Loading...
HomeMy WebLinkAboutFIR2014-00035 Final AFA - FIR Permit / Conditions - 1/26/2015 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line (36 ext.352 y Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar St Shelton, WA 98584 1854 FIRE PROTECTION PERMIT FIR2014-00035 APPLICANT: STONEHENGE GARDENS RECEIVED: 10/27/2014 CONTRACTOR: LICENSE: EXP: ISSUED: 12/1/2014 SITE ADDRESS: 470 NE TOONERVILLE DR BELFAIR EXPIRES: 6/1/2015 PARCEL NUMBER: 223024200170 LEGAL DESCRIPTION: TR 17 OF SE PROJECT DESCRIPTION: AUTOMATIC FIRE ALARM SYSTEM FOR 1-502 GROW (SEE COM2014-00135) GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: Zones: Heat Detectors: Wet Chemical?: Sprinkler?: Standpipe?: SQUARE FOOTAGE FEES Monitoring Company: C & R ELECTRIC First Floor: Type Amount Due Amount Paid Monitoring Phone No.:(206) 937-3654 Second Floor: Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Permit Fey $168.50 $168.50 Auto. Fire Alarm Plan Chec $109.50 $109.50 Total: $278.00 $278.00 FIR2014-00035 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES ' FIR2014-00035 CONDITIONS FOR FIR2014-00035 1.) Horn/Strobe on outside of the building and on the inside of the building above the power panel must be operational upon activation of the automatic prinkle em. 903.4.2 X A(alarm, s ervisory and trouble signals shall be transmitted and monitored by an approved NFPA 72 compliant supervisory station. X Install Knox Box on entrance gate for Fire Department Access. 506.1 Contact North Mason Fire Authority Capt. Hicks@ 360-275-6711 x 214 X rov ans shall be on-site for inspection, rovide forAC power lock out per NFPA 72 X isp ay ble or marker) AC power location in FACP FIR2014-00035 Please refer to the following pages for conditions of this permit. Page 2 of 5 OW;`=R/ 13'JILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work-as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structu (s) for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if constructs work suspended for a period of 180 days. PROOF OF CONTINUATION OF WOR IS B MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT PL11 ATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.— 11q1J J � l l Sign t Date G OWNER - RE ESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) FIR2014-00035 Please refer to the following pages for conditions of this permit. Page 3 of 5 _n (n ;0 CONCRETE MECHANICAL MANUFACTURED HOME __I ha __-- Late By z— 0 0 - Footings I Setbacks Ribbons m Gas Piping Interior Date By interior-Date By Date :E O ....------- m 0 Exterw Date By Exterior-Date By Set-top z INSULATION G) 01 Point Load I Isolated Footings Date m Date By Data I SLAB INSULATION FIRE DEPARTMENT -TMENT G) Date By > Foundation Walls Floors Date By Date B Date By Y DECKS m FRAMING Walls Date. By z Date By DaIF- By PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic Date By Date By Type- Date By D.W.1v IDRYWALL Type _n Date B Int Brace Wall Date By mV Date By FINAL IMSPECTION CD m Water Line Fire Seperation m D BY ate Datu By Date I CD 0 Pass or Request Inspect. CD — By Comments LJ of Insp. Fail Date Date Done n (D Ty pe 1 011 li6 0 'hip /I :�f4l 0 (D U) 0 0 0 0 47 0 /goo (D 03 (0 (D 0 CTI 06 rm ZO I _ 00 135 MASON COUNTY FIR20 Id - DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. III, 426 West Cedar Street PO Box 279, Shelton, WA 98584 FlI www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elm44 82-52OQ,4' RMason County Fire Protection System Permit Application Incomplete applications will not be accepted '1 Owner: Stonehenge Gardens, c/o Edward Melillo Phone#: 206-621-8433 Mailing Address: 1001 Fourth Ave, Ste 3200 City: Seattle State: WA Zip: 98154 City. Site Address: 470 NE Toonerville Dr. . State: Zip:Belfair WA 98528 Parcel #: 22302-42-00170 Legal Description: TR 17 of SE Lien/Title Holder: Brian Alexander - Property Owner Address: P.O. Box 1297 City: Belfair State: WA Zip: 98528 Contractor: C & R Electric, Inc. Phone#: 206-937-3654 Address: 919 SW 150th. St., STE A City: Burien State: WA zip: 98166 Contractor Registration#: C RE L E I*415 DW Expiration Date: 3/31/16 Building Square Footage (existing&proposed): lst /2458 2nd / 3rd / Agricultural Grow Facility Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: New System: X Wet Dry Modification: Standpipe: Wet Dry Automatic Fire Alarm: X Fire Pump Hood & Duct: Dry Chem: 0 C T 2 ; } Wet Chem: 426 W. CEDA, UL certified Monitoring company: Phone#: Contractors Bid Price: $ 7,628 C:\Users\blr.MASON\DesktopTAC\Fire Protection System Permit A lication.doc P Y PP Plan Submittal Requirements e Your plan subeitial shall include the following: • Plans shall be on.standard 24"x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces,etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits,devices, and end—of—line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$168.50. A plan review fee will be calculated at 65%of the permit fee(minimum$109.50)and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By- Date: C:\Users\blr.MASON\Desktop\PAC\Fire Protection System Permit Application.doe - I Contractor: Proposal Job Site: C & R Electric, Inc. 919 S.W.150th St_ Suite A Buden,WA 98166-1829 Office(206) 937-3654 FAX(206) 932-8538 Customer Bid Date: 10/3/2014 Stonehedge Sales Person. Michael 470 N.e. Tooervilledrive Belfair WA 98528 Scheduled: Edward Melillo Customer Phone: 2066218433 Customer FAX: Edward@melilola.com Stib iieatltrtg PART# jQty I DESCRIPTION JUNITPRICE ITOTALPRICE SK-5808 1 Silent Knight Up To 127 Points Addressable Fire Alarm Panel $ 901.50 $ 901.50 YA-NP12Al2V 2 12V 12AH Lead Acid Rechargable Backup Battery $ 40,50 $ 81.00 SK-SD505-APS 10 Silent Knight Analog Photo Smoke Head $ 62.25 $ 622.50 SK-SD505-6AB 10 Silent Knight 6'Base For Analog Smokes/Heats $ 7.50 $ 75.00 SK-SD50G-PS 2 Silent Knight Addressable Pull Station W/Key $ 87,75 $ 175.50 BK-P2R 5 2-wire Horn/Strobe,Standard cd, Red $ 48.00 $ 240.00 BK-P2RK 1 2-wire Horn/Strobe,Standard cd, Red,Outdoor with Back Box $ 70.88 $ 70.88 1 Drawings&Plan Review $ 560.00 $ 560.00 Labor 32 Journeyman Hours For Installation Of Above $ 70.00 $ 2,240,00 1 Permit $ 400.00 $ 400.00 1 overhead $ 1,600.00 $ 1,600.00 Sub-Total Parts&Labor $ 6,966.38 Washington State Sales Tax @9.5°6 Grand Total $ 7,628.18 Acceptance of Proposal-The above prices, specifications and conditions are satisfactory and are hereby accepted.You are authorized to do work as specified. Signature(s): Date of Acceptance ' Stonehedge Fire(Original) Page 111 10/2/2014 1231 PM