� : - Ov�""t ��,,,►�°•pr, ��� y��u.+ ..++ © ate*�i Ct�t \�\p�{�Op'\ M� lf•� V\tII O1� r�' ra^�' �SOO •A ,9 �JJ J i The Omegalarm D8112G2 Control/Communicator 75-04918-000-D 2/89 © 1988-1989 Radionics, Inc. E-8112-022-040 Accessories for the D8112G2 D8112G2 Specifications D360 Command Center Voltage Input Remote arming station with LED annunciator display. Pn.mary: 16.5 VAC 40 VA class 2 plug-in transformer Secondary: 12VDC 6AH rechargeable battery D1252 Command Center Current Requirements' Remote arming station. Features an alpha-numeric 1CLIje: 150 mA annunciator display and speaker capable of several Transmittina: 250 mA(maximum) audible tones. D8114 Quad Serial Output Module Auxiliary Power Output* Has four serial data outputs. Provides isolation 1 Amp at 10.2 to 14 VDC (continuous supply) between devices connected to the D8112's terminal Switched Aux Power: Current drawn from auxiliary 31. Eliminates possible interference caused by voltage supply, may be interrupted (switched off) tampering with serial data wiring. Each output momentarily from the command center. supports serial data devices in the same manner as Alarm Power Outputs' the D8112's terminal 31. Because the D8114 has Steady or Pulsed: 2 Amps at 10.2 to 14 VDC four outputs, four wire runs using maximum wire supplied on alarm. Output may be steady or pulsed. lengths can be connected. Altemate Alarm: Current drawn from alarm power output (2 Amps at 10.2 to 14 VDC). D8129 Octo-Relay Module Silent Alarm: Current drawn from alarm power output Provides eight Form 'C' dry contact relay outputs for (1 Amp at 10.2 to 14 VDC). a variety of programmable responses to alarm, trouble and other system conditions. The D8129 can ' To comply with U.L. 985 and 865 standards for fire alarm be operated on a time-scheduled basis using Skeds, installations, the total power output for the system during manually operated from the D1252 Command alarm conditions must be limited to 1400 mA unless a Center, and remotely operated using the D9300 D8132 is installed to provide an additional 1400 mA. Do Remote Account Manager. not exceed individual Terminal outputs specified above. Telephone Connections D8131 Printer/CRT Interface Module One TelCo Line: RJ31 X or RJ38X jack can be Provides either RS232 or current loop output for interfaced with the D8112. RJ38X allows phone printer and/or CRT for on-premises recording of cord supervision. Phone line supervision for either Logger events. (Uses D8135 Cable) jack is programmable. Two TelCo Lines: Install Omegalarm D128 Dual D8150 Local Printer Phone Line Switcher for two phone line service. Connects directly to the D8112G2 via J26 connector Supervision supplied. to provide printed copy of events recorded in Logger. (Uses D8134 Cable) Compatible Accessories D8160 Printer Paper Zonex (Zone Expansion D8125, D8126, D8128) Refill paper for D8150 Local Printer (5 rolls) D122 Dual Battery;.Harness b125 Powered Loop Interface Module D5100 Bar Code Programmer D127 Reversing Relay Provides on-site programming for D8112 and other D128 Dual Phone Line Switcher Radionics products. D129 Dual Class A initiating Circuit Module D9300 Remote Account Manager D192 Bell"Circuit>Supervision Module Provides Remote Programming capability for D8112 D268/D269 Independent Zone Control and other Radionics products. Also used to retrieve D279`Independent Zone Control events stored in D8112's "Logger" memory. D360 Command Center(LED display)D8121A orD8122 Derived Channel S.T.U. D8130 Release Module D8132 Battery Charger Module M801 (6");'`M802 (8"), M803 (10"), M806 (10")Bells D8103 Universal Enclosure WM09fFire Enclosure D8108A Attack Resistant Enclosure Radionics 1800 ABBOTT ST., P.O. BOX 80012, SALINAS, CA 93912-0012 F-0360-020-010 R A D I O N I C S Omegalarm D360 Command Center Specifications Sheet 04 r , ,- i J 3's 1. � Description The Omegalarm D360 Command Center is an attractive surface-mount arming station designed for use with the Omegalarm D8112 series Control/Communicators. This economical keypad can control up to seventeen command functions of the 8112 security system, including: instant perimeter arming, delayed perimeter arming,partial perimeter arming, shunting of selected zones, and much more. The new designer styling of this arming station forms a matched set with the Omegalarm D1252 Alpha H Command Module, giving you a very professional, integrated system approach to your installations. Installing the D360 is a "snap." A standard four-conductor wiring connection from the keypad to the control/communicator is cost-effective to run, quick to connect; and mounting the D360 is easy. This low profile surface-mount unit gives the appearance of a flush-mount installation and all you do is attach it to the wall. Just two screws and it's mounted! And because it is a surface-mount keypad, it may be located virtually anywhere in an indoor environment. In fact, the D360 is so easy to install that the instructions provided with the unit are written on one sheet. Of course, also provided with the D360 is a User's Guide to the operation of the D360 and the Omegalarm security system. The D360 is fully compatible with other four-conductor keypads used with the Omegalarm D8112. A total of five of these type keypads may be installed in the Omegalarm 8112 system, each wired in parallel, using the same wiring configuration as that of the D360: data in,data out, +12VDC and common. The Display To keep you informed of security status, the D360 uses an energy efficient display panel. High brightness LEDs provide status of the system's arm/disarm condition, individual protective zones, AC power and command mode. Zone status is indicated in four ways: fast flash for zone alarm memory,slow flash for shunted zone, steady light for faulted zone and light off for normal zone. System arm/disarm status is displayed by three LEDs which indicate whether the control is armed with or without delays, and which part of the system is armed. The AC power LED keeps you informed- of operating power supply, and the command mode LED lights up every time the COMMAND key is pressed. 75-04586-000-A 11/86 F-0360-020-020 The Digital Keypad & Warning Tones The model D360 communicates to the user several system conditions without ever using its display. Friendly signals like lighting the keypad and pulsing a beeper during entry delay,lighting the keypad and sounding a beep whenever a key is touched, and sounding a double beep if you touch a key while a zone is faulted;these extra features are standard on the D360 Command Center. Other standard features on the D360 include the COMMAND key,which controls programmable options of the D8112 security system. The COMMAND key allows several system functions to be controlled from the D360 just by pressing two or three keys. Since system commands are programmable,you may offer your customers exactly what they need. Programmable Function Keys The D360 also includes four function keys(A,B,C,and D). These keys allow complete system command functions to be programmed into a single key. The benefit here is the ability to touch one key for instant command activity. No more memorizing commonly used command combinations,merely touch a key and your wish is the system's command. If that is too easy to control, you may program a security combination into the system, making the function keys and the COMMAND key off limits without prior use of this special combination. Like virtually everything else in this programmable system,the choice is yours. COMMAND Functions Controlled by.the D360 Command Center COMMAND 1 Master arm the entire system with entry/exit delays COMMAND 2 Arm the perimeter without entry/exit delays COMMAND 3 Arm the perimeter with entry/exit delays COMMAND 4 Reset sounders,reset alarm memory COMMAND 4 1 Transmit test report COMMAND 4 2 Transmit system status report COMMAND 4 3 Enable remote programming COMMAND 4 4 Local system test COMMAND 4 7 Reset detectors COMMAND 5 Keypad combination change COMMAND 6 Perimeter watch mode COMMAND 7 Special(medical)alert (silent or local alarm) COMMAND 8 Partially arm the perimeter COMMAND 9 Police alert(silent or local alarm) Other security system features controlled by the D360 Command Center include duress combination,selective zone shunting, and force arming the system. Specifications Dimensions: Base -- H 4.56" W 8.15" D .816" Cover-- H 4.30 W 8.12" Color: Warm gray. Power: Nominal 12 VDC supplied by the Control/Communicator. Current Required: Idle-- 25mA armed or disarmed. Maximum-- 90mA with keypad lit and warning tone"on." Wiring: Standard four-conductor cable supplies data-in,data-out,+12VDC and common. Radionics 1800 ABBOTT ST., P.O. BOX 80012, SALINAS,CA 93912-0012 CUSTOMER SERVICE: (800) 538-5807, IN CA (800) 682-9865 i r Life Alarm C4Sim.$,, 1e Multiplex Systems p Mint e y r�a Options I UL Listed 2190 Series C CRT/Keyboard FEATURES: • 14" (35.5cm) Diagonal Tilt/Swivel Monitor --- • 25 Display Lines • Paper-white P-188 Phosphor Non-glare Display • Detachable Keyboard • Operates from CPU's RS-232-C Output • UL 864 Listed Supplemental Equipment • Used with 2120 and 4100 Systems' 1 " { l ! lrI rr fT7 r r r It' rI f r r r r 1 r tt DESCRIPTION/OPERATION: t 2190-9042 y g The 2190 series CRT/Keyboard is designed to provide a visual indication of system events at a remote ' location. The keyboard provides a means to communicate with the CPU from a remote location. The CRT/Keyboard operates from a 2120 CPU RS-232- C port using a 3-conductor cable. This cable accommodates data transmission between the CPU SPECIFICATIONS: and the CRT. This connection allows transmission of Power Requirements .............. 120VAC, 50/60 Hz, any status changes to be displayed on the terminal. 0.6 Amps s The keyboard can be used to enter or alter time control Temperature............................ 32'F to 120°F or cycling programs, or to enter field programmable 0'C to 49°C control-by-event commands. System status reports can Humidity.................................. 85% Non-Condensing also be displayed on the monitor at the operators Shipping Weight......................25 lbs. (11.34kg) request. Dimensions — CRT................ Height: 12.5" (32cm) ; Through separate keystrokes the keyboard is also Width: 12.7" (32.2cm) capable of providing: Alarm Acknowledge; Ctrl-A, Depth: 12.5" (31.8cm) Signal Silence; Ctrl-S and Detector Reset Ctrl-D. i Dimensions — Keyboard........ Depth: 6.75" (17.14cm) Also available is an internal tonealert which may be Width: 18.625"(47.3cm) programmed to sound upon receipt of an acknowledgeable alarm or trouble. E * For 4100 Information Refer to Data Sheet S2190- j 017. 1991 Simpiex rime Recorcer Co. Publication S2190-0016 9-91 i TYPICAL INSTALLATION: COMMUNICATIONS CIRCUIT TO SYSTEM TRANSPONDERS j MAXIMUM DISTANCE: 2,500 ft(762m) - — L @ 1200 BAUD (18 AWG TWISTED SHIELDED o.9aS 3-CONDUCTOR CABLE) 120 _ VAC r' r r r r r r r r t rr� t r r r r i j t t r r r r r r r ► r t �� 2120 CPU r t 2190-9042 120 VAC i i t I r i Simplex Time Recorder Co. It Simplex Gardner, Massachusetts 01 0001 U.S.A. j Time, Fire Alarm, Security, Sound and Nursee Call Systems , Offices and Representatives Throughout the World i All soe&ications and other information shown were current as of publication.and are subject to change without notice. Printed in U.S.A. Life Alarm' ®Simplex 2120 Multiplex UL Listed Options FM Approved 2190-9038 Printer FEATURES: • Provides hard copy record of system events at a remote location • Operates from a 2120 or 4100 RS-232-C Output • Transient protection on RS-232-C input and AC input GENERAL: The 2190-9038 printer is designed to provide a hard 2190-9038 copy record of system events at a location remote from • the 2120 or 4100 Central Processing Unit (CPU). SPECIFICATIONS OPERATION: VOLTAGE 120 VAC The 2190-9038 printer operates from the CPU's RS- _ - 50/60Hz 232-C port using a 3 conductor cable. The CPU POWER 0.7 Amp transmits data to the printer whenever there is a status change within the system. This Bi-directional printer PRINT 200 CPS utilizes a Dot Matrix Mechanism. SPEED MULTIPLE Yes COPY PAPER: WEIGHT 12.8lbs. (5.8Kg) The 2190-9038 printer is equipped to utilize up to 10.1" OPERATING 32' to 120°F cut sheet or 10" (pin to pin) fanfold paper. No storage TEMPERATURE (0° to 49°C) provisions are provided. --- ----- - - 85% HUMIDITY Non-Condensing HEIGHT 5 RIBBON: (14.2cm) A (617-705) cartridge type ribbon is employed for ease -- - - - -- 16.5" of replacement. WIDTH (42.Ocm) 13.3" DEPTH (33.8cm) (617-705) 3 Million RIBBON Characters CARTRIDGE COLUMN 80 Character WIDTH C 1992 Simplex Time Recorder Co. Publication S2190-0013-1 9-92 • RS-232-C#18 AWG twisted shielded 3 conductor cable IIIl1UI�lU�IUI�AUIf)fAI�UM�I l 120 - VAC :..r...pip" — � f I 'y { ffiAffiffia ffi �mjr1R00W 4�*' 0 120 .� VAC CPU • 2190-9038 Communication Maximum distance circuit to from CPU transponders •2,500 ft (762MM) @ 1200 baud • Simplex Time Recorder Co. Simplex Building Systems Gardner,Massachusetts Throughout the U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. • COMPUTER CENTERS, FAX MACHINE • STANDS, AND OFFICE MACHINE CABINETS ftim 5W4" •-Functional stands and - pier.. r • - cabinets hold 71 necessary equipment -used in offices z , Casters provide 'portability for easy moving.to venous - locations No:SW605r •-Equipment shown on ' pe «< rr stands and cabinets ~ Pa$asketch P1 V not included t _ No.5W607 ° �. Office Machine ?4• _ Cabinet - SHA ❑ander•,on hickey 90 da r -� >� rTTy warrsatsd fo request See No.SW604:: � Site inside h� Computer Center t - - - -Feature Copy Counter Contrc i _ MEW fTEM Captes per A inute: irg Drum Cartridge_ bg Toner Cartridge _ No.5W603 ) No.3W822. ' Fax Cabinet Stand xwTonerlDeveloper . Office Machine. r ' IM Original Si-Stand No.5W602 Si ze: Open Shelf Fax Stand }um Re - placement B .,, hlarge/Re�duc=Ratio Computer Center.Create your own com- copiers, paper shredders, or any heavy and a telephone,plus enough extras d Tray Capacity: pletely portable data processing center office machinery. Box-tube inside shelf to organize papers and forms pnor, d Tray Sheet Adjw with this handy computerlprinterlkey- adjusts in 2"increments to accommodate faxing.2"twin roller casters(2 with board holder. Adjustable sliding key- machine or copier supplies. Features ing brakes) and grommeted hole in_ ensions W x D x H board shelf may be arranged at perfect sliding doors and legs with level guides shelf to accommodate cords.Press ber of copies rema. sit-down height.Three typing heights(25", that insure a stable, flat surface. No. bels included for identifying slots.._ s 26", 27") give legs proper clearance and 3W822 has.black finish, No. 3W823 has bottom holds bulk paper and office` t allow easy access to keyboard.Keyboard parchment finish. Overall size:36 wide x plies.'13"space between modular s °P c°Piers prod stays tucked away and protected while 29 high x 26" deep. Anderson Hickey and,bottom shelf. Overall size:30 tofors simply byct not in use or during transport Printer brand.(MS2636). 28%high x 20"deep.Beige finish.S cartridges;blac i shelf is adjustable from 14", 16", and 18" disassembled.Bretford brand(F Veen available.T and has slot for bottom-feed printers. Shp 3 rL 88.Black finish Machine Stand. -not included,o, Locking knobs on both slidin shelves Shpg.wt 88.0 lbs.List...........$1".0. lb. List$2t Facsimile Stand.Shpg c feedin g Each......... ..$166.36 lbs.List$237.00.Each.........,. feeding,-sheet keep them in position.Shelves slide easi- .''''''''''''' second side of a t ly on adjustable chrome plated steel rods *No. 3W823. Parchment finish Machine Facsimile Cabinet Stand.Top su automatic Paper feeds from bottom shelf into op- Stand. Shpg. wt. 88.0 lbs. List $233.00. commodates a fax machine and=. up time is expos,0 se tional paper catch basket No. 5W605 be- Each.........................$166.36 phone, while leaving room to sod' i150 watts maxim[: low. Top shelf: 33" high. Bottom shelf to Office Machine Cabinet.For small copiers organize papers. 4 modular shelves, y- . be divided into a maximum of 12 slots qbg Com floor:60.Overall size:24 wide x 33 high x - and laser printers. Heavy-gauge electri- minimum of 4 slots. Shelf divid pact De. Y 18" deep. Shipped disassembled. Beige cally welded construction,with full-width interchangeable to fit application copies. Drum c. finish.Bretford brand(EC4). . fixed interior shelf for holding plenty of press-on labels is.included to id ement cartridgf No. 5W604.t Computer Center. Shpg. wt extra paper.Hidden ball-bearing casters slots. Locking cabinet doors provibs brand(Z52). 48 lbs.List$232.00.Each...,..'-.$177.48 for ports ility.Cabinet opening:16 wide x cure storage system for supplies 19"high.Overall size:20 wide x 24i/s high x cessories. Irvo keys included Doo �9 Desktop cop Paper Catch Basket. Wire-formed steel 20"deep.Ivory finish.Shipped assembled. on full-length piano hinges with pying•Drum cart: shelf attaches to back of compufer"center Bretford brand(FC2020). plastic handles. 2"twin roller ent cartridges to catch all printouts.-Overall size: 24 `No.SW607.t Machine Stand.Shpg.w.50.0 with brakes)and grommeted hole is brand(Z57). - wide x 7 high x 13'deep.Bretford brand lbs.List$222.00.Each...........$169.83 shelf for cords.Cabinet interior.28 (EC4PCB). 10 high x 19"deep.Overall size:30 470 Desktop Cop No.5W605.t Paper Catch Basket Shp .wt.- Open Shelf Facsimile Stand. 3 modular 281s high x 20"deep.Beige finish. largment.Reduce P gg mail slot"shelves which can be divided b 75to94%ofthei: ��• 3.3 lbs.List$34.50.Each... .... .$26.40 into a maximum of9 slots or a minimum of disassembled.Bretford rand(F Office Machine Stand. Sturdy stands for 3 slots for sorting faxed information.Top No. SW603.t Cabinet Stand. Shpg 'elector. to um c. ! use with fax machines, postage meters, provides enough room for a fax machine lbs.List$358.00.Each......... selector. Drum ca: went cartridges c (')Limited availability�ontact local branch. M Equipment used for application purposes only.Office machinery not included. brand(Z76). 1590 - .. WHOLESALE PRICES-GRANGER SEE Multi-Application Peripherals 13®Simplex and Accessories Miscellaneous UL Listed 2088-Series (Air Products) Control Relays FEATURES: • UL Listed/Control Unit Accessory • Multiple Voltage Inputs • SPDT or DPDT Relays • • • • Relay Status LED • Metal Enclosures w/LED Viewing Ports • Track Mounting Hardware • "Snap-Apart" Featureo .,� • Single Relay Encapsulated Version SPECIFICATIONS: Power Requirements: 2088-9007, -9008, ' -9017, -9018, -9021.............0.015A @ 24VDC, 24VAC, \ 115VAC, 230VAC 2088-9009, -9010, • -9019, -9020........................0.035A @ 24VDC, 24VAC, 115VAC, 230VAC CONTROL RELAYS AND ENCLOSURE Contact Rating .................................. 10.OA @ 115VAC 2088-SERIES Temperature Range ............................. .58°F to +185°F -50°C to +85°C DIMENSIONS: Track Mounted (Single Relay)........................3"H x 2-1/8"W x 1-1/2"D (82.6mm x 54mm x 38.1 mm) (Four Relays)........................3"H x 8-1/2"W x 1-1/2"D (82.6mm x 215.Omm x 38.1 mm) Metal Enclosure (Single Relay)..................6-1/8"H x 3-1/4"W x 2-1/2"D (130.2mm x 82.6mm x 63.5mm) (Four Relays)...................6-1/8"H x 9-1/2"W x 2-1/2"D (130.2mm x 241.3mm x 63.5mm) Encapsulated Relay................... 1-1/2"H x 1"W x 7/8"D (38.1 mm x 25.4mm x 22.2mm) DESCRIPTION: c The 2088-series Control Relays offer SPDT or DPDT 10 Amp contact which may be operated by one of four input voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, 115VAC or 230VAC by wiring to appropriate input terminals. Each relay • contains a red LED which indicates the relay coil is energized. Track mounted relays may be "snapped apart"from a standard four-module assembly and used 2088-9021 independently.These devices are ideal for applications where local contacts are required for system status, ENCAPSULATED RELAY remote contacts for control of electrical loads and general purpose switching. Oo 1992 Simplex Time Recorder Co. Publication S2088-0010-2 12-92 PRODUCT MATRIX: • PID MODEL NUMBER NUMBER DESCRIPTION 2088-9007 MR-101 One SPDT Relay with LED & Track Mounting Hardware only. 2088-9008 _t MR-101/C One SPDT Relay with LED mounted in metal enclosure. 2088-9017 MR-104 Four SPDT Relays with LEDs&Track Mounting Hardware only. 2088-9018 MR-104/C Four SPDT Relays with LEDs mounted in metal enclosure. 2088-9009 MR-201 One DPDT Relay with LED&Track Mounting Hardware only. 2088-9010 MR-201/C One DPDT Relay with LED mounted in metal enclosure. 2088-9019 MR-204 Four DPDT Relays with LEDs&Track Mounted Hardware only. 2088-9020 MR-204/13 Four DPDT Relays with LEDs mounted in metal enclosure. 2088-9021 PAM-1 One SPDT Relay, Encapsulated with color coded wire leads. RELAY CONFIGURATION: SPDT Contacts • 10 AMPS<a DPDT Contacts 115 V.A.C. 10 AMPS(a 115 V.A.C. 1 N/C C N/O • I j O C NC NO C NCII 1 "RELAY j ENERGIZED" 1 INDICATOR � (LED) 1 � mmmm I Input 1 • 0 24 115 230 • 1 Input 1 • 0 24 115 230 • 1 Control 1 2 Control Voltage Voltage 24 V.D.C.— 24 V.D.C.— 24 V.A.C.— 24 V.A.C.— 115 V.A.C.— 115 V.A.C.— 230 V.A.C.— 230 V.A.C.— Simplex Time Recorder Co. Simplex Building Systems Gardner,Massachusetts T01441-0001hroughout U.S.A. Offices and Representatives Throughout the World FIRE DETECTION • SECURITY • COMMUNICATIONS • TIME CONTROL All specifications and other information shown were current as of publication,and are subject to change without notice. Printed in U.S.A. HARDWARE WARRANTY 1 . SIMPLEX WARRANTY STATEMENT: SIMPLEX WARRANTS TO THE PURCHASER OF NEW SIMPLEX PRODUCT(S) SHALL BE FREE TO DEFECTS IN WORKMANSHIP AND MATERIAL. 2. WARRANTY PERIOD: THE WARRANTY PERIOD WILL TERMINATE IMMEDIATELY FOLLOWING THE EARLIEST OCCURRENCE OF EITHER OF THE FOLLOWING: BUILDING SYSTEMS 1 ) 18 MONTHS HAVE ELAPSED FOLLOWING SHIPMENT OF ANY SYSTEM OR SUB-SYSTEM FORM SIMPLEX TO THE CUSTOMER, OR 2) 12 MONTHS HAVE ELAPSED FOLLOWING THE FINAL CONNECTION OPERATION AND BENEFICIAL USE OF ALL OR ANY PART OF THE SYSTEM. 3) AS STATED IN THE SPECIFICATIONS AND/OR CONTRACT DRAWINGS 3. SIMPLEX OBLIGATION UNDER THE TERMS OF THE WARRANTY: SIMPLEX'S SOLE RESPONSIBILITY SHALL BE TO REPAIR, ADJUST OR REPLACE, AT ITS OPTION, ANY SIMPLEX PRODUCT WHICH FAILS DURING THIS PERIOD PROVIDING PURCHASER HAS PROMPTLY REPORTED SUCH FAILURE TO SIMPLEX IN WRITING. REPLACEMENT PARTS WILL BE WARRANTED ONLY FOR THE BALANCE OF THE EQUIPMENT WARRANTY. SIMPLEX AGREES TO CONTINUE TO HONOR ALL OF THE UNEXPIRED EXPRESSED WARRANTIES SPECIFIED ABOVE ON DEFECTIVE EQUIPMENT AFTER TRANSFER OF THE EQUIPMENT TO PURCHASER'S CUSTOMER, PROVIDED PURCHASER'S CUSTOMER, PROVIDED PURCHASER'S CUSTOMER ASSUMES THE PURCHASER'S OBLIGATIONS SPECIFIED BELOW. EXCEPT FOR THE EXPRESSED WARRANTIES STATED HEREIN, SIMPLEX DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE STATED WARRANTIES ARE IN LIEU OF ALL OBLIGATIONS OR LIABILITIES ON THE PART OF SIMPLEX ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE PRODUCTS. THE SELLER SHALL NOT BE LIABLE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE TO THE PURCHASER OR USER OF THIS EQUIPMENT ARISING OUT OF THE FAILURE OF THE EQUIPMENT TO OPERATE IN EXCESS OF THE PURCHASE PRICE OF SAID EQUIPMENT. SIMPLEX MAKES NO WARRANTY AND NO WARRANTY SHALL BE DEEMED TO EXIST, THAT PURCHASER HOLDS THE GOODS FREE OF THE CLAIM OF ANY THIRD PERSON BY WAY OF PATENT INFRINGEMENT OF THE LIKE. 4. PURCHASER'S OBLIGATIONS UNDER THE TERMS OF THE WARRANTY. THIS WARRANTY IS CONTINGENT UPON THE PROPER INSTALLATION AND USE OF THE PRODUCT(S). SUCH WARRANTY SHALL NOT APPLY IF THE PRODUCT FAILURE IS THE RESULT OF ACCIDENT, UNUSUAL PHYSICAL, ELECTRICAL OR ELECTROMECHANICAL STRESS, NEGLECT, MISUSE, USER PROGRAMMING ERRORS, FAILURE OF ELECTRICAL POWER, AIR CONDITIONING OR HUMIDITY CONTROL, CONSTRUCTION DUST, DAMAGING FOREIGN SUBSTANCES, TRANSPORTATION OR CAUSES OTHER THAN MANUFACTURING DEFECT. PURCHASER AGREES TO PROVIDE FULL AND FREE ACCESS TO AUTHORIZED SIMPLEX EMPLOYEES. 5. WARRANTY SERVICE HOURS: SERVICES PROVIDED UNDER THIS WARRANTY WILL BE PERFORMED DURING 8:00 A.M. TO 5:00 P.M. MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. OFF HOURS RESPONSE IS AVAILABLE AS AN EXTRA COST SERVICE OPTION. 6. WARRANTY EXCLUSIONS: 1 ) LABOR, TRAVEL, AND MILEAGE FOR: A) SERVICE OUTSIDE OF SIMPLEX NORMAL BUSINESS HOURS. B) PROGRAMMING AND/OR LABEL CHANGES. C) FAILURE DUE TO EXTERNAL CAUSES (LIGHTING SURGES, CONSTRUCTION DUST, ETC.) OTHER THAN MANUFACTURING DEFECT. 2) ELECTRICAL WORK EXTERNAL TO THE EQUIPMENT SUPPLIED BY SIMPLEX OR MAINTENANCE OF ACCESSORIES, ALTERATIONS, ATTACHMENTS OF OTHER DEVICES NOT FURNISHED BY SIMPLEX. 3) BATTERIES 4) COVERAGE OF EQUIPMENT CLASSED AS A WATER FLOW MONITORING/CONTROL DEVICES INSTALLED IN OR ON WATER PIPING. MANUFACTURER'S RECOMMENDATION 1 . CONTRACTOR IS EXPECTED TO PULL AND TERMINATE ALL CONDUCTORS AND INSTALL ALL DEVICES FOR A COMPLETE AND OPERATING SYSTEM. 2. WHERE FAN SHUTDOWN, ELEVATOR RECALL OR SPECIAL AUXILIARY FUNCTIONS ARE REQUIRED, CONTRACTOR IS TO VERIFY WIRING REQUIREMENTS WITH THE SIMPLEX FACTORY TECHNICIAN ASSIGNED TO THE PROJECT (IN MANY CASES, SPECIAL WIRING WILL NOT BE SHOWN ON THE DRAWINGS). 3. WHERE POSSIBLE, THE CONTRACTOR IS TO USE COLOR CODE FOR ALL WIRING. 4. SMOKE DETECTORS ARE NOT TO BE MOUNTED WITHIN 4 FEET OF AIR OUTLETS. 5. CONTRACTOR SHOULD NOT INSTALL SMOKE DETECTOR HEADS IN BASED OR DUCT HOUSING UNTIL FINAL CHECKOUT TIME TO INSURE THAT DIRT OR DUST DOES NOT CONTAMINATE THE DETECTORS. 6. DO NOT POWER-UP SYSTEIA UNTIL SIMPLEX FACTORY TECHNICIAN IS PRESENT. 7. A SEPARATE GROUND (ISOLATED FROM CONDUIT GROUND) MUST BE PULLED TO ALL CABINETS. 8. LOADS GREATER THAN 10 AMPS (FOR AUXILIARY FUNCTIONS) ARE NOT ALLOWED IN THE SAME CONDUIT AS FIRE ALARM. 9. CONTRACTOR IS TO NOTIFY SIMPLEX ONE WEEK BEFORE FINAL CHECKOUT. (206-632-4424) 10. CONTRACTOR IS TO ENSURE THAT ALL WIRING AND SHIELDS ARE FREE OF SHORTS, GROUND AND OPENS. 11 . UNDERGROUND WIRING MUST MAINTAIN ONE MEGOHM 20F RESISTANCE TO GROUND. 12. ANY MANUFACTURER'S RECOMMENDATION IN CONFLICT WITH ENGINEERING DRAWING OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION. CONTRACTOR SHALL ADVISE SIMPLEX TIME RECORDER OF ANY CHANGES. 13. PROTECTIVE COVERS ON SMOKE DETECTORS ARE NOT TO BE REMOVED UNTIL OWNERS ACCEPTANCE OF THE SYSTEM. (PREVENTS CONTAMINATION OF SMOKE CHAMBER) 14. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REQUEST FOR THE STATE OR LOCAL FIRE MARSHAL TO BE ON SITE FOR FINAL ACCEPTANCE AND CHECK OUT IF REQUIRED. 15. OWNERS PRESENCE FOR FINAL DEMONSTRATION AND ACCEPTANCE. SPECIAL INSTRUCTIONS-SIMPLEX 1 . SIMPLEX WILL PROVIDE WIRING INSTRUCTIONS FOR INSTALLATION OF SIMPLEX EQUIPMENT. 2. SIMPLEX WILL PROVIDE A FACTORY TRAINED TECHNICIAN TO REVIEW THE OPERATION OF THE SYSTEM AND THE CORRECT METHOD BY WHICH THE EQUIPMENT SHALL BE WIRED AND CONNECTED. PLEASE CALL (206) 632-4424 FIVE (5) DAYS BEFORE NEEDING VISIT. 3. SIMPLEX WILL PROVIDE A FACTORY TRAINED TECHNICIAN TO ASSIST IN TRAINING: - OPERATION OF THE CONTROL PANEL AND FUNCTIONS ALARM TEST OF ALL SIMPLEX PERIPHERAL DEVICES (SMOKE DETECTOR, MANUAL PULL STATION, ETC.) - SUPERVISOR TEST OF ALL INITIATING, SIGNALING, AND CONTROL CIRCUITS. 4. SIMPLEX WILL PROVIDE (1 ) INSTRUCTION AT FINAL TEST OF THE SYSTEM TO: - OWNER REPRESENTATIVE - FIRE INSPECTOR AND ELECTRICAL INSPECTOR ARCHITECT AND ENGINEER 5. UPON COMPLETION OF FINAL TEST, SIMPLEX WILL PROVIDE: TEST REPORT - CERTIFICATION (IF REQUIRED) ONE YEAR WARRANTY TESTING PROCEDURE FOR DEVICES GENERAL: FOR ALL DEVICES (SUPPLIED BY SIMPLEX) VISUALLY VERIFY PROPER LOCATION AND INSTALLATION. SMOKE DETECTORS: ACTIVATE THE DEVICE USING A SMOKE GENERATOR AND VERIFY ALARM CONDITION ON PANEL. RESET PANEL AND VERIFY RESET OF SMOKE DETECTOR AND PANEL. TEST FOR ALARM VERIFICATION IF APPROPRIATE. HEAT DETECTORS: FIXED TEMPERATURE REPLACEMENT ELEMENT - REMOVE ELEMENT ON HEAT DETECTOR TO INITIATE ALARM AND VERIFY ALARM CONDITION AT PANEL. REINSTALL ELEMENT, RESET SYSTEM, AND VERIFY. NON-REPLACEABLE ELEMENT - NON-REPLACEABLE ELEMENT HEAT DETECTORS CAN ONLY BE TESTED FOR CONTINUITY TO DEVICE. RATE-OR-RISE DETECTORS - RATE-OR-RISE DETECTORS ARE TESTED WITH A HEATER OR BLOW DRYER UNTIL THEY INITIATE ALARM, THEN ALLOWED TO COOL. RESET PANEL AND VERIFY. PULL STATIONS: ACTIVATE THE STATION WITH THE T-HANDLE, VERIFY ALARM AND LABEL FOR LOCATION, RESET STATION, RESET PANEL. DUCT DETECTOR: (PROVIDED BY SIMPLEX) REMOVE DUCT DETECTOR HOUSING COVER AND ACTIVATE DEVICE WITH SMOKE, VERIFY ALARM, TEST ALL INDICATORS OR MANUAL TEST SWITCHES, RESET DETECTOR, RESET PANEL. TEST SAMPLE AND REFERENCE TUBE FOR POSITIVE AIR FLOW. (NOT PROVIDED BY SIMPLEX) VERIFY THAT ZONE CIRCUIT IS PRESENT AT THE DEVICE. AUDIBLES AND VISIBLES: ACTIVATE ALARM AND CONFIRM THAT ALL INDICATING APPLIANCES, AUDIBLES AND VISIBLES, ARE OPERATING. DOOR HOLDERS: VERIFY THAT DOORS CLOSE ON ALARM. VALVE SUPERVISORY SWITCHES (TAMPER): (PROVIDED BY SIMPLEX) ACTIVATE SWITCH BY MOVING VALVE OFF NORMAL, VERIFY STATUS CHANGE, RESET SWITCH, RESET PANEL. (NOT PROVIDED BY SIMPLEX) VERIFY THAT ZONE CIRCUIT IS PRESENT AT THE SWITCH. FLOW SWITCHES AND PRESSURE SWITCHES: (PROVIDED BY SIMPLEX) ACTIVATE SWITCH (WITH SPRINKLER CONTRACTOR PRESENT) BY A FLOW OF WATER, VERIFY STATUS CHANGE, RESET SWITCHES, RESET PANEL. (NOT PROVIDED BY SIMPLEX) VERIFY THAT ZONE CIRCUIT IS PRESENT AND SUPERVISED AT THE SWITCH. FAN/DAMPER CONTROL CIRCUITS: VERIFY (WITH HVAC CONTRACTOR PRESENT) THAT THE CONTROL CIRCUIT IS OPERATING AND THE DEVICE IS BEING CONTROLLED IN ACCORDANCE WITH THE SPECIFIED SEQUENCE OF OPERATION. TRAINING: SIMPLEX SHALL PROVIDE A ONE SESSION SEMINAR TO THE CUSTOMER. WARRANTY: THE SYSTEM SHALL BE PROVIDED WITH A ONE YEAR HARDWARE WARRANTY. Simplex Technical Installer Support (TIS) TIS is designed to make the expertise of a Simplex technician available at key scheduled times during the project. This service is available during normal Simplex working hours if scheduled five working days in advance. TIS includes the following activities by a factory trained technician when determined by Simplex to be appropriate. - Preconstruction review of submittals and drawings with the installer. - Technical advice during initial start up of control panels (including transponders) before installer wiring is connected. - Review of panel wiring and preparation of a list of items to be corrected by the installer. - Program editing to correct minor errors and omissions. - Assistance with one complete functional test of the system. - One training session for the owner's representatives. Additional installation support may be purchased from Simplex. TIS enhances expertise in Simplex installations but not supplant the installer's commitment to: 1 . Provide skilled labor and supervision to complete the project. 2. Review and understand Simplex instructions for installing and testing Simplex equipment. Potential Problems can be avoided by adhering to the following: Do not initially start up the system except in the presence of a Simplex technician. Simplex assumes no liability for damaged equipment and warranty may be voided if this procedure is not followed. Do not install smoke detectors (unless protected by plastic bags) until final construction clean up has occurred. This is to prevent damage caused by dust, dirt, and paint. Detectors installed prior to clean up may require disassembly, cleaning, or replacement which is not covered by warranty. Care must be taken to protect equipment during the installation and warranty period. Failures due to external causes (lightning surges, construction dust, water damage, etc.) will be repaired by Simplex only upon receipt of a valid written Purchase Order. - TIS includes on complete system test which is coordinated by the installer. To avoid additional charges, installer should schedule his test so that all appropriate parties are present.