Per your request, a site inspection was conducted of the above
described property. The following is a summary of the planning
department' s findings in regards to your proposal to build a single
family residence at this site.
The property falls under an urban residential shoreline
designation. Per this designation, the side yard setback for
structures on this property would be five feet. This setback is
measured from the roofline to all side property lines and applies
to all structures greater than 30 inches in height.
Construction of a new residence must also meet a shore yard
setback. Adjacent homes to the property determine the shore yard
setback. An imaginary line subtended from the furthest waterward
projection of the rooflines on the adjacent residences represents
the shore yard "common line" setback as it crosses your property.
All structures greater than 30 inches in height, including
rooflines should not encroach waterward of this line. (Please
reference site visit on May 18, 1992 / 68 .5 feet measured from
shoreline bulkhead near southwest property line)
In regards to the setback from Mason Lake Drive East, a setback of
5 feet must be maintained from the edge of the road right-of-way.
In addition, new construction on the lot should not exceed a 60
percent site coverage. In other words, the total area of all
impervious surfaces on the lot shall not exceed 60 percent of the
total area of the lot excluding submerged lands.
Also, residence utructures should not exceed 35 feet in height.
Gary Yando,Director of Community Development • Erik Fairchild,Planning Director
Mason County Bldg. III • 426 W. Cedar • P. O. Box 578 • Shelton, WA 98584 • (206)427-9670
Recycled
Page 2
Zirkle.
If the actual building permit for a residence at this location is
not received within 4 months of the date of this letter or by
September 19, 1992 another site-inspection will be necessary to
confirm these setbacks and restrictions.
* Four months is the length of time a pre-inspection
remains valid.
For 'septic system design standards, as well as septic setbacks and
sizing, I would encourage you to speak with John Denison of the
Mason County Environmental Health Department at 427-9670/ext. 361.
If you have any questions regarding the information provided;
please feel free t contact this office at 427-9670/ext. 295 .
Since Fely,
1 _
r
Steve ichols, Sho eline Planner