HomeMy WebLinkAboutBLD2007-00184 Final SFR - BLD Permit / Conditions - 4/18/2008 i r Inspection Line(360)427-7262 t MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 irflo Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2007-00184 OWNER: THOMAS SULEWSKI RECEIVED: 1/31/2007 COIJTRACTOR: DENNYS HOME IMP. 426-3767 LICENSE: DENNYH11973BG EXP: 1/7/2009 ISSUED: 8/9/2007 SITE ADDRESS: 2611 E MASON LAKE DR EAST GRAPEVIEW EXPIRES: 2/9/2008 PARCEL NUMBER: 222335200052 LEGAL DESCRIPTION: MADINGS SUNNY SHORE ADD#6 TR 52 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW SFR HWY 3 TO MASON BENSON RD TO MASON LAKE DR E General Information Construction&Occupancy Information Square Footage Information No.of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No.of Bathrooms: 3 Occ. Group: R/U Lot Size: Deck: 132 Type of Work: NEW Fire Dist.: 5 No. of Stories: 1 Occ. Load: Building:1,339 Garage-Attached 525 Valuation: Building Height: Occ. Status: Seasonal Basement:1,210 cov porch 133 Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: 200.0 Ft. Shoreline: 70.0 Ft. Water Body: Mason lake Rear: 70.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: 5.0 Ft. Shoreline Desig.: Urban Year: Serial No.: Side 2: 5.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee KS 1/31/2007 $1,006.30 S12007000 Floor Drain 2 Fireplace 1 Planning Review Fee KS 1/31/2007 $155.00 512007000 Hosebibs 2 Furnace<100K 1 Address Fee BLJ 2/5/2007 $154.00 S12007000 Kitchen Sink 2 Gas Outlets 2 Building State Fee DLC 2/15/2007 $4.50 S12007000 Laundry Tray 1 Propane Tank 1 Building Permit Fee DLC 2/15/2007 $1,475.35 S12007000 Lavatories 4 Ventilation Fan 4 Mechanical Fee DLC 2/15/2007 $145.95 S12007000 Showers 2 Heat Pump 1 Mechanical Base Fee DLC 2/15/2007 $23.50 S12007000 Water Closets (Toilets) 3 Dryer Vent 1 Plumbing Fee DLC 2/15/2007 $138.00 S12007000 Water Heaters 1 Plumbing Base Fee DLC 2/15/2007 $20.00 512007000 Bath Tubs 1 ADJUST—Plan Check Fee DLC 2/15/2007 -$47.32 S12007000 Clothes Washer 1 EH Plan Review TW 8/2/2007 $75.00 512007000 Total $3,150.28 BLD2007-00184 Please referto the following pages for conditions of this permit. 1 of 4 CASE NOTES FOR B LD2007-00184 CONDITIONS FOR BLD2007-00184 1) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access read. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roadsoofiect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X r� 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-09he person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 3) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department priny further inspections being performed or approvals granted. X 4) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the juri3diction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspections. X 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of T r d documents will result in failure of required building inspections. X 6) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Departmrior to any further inspections being performed or approvals granted. X BLD2007-00184 Please referto the following pages for conditions of this permit. 2 of 4 Ar ' 7) Washington State Energy Code Compliance has been approved using the following: -Heat Type: heat pump with electric furnace, Compliance Method: IV, Window(Max U-Factor):0.4C, Skylight (Max U-Factor):0.58, Doors (Type/Max U-Factor):0. less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10. X ram► 8) Per 2003 IRC - SECTION 1609-WIND LOADS - 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE 1609 BASIC WIND SPEER (3-SECOND GUST)the wind speed for Mason County is 85 MPH. X E 9) Per 2003 ►RC - SECTION R905- REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be applied in accordance wit applicable provisions of this section and the manufacturer's installation instructions. X 10) Any chat ages in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and sp�l a collected by the Building Department prior to any further inspections being performed or approvals granted. X T� 11) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. 12) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. ,r� X 11 13) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulatmust be reviewed and approved by Mason County prior to construction. X 14) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall b1� de prior to requesting additional inspections. X V7 BLD2007-00184 Please referto the following pages for conditions of this permit. 3 of 4 • 15) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must -meetX the installation_requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. 16) A:'- property lines shall be clearly identified at the time of foundation inspection.X 17) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances P�uilding regulations. X 18) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevent on from being taken. No more than one extension may be granted. X ,Q(� 19) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structpre for review and inspection. OWNER OR AGENT: J_ DATE: BLD2007-00184 Please refer to the following pages for conditions of this permit. 4 of 4 co a CONCRETE MECHANICAL MANUFACTURED HOME c o Date Il `Zq/6� By Lo( r 0 Footings acks Z� b j / Ribbons m Gas Piping o Interior Date By Interior-Date �l ZR�l Bye Data By 00 Exterior Date S Z1�j)7 BY-674-- Exterior-Date B -� • A Point Load d Isolated FootingR INSULATION _ Date Uy � BG!SLAB INSULAT DN T Date By Data By FIRE DEPARTMENT 0 FoundaU71s Floors Date ByDat 3 ? B Data BY DECK Cn FRAMINO Walls Date By Date 6f� ay UO� Data - -J By .�J PROPANE TANKS PLUMBING vault Date By Date By V OTHER Ground Attic Typw Date By Data By Date By D.W.v DRYWALL Type: r Int.Brace Wall Date By Date Z( aY BY Date eY T FINAL INSPECTION 0 Water Line ` Fire Separation o Date �7 By Date By Date O Pass or Request Inspect. c Type of insp. Fail Date Date Done By Comments s ��5 5� v_ a7 S Zy j —F> �vi 7 CD a too i o � a Cn =r aim CD c ��- +, 6J 0 fW� ..,. --.^ .s.+.-.+.�to..---"""'�Ri+'.,.. MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION t 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner FATAL/A SU[ WryJ&l Company Name ti Ma in"Address 3 Z z L_ SE' Mailing Address 5S -"J-V j City State Zip Code 2 City ,•j�'� U/ State _ Zip Code ' Phone z53 35 780! Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg.# "PI i9J%i9 Exp. 0/" E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB i SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic, Connect to Water System Name of Water System Well L-,. Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. Z22 352000SZ Fire District Legal Description tM 1)1 1, SIJAI AlY &l4d44-_' 406 /0 _M S2 Site Address(Please include street name, street number and cit ) 'Z 611 kt: Directions to site WI WA`r 3 � —TU / ©-j f5Cr4.Su-1 0 AjUu-1 L.lc J02 EAJt-- Will timber be cut and sold in parcel preparation?Yes/ Is property within 200' of Saltwater Lake „River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs�/a Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New Add Alt Repair Other PRIMARY RESIDENCE ❑ SEASONAL ❑ Use of Building okc"• Describe Work � No. of Bedroom-,-= No. of Bathrooms -75 Square Footage- 1st Floor /-S/ 2nd Floor 3rd Floor Basement Deck ' Covered Deck Z 2t/ Other Sq. ft. Garage 5� Attached Detached Carport Attached Detached MANUFACTURED HOM I E.JNFORMATION - Make Model Year Length Width S I No. No. of Bedrooms No. of Bathrooms Type of Heat PuN4,ase Price$ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is b)r signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFAP GRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X & Date: 'owner/Own epresentative Contractor (indicate which.one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by:�& Date DEPARTMENTAL REVIEW P OVED DENIED NOTES Building Department r a? •JIF-0 fa Planning Department '� j Environmental Health Department Fire Marshal FEES Building Permit Fee 4 7 .S. 3 Site Inspection Plan Review Fee 3 2 P 4 EH Review Fee Plumbing & Base Fee Planninq Review Fee Mechanical & Base fee Other su Wood /Gas/ Pellet Stove Fee State Fee Violation Fee 0 Pre-Paid at Submittal Valuation $ /gam yo?S•S� TOTAL FEES i X � - Is �'� 7 q-9) PERMIT NO. MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467• Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR IRFORMA�TION f AT/� s/�fr✓ft Owner,� / Company Name Mailing Address2621 Z .I't� Mailing Address City 4UfV1? State z41A Zip Code 40g Z City I•�(//64�j State _ Zip Code 019-31'in Phone253l?S' 8 Other Ph. Phone y 2 t ;76 Other Ph. Lien/Title Holder Contractor Reg.4 Exp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic_ Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 Digit Parcel No. oUo.SZ Fire District Legal Description ,-fi4aN6 J(IIVA t S,4 4'& 19A90 [, W-6 Z Site Address (Please include street name, street number and city) 2�6/f /N•4 404 LC 0 Z "x t-- Directions to site Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building /cc Location of Fixtures/Units - 1 st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric_ LPQ_ Natural Gas_ Heat Pump_ Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace '. T"o 48ath Tubs Heatpumps / 16. 65 c»dooC/ Showers 41 Spot Vent Fan c A 5- Water Heater Propane Tank ,Clothes Washer X �33 Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove •3U Dishwasher S Kitchen Exhaust Hood 7 — /o Hosebibs —fir r�ech Dryer Vent Other Other i¢i- / Base e a Base Fee TOTAL PLUMBING TOTAL MECHANICAL o OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X A : _ Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND HIS RINT Accepted by: Planning I'd Ck# Date - Bld Pd Receipt No. DEPARTM NTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group—Type Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee-'/ '� Other Violation Fee TOTAL FEES