HomeMy WebLinkAboutFIR2008-00084 Fire Alarm - FIR Permit / Conditions - 10/30/2008 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton, WA 98584 FIRE PROTECTION PERMIT FIR2008-00084 APPLICANT: LADY OF THE LAKES RECEIVED: 10/30/2008 CONTRACTOR: PIONEER FIRE AND SECURITY (360)491-8141 LICENSE: PIONEFS963LC ISSUED: 11/7/2008 SITE ADDRESS: 1085 E PICKERING RD SHELTON EXPIRES: 5/7/2009 PARCEL NUMBER: 221321190340 LEGAL DESCRIPTION: LOT: 3 SP#755 OF G.L.1 & NW NW SEC 33 S 5/42 PROJECT DESCRIPTION: FIRE ALARM GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 5 Flow Switches: Visual Devices: Door Releases: Hood&Duct?: N Dry Chemical?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Zones: Heat Detectors: Wet Chemical?: N Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: AVANTGUARD First Floor: 4,350.00 Type Amount Due Amount Paid Monitoring Phone No.:(800)473-723 Second Floor: Sprinkler System Plan $117.81 $117.81 Auto Fire Alarm?:Y Third Floor;: P y Auto. Fire Alarm Permit $181.25 $181.25 Total: $299.06 $299.06 FIR2008-00084 Please refer to the following pages for conditions of this permit. 1 of 4 CASE NOTES FIR2008-00084 CONDITIONS FOR FIR2008-00084 1.) The firg alarm system is required to be fully monitored by a UL certified monitoring company. X --I I, 2.) Per section 901.2.1 of the 2006 International Fire code, Statement of Compliance. Before requesting final approval of the installation, the installing contractor shall furnish a written statement to the fire code official that the subject fire protection system has been installed in accordance with the approved plans and has been tested in accordance with the manufactures specifications and the appropriate installation standard. Any deviations from the design standards shall be noted and copies of the approvals for such deviations shall be attac ed to the written statement. X This permit becomes null and void if work or construction authorized is not oommenoed within 180 days,or if oonstruction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The ownerorthe agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and stru ture for review and in ection. OWNER OR AGENT: DATE: U FIR2008-00084 Please refer to the following pages for conditions of this permit. 2 of 4 MASON COUNTY FIRE MARSHAL - Mason County Bldg. III 426 W Cedar St PO BOX 186 Shelton,WA 98584 (360)427-9670 Ext.273 Permit # Mason County Fire Protection System Permit Application � / Incomplete application will not be accepted Owner: Phone#: �j Mailing Address: 1j City: State: Zip: Site Address: j • 'Pld(f-j/ City: State: Zip: Parcel #:aa I ]!)ajjg1 03yb Legal Description: LN-'. Lien/Title Holder: Address: City: State: Zip: Contractor:Pill-,K Fv,�-�,p L,-r i C ,Phone #: Address: ei) boy 5q� City: t(,�State: -�/VZip:� Contractor Registration #: �)('�N Q 19� b, Expiration Date: (-D I Building Square Footage(existing & proposed): Ist 2nd / 3rd / Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet Dry New System: Standpipe: Wet Dry Modification: AFA: Hood & Duct: Dry Chem: Wet Chem: Fire Pump: UL certified Monitoring company: Phone #:0 4-73-1�3 Contractors Bid Price: $ \\CLUSTERI_HOME_SERVER\HOME\COMMON\BUILDING\Fire Protection System Permit Application_doc Plan Submittal Requirements Your plan submittal shall include the following: • Plans shall be on standard 24" x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls, partitions, stairway enclosures, concealed spaces, etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits, devices, and end —of— line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$157.50. A plan review fee will be calculated at 65%of the permit fee and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By: Date. C4 U \\CLUSTERI—HOMES ERVER\HOME\COMMON\BUILDING\Fire Protection System Permit Application.doc ii3 sii.r.,NT Global Project values: Project Name:FLady of the Lakes Standby Hours:KNIGHT 24 Project ID:I Alarm Mins:�� Prepared By: Bob Leech Derating Factor: 1.2 5700 Calculations Date: 10/30/2008 Voltage Drop Warning Threshold%: 10 r Panel ID: SK 5700 Model: 5700 Add.Fire Alarm Control Panel Max NAC Current: 2.5 Amps Location: Sales Area Handicap Entr. Volts: 24 VDC Max Panel Current: 2.5 Amps Ckt.# Circuit Name Qt Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL 5700 5700 CTRL Panel 1 0.206 1 0.356 SLC-DEV Addrsbl SLC Devices 24 0.013 0.013 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0 0.000 0.000 5496 Power Expander 0 0.000 0.000 5865-4 LED Annunciator(4G) 0 0.000 0.000 5865-3 LED Annunciator(3G) 0 0.000 0.000 5880 LED Driver Module 0 0.000 0.000 Other 0 0.000 0.000 Other 0 0.000 0.000 SD-Duct Duct Hsg w/Relay 0 0.000 0.000 5883 Relay Module 0 0.000 0.000 PGM-1/0#1 Notification Appl Circuit 0.000 0.607 #16 Solid 1 4.02 250 2.01 22.78 5.08% PGM-1/0#2 Notification Appl Circuit 0.000 0.479 #16 Solid 4.02 250 2.01 23.04 4.01% Aux Power *1 #of NAC's Used 0 a000 0.000 Total Standby Current(Amps) 0.219 1.455 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 5 Mins Total Standby AH Required 5.261 0.121 Total Alarm AH R22uired Total Combined AH Required 5.38 Command Shortcuts Multiply By The Derating Factor 1.20 r - Minimum Battery AmpHours Required 6.46 Configure Circuits Print Page *1 A value must be entered if you have selected any NAC circuits as AUX Power. July 15, 2004 DF-50673• F-850 • Fi re•LITe®ALdrms 302 Series Rate-Anticipation Heat Detectors www.firelite.com Section: Conventional Initiating Devices GENERAL California State Fire The Thermotech 302 Series rate-anticipation heat detec- �C ° Marshal tors operate within a controlled range of two to three de- ° 7270-0021:001 grees of their set points, regardless of the speed or rate of LISTED APPROVED (All) temperature rise. These detectors are available in either J.1.5H3M3.AY 135'F or 194'F ratings. S539 E35018A The 302 Series are normally-open devices designed es- pecially for fire detection and alarm systems. FEATURES • Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting,eliminating the thermal time lag inherent in conventional heat detectors. • Eliminates false alarms.The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Model 302 Model • Universal application. The 302 Series can be used in all areas for any type of occupancy. • Self-restoring. • Hermetically sealed,shock resistant, corrosion resistant, and tamper-proof. PRINCIPLES OF OPERATION The 302 Series rate-anticipation heat detectors re- spond and activate the fire alarm immediately when- Model 302-EPM ever the ambient temperature reaches the preset temperature setting. Under rapid heat rise condi- tions, the rate-anticipation feature enables the de- tector to respond one to three degrees ahead of the setting.At the same time, however, it does not respond to momentary temperature fluctuations be- low the selected protection level, thus eliminating Model false alarms. When temperature drops back down below the protection level, the detector automati- cally resets itself. DIMENSIONS (Model 302) Total overall length:4-1/8" Base diameter:2" APPLICATION INFORMATION ELECTRICAL RATINGS 302 Series detectors have a smooth-ceiling UL rating of Voltage Current 50' x 50' (15.24 x 15.24 meters) and are the only type of 6-125 VAC 5 amps heat detectors having such a rating on both fixed tempera- ture and rate anticipation. The 302-H is designed for hori- 6-25 VDC 1 amp zontal mounting and UL rated for 40'x 40' (12.19 x 12.19 125 VDC 0.5 amp meters). This document is not intended be used for installation purposes. We try to keep our product 'SO 9001 information up-to-date and accurate. ate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms,One Fire-Lite Place,Northford,Connecticut 06472. Phone:(800)627- 3473, Toll Free FAX:(877)699-4105,FAX Back:(888)388-3299 ENGINERING 8 MAMUEACf1iING WEB:wVw,v.firelite.com DF-50673•07/15/04 — Page 1 of 2 I PRODUCT LINE INFORMATION Thermotech Model 302 Series Rate-Anticipation Heat Detectors MODEL NUMBER DESCRIPTION REFER TO 302-135 135°F Interior Vertical Mounting, FM and UL. Note 1 below. 302-194 194°F Interior Vertical Mounting, FM and UL. 302-AW-135 135°F All-Weather Vertical Mounting, FM and UL. Note 2 below. 302-AW-194 194°F All-Weather Vertical Mounting, FM and UL. 302-ET-135 135°F All-Weather Vertical Mounting, FM and UL. Note 3 below. 302-ET-194 194°F All-Weather Vertical Mounting, FM and UL. 302-H-135 135°F Interior Horizontal Mounting, FM and UL. Note 4 below. 302-H-194 194°F Interior Horizontal Mounting, FM and UL. 302-EPM-135 135°F Explosion-Proof Mounting, UL.. Note 5 below. 302-EPM-194 194°F Explosion-Proof Mounting, UL. AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. Note 1: For interior mounting in any atmosphere that is compatible with terminal screwtype connections. UL rating 50'x 50' (15.24 x 15.24 meters). Note 2: Humitically sealed for moisture-proof or dust- proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THW' or equivalent type wire. Note 3: Humitically sealed for moisture-proof or dust- proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. Note 4: Same as model 302 except designed for hori- FINE SILVER zontal mounting. UL rating 40' x 40' (12.19 x CONTACT POINTS 12.19 meters). EXPANSION STRUTS Note 5: Explosion-proof for installation in hazardous lo- cations. Has hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attach- HIGH EXPANSION ment to threaded hub cover of Series JL fixture SENSING SHELL 0.040 fitting as manufactured by Killark Electric Co., or ANODIZED ALUMINUM equal. HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Cut-Away View, ACTUAL SIZE Page 2 of 2 — DF-50673•07/15/04 INTELLIKNIGHT ACCESSORY SD500-AIM & SD-500-M I M Addressable Input Modules � IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description • Up to 2500 ft wiring distance from - - -- The SD500-AIM and SD500-MIM are either input module to contact addressable input modules for use with • Use up to 14 gauge wire the Intelliknight fire alarm control • UL listed panels(FACPs).The SD500-AIM addressable input module mounts to a Electrical Specifications 13= 4"-square box.The SD500-MIM mini Standby Current: 0.55 mA input module fits inside a single gang Alarm Current: 23 mA max for one box. Both input modules are designed device;46 mA max for two devices; to be used with pull stations, water flow SD500-AIM 0.55 mA for each additional device switches, and other applications requiring dry contact alarm initiation Line Resistance: 500 max devices. Mechanical Specifications These modules are supervised, single SD500-AIM Physical Description 441kopl input contact monitors. Using an EOL Dimensions: resistor,they monitor for alarm contact 4.9"W x 4.9"H x 1"D closures and for open circuit wiring (12.4 W x 12.4 H x 2.5 D cm) fault conditions. If a fault occurs in the Weight: 3.6 oz(120.1 g) SD500-MIM wiring, the module alerts the FACP. Color: Ivory cover plate Each addressable input module is Approvals programmed with a unique signal line SD500-MIM Physical Description NFPA 71 &NFPA 72 circuit(SLC)loop address. Dimensions: UL 864 1.5"W x 2.5"H x 0.7" D CSFM 7300-0559: 132 Features (3.8 W x 6.4 H x 1.8 D cm) MEA 429-92-E Vol. IX • Single contact monitor Weight: 1.6 oz(45.4 g) FM Approved for use with the 5820XL • Support for Class A(Style 6&Style Environmental 7)or Class B (Style 4)wiring Operating Temperature: • Attractive ivory cover plate with the 32°F— 120°F (0°C—49°C) S D500-AI M • Small and lightweight size allows for Humidity:o flexible mounting options with the 10/o—93/o non-condensing SD500-MIM SILENT • DIP switch programmable for fast KNIGHT" installation 0 by Honeywell INTELLMNIGHT ACCESSORY SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate . t . To o tacl i be monitaeu EOt. ' Jul Wbiny is Supcnnsetl g Power laniteC j 1,7k f EOL 0 I o � 4-: y t La Compatibility Ordering Information IntelliKnight 5820 FACP SD500-AIM Input Module IntelliKnight 5808 FACP Addressable input module with ivory IntelliKnight 5700 FACP cover plate. SD500-MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350231 Rev.C,05/06 subject to change without notice. For more information,contact Silent Knight Copyright©2006 Silent Knight by Honeywell 7550 Meridian Circle Suite 100,Maple Grove,Mn 55369-4927. 9 Phone:(800)328-0103, Fax:(763)493-6475. Addressable Heat Detector IntelliKnight® addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-AHS If the temperature exceeds the trip Addressable Heat point (programmed at the panel), ' an alarm occurs. The status LED Detector lights continuously during the alarm ` The SD505-AHS is a heat detector period. ° suited to virtually any commercial Under normal conditions, the status setting. The SD505-AHS is an LED blinks approximately eve 15 ` absolute temperature device. This t every seconds, indicating that the head is means that it responds in alarm if communicating with the loop. the temperature goes above the trip point (programmed at the Features panel). - Low profile, 2 inches, including SD505-AHS Heat Detector The SD505-AHS provides accurate base Specifications temperature measurement data to - Absolute temperature device Operating Voltage: 17 to 41 VDC the fire alarm control panel. This - Simple and reliable addressing Current Consumption: heat detector is particularly suited Standby: .55 mA to environments where smoke Uses digital communication prOtOCOI Alarm: .55 mA detectors cannot be used because of the presence of steam or - The SD505-AHS is UL Listed Detection Temperature d p Range: 135°F to 150°F cooking fumes, such as in a and meets the requirements (57°C TO 65°C) kitchen. outlined in NFPA 72 Inspection Ambient Temperature: 329F to 1209F Testing and Maintenance, (04C to 494C) Operation Chapter 7. Mounting: 4"SOR,4"OCT The SD505-AHS unit is made up of . CFSM listed Single gang mud an externally mounted thermistor ring with a specially designed cover that MEA listed protects the thermistor while - FM approved Rated Spacing: 70'between sensors on smooth allowing maximum air flow. The ceilings. thermistor reads the temperature SILENT Compatible Bases: SD505-6AB from the air it takes in. It then (Sold Separately) (6"Base) transmits a signal representing the KNIGHT SD505-4AB temperature to the IntelliKnight (4°Base) panel. by Honeywell INTELL11KNIGHT ACCESSORY Model SD505-AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AIS Ionization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Diameter=5-15/16" Diameter=3-15/16" ® [a Height=2 inches, _ including base J i�w��ctrr Model SD505-6AB Detector Base Model SD505-AHS Detector Head (Front View) (Front View) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350229 Rev B,.05/05 subject to change without notice. For more information,contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100,Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone:(800)328-0103,Fax: (763)493-6475. INTELLIKNIGHT ACCESSORY Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment.And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS The light received is converted into Analog /Addressable an electronic signal. Under normal . Photoelectric Type conditions the status LED blinks Smoke Detector approximately every 15 seconds, The SD505-APS is particularly S indicatingthat the head is .r► suited to detecting dense smoke communicating ating with the loop. The k typical of fires involving materials LED lights continuously during the - such as soft furnishings, plastic, alarm period. foam or other similar materials Features which tend to smolder and produce . Low profile, 2 inches, including SD505-APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17-41 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely(using the . Built-in fire test feature Alarm: .55 mA WindowsTM based downloading Ambient Temperature:32°F to 120°F software). • Simple detector calibration p p (0°C to 49°C) testing through the control panel Operation or remotely through a Mounting: 4"Square, 4" The SD505-APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal-resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light . Field cleanable Air Velocity: 0-300 FPM from the pulsing light source. In the . UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505-6AB detector and light is reflected from (Sold Separately) (6" Base) the smoke particles to the receiving • CSFM approved SD505-4AB element. MEA approved (4" Base) • FM Approved SILENT KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Type Smoke Detector % ' Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector P Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. 14 Diameter=5-15/16" 04 Diameter-3-15/16" ICI S, / 0 (j / ® Height=2 inches, including base s�ayr _ a Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350225 Rev C,.05/05 subject to change without notice. For more information,contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. Copyright©2005 Silent Knight Phone: (800)328-0103, Fax: (763)493-6475. INTELLIKNIGHT AC •- SD500-PS and SD500-PSDA a Addressable Pull-Station IntelliKnight's addressable pull stations smut combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated contacts. Addressable Pull • Reflective label makes it easier Station to locate in low light The SD500-PS is a single action Operation addressable fire pull station, and The SD500-PS/PSDA single action the SD500--PSDA is a dual action pull stations are operated by a pull addressable fire pull station. The on the front pull cover of the SD500-PS/PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500-PS/PSDA is down and can be seen up to 100 designed for indoor use in non- feet away. The pull station is reset explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold-plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same PS/PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32°F to 120°F • UL Listed communicating with the loop. The (o°C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS-SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) Specifications • Surface mount back box Operating Voltage: 24VDC SILENT available Standby Current: .55mA • Terminals - accept up to 14 Alarm Current: .55mA KNIGHT gauge wire A0k-, 4 INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FRCP w S�1 �.... i"w, � NO r . �.�.• {. �:..._..._r � I'y §,�', .,f soe�w.cs sic.�r��n s��.. &lC-m3JrCASiC- Wiring s g Optional Mounting to O Mounting to Single P Gang Electrical Box Surface Mount Box i SD500-PSDA Installing SD500-LK Dimensions SILENT KNIGHT A EMb OMW C&TC.Q.fO 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350342,Rev.09/03 FAX:763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2003 Silent Knight INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight' Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description RS-485 bus provides communication 's 5700 performs drift compensation and to system accessoriesI,� calibration checks on each of the Upload or download programming, sensors in the system. event history, or detector status The basic IntelliKnight 5700 system onsite or from a remote location can be enhanced by adding modules using a PC and 5660 Silent Knight such as 5860 remote annunciator, Software Suite (SKSS) 5824 serial/parallel printer interface Improvements in SKSS deliver five module (for printing system reports), times faster upload/downloads and 5496 intelligent power module. Built-in RS-232 interface for 5700 also features a powerful built-in programming via PC dual line fire communicator that allows Built-in Form C trouble relay rated at for reporting of all system activity to a 2.5A at 27.4 VDC remote monitoring location. Two built-in Form C programmable Features relays rated at 2.5A at 27.4 VDC • Programmable date setting for • Up to 50 addressable points Daylight Saving Time • Up to 125 zones and 125 output Model 5700 groups Electrical Specifications • Uses standard wire—no shielded or Primary AC: 120 VAC, 60 Hz, 1.5A Telephone Requirements: twisted pair required Total Accessory Load: 2.5A @ 27.4 FCC Part 15 and Part 68 approved VDC • Built-in digital communicator. Type of Jack: RJ31X(two required) • Central station reporting by point or Notification Power: 2.5A @ 27.4 VDC, d power-limite by zone Approvals • Supports Class B (Style 4)and Class Standby Current: 200 mA NFPA 13, NFPA 15, NFPA 16, NFPA A(Style 6 or 7)configuration for SLC Alarm Current: 325 mA 70, &NFPA 72: Central Station; • Distributed, intelligent power Notification/Aux Power Circuits: Remote Signalling; Local Protective • Drift compensation 2.5A @ 27.4 VDC per circuit, Signalling Systems;Auxiliary Protected e power-limited Premises Unit; &Water Delu • 13pve-programmed output cadences g (including ANSI-3.41)and 4 Battery Charging Capacity: 7.0-35.0 AH Releasing Service. Suitable for programmable outputs Battery Size: 7 AH max. allowed in automatic, manual,waterflow, sprinkler FACP cabinet. Larger capacity supervisory(DACT non-coded) • Notification circuits configurable as 1 batteries can be housed in an RBB Class A(Style Z)or 2 Class B (Style accessory cabinet. signalling services. Y), or auxiliary power for resettable, Mechanical Specifications Other Approvals: UL Listed; constant, or door holder power CSFM 7170-0559: 144; • Built-in synchronization for AMSECO, Dimensions: MEA 429-92-E Vol. XVI. Gentex®, Faraday, System Sensors 12.75"W x 15.2" H x 3.4" D and Wheelock®appliances (32.39 W x 38.42 H x 8.57 D cm) SILENT • Built-in annunciator with 80-character Weight: 11.5 lbs. (5.2 kg) 01 KNIGHT" LCD display Color: Red by Honeywell INTELLIKNIGHT FIRE ALARM CONTROL SLC Detectors SLC Modules 5880 LED/10 Module SD505-APS Model SD500-AIM Features 40 LED Addressable photoelectric smoke detector. Dry contact input module for use with outputs,8 normally normally open dry contacts. It features an open dry contact inputs SD505-AIS and one piezo output indicator LED to show alarm status. Addressable ionization smoke detector. x SD500-MIM 5865-3 and 5865-4 SD505-AHS Remote LED Absolute temperature heat detector that Mini dry contact input module is a small Annunciator goes into alarm immediately if the version of the SD500-AIM. For use with pull Features 30 temperature exceeds the programmable trip stations and other normally open dry contact Programmable LED(15 point.Trip point range from 1350E-150°F inputs. red and 15 yellow)outputs and a piezo (0°C-37°C). SD500-ANM sounder.The 5865-4 adds a silence and SD505-6AB Addressable notification module providing a reset switch to the package. Six inch base for use with detector heads single Class A or Class B notification circuit 5883 Relay Board SD505-APS,SD505-AIS and SD505-AHS. on the SLC. Features 10 general purpose Form C relays. SD505-4AB SD500-ARM Used with 5880 module. Four inch base for use with detector heads Addressable relay module that features two 5824 Serial/Parallel Printer SD505-APS,SD505-AIS,and SD505-AHS. Form C output relays. Provides indicator Interface Module LED to show output status. Provides one parallel and one RS-232 serial SD505-6S8 SD500-SDM port for connecting a printer to 5808. Use to Six-inch sounder base for use with existing print a real-time log of system events, sensor and base.Operates in single and Two-wire detector input module.Allows for detector status reports,and event history. multi-station modes and/or as a system the connection of conventional 2-wire Interfaces with building control system. sounder. Requires 2 additional wires for detectors wires the SLC loop. Requires two additional wires for power. power. Miscellaneous Accessories SD505-61B SD500-LIMA short circuit isolator module for SLC 5660 Silent Knight Software Suite Short circuit isolator base for SD505-AHS, devices.When a short occurs on the SLC User-friendly Windows software for remote SD505-APS,and SD505-AIS detectors. loop,it is detected as a trouble,but all SLC programming of 5700s using a PC. Upload SD505-6RB devices protected by the isolator module and view panel account information,event Six-inch relay base for use with existing continue to operate. history,and detector status. sensor and base. Provides one Form C SD500-LED 5670 Silent Knight Software Suite contact. An LED driver capable of driving 80 LEDs End-user facility management software SD505-ADH through the SLC loop. Up to 40 allows viewing of detector status and event Duct housing that detects smoke in HVAC SD500-LEDs can be used per system. history via modem or direct connection. ducts. RB13 S-BUS Accessories Remote Battery Box Accessory Cabinet. Use SD505-ADHR - — rY rY Duct detector base with relay.Provides 5860/R Remote Fire Annunciator if backup batteries are too large to fit into Form C alarm contact. For use with Features the same 80 character backlit LCD FACP cabinet. Dimensions: SD505-APS and SD505-AIS sensors. display keypad and firefighter's key switch 16"W x 10"H x 6"D Compatible with SD505-DTS remote test as the 5700.The system can be fully (406 mm W x 254 mm H x 152 mm D) switch, programmed and operated from any 5860. SD505-DTS SD500-PS/SD500-PSDA 5860 is gray and 5860R is red. Remote test switch that provides remote key SD500-PS is a single action pull station and 5496 Intelligent Power Module operated test function and annunciation of SD500-PSDA is a dual action pull station. A 6 amp notification power expander that detector alarm with SD505-ADHR. provides four additional power-limited notification appliance circuit outputs. L aens wow <krk.� AM sows+aw ad+aams scsos.unn tursw,rm tovsa4w Q 5700 > 5496 SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350392 Rev.D,04/06 subject to change without notice. For more information,contact Silent Knight Copyright©2006 Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove,Mn 55369-4927. g Phone: (800)328-0103, Fax: (763)493-6475. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight GENTEX CORPORATION Iimarter Nion" Commander4 Series Selectable GCC/GCS Ceiling Mount Strobe and Horn Strobe 24 VDC Applications S E R I E S The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The Commander4 offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz or �� w mechanical tone. These tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the ' temporal three alarm mode. Ir � The GC Series has a minimal operating current and has a minimum flash , rate of 1 Hz regardless of input voltage. �� The Commander4 Series comes standard with the 4" mounting plate which , incorporates the popular Super-SlideTM feature that allows the installer to easily test for supervision. The Commander4 also features the CheckmateTM- Instant Voltage Verification feature which allows the installer to check the voltage without Product Listings removing the signal. The GC Series appliances are UL 464 and UL 1971 listed for use with fire C UL US protective systems and are warranted for three years from the date of pur- n •r ««I .promw. a0 MGM aa chase.- L•hd by UNDERWRITERS LABORATORIES,INC. • BFP(City of Chicago) Standard Features • BS+A/MEA#285-91-E • Nominal Voltage 24 VDC • CSFM 7135-0569:122(GCC) • Tamperproof Field Selectable Candela options of 15, 30, 75, 95,115 & 150 7125-0569:123(GCS) • Unit Dimensions: 6 x 2.6 UL 464& UL 1971 Listed •• Prewire Entire System, then Install Your Signals CAN/ULC S526-M87 Listed • Super-SlideTM Bracket - Ease of Supervision Testing Product Compliance • CheckmateTM - Instant Voltage Verification • NFPA 72 • Input Terminals 12 to 18 AWG • Americans with Disabilities Act(ADA) • Switch Selection for High or Low dBA • Switch Selection for 2400Hz or Mechanical Tone • Switch Selection for Continuous or Temporal 3 MEMBER ASSEMBLED IN • Tamperproof Re-entrant Grill THE USA • Synchronize GC Series by using AVSM Series Control Module • Wide Voltage Range 16-33 VDC or FWR • Faceplate Available in Red or Off-White • Surface Mount with the GCSB (Centex Ceiling Surface Mount Box). * t GCS 24 VDC Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela GCC 24 VDC Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Candela Reverberant In Anechoic Voltage dBA @ 10ft. Room dBA Per UL 4641 @1Oft. Notes: •The GC Emergency Notification Evacuation Series is not listed for outdoor use. •Operating temperature: 32°to 120°F (0° to 49° C) • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. •Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see technical bulletin number 014 for more information). Model designations: "P" = Plain (no lettering) 'C" = Ceiling Mount, 'R" = Red Faceplate/"W" = Off-White Faceplate Product Strobe Current Ratings Candela 15cd 30cdc c 150ccl m m A 167mAm m 286mA UL Max m m m mT-- 360mA I 454mA Horn Mode Minimum dBA Minimum dBA Regulated @ 10ft. per @ 10ft. per Max. Operating UL464(HIGH) UL464 (LOW) @ High Setting (mA) emp J 2400Hz Temp 3 Mechanical Continuous 240OHz ,Continuous ec anica 'Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application. Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. 1 The listed horn current draws are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA @ 10ft. per UL 464 is 77-83 with a horn current draw of 34mA. 2 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting 3. SNAP COVER OVER ASSEMBLY 2. INSERT LOCKING SCREW a 1. SLIDE ONTO BRACKET CheckmateTM Instant Voltage Verification Dip Switch DO 12345 Cam' a � 0 - 0 0 O ® � ® n M s¢ Y REJ WIRES $+ ST $+ O O µ # If 15 O O LM aIFCK WIRES H+ b � � o The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing Switch positions 1 and 2 in the down position to select the device.Typically this would be done at the end of the line to isolated horn and strobe power inputs. Switch 3 confirm design criteria. Most measurements will be taken using selects between temporal or non-temporal tone. Up is the S+ and S-locations although access is provided to other temporal. Switch 4 selects between mechanical or locations. NOTE: Care should be taken to not short the test high frequency tone. Up is mechanical. Switch 5 probes. selects between high or low dBA. Up is high dBA. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed Control SgnalMEND UL Listed Panel Control S+ S+ S H+ H-Panel Signal Signal Supervised S+ S+ S- H+ H- S+ S+ S- H+ H- Signal Circuit Supervised B 0 0 + OF LINE Signal Circuit ISTOR \ END OF LINE 'i RESISTOR \ + END LINE RESISTOR Wiring Diagram GCS/GCC Series with Gentex Synchronization Module F.A.C.P. REvsroR Fort I TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT Cuss n TO NIXf SIGNAL TO NOTIFICATION ALARM CIRCUIT REMOVEJUMPER i FORINDEPENDENT SYNCHRONQED STROBE AUDIBLE SIGNAL } ENO Di LINE AND HORN OPERATION 1Ep}O1^"°a' NEp1 O1R1'N" Re CUSS a� SYNCHRONIZATION CIRCUIT wIRINo oNLr LEAVE JUMPERIN PLACE TO ELIMINATE NEED FOR MODULE LEAVE JUMPER IN PLACE ON ® HORN INPUT ON AVSM SLAVE UNITS UNLESS SEPARATE AND OPERATE SIGNAL CONTROL OVER..RN CKT IN UNISON MODE ® IS REQUIRED. SYNCHRONIZATION MODULE Sgnat Sgna1 S+ S+ S H} F4 S. S. S- H+ H- 0 B B B VISIBLE SIGNAL CIRCUIT i i i RECussa W Rmc ONLY 1 1 ENO OF LINE RE913TOR , , I WIRI ASSA NG ONLY. ' ' j i Note: See Technical Bulletin 015 for proper synchronization module for application. Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1971 for the GCS and also UL 464 for the GCC.The notification appliance shall also be listed with the California State Fire Marshal (CSFM)and the Bureau of Standards and Appeals(NYC). The notification appliance(combination audible/visible units only)shall produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24 VDC for the 15 Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting brack- et with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires. Also the appliance shall be capable of mounting to a sur- face box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 29 pounds per carton Important Notice: G E N T E X These me'smile have been prepared by Gentex Corporation('Gentex)for Informational purposes only,are 551-0051-01 necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and CORPORATION rules.The materials do not address all legal considerations as there Is Inevitable uncertainty regarding Interpretation of laws,regulations and rules and the application of such laws,regulations and rules to pami Fire Protection Products:vwvw.gentex.com ular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for Informational purposes and 10985 Chicago Drive Box 310 is Zeeland, Michigan 49464 should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for 616.392.7195 is 1.800.436.8391 •616.392.4219 Fax any action or failure to act In reliance upon the information contained In this material. Centex corporation reserves the right to make changes to the product data sheets at their discretion. 0 Printed on Recycled Paper GENTEX CORPORATION I i I Outdoor Commander Series WGEC24/ Evacuation Signals WGES24 Applications The Outdoor Commander Series offers dependable visible and/or audible S E R I E S alarms for all outdoor needs. Included with the WGE Series is the GI;E or GOELP outdoor enclosure. The enclosure is made of high quality Lexan material, providing protection from '.._ weather related conditions and allowing the necessary full candela output. This highly constructed enclosure meets various installation requirements including deterring moisture from entering the enclosures. I The Outdoor Series is equipped with the 4" mounting plate which incorporates the Super-Slide-feature that allowes the installer to easily test for ' supervision. The product also features a locking mechanism which ry secures the product to the bracket without any screws showing. The WGE Series also features the Checkmate- - Instant Voltage Verification feature which allows the installer to check the voltage without removing the signal. A The WGE Series strobe has a minimal operation current and has a minimum ' flash rate of 1 Hz and can vary up to 2Hz regardless of input voltage. " The WGE Series appliances are UL 464 and UL 1638 listed for use with fire ; protective systems and are warranted for three years from date of purchase. Standard Features GOELP GOE • Nominal Voltage 24VDC • _ Unit Is Shipped with UL1638 listed WGES24 75 Candela Strobe WGES24 and WGEC24 Shipped or WGEC24-75 Candela Horn/Strobe with the GOE or GOELP • Unit Dimensions: GOE 5.75" High x 4.75"Wide x 4.18" Deep Outdoor Enclosure GOELP 5.75" High x 4.75"Wide x 3.25" Deep • To Obtain Outdoor Horn, Must Order GEH24 and GOE/GOELP Product Listings Separately • Super-Slide' - Ease of Supervision Testing • Checkmate'- Instant Voltage Verification • Lower Installation and Operating Costs • Switch Selection for High dBA LMW OH U1I xF"An"s LA•DPATow",INC. • Switch for Mechanical and 2400Hz Tone • BFP(City of Chicago) • Switch for Continuous Tone • BS+A/MEA#285-91E-XVI • Tamperproof Re-entrant Grill • CSFM 7135-0569:122(WGEC) • Wide Voltage Range 16-33 VDC or FWR 7125-0569:127(WGES) 7300-0569:124(ENCLOSURE) • Separate Horn and Strobe Functions • UL 464 &UL 1638 Listed I • Synchronize Strobe and/or Horn by Using Gentex Synchronization Control Module Product Compliance • Listed for UL1638 when used with the GOE or GOELP enclosure • Americans with Disabilities Act(ADA 4.28.3) • GOE/GOELP Made of Clear Lexa®- Provides Maximum Visibility and NFPA 72 Reliability for effective Visible Signaling -Allowing Full 75cd Output • Input Terminals 12 to 18 AWG �! • Faceplate Available in Red or Off-White UWAS R ASSFM0.FD Mf THE UM • f GEH24 - 24 Volt Low Profile Evacuation Horn Model Number a um er Nominal Rever eran n Anechoic Room Voltage 1Oft. Per UL 4641 dBA @1 Oft. NOTE: Must order the GOE or GOELP separately when using the GEH24 in an outdoor application. WGES24 - 24 Volt Low Profile Evacuation Outdoor Strobe Model designations: "W" = Wall Mount Model Number Part Number Nominal Candela "R" = Red Faceplate Voltage (UL 1638) "W" = Off-White Faceplate _ _ "P" = Plain (no lettering) Plain units are non-returnable. LP"=Low Profile(GOELP Enclosure) WGES24 and WGEC24 shipped with the GOE or GOELP Outdoor Enclosure WGEC24 - 24 Volt Low Profile Evacuation Outdoor Horn/Strobe Model Number Part Number Nominal Candela ever eran n Anechoic Room Voltage (UL 1638) 1 Oft Per UL 464 dBA @ 10ft. Notes: •The WGE Series is listed for outdoor use. Indoor Operating Temperature: 32°to 120°F(0'to 49°C). Outdoor Operating Temperature: -31°to 150°F (-35° to 66°C). •For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. •Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products WGE S_e_r-ie_sPr_o_auct Strobe Current Ratings -C—ande-11'a-1 75cd m UL Max m WGE Series Product Horn Current Ratings orn Mode MinimumMinimum dBA @ 1 Oft. Regulated 24VDC M per UL464 (HIGH) per UL464 (LOW) Operating @ High Setting (mA) emp 3 240OHz emp 3 Mechanical emp 3 Chime Continuous 240OHz Continuous Mechanical Continuous Chime 00 Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These set- tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). Notes:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw,add the strobe current draw and the horn current draw. I RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. i . t . Mounting Super-Slide" �al I ' ' I I I •.r f GASKET Super-Slider" Mounting Plate: Super-Slider" Mounting Plate: Mounts to GOE outdoor box. Mounts to GOELP outdoor box. Checkmate'" - Instant Voltage Verification Switch Locations SWITCH POSITION ---'��-- 3 4 5 f M.mIh c fdrrrp. ON ON ON Mschankal-Corr. OF N ON r` Hi isr p. ON OFF ON HFCom. OFF OFF ON S+ ChimF-Tamp. ON ON OFF chhw-Cont OFF ON OFF ' S+ Whoop ON OFF OFF OFF OFF OFF H+ �}. .I i / Switch positions t and 2 j f In the off posltlon to select isolated horn and strobe power inputs. p The access holes are provided in the back of the terminal OfJ block to allow the voltage to be measured directly without removing the device.Typically this would be done at the end of the line to confirm design criteria. Most measure- ments will be taken using the S+ and S-locations although access is provided to other locations. NOTE: 1 2 3 4 5 6 Care should be taken to not short the test probes. Conventional WGE Series Wiring Diagrams UL Listed UL Listed Control Signal Signal Control Signal Signal Panel Panel S+ S+ S- H+ H- S+ S+ S- H+ H- S« S+ S H+ H- s+ S+ S- H+ H- Supervised B B B B Supervised Signal Circuit Signal Circuit \ + + END Of LME \ END OF LINE RESISTOR RESISTOR \ + END OF LINE RESISTOR Wiring Diagram WGE Series with Gentex Synchronization Module F.A.C.P. U. RESISTOR FOR ' TO N EXTSIGNAL TO NOTIFICATION ALARM CIRCUIT Cuss A WWIIIOONLY. _ TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT REMOVEJUMPER FOR INDEPENDENT SYNCHRONIZED STROBE AUDIBLE SIGNAL i EMDv LINE AND MORN OPERATION Ncw aNn.wH Nmr sun.er. RESISTOR FOR CIRCUIT _ CIASss LEAVE JUMPERIN PLACESYNCHRONIZATION wRINa ONLY. TO ELIMINATE NEED FOR MODULE ® ON HORN INPUT ON AVSM SLAVEVUN UNITS UNLESS SJUMPER IN PLACE ON EPARATE AND OPERATE SIGNAL CONTROL OVER HORN CKT IN UNISON MODE ® IS REQUIRED. SYNCHRONIZATION 00 MODULE Signal Sig at S. S. S. H. H- S. S+ S. H+ H- B B 0 B ENOOFLNE VISIBLE SIGNAL + I I I RE SISToa FOII CIRCUIT i i i cusv e wrsNa aNLr I I I I I i 1 i I 1 I I 1 I I ---------------' ------------------- ----------------------------------------------------------------------- i RESISTOR Fpt I I CUawOeA ILO wxt aNLV. - Note: See Technical Bulletin 015 for proper synchronization module for application. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex WGE Series or approved equal and shall be listed by Underwriters Laboratories Inc.per UL 1638 and/or UL 464.The notification appliance shall also be listed with the California State Fire Marshal(CSFM)and the Bureau of Standards and Appeals (NYC). The notification appliance(combination audible/visible)shall produce a peak sound output of 100clBA or greater at as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 112mA or less for the 75Cd strobe circuit. The appliance shall also be capable of meeting the candela requirements of the ADA(75cd). The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models. The appliance shall be capable of testing supervision without disconnecting wires.Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. The appliance has extended temperature range of-31 o to 150OF(-35o to 66'C). The appliance shall satisfy virtually all outdoor and severe environment applications. The GOE Enclosure is includes a gasket that must be inserted between the box and mounting bracket. There are drain holes in the back box to allow for drainage,the seal on the GOE Enclosure is not water tight. The GOELP Enclosure includes a weather seal for mounting to wall and intended for use with universal electrical box. To allow for drainage,bottom edge of enclosure is not water tight. 1 unit per carton 3 pounds per carton Important Notice: G E N T E X These materials have been prepared by Gentex Corporation(advice an for should of b el purposes only,Oro 551-0047-02 neceax ma summary,and Oro not andpurported to serve u legal advice and should not be used as such. Gentex makes no roproeentatlona and wamantles,express or implied,that these materials are complete C O FY P O F2 A T 10,N and accurate,up•to-date,or in compliance with all relevant local,state and federal laws,regulations and rules.The materials do not address all legal considerations as there is Inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to partio- Fire Protection Products:www.gentex.com ular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or miss.Therefore,these materials should be used only for Informational purposes and 10985 Chicago Drive Box 310•Zeeland, Michigan 49464 should not be used as a substitute for seeking pmtessional legal advice.Gentex will not be responsible far 616.392.7195 • 1.800.436.8391 •616.392.4219 Fax any action or failure to act In reliance upon the Information contained In this material. Gentex corporation reserves the right to make changes to the product data sheets at their discretion. 0 Printed on Recycled Paper Commander3 Series Selectable GEC3/GE 3 Candela Evacuation Signals 12 & 24 VDC Applications E R I E � The Commander Series is a low profile strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable candela options of 15, 30, 60, and 75 candela. The Commander3 Series horn offers a continuous or synchable temporal three , in 2400Hz and mechanical tone, a chime as well as a whoop tone. All tones are easy for the professional to change in the field by using switches. i The GE3 Series has a minimal operation current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander3 Series is shipped with the standard 4" mounting plate which Product Listings incorporates the popular Super-S1ideTM feature that allows the installer to easily test for supervision.The product also features a locking mechanism which secures the product to the bracket without any screws showing. 14 C UL US Ths syMW W.th•pmducr•MMOPIete rUWS n ie The Commander3 also features the CheckmateTM- Instant Voltage Verification Ustod W UNDERWRITERS LMORATOA JIM INC. feature which allows the installer to check the voltage without removing the sig- • BFP(City of Chicago) nal. • BS+A/MEA#285-91-E • CSFM 7135-0569:122(GEC3-24&GEH-24) The GE3 Series appliances are UL 464 and U pro-1971, listed for use with fire 7125-0569:129(GES3-24) 7125-0569:129(GES3-12) tective systems and are warranted for three years from date of purchase. 7135-0569:130(GEC3-12&GEH-12) Standard Features • UL 464&UL 1971 Listed • CAN/ULC S526-M87 Listed • Nominal Voltage 12 & 24 VDC Product Compliance • 24 VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela • 72 • 12 VDC units have field selectable candela options of Americans icans with Disabilities Act(ADA) 15, 30, 60, and 75 candela • GEH horn is available in 12 or 24 VoltX F" • Unit Dimensions: 5' high x 4.5"wide x 2.5" deep M A54EM•LEDM • Prewire Entire System, Then Install Your Signals 'SUS` • Super-SlideTM Bracket- Ease of Supervision Testing • CheckmateTM - Instant Voltage Verification • Surface Mount with the GSB (Gentex Surface • Lower Installation and Operating Costs Mount Box) • Input Terminals 12 to 18 AWG • Synchronize Strobe and/or Horn with AVSM Series • Switch Selection for High or Low dBA Control Module (12 Volt product must use the AVSM • Switch for Chime, Whoop, Mechanical and 2400Hz Module). Tone • Silence Horn While Strobes Remain Flashing • Switch for Continuous or Temporal 3 (not available on • Wide Voltage Range 8-17.5 VDC (12 Volt Models) whoop tone) 16-33 VDC or FWR (24 Volt Models) • Tamperproof Re-entrant Grill • Faceplate Available in Red or Off-White GEH 12 or 24 Volt Low Profile Evacuation Horn Model um er Part Number Nominal Reverberantn Anechoic Room Voltage 1Oft. Per UL 4641 dBA @1Oft. GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe Model um er Part Number Nominal Candela Voltage (UL 1971) Model designations: "W" = Wall Mount "R" = Red Faceplate "W"= Off-White Faceplate "P" = Plain (no lettering)Available with all models. These units are non-returnable. "Agent" bezel also available. GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn/Strobe Model um er Part Number Nominal Candela Reverberant dBA @ In Anechoic Room Voltage (UL 1971) 1Oft Per UL 4641 dBA @ 1Oft. Notes: •The GE3 Series is not listed for outdoor use. •Operating temperature: 32°to 120°F(0°to 49'C). •For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12 volt models are DC only. •Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). Product roe Current Ratings Candela cd 60EU__T___79_cd_ GE3-24 ProductStrobe Current Ratings 24 VUL; lUbMA 131MAm m Candela 15cd 30cdc c c UL max, m m m mT— 24VUL; 55MA WMAm m m GE3-12 ProductHorn Current Ratings ULmax, /8MA 96MA 131MA 180MA 224rnA ro uc Horn Current Ratings Horn Mode Minimum minimumRegulated dBA @ 10ft. dBA(a 10ft. 24VDC Max. Horn Mode Minimum Minimum Regu a e per UL464 per UL464 Operating @ dBA @ 10ft. dBA @ 1Oft. 24VDC Max. (HIGH) (LOW) High Setting(mA) per UL464 per UL464 Operating Temp 3 240OHz (HIGH) (LOW) High Setting(mA) Temp ec anica emp z emp 3 Chime emp 3 Mechanical Continuous z 29 iemp I unime Continuous Mechanical 72* 26 ­17on muous 240OHz 28 Continuous ime on muous Mechanical WhoopContinuous ime 15 Whoop Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for pub- lic mode application(not applicable when using the chime tone.The chime tone is always private mode). Notes:The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw,add the strobe current draw and the horn current draw. The listed reverberant dBA are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA® 1 Oft.per UL 464 is 77-83 with a horn current draw of 34mA. RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Mounting Super Slide'" Switch Locations SWITCH POSITION 3 4 5 Mechanical Temp. ON ON ON / —Mechanical-Cont. OFF ON ON Temp. Hi Temp. ON OFF ON Qa Hi-Cont. OFF OFF ON Chime-Temp. ON ON OFF S Chime-cant OFF ON OFF Whoop ON OFF OFF a Whoop OFF OFF OFF ei IE�`p Switch Position 6 14s III ® ON>HIGH dB to OFF>LOW dB / Switch positions positio 1 o s 2 .q in the off position to salad isolated horn and strobe power inputs. y Die Cast Metal Mounting Plate: Mounts to single gang, double gang 4"square boxes or GSB box. ON L i N. Checkmate" - Instant Voltage Verification � 12 3 4 5 6 S+ Candela Selection S+ S. H+ R Candela selection slidjh switch. Depress cent and slide switchto des brightness lave. s The access holes are provided in the back of the terminal Break off pin and insertblock to allow the voltage to be measured directly without hole at the be nd of tuseledorto lode candela sra removing the device.Typically this would be done at the Signal must be removed ,Tabracket and pin pushed f uIctlonend of the line to confirm design criteria. Most measure- from backside out of t maker ments will be taken using the S+and S-locations to change candela. although access is provided to other locations. NOTE: Care should be taken to not short the test probes. Conventional GES3/GEC3 Series Wiring Diagrams UL Listed UL Listed Control Signal Signal Control Panel Panel spool signal S+ S+ S_ H+ H_ S+ S+ S_ H+ H_ s+ S+ S- H+ H- s+ s+ s H+ H. Supervised B IS 0 0 Supervised p Signal Circuit Signal Circuit + + \\ - END OF RE END LINE RESISTOR 01 \ + END OF UNE RESISTOR Wiring Diagram GE3 Series with Gentex Synchronization Module F.A.C.P. ENO OF LJNE _ ______________________________________ REal—FOR I TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT Class♦ i wIRND ONLY. ........................................ i TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT REMOVEJUMPER FORINDEPENDENT SYNCHRONIZED STROBE AUDIBLE SIGNAL • RENO OF LINE AND HORN OPERATION xcav arrx.w• rmr artl•w.. ESIST011 F_ CIRCUIT cuss e SYNCHRONIZATION - W1RRI0 ONLY LEAVE JUMPERIN PLACE TO ELIMINATE NEED FOR MODULE LEAVE JUMPER IN PLACE ON HORN INPUT ON AVSM SLAVE UNITS UNLESS SEPARATE AND OPERATE SIGNAL CONTROL OVER HORN CKT w .N IN UNISON MODE IS REQUIRED. SYNCHRONIZATION MODULE Signal signal S+ S+ S- H+ H- S+ S• S H+ H- B B B (S)II END OF UNE ' VISIBLE SIGNAL � I i 1 I RESIsioR coo CIRCUIT i i i CLn93e WIWr10 ONLY I 1 1 I 1 I I I I i I ENO of UNF _________________------ ._t_t---------------.---------------------------------_--------------_---------------------------------- � i RESIattM FOR � I 1 , , C A i t I Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GE3 12 VDC Series,the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc.per UL 1971 and/or UL 464.The notification appliance shall also be listed with the California State Fire Marshal(CSFM)and the Bureau of Standards and Appeals (NYC). The notification appliance(combination audible/visible)shall produce a peak sound output of 100clBA or greater at 12 or 24V as measured in an ane- choic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- ity to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models. The appliance shall be capable of testing supervision without disconnecting wires.Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton Important Notice: G E N T E X These necessarily la have been prepared by Gentex Corporation(adviceanfor hind of be purposes only,are GE30201-12 nacessarity summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no repreaentations and warranties,express or implied,that these materials are complete CORPORATION and accurate,up to-date,or In compliance with all relevant local,state and federal laws,regulations and rules.The materials do not address all legal considerations as there Is Inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to partic, Fire Protection Products:wvvw.gentex.com ular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for Informational purposes and 10985 Chicago Drive Box 310•Zeeland, Michigan 49464 should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained In this material. 616.392.7195• 1.800.436.8391 • 616.392.4219 Fax Gentex corporation reserves the right to make changes to the product data sheets at their discretion. 0 Printed on Recycled Paper