HomeMy WebLinkAboutCOM2024-00056 Cell Tower Upgrade - COM Inspections - 2/20/2025 INSPECTION CARD
Mason County
615 W. Alder St.
Building 8, Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
PERMIT# COM2024-00056 PROJECT ADDRESS 80 E UNION HEIGHTS PL SOUTH UNION, WA 98592
PARCEL# 322323390061 PROJECT DESCRIPTION Equipment Upgrades at an existing wireless facility
OWNER ANSTEY SHAWN A ADDRESS P O BOX 26 PHONE
CONTRACTOR ADDRESS PHONE
CONTRACTOR LICENSE LENDER
INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments
KNOX BOX VEf21ftCATION---71 �BLD-Final Inspection keceJ t
INSPECTION RESULTS Pagel
MASON COUNTY Department of Community Development
COMMUNITY DEVELOPMENT 615 W Alder St, Shelton,WA 98584
Permit Assistance Center,Building,Plannu,g (360)427-9670 ext. 352
Application # COM2024-00056 Application Type CELL TOWER UPGRADE Owner ANSTEY SHAWN A
Parcel# 322323390061 Site Address 80 E UNION HEIGHTS PL SOUTH UNION,
WA 98592
Inspector Inspection Type Date Status Comments
2-13-25 DEC
UNABLE TO GAIN ACCESS TO THE SITE.
PLEASE SEND A LETTER FROM THE PROJECT ENGINEER/MANAGER
Drew Carlson BLD-FINAL INSPECTION 02/13/2025 PENDING VERIFING THAT ALL WORK WAS DONE ACCORDING TO PLAN SPECS AND
BEST PRACTICES.
INCLUDE WITH EMAIL PERMIT#, NAME ON PERMIT AND ADDRESS
DREWC@MASONCOUNTYWA.GOV
A Gel
21501 84TH Ave S. Kent WA 98032
February 18, 202S
( 1
From, JI'tlV`
Veena Parasuraman
Project Manager
Atelz123 Corp. VV1
To whom it may concern,
Sub: BP#COM2024-00056 letter of
completion
Atelz123 confirms the following:
The work as proposed has been completed in accordance with the approved construction
drawings, the approved structural analysis, and the 2018 International Building Code.
The tower does not support emergency communications systems or systems as defined under Risk
Category III and IV in Table 1604.5 Risk Category of Buildings and Other Structures, found in
Chapter 16 the 2018 IBC.
Attached along with the letter are the redlined CD and some pictures from work completed.
For any further question, please contact Atelz123.
Thank you!
Regards,
Veena Parasuraman
Project Manager
469-861-9318
Veena.p@atelz123.com
GENERAL NOTES DRAWING INDEX
THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. AT&TA TEPROJECT WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. � BHT NO. ' DESCRIPTION _
THE PROJECT DWILL RAINAGE
RESULT IN ANY SIGNIFICANT DISTURBANCE OR y�'wv
EFFECT ON DRAINAGE',NO SANITARY SEWER SERVICE.POTABLE WATER,OR T•1 7LE SHE T -'
TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. N7 GENERAL NOTES M"M'
SITE INFORMATION O L64 N2 OVERALL NOTES
A-1 OVERALL SITE PLAN FENCE C
LATITUDE: 47'20 50.00'N(47.347222') W t M Ay Q�
AAA ENLARGED SITE PLAN
LONGITUDE: 123'W 05.00'W(-123.101389') O,
E U MENTPLANS "O f�
GROUND ELEVATIONTION. MASt453ON
AMSLCOUNTY
AYRES POINT A-3 ANTENNA PLANS
1
JURISDICTION'. MASON COUNTY
ZONING: RURAL RESIDENTIAL(RR)
PARCEL O: 322-32.3390061 A-5 EL ON EVATIS ), j }<19 TER1'O
COUNTY MASON COUNTY 100 EAST UNION HEIGHTS PLACE SOUTH A ET
E%ISTING USE: UNMANNED TELECOMMUNICATIONS FACILITY A7 DETAILS
POWER COMPANY. GRANT COUNTY PUBLIC UTILITY DISTRICT UNION, WA 98592 AI DETAILS E%P 6/3/2(M6
DETAILS
PROJECT: LTE 1C RRH SWAP A9 GROUNDING
D-1 G GROUNDING DETAILS
IWM JOB NUMBER PACE JOB NUMBER ORACLE PTN
WSWOR0030558 MRWOR075979 3801AIIAD6.1 L ATTACHMENTS 2 1y13/24 1cuB 1moBUI
WJSWOR0030615 MRWOR076111 3801AIADSK MOUNT MODIFICATION DRAWINGS
1 01/1dN Mw l4EOB5
SCOPE OF WORK WSWOR0030297 MRWOR076029 3801A1ADBF 0 06/1w"ROLas
ST1 STRUCTURAL TITLE S5 CROSSOVER
ATBT MRELESS PROPOSES TO MODIFY AN EXISTING FACILITY.THE SCOPE VVSVrOR0030663 MRW'OR075968 3801A1ADBL SPECIFICATION SHEET
WALL CONSIST OF THE FOLLOWING. A OS/16/i4 PABI/0NT COS
_ _ WBWpR0030482 MRVVOR075885 3801AtADBH MOUNT PLANS
NHQ LE L:
WSVVOR0030802 MRMR075969 3801AIADBM 51 MODIFICATION SCHEDULE S6 CONNECTOR ,�
SPECIFICATION SHEET
•REORIENTED ANTENNAPLATFORMMOUHT WSWOR0030396 MRWOR075876 3SOlAlAD22 STANDOFFAR AS
•REMOVE ALL RRU PIPE MOUNTS MOUHT S2 MOUNT ELEVATONS S] C
•RE MOVE(8)PIPE TO PIPE MOUNTS MODIFICATIONS W5WOR0040816 - - SPECIFICATION SHEET a sTe c
REMOVE IS B(X)I 92 PANEL ANTENNAS REQUIRED S3 MOUNT ELEVATIONS SNt STRUCTURAL NOTES
•RELOCATE(3)80010992 PANEL ANTENNAS FA: 10038048 USID: 49169 S4 MOUNT SECTION DETAILS Communications Group
REMOVE(12)1-SA-COAX CABLES
•
RELOCATE(1)DC6 SURGE SUPPRESSOR VICINITY MAP OJ 11b1= ` ' "+
•RELOCATE(1)DC9 SURGE SUPPRESSOR ' lA1I
•REMOVE OWNER(12)RRUS AFF4mM:
•REMOVE(3)TMAS CLIENT REPRESENTATIVE PROPERTY OWNER
•INSTALL(5)12072EPANELANTENNAS •usr cMnaNMA4rwnaR OPO1iP vBu oANI F V
•INS TALL
(4)STACKED AIRS419 B77D•AIR6419 B77G ANTENNAS a 1O1
•INSTALL(I)4190 B5I812A RRU& coµNt•cT 6�wu¢LNOK"LEn u4oN wACNRO
j •I NSTALL(4)4478B+4RRUS Q x vw"IL"'° --'0�T`— TOWER OWNER AT&T
.Nl •INSTALL(4)4890825/Bee RRUS cRpl6�yl�
•INSTALL(4)M15 B30 RRUS PROJECT OWNER ]wocWwMTE OMY£
•INSTALL(1)DC9 SURGE SUPPRESSOR 1�1T 7!7TH ST MF
•INSTALLIt)HOISTING GRIP IT TMw•swlcT- xw+ MASTEC A.PM: 016IN0+61L 0C 1DOOt
•INSTALL(1)24 PAIR FIBER TRUNK
a • `By
INSTALL(4)08AW.GDC POWER TRUNKS - PROFESSIONAL OF RECORD m•. •ni•Onw� _ �
•INSTALL(8)ROSENBERGER D20MRRU(AT&T APPROVED OR EQUAL)DUAL T,pw vnF sm MA
STEC CONSTRUCTION PM'.
RRU MOUNTS 2 ��
•INSTALL STIFF ARM PIPES ON STANDOFFS ATTACHED TO EXISTING ,F •""• s "NCE COO"v ^"^"I`"^•'°p^"'°m" MONw+soNiHcwsHrIMLA
PLATFORM.SECTOR B,C i D.SEE MOUNT MODIFICATION DRAWINGS 1 ^'°"E I�'°'-0'u
EQUIPMENT LEVEL: 7 ®Sta-{. C B
•REMOVE ALL EXISTING NOKA BBUS �`� PROJECT �7 �F�6WW�br
•REMOVE(3)C SITE
ONVERTERS F,
•REMOVE(1)BATTERY CABINET CODE COMPLIANCE +riq yM>OM��
•INSTALL I7)FLX42 CABINET w�N•r•rW�
e •INSTALL(1)DC12 Pit
•IN8TALL(2)RECTIFIERS 1. 2021 INTERNATIONAL BUILDING CODE(IBC) OL(74
IN (2)6651 BASEBANDS IN FLX42 2. 20M NATIONAL ELECTRICAL CODE(NEC) AYRES POINT
•INSTALL(1)66101N FU42 3. M I INTERNATIONAL MECHANICAL CODE(MC) FA:10038048
•INSTALL(4)BOA BREAKERS FOR AIR6419 677D 4. 2021 UNIFORM PLUMBING CODE III 100 FAST MI:1 IE138 RACE SUI11X
•INSTALL(4)SOABREAKERSFORAIRS419877G `y ` `
•INSTALL(4)2SA BREAKERS FOR 4415 BW ULtABO WA UiNrr
•INSTALL(4)2M BREAKERS FOR 4478 B14 �
.INS TALL(4)SOABREAKERSFOR449085/812A REDLINED M9
•INSTALL(2)SOA BREAKERS FOR 6651 B25/866
-INSTALL(1)+SA BREAKERS FOFOR 6851 JOOF11hQaWzl23com TITLE SHEET
.wsrAu(1)SA BREAKER FOR 66+0 DRIVING DIRECTIONS
*1(909)202-0549
FROM KING COUNTY INTERNATIONAL AIRPORT:
HEAD SOUTHEAST ON KING COUNTY AIRPORT ACCESS RD.TURN LEFT ONTO PERIMETER RD S.TURN RIGHT ONTO S OTHELLO S.TURN RIGHT ONTO 02/13/2025 2401217ao YAS-617R1
EXISTING ANTENNA COUHT: 08 AIRPORT WY S.MERGE WITH S BOEING ACCESS RD.USE THE RIGHT 2 LANES TO TURN RIGHT ONTO MARTIN LUTHER KING JR WAY S.USE THE RIGHT _0_ 0a1
` FINAL ANTENNA COUNT' I LANE TO MERGE WITH LS S NA THE RAMP TO PORTLAND.MERGE NTH F8 S.KEEP RIGHT TO STAY ON IS S.KEEP RIGHT TO STAY ON L5 S.USE THE APPROVALS ,A o6 16 x4 A
EXISTING RRU COUNT 12 2ND FROM THE RIGHT LANE TO TAKE THE EXIT TOWARD WA-18 W.USE THE LEFT LANE TO TAKE THE RAMP ONTO W/A-18 W.USE THE LEFT LANE TO
FINAL RRU COUNT: 16 TAKE EXIT 28 TOWARD WA41 SMELFAIWSHELTON.CONTINUE ONTO WA-16 W.TURN LEFT ONTO WA.3.CONTINUE STRAIGHT ONTO WAJ S.AT THE Orwn 9A CIwa1�4 IA
AT&T RF ENGINEER. DATE:
ROUNDABOUT,CONTINUE STRAIGHT TO STAY ON N WAS.CONTINUE STRAIGHT TO STAY ON RN L S AT THE ROUNDABOUT,TAKE THE 2ND EXIT AND LID -
STAY ON NR.S.CONTINUE STRAIGHT UNION
TO STAY ON R.TURN
S.TURN RIGHT ONTO NWAAMHEIGHTS
W.TURN LEFT ONTO E WILL B RD.TURN RIGHT ONTO E AT&T CONSTRUCTION' DATE: W � C4RA 71FI�
MCREAW RD.SHARP LEFT ONTO UNION HEIGHTS DR.TURN LEFT ONTO E UNION HEIGHTS PL S.DESTINATION WILL BE ON THE LEFT. - ClG
11'XITPLOTWLLBEFKFSCNEUKUSSOTHERVVMK4 EO NOTE: AT&TSAM: DATE: �. hwMBNA
48 HOURS PRIOR TO DIGGING,
CONTRACTOR SHALL VERIFY ALL PLANS 8 EXISTING DIMENSIONS 8 CONTRACTOR TO NOTIFY ALL UTILITY LANDLORD: DATE. T-1
CONDITIONS ON THE JOB SITE 8 SHALL IMMEDIATELY NOTIFY THE COMPANIES TO LOCATE ALL 2
ENGINEER IN W R NG OF ANY DISCREPANCIES BEFORE PROCEEDING UNDERGROUND UTILITIES LANDLORD. DATE. 2
6 VATH THE WORK OR BE RESPONSIBLE FOR SAME
2 3 4 5 6
a
� h
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
FPROJECT
4-00056 CELL TOWER UPGRADE
ESCRIPTION: EQUIPMENT UPGRADES AT AN EXISTING ISSUED: 08/16/2024
FACILITY
ESS: 80 E UNION HEIGHTS PL SOUTH UNION EXPIRES: 02/12/2025
PARCEL: 322323390061
APPLICANT: AT&T-McMullin,Thomas OWNER: ANSTEY SHAWN A
1351, E Irving Park Road P O BOX 26
Itasca, IL 60143 UNION,WA 98592
6302286229
VALUATIONS: FEES: Paid Due
Project Valuation (BID, 25750.00 $25,750.00 State Fee-Commercial $25.00 $0.00
ESTIMATION..) Planning Commercial Review $380.00 $0.00
Fee
Plan Check Fee $279.74 $0.00
Building Permit Fee $430.37 $0.00
Technology Surcharge $14.20 $0.00
Total: $25,750.00 Totals : $1,129.31 $0.00
REQUIRED INSPECTIONS
BLD-Final Inspection
CONDITIONS
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Code 14.28 and 14.17.
Printed by:Annie Wilson on:08/16/2024 04:13 PM
Page 1 of 3
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
CELL TOWER UPGRADE COM2024-00056
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site,then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* All permits expire 180 days after permit issuance,or 180 days after the last inspection activity is performed. The Building
Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit
expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being
taken.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the farthest projection of the
structure. Front setbacks are measured from the front lot line or road easement boundary, whichever is closer.
* The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
* Comply with requirements of Mason County ORD 5-98
Printed by:Annie Wilson on:08/16/2024 04:13 PM
Page 2 of 3
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncoun"a.gov
CELL TOWER UPGRADE COM2024-00056
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisionJs� of any othe�rystlate/local law regulating construction or the performance of construction.
Issued By: V1I
Contractor or Authorized Agent: Seji4 A, PAaj Date:
Printed by:Annie Wilson on:08/16/2024 04:13 PM