HomeMy WebLinkAboutBLD2024-00810 Mechanical - BLD Inspections - 1/13/2025 INSPECTION CARD
Mason County
615 W. Alder St.
Building 8, Shelton,WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
r
PERMIT# BLD2024-00810 PROJECT ADDRESS 360 E WALTER SCOTT DR SHELTON, A 98 t84
PARCEL# 220131150240 PROJECT DESCRIPTION WOOD STOVE
OWNER HOLM-HANSEN KEVIN 8 JO ADDRESS 360 E WALTER SCOTT DR PHONE 1.802.349.3231
CONTRACTOR ADDRESS PHONE
CONTRACTOR LICENSE LENDER
INSPECTION INSP I DATE Comments INSPECTION INSP I DATE Comments
Mechanical/Plumbing Final � 4SS
s
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
BLD2024-00810 MECH/PLUMB - RESIDENTIAL
PROJECT DESCRIPTION: WOOD STOVE ISSUED: 07/08/2024
SITE ADDRESS: 360 E WALTER SCOTT DR SHELTON
EXPIRES: 01/04/2025
PARCEL: 220131150240
APPLICANT: HOLM-HANSEN KEVIN &JO OWNER: HOLM-HANSEN KEVIN &JO
360 E WALTER SCOTT DR 360 E WALTER SCOTT DR
SHELTON, WA 98584 SHELTON, WA 98584
1.802.349.3231
FEES: Paid Due
Technology Flat Convenience $5.00 $0.00
Fee
Final Inspection $80.00 $0.00
Mechanical Fees $80.00 $0.00
Mechanical Base Fee $30.00 $0.00
State Fee-Residential $6.50 $0.00
Totals : $201.50 $0.00
FIXTURES
City Mechanical Fixtures
1.0000 Wood/Gas/Pellet Stove(s)
REQUIRED INSPECTIONS
Mechanical/Plumbing Final Inspection
CONDITIONS
All furnace installations shall meet the minimum efficiencies set forth in the current edition of the Washington state energy
code (WSEC). any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth
in the WSEC and international mechanical code.
Printed by:Genie Mcfarland on:07/08/2024 04:26 PM
Page 1 of 3
Mason County
mp
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECH/PLUMB - RESIDENTIAL BLD2024-00810
* OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED.
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit
expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being
taken.
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Code 14.28 and 14.17.
* By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency
(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos
containing materials have been identified and removed from the area to be demolished. Work shall not commence on an
asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B
Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
Printed by:Genie Mcfadand on:07/08/2024 04:26 PM
Page 2 of 3
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
MECH/PLUMB - RESIDENTIAL BLD2024-00810
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Authorized!Agent: - Date: �� d '
Printed by:Genie Mcfarland on:07/08/2024 04:26 PM
Page 3 of 3
MASON COUNTY COMMUNITY SERVICES Permit No:�I 2 24-' Oog 1 ,
PERMIT ASSISTANCE CENTER:
BUILDING -PLANNING -FIRE MARSHAL
• 615 W.Alder St-Shelton,WA 98584
www.co.mason.wa.us
Phone Shelton:(360)427-9670 ext 352• Fax:(360)427-7798
• Phone Belfair. (360)2754467- Phone Elma:(360)482-5269
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION• CONTRACTOR INFORMATION:
NAME: .I o I - 14fl-A s e^ NAME:
MAILING ADDRESS: 3 on C--- ur l+e✓Scol{ Dr-- MAILING ADDRESS:
CITY: n t4a STATE:,,,l A _ZIP: _q CITY: STATE: ZIP:
1s`PHONE: a - PHONE: CELL:
2ud PHONE:
fig, EMAIL
EMAIL: kN wKa5n® Yr L.od Goner L&I REG# EXP. /
PARCEL INFORMATION:
PARCEL NUMBER(I2 Digit Number): Zoning.
LEGAL DESCRIPTION(Abbreviated):
SITE ADDRESS: 3r o r k��u 1l-n, gip(# D C CITY: ltDA
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB:
NEW ADD ALT REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS—1s"FLOOR 2ND FLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
Bath Tubs Heat Pump
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks �To--o�/Pellet Stove I
Dishwasher Exhaust Hood
Hose bibs Dryer Vent
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below.I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of
interest regarding this project The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVAL�TE THE APPLICATION.
42
X - - 1)4 a
Signature of Owner Date
DEPARTMENTAL REVIEW APPROVED I DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Rev:1/27/2016 JBN
3 Dimensions and Clearances
A.Appliance Dimensions NOTE: Flue Collar size is 6" (152mm) diameter(ID)
• 24-518"
-625 mm
Flue Centerline 17-112"25-314" to glass surface 445 mm 18 7116"
654 mm 479 mm
4"1102 mm ---
From Glue
f 16-318"
416 mm�
---- 23-1116" Door opening
586 mm i' vvidth
Figure 3.1 -Front View Figure 3.2-Top View
25.518"
651 mm
z n�utmaar
27"
25.3/4" 686 mm
654 mm ❑ 22-891
v..na�emrs
575 mm
13-318" -
340 mm
Figure 3.2-Side View-Top Vent Figure 3.4-Side View-Rear Vent
8 Vermont Castings Dauntless FlexBum Installation Manual_R13 • 2020-—• 07/23 3-90-586000i
B. Hearth Protection Requirements A
FLOOR PROTECTION: It is necessary to install a Type 1 CAUTION
floor protector. (Spark& Ember protection ONLY) Hearth and Home Technologies does not recommend
Floor protector must be non-combustible material extending adhesive based vinyl flooring due to thermal expansion,
under the appliance to a minimum of 16"(406 mm) in front of Floating-style flooring (LVP - luxury vinyl plank or LVT—
glass,and 8"(203 mm)to both sides of the fuel loading door. luxury vinyl tile)can be used,but it will reach temperatures
Open the door and measure 8"(203 mm)from the side edge up to 110 'F in a room with ambient temperature of 70
of the opening in the face of the appliance. "See exception. 'F. Consult flooring specifications to ensure compatibility.
In Canada,similar floor protection must be provided 18"(457 HHT recommends wood stoves and inserts have 57
mm) in front and 8" (203 mm)from the sides and rear of the inches of alternative flooring in front of the stove before
appliance, Figure 3.8 using LVP/LVT regardless if they sit flush on the floor or
are elevated on a raised hearth.
'"EXCEPTION: Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal For all other flooring, continue to follow clearance to
venting and extend 2"(51 mm)beyond each side, Figure 3.7. combustible requirements in the installation manual.
NOTICE: Clearances that do not meet the minimum
A WARNING guidelines could result in damage or buckling to the vinyl
flooring and is done at the installer's risk-
Fire Risk
Hearth pads must be installed exactly as
specified. High temperatures or hot embers
may ignite concealed combustibles.
35-Y8in. Corner hearth pad dimensions for all single wall pipe installations
! minimum
i"
r P�"
39.3/8 in.
m[i„mum 'r4�
—8 in I 6 �
16 in f
(FRONT DOOR OPENING) ,
CANADA
USA USA ..
Figure 3.5 Figure 3.6
Must extend 2m Corner hearth ad dimensions with double wall pipe- US ONLY
[51 mm1 beyond each p p p
side of pipe(shaded area)
46 n
[103 2 mm)
em \R113 mml ,�,
47-3/4 in
11212—1 .C.
rain tr %
mmi
leln tl l-_
1457 mm1
(FRONT DOOR OPUS" USA
CANADA + �/
Figure 3.7 Figure 3.8
3-90-586000i Vermont Castings Dauntless FlexBurn Installation Manual_R13 2020-_• 07/23 9
C. Clearances to Combustibles
Minimum Clearances to Combustible Materials
Note:A, C and F Dimensions are to the center of the flue collar
Installation: Full Vertical
A B C D E F G H*
Single Wall Pipe 18" 14" 26-1/2" 14" 15" 19-1/2" 57-1/2" 18"
Double Wall Pipe 16" 12" 24-1/2" 12" 7" 12" 57-1/2" 18"
Installation: 90 Degree Elbow off Top of Appliance through back wall
Single Wall Pipe 16" 12" 1 24-1/2" 1 12" 1 15" 19-1/2" 57-1/2" 18"
Installation: Horizontal Through the Wall
Single Wall Pipe 10" 26-1/2" 14"
Alcove, Double 12" 18" 38"
Wall Pipe
For Factory Alcove:6"diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A Chimney or
Masonry chimney. Maximum depth Alcove shall be no more than 48"(1219 mm)and the referenced Alcove clearances.Canada must
comply with CAN/ULC-S269 M87 for the 650°factory built chimney.
*Follow pipe manufacturers clearances as required.
NOTE:Double wall pipe clearances are for US installations ONLY.Canadian installations must conform with local code.In the absence
-� of local codes you must comply with the ULC S627-00 and CAN/CSA-B365.
Side View Back wall/Sidewall
B Horizontal Through Wall
A Top and Side View
a
A c
Mental
i
12"Max
D
"
26.112' 1334 334 mm
673 mm
JFMI P
Top View Corner Installationa
F 10
C 254 mm
H•
O . E
G
Appliance to
Calling Clearance
Figure 3.9-Alcove Clearances are for double wall pipe only.
A WARNING
Fire Risk
• Comply with all minimum clearances to
combustibles as specified.
• Failure to comply may cause house fire.
Figure 3.10
10 Vermont Castings • Dauntless FlexBum Installation Manual_R13 • 2020-_• 07/23 3-90-586000i
NF
P
Standard for Chimneys,
Fireplaces, Vents, and Solid
Fuel-Burning Appliances
CONIMITTEE PERSON'NF1 211-3
Technical Committee on C.`ttitnne}'s,Fireptaces,and Venting Systerns for Heart-Producing Appliances
Dak W.Fth.(stair
k1rephce tmrestiRaaon,Rcxarch&"tranon Service.CA[SE)
Jos P.Bmwer,Magic Sweet Corporanon.VA JIM I Todd Meager,SchAeles lingineeml;Inc..MO[SE)
KrIc`Ational C h aturey Sweep C"M Anthony R.O'Neill,Boothbay Harbor SiF ICI
Randy Brooks.tkook%ChmureySwcepin&Ga JIM1 IIanatd 1..Ornstein,EFI Global,Inc,MD IS£l
Jonathan L Coosa,D f.C arum,Inc..PA Inl j Keith Page,StIlt"' Hart&Cooley,Inc-,)a[MI
Rick Cwheet.Itocrtek 1esung Services,%RI I.Fal aria,Puck.`Iravelen Indemnity CxWgM y.Cr III
Nicholas A.Dwwe,Cohh County F'uc Marshal's(jffice.CA(El Thanatos A.Pierre.Piero Fie Im-esd at=ous,CA ESE)
Mitiad DeRlatio.M.DeStasto.Inc..MA IBM) Robert A.Prime Havelucki Chiamey&%'rutting,Inc,NC(IMI
Royal Fdwwda,Stffner,YL.)SEI Siam Ray,Metal-FA.Inc.,CIS(At)
LAM Gregon,AHPEA RMHPBA,MT[SU Rep.AirCondittoning,kltadng.&Re{tigcrauou Institute
Robert D.Harper.Htarthman Spttialuim PA LIE Robert A.R udism.0615 tudtatnes,Inc..NN[1t
LAIC Herraorrsts,k en 11MUMwt Fit plue Inc„P.4 ISE] Mkbod I..Save,Ste.Marion County Building Safety,FL IEJ
We D.Hersey;Staub of Maine,ME IEJ Patel IL SkWo9k,Fanlsault.MN ISEj
Vickie Hodgetr.State Firm Insurance Gom panim,IL I i I Tbomw Stroud.lk-milt.Pane&Barbecue Association,WA[M]
Chris Hurn,VAn-Pacter Company.IL IMI Rep.Ile uth,Patio,atki Subtcut Assomsion
Mmrek Kutilt,'ieduaticat Standards and Safety Authority.Canada IEJ Ri'Lard%Uhoa.J"tionW Fireltatt Institute,VJ,ISEi
Tanothy ,lAcN aky,RM Manifold Group Inc..dba CS.S.Draft Rep.i trarth Patio&Barbecue F.ducati a Foumbdon(HPBF_Fj
Cotnpany,'I X[M] Ra:hetr J.Zieoewnnaa,jr,LIL LIaC,IL IRTJ
Alternate%
51104 rb Somali.Vt.LI.K'.,II.twit Brian Ltegter,Inte tek.WI(KT)
(Ak to Robert j Zmamermim jr.) i.sit.to Rid:Curkeet)
jam W oodrnft.Fire1ech,CA[SBI
(Ak.to Die W.Feb)
rN--A +s
jam U.S.C am loser Product Sadery OwAnusdo n,MD[C)
Rep.IJS.Goraauwu r Per duct Safety GmunWort
Lit Htaann,NFPA Safi Liaison
This but rrpr"mu:Ar mneboAtp at the bow the Cataurtkr s+u bal&vaat oon R1c lineal star of rhos afzKso.
Sim AW hmea thangn la Me sarsatertAtO way Amv.ts u rued A"to dkitu fimhaw isl'avnd ai the
bad'Q/dW drxvarrW
NOM Mentbcrslup,ins o convautwe shall not in and of tortf corAtinne an endonernent of
the Asxsoaaou or any doctmartu dettrtoped by the commat"on which the atanber sertrs.
Conrakwe Scope:This Gonumurc shalt hate primary resporasibitity for documents on fire
safety for the cowww,tion,installation.wad too a,f dtitnneys,f teplsm,vents,venting
systems,and so1W fuel4mminA appliances.It afro shall be rdponsibie for documents an
ckaranccs of hcasjwodtta~aag appliances from combustible urateriais and terms relating w
chimneys,vents,and brat-prrtdttcang Appfimces.
211.44 CHIMNEYS,FIREPLACES.VMN'M,AND SOLID FUEL,-BURNING APPLIANCES
Table 13.5.2.1 Reduction of Appliance Clearance with Specified Forms of Protection
Maximum Allowable 1Nioimmn Clearance
Reduction in --
Clearartce(%) As Wall Protector As CeilingProtector
Clearance Reduction Applied to and(:overing All ___�.
Combustible Surfaces Within the Distance Specified as As Wall As Ceiling
Required Clearance with No Protection* Protector Protector in. tm bs. inm
(a) 3!4 in.(90 mm)thick masonry wall without 33 — 24 610 — —
ventilated airspace
(b) '%in.(13 mm)thick noncombustible insulation 50 33 18 457 24 610
board over 1 in.(25 mm)glass fiber or mineral
wool hafts without ventilated air space
(c) 0.024 in.(0.61 min),24 gauge sheet utetal over 66 50 12 305 18 457
1 in.(25 unit)glass fiber or mineral wool bans
reinforced with wire or equivalent on rear face
with ventilated air space
(d) 3�j in.(90 mm)thick masonry wail with vendlated 66 — 12 305 — —
air apace
(e) 0.024 in.(0.61 min),24 gauge sheet metal with 66 50 12 305 18 457
ventilated airspace
(f) ':in.(13 mm)thick noncombustible insulation 66 50 12 305 18 457
board with vendla air space -
g0.024 in.(0.61 mm),24 gauge sheet metal with 66 50 12 305 18 457
ventilated air space over 0.024 in.(0.61 mm),
24 gauge sheet metal with ventilated airspace
(h) 1 in.(25 mm)glass fiber or mineral wool batts 66 50 12 305 18 457
sandwiched between two sheets 0.024 in.
(0.61 utm),24 gauge sheet metal with ventilated
air space
Notes:
(1)All dearances and thlcknrencs are"nirmum;larger clearances and thicknesses are permitted.
(2)To calculate the murim tm allowable clearance,the ftillowing formula can be used:Cr,C.x 11-(R/100)1.where Cr is the minimum allowable
clearance,C„is the required clearance with no protection,and Ris the maximum allowable reduction in clearance.
(3)Refer to Figure 13.6.2.1(e)and Figure 13.6.21(f)for other reduced dearannces using materials found in this table.
"See 13.6.1 through 13.6.".
SOLID MTI.SL'RNINC AMJA.%aS 11145
Canbuetibis wed
Do rax toe spaa.s dlracr:y
beh"appwmca Of aonnactes. i+space httwser:
CortSbuitiLN tto'>roAYruStat#Y masonryW
as O spa;lts 0o ribusbNe wa'7
4 iM,002 mm) `.Corti
np twin brick Mae`•" rtte2Jq`'+d
"oft om and kb 00urcP
TOP VIEW of twick stXAtmd tm
_— Str fi t'l heavy-purge steel kv
7d*C suppo t Iv tsec-,-e- `>
WW Gaeran Nato[1J not lace maso uy hie ties d.rtttYlr
rop',u_.�on be!"apcswancs a Co^rt X40
syg'C m.
NarKX)Mbutabls FIGURE; 13.6.2.1(c) Masmtrr C learance Reduction$ystxm.
Matenors arpuna "ll,
the psrinwler`t
t la_(26 nmi)
emonLr o to Aoor,
taegaevtt wombs,
lot air amutaCrxt
lwosn VIEW
PIGL'1i;L 13.6.2.1(a) CloWence Reduction Systern—
iramnwr Location.
10mor,ly wail ey
jwwl
e Goorlm to r*40f
Opu36i.(9s i ar°p°ts
C +� '# Nas«screw
(Y 4 Rm)
b tuiDral4
ter! Plowprombedon 1 f yst r ^M ttt r
t III.(25 WIN networi�ust4it sir such as starred washers.
1 mall-latneW a tubnp of[[Wheal eo t
i in.123 mm) Notes:
rut aPaos sla, (S) Masomy waft can be attached to ownbustibhe waft using wat:twos.
twir4 cl and
t:eh+rxt ctearar� to�,. :a�t. C2i Do not use spacers alrsctN trsrxnd avr>sa'>ce a comsaar.
reoua;,:n system (457—) (467 avn)
FIGURE 13.6.5.1(d) E'asttarr Cletsil.
VIGU'RE 13.6.2.1(b) Ditanec to Cembsadbk%W/T%oos.
Table 15.6.1 %ndwd(3ew aces for'iotid frtel-Uttrning Appilux s
Above Top of Cuing or
Appliance;Abtm"fop
and Nd"of Fornacc
Pkamn or Bonner From Fto w Frost RIMW Dom Sided'
Tj tc of Apptiaace _ is won ai. oust im aan in. arm
P,sdmAW Apptiawis 6 152 48 1219 49, 152b rp 152'
Straus bodlen—15 psi(103 kPa)
Water boners-250`f(121'C)mm
Water boiirtx--2001(9S"C)max.
All crater wailed or jacketed appliances
Frwnwo"
Gravity and rorced air' )8 457 48 1219 18 45' 18 457
/mom 11"0"."ac+s$iow� 36 914 iki 914 Sri 914 96 914
Room E&4w1Fmpttou Unt Ckohnatwns.Rartgat Faio6 Side Oppositt We
Uned fire chamber 9Q' 762° 36 914 24 610 18 457
Unfined fire chamber 30a 762' 96 914 36 914 18 457
` muioru for fuel twragc mutt be touttd at kart 35 in.4914 two.)from any tidy of tic appliance,
sAtIftJO a deatauce for rtontinq and maintcnanct rnrAst be provkk&
`For drArawes from air dtw t%Are NFPA 9011,
b(2taraner to combinable tuterial or metal cabinets.If the underside of suich combosdble material or mcW cabinet is prtxextrd With sheet meld of
nrx tex.tinn 24 poge i0.024 in,(0.61 mtn)j,siw ed wa 1 in.(2:7 nun),the di#ance u prrnntt r!w be rrd u M a.nrx less than 24 in.(610 tnm).
Studrd text=Pe ixi w 0 Text drk6cw&s a,d figwr!rablr reviti mt •=Sertien&Aed xu. X-Nex a atrrial 2018 f d*"
C.Clearances to Combustibles
Minimum Clearances to Combustible Materials
Note:A.C and F Dimensions are to the center of the flue collar
Installation:Full Wrtical
A a C D E F G H-
A.Appliance Dimensions Single Wad Pipe 18- 14- 26-I/2' 1 14- 15 19.1,2 57-U2" 18"
------------------------- Double Wall Pipe 16' 1 12- 24-112' 1 12- 7- 12' 1 57.1/2- 18-
Installation:90 Degree Elbow off Top of Appltanee through back wall
_ Single Wall Pipe 16' 12 24-Ir 12' 1 15' 19 1R 57-v2 18
Installation:Horizontal Through the Wall
Single Wall Pipe 10' 26.IIT 14-
Alcove,Double 12 18- 38-
Wan Pipe
25-34- For Factory Alcove:5-diameter listed DouWe wait air insulated connector pipe with UL 103 HT listed factory btaft Class A Chmvtey or
654 Min Masonry chrnney Maxinwm depth Alcove shall be no more than 48'(1219 mm)and the referenced Alcove clearances Canada nwst
comply w th CANIULC-5269 M87 for the 6%'factory built cMnmev
'Follow pipe manufacturers clearances as recluired
NOTE:Double w30 pipe clearances are for US installations ONLY Canadian installations must confomt with local code In the absence
+ of local codes you must comply mth the ULC 5627-00 and CANCSA-8365
-'_ 23 1 16- Side View Back walliSidewall
556 min 1B tic.uonw rn.oyr.wa
roo
Figure 3.1-Front View
,.as�ay..
i c
rrwt
+r ra
2SW st-ur
$61 ere xur tslrwr.
s cD caw
>i•� 1
i Top View Corner installation
2514' I i v w-
liSfrM ,� C Drcan
eater alr� OL
d
C."C*- H
Figure 3.2-Side View-Top Vent Figure 3.9-Alcove Cle3r3nces.m for double aa6 pipe arty
Heat Shield Air Space Detail
Scale; V= 1"
X"GWB
1"x 0.5"Dia.
Metal Spacer 1"Stone or Cement
/ Stone replica
2x4 Stud �-G/
3.5"Flathead
Wood Screw
Washers
X"Cement
Backer Board \�
Epoxy
Bonding
From VT Castings Dauntless
Install Instructions
B. Hearth Protection Requirements
FLOOR PROTECTION: It is necessary to install a Type I
floor protector. (Spark & Ember protection ONLY)
Floor protector must be non-combustible material extending 39.3.,E
under the appliance to a minimum of 16'(406 mm i in front of rrnrnmum
glass.and 8"(203 mm)to both sides of the fuel loading door.
Open the door and measure 8"(203 mm)from the side edge
of the opening in the face of the appliance. -See exception.
In Canada,similar floor protection must be provided 18"t457
mm,in front and 8"(203 mm i from the sides and rear of the t6 M
appliance. Figure 3.8 ;FROKTE:WROPENING:
USA
Figure 3.5
Wall Seperating Bedroom and Living Area
7.5" k
-----------
.......... -- ---- - -------------------------- ------
3D.-ens,o.s..d Clearances
— A ft"l—c.
L
7.8"
------------------ - ---
-24.925"—0- 3-8-
23.0625
M Min—
,
16"Min
38
IF
23.01!W-
10" IN.
J
4---r M1 10
10"
Duravent Clearances to Combustibles; 1/2"GWB
Double Wall SS Ceramic Insulated pipe(DuraTech);2"
I"Metal Spacers with Double wall air insulated pipe(DVL);6" 1"Air Space
washers Single wall pipe(DuraBlack);18" 1/2"Cement Board
2x4 Wall I"Stone or Cement
Stone Veneer
Wall Seperati ng Bedroom and Living Area
Truss 1.5"from wall frame
L he"I I 2'On Center
Truss
10"
Floor Joist —
BCI Floor Joists
19.2"C to C
-------------— 4.--- ---------------------- ---- Center of Truss Space
Chimney Support Box
12"42"x 24"Tall 30imensions and Clearances
------- - -- A,AW-1.ci—"ion.
7.8'
Floor Joist
------------------------------ ------------
Truss 4-24.625"— 3'8" .,J-
saw
-
23.0625" 10
�"I,
Ml
16"Min
Floor Joist ----------------------------------------------
------------------------- ---
ne-U
23.0625- 10. 1"Slate or Granite,or 2"ConcreteSK PSI,4'x4'
I Overhang
wood stove Wood Stove Damper
1/4"Steel Plate,W"¢r 4x4"
8"Min 10" IN-
Min 16" 3.5"Dia Pipe
1/2"Cement Board
'A"Plywood
Trim Board
2x6x4'SPF
%"Plywood r
—3'8"— ► Screen
I"air space to
Heat Shield Air Space Detail
Scale; V= 1"
YV GWB
1"x O.S"Dla.
Metal Spacer 1"Stone or Cement
--T[I-r-
/ Stone replica
2x4 Stud
3.5"Flathead
Wood Screw
Washers
X"Cement
Backer Board
Epoxy
Bonding
Edge of Flashing "
16'0"- to be 6"from
Ridge Vent Line8'11.5" '0" � "5"
-------------
16 4I 14'Min
??"Min I Roof Slope-
2-
„
2 Min I+ , Roof
' ._._..------._.--'---'-'--_.---- ---.._ElashlDL........_...__..__.._.---.._.._-:-...........
i
( Vrcas ho
Dauntless
Vw@Une
(Peak) 10 *�:
�,�„ Ridge Vent Line 14'6.5"
A•9"
i
� B.20"
C-30"
i
( u..wae,xrw�
, DuraVentDuraTech r•- ----1
1 Chimney Cap t�arwe j o+ o.
I
Chimney Support
3' 6'2" DW Insulated Pipe,4'
i
--- ------------------ ---------------
Storm�L/�8r
Flashing Hole In roof
sheathing;?'
�*-1-9" 4.25"x 1'2"
Notes, 1 W Insulated Pipe,3''-
1.Top of sub floor to bottom of truss;12'4.5" 2'down roof slope of 7/12
2.Bottom to top of truss at peak,4'10" ; Insulation Shield is 1'9"horizontal distance,
3.MDTC=Minimum Distance to Co stlble _ to outside of 8"Dia pipe,or
DW Insulated Calling ort,2'Tall
•��'• Need 3"to extend into IN space _ 2'1"to center of pipe.
-_-_-_ ------ --�__ --= •-------------------------- ----- --
' ---------------
_ 4" Preatstud
92 5/8"
+4.5"_
rnsu anion Or 8.12125"
Duravent DA - F—4.5"Height at
Dual wall pipe with air space outside of truss
6"MDTC wall GWB
8"MDTC celling(Horizontal Install???)
1"x 0.5"Dia.
12'4.5" Metal Spacer
2x4 Stud
Washers
X"
Heat Shield Air Space Detail Cement
Scale;1'=1" Backer
Board
41 1"Stone
Outside Air Intake
Epoxy or
Bonding Cement
Stone
replica