HomeMy WebLinkAboutBLD99-00155 Cancelled Garage - BLD Permit / Conditions - 3/5/2003 MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 Er U I L. D I N G P F7 P M II T FOR INSPECTIONS G 427-9670 BETWEEN 5pm AND Bain 427-7262 BLD99--0155 PARCEL :222335200034 PLAT :MAPLO DIV : BLK LOT : JOB ADDRESS : 2381 E MASON LAKE DR E GRAPEVIEW prQtaNl OWNER : TROY THOMAS 253-936-•6520 1T CONTRACTOR : ALL NEW GLASS INC 253-735-1308 ,,Y EXPIRAT��N LEGAL : NAOINGS SUNNY SNORE ADD I6 TA 31 & VO��" CLASS OF WORK :NEW BEDR : 0 .BATHs 1 TYPE AMOUNT FY DATE RECEIPT TYPE niaLINT BY DATE RECEIPT TYPE OF USE . . . . :ACC STORIES . . . . . . . s2 — � _ -- =-:.----- — _� OCCUP . GROUP . . . :U 1 BLDG . HEIGHT . . : 0 .Oft PLCK 1 233.19 KW 03112199 49655 TYPE OF CONST . . :5N F I REPLACES . . . . : 0 PONT 1 358.75 KS 65103/99 50146 OCCUP . LOAD . . . . : 0 WOODSTOVES . . . . : 0 SIFE 1 4.51 KS 05/03;99 50146 DWELL .UNITS . . . . : O� PARKING SPACES : 0 ENA.P 1 51.60 KS 05103199 50146 i INSPECTION AREA : 2 SHORELINE? . . . . :N 110TAL: 646.44 VALULATION: 254581 'TOILETS . . . . . . . . . . : 1 FUEL TYPES----__.-_-_-.- BOILERS/COMP---- MOBILE HOME_ FRONT . . .E 160 .Oft BATH BASINS . . . . . . : 1 : /L_PG/ ! ! 0- 3 HP . - 0 REAR . . . .W 120 .Oft BATH TUBS . . . . . . . . : 1 3-15 HP . : 0 MODEL : SIDE ( 1 ) .N 5 .5ft SHOWERS . . . . . . . . . . . 0 FURN < 100K BTU : 0 15-30 HP . % 0 .-IAAKE- -- SIDE (2 ) .S 5 .5ft WATER HEATERS . . . . : 1 FURN ->-100K BTU : 0 30-50 HP . : 0 SHRLINE .W 120 .Oft CLOTHES WASHERS . . : 0 FURN - FLOOR . . . . 0 50+ HP . : 0 --YEAR- - ----- - AREA --- ------------- KITCHEN SINKS . . . . : 0 HEAT PUMP . . . . . . : 0 LOT SIZE . . : FLOOR DRAINS . . . . . : 0 VENT SYSTEMS . . . : 0 EVAP COOLERS : 0 LENGTH : 0 BUILDING . . . .- 102.0sf DRINKING FOUNT . . . s 0 VENT FANS . . . . . . : 1 HOODS . . . . . . . : 0 WIDTH . : 0 BASEMENT . . . s 0sf LAUNDRY TRAYS . . . . : 0 DOMES . INCIN :O --SERIAL#-- - -- DECKS . . . . . . . Osf DISHWASHERS . . . . . . : 0 AIR HANDLING UNITS-- COMML . INCIN :O GAR/CARP :G 560sf GARB DISPOSALS . . . : 0 <= 10000 cfm . : 0 RELGC/REPAIR : 0 AT/DT . :? URINALS . . . . . . . . . . : 0 10000 ,,:fm . : 0 OTHER UNITS . : 0 MISC PLM FIXTURES : 0 GAS OUTLETS . : 0 PROJECT 9ESCIIPTION:6A1AG PROJECT LOCA1ION:HWY 166 NEST TO TRAILS RD RIGHT ON MASON BENSON RD. , III4T ON MASON LAKE 11 E APPROX !14 NILE ON LEFT. THIS PERMIT BECOMES NULL AND VOID Ir WORK OR CONSTRUCTION AUTHONIZ13 IS N.OT 'C .MNENCEf) WITHIN 181 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED F01 A PL4 100 OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. EVIDENCE Of -CONTINUATION Of-iNRK IS A PA04RESS INSPECTION N.IT�#IM THE 188 DAY PERIOD. FINAL INSPECTION MUS� BE APPROVED BEFORE BUILDING CAN BE OCCUPIED. " - DONE Oti AGENT: , ,, �, `' DATE: BID PONT, rev: 13131191 COMPLIANCE TO ATTACHED CONDITIONS IS REOU 1 RED CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date - 7 - by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date • by date by date by FRAMING Walls FIRE DEPT. date by date,j- co- C>0 by date by PLUMBING Attic OTHER Groundwork date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by Yt c� c � ! -,5��` �� cr�� via .r, ✓ �s c c , -- - �. L)�,L c5y^ /o G -ZZ_ Zoo FitA�i,N� F.4 0 _ � � �_a�Q�ic�c�L UJ y ✓as cam' o' l I L,.J p..1 --- — (� t t12. /moo ��. MASON COUNTY Ma son County Bldg. III 426 W. Cedar RO. Box 186 Shelton, Washington 98584 I` IPE RM 1 -1- 00NO 1 T 1 C)N —'13 Case No . : BLD99-0155 For : TROY THOMAS l Page : 1 1 ) The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marsha L..,. X 2 ) Provisions for surface/subsurface drainage control must be Implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels . Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose . For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PER10I T for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450 . or any construction which is proposed 'to be located within 25 ' of a Mason County read right of way, it is suggested to contact that office to review future planned work which may affect your project . X 3 ) Proposed structure or any portion thereof greater than 30" in height from grade line , must maintain a minimum of 5 ' setback from all property lines , easements and 10 ' from all Count.Ar._.Onc_ State Road right of ways . X 4 ) All upland areas disturbed or newly created by construction activities shall be �-:eecied , vegetat*d_ of~._ given some other equivalent type of protection against erosion . X...__ .-, 5 ) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act , Its rules , and the Mason County Shoreline Master,Program . MASON COUNTY !� f Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 6 ) Owner/ guilder assumes all responsibility If drainfieid area is eanc:umtu,.r!cd . 7 ) All approved plans care requ i red to be on--site for i r,spect i on purposes . I f Inspection is called for and plans are not on site , Approval WILL. NOT be granted . In addition , a Re-- tnspection fee in the amount of $42 .00 per hour (minimum 1 hour ) will be charged and must be collected by this department prier to any further inspections being performed or approval granted . X_ •,. 1 ____ __ �, ___._ 8 ) PURSUANT TO 1994 UNIFORM BUILDING CODE , ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY . MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS . A REINSPECTION FEE , BASED O RATES I N TA 3 O 1 c N E TABLE A F THE 994 UNIFORM BUILDING CODE WILL BE ASSE.,Sf"n IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS . 9 ) The correction list , along with the Energy Compliance Worksheet (when applicable ) is part of -the plants and must remain attached thereto . It is the responsibility of the applicant to make corrections Indicated on the plans from the correction lists . Once the plans are marked APPROVED, they may not be changed or altered without authorization from the Building Official . The permit holder is reponsibie to retain the complete approved set of plans on site for the duration of the project . Failure to comply will result in failure of required building inspections . Every permit shall expire by limitation and become null and void if the building or work authorized by such permits is not commenced within 180 days from the date of issuance, or, if the building or work authorized by such permits is suspended or abA4i4ow*d at any time after the work is commenced for a pp. i od of 180 (lays . X� 10) The approved plot plan' is required to be on-site for inspection purposes . if inspection is called for and plot plan is not on site, Approval WIL..L NOT be grunted . In addition, a Re- Inspection fee In the amount of $42 .00 per hour (minimum i hour ) will be charged and must be collected by this department prior, to any further Inspections being performed or approval granted . MASON COUNTY Mason County Bldg, III 426 W. Cedar P,O, Box 186 Shelton, Washington 98584 11 ) No Occupanc This structure is limited to U-1 use only . Any other uc: vi1'1 b, violation ofy .the Uniform Building Code and Mason--Count, Regu i a t i ons unless a "Change of Use" permit is approved . X \ � 12) ALL CONSTRUCTION MUST MEET OR EXCEED ALL.. LOCAL_ CODES AND UBC REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION . ANY CHANGE OF USE OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION . CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE . x 13 ) Changes -to approved building plans that effect compliance to the 1991 Washington State Energy Code , 1991 Ventilation aid Indoor Air Oualityy Code, the Uniform building Code and/or Mason County Regu4 t!QP j. must be approved by Mason County prior to constructionX r 1 4 ) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS R&Wt-RE-0 -PER MASON COUNTY BUILDING DEPARTMENT AND UN i FORM BUILDING CODE . x Case No . , BLD99-0155 - r- Building Permit # MASON COUNTY - BUILDING 111 426 We CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 CORRECTION NOTICE Job Location 2-3 '3 1 (-V�, %, Lt� Dr E This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found' Item Listed below must be corrected to gain code compliance t, L oLjo— ,,- e—y- r, l G c E'Jc S r L You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department (lXC Date ,-2—3 Inspector -C-� ■ so s NUT rk ,* M « OV T 11411k T A ,� MASON COUNTY PERMIT ASSISTANCE CENTER PLANS SUBMITTAL CHECKLIST Owners name: -rh 01.)17a_,S Date "3-/o- Project: 3 Reviewed by:_j _ Documents: ✓ Accurate site plan attached to each set of plans (setback requirements) Topography attached to each set of plans Energy Code application (fuel type /'pG ) Application complete (Mechanical, plumbing, wood stove, etc) Contractor registration# OR provide written notice "Hiring a Contractor or Remodeler Construction Plans: (3 sets) Plans legible Recognized scale Cross Section Elevation Roof framing Deck framing Foundation plan Floor framing,all levels Floor plan (use of room) DETAIL: (Include wood species and grade, i_e. DF#2, HF#2, PT, etc.) Roof framing detail (species, size, & spacing) Wall framing detail (size, species, & spacing) Bearing wall ht exceeding 10 ft requires engineering Floor beams(size, species, & spacing) Floor joists (size, spacing, species) - , I ' Header and beam (size &species for L` enings over 4 ft.) Foundation (size, steel, anchoring) Concrete walls (Reinforcement detail, >8 ft requires engineering) Non-conforming framing (steel structures, foam core, etc. requires full engineering) Fire separation walls shown on plans Point loads identified, calculations provided if needed. Slab insulation shown Handrails on stairs with more than 3 risers Guardrails on landings greater than 30" above grade Stairs -spiral, winding, etc. (rise, run, landings) Location of furnace identified on plan, where? _ Propane appliances in basement (3" screened floor drain to o/s,2 combustion vents) Fireplace/Stove information shown Window sizes marked Covered porch detail (ICBO detail? Braced wall lines clearly marked on plans Interior braced wall lines required for boxes greater than 34 ft Do plans meet UBC prescriptive braced wall line requirements? UNUSUAL SHAPES: Roof or floor extend more than 6 feet beyond brace wall line or ICBO detail. (2326.5.4.2) Openings greater than 12 feet or 50% of the least floor area. (2326.5.4.4) Braced wall lines do not meet in a perpendicular direction. (2326.5.4.6) Braced wall lines offset the vertical plane from the foundation (202 NTE 48", 2x10 NTE 40", no offset in 2x8 or smaller) (2326.5.4.1) Floor and roof is laterally supported by braced wall lines on all edges (2326.5.4.4) The end of a braced wall panel extends more than 1 ft over an opening in the floor below (BWP may extend over an opening 8 ft or less in width when the header is a 4xl 2 or larger) i Engineered documents (Engineering requiredlincluded? ) II Design criteria-snow load ­2 _, wind 80 mph, exposure C, seismic zone 3 V ,5 Engineered data transferred onto the plans Structural general notes, 2 sets Stamped structural calculations, 2 sets Engineers signature and ex iration date COMMENTS: o FORM MUST BE COMPLETED IN INK PERMIT NO.: BLD 0 PLEASE PRESS HARD MASON COUNTY BUILDING PERMIT APPLICATION ' 426 W.Cedar/P.O.Box 186,Shelton,WA 98684 Shelton 360 427-9670 Belfair 360 275-4467 Elma 360 482-5269 Seattle 206 464-6968 APPLICANT INFORMA ION CONTRACTOR INFORM LION Owner Contractor Name S Mailing�^lA% kr^ ess 7 SE �— Mailin Address t 21- City /� State Zip Code 2 City �r. State tjA Zip Code Phone(245'3 )Iq 36 6 52 ) Other Ph.(a3 )-rs5/3c)P- Ph.(20 ) 735/302,Other Ph.C� Lien/Title Holder oll,.Iwo Contractor Reg. # Ae.e� Address 2 e Expiration 11U lip I SEPTIC/WATER SYSTEM INFORMATION-Connect to New Septic Existing S ptic Connect to Sewer System Name of Sewer System Well Water System Name of I, Water System PARCEL INFORMATION-12 i it Tax Parcel No. 23 3 / 2 / Fire i 9 District 5 Legal Description M r- 1- Site Address(Please include street na e, street number and city) ,.` wiz or-a Directions to siteAJyZQA 0, 41e � RX. T Will timber be cut and sold in parcel preparati n? (Yes/No) Is your property within 200' of the following: Body of Water (Name) Saltwater Lake ✓ River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs TYPE OF JOB New Add Alt Repair Other Use of Building Describe Work -� G� �_ No. of Bedrooms�No. of Bathrooms_I SQUARE FOOTAG -1st Moor :5c;- 2nd Floor S 3rd Floor Loft Basement Deck Other sq. ft. Garage Attached Detached Carport Attached Detached MOBILE HOME INFORMATION-Make Model Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat_ Purchase Price $ Replacement Unit ?(Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. X `- Date 6 X Date /U �r FOR OFFICIAL USE BEYOND T POINT Accepted by Date Submittal Amount Due Receipt No. ............... . DEPARTMENTALREVIEvV AA,PROVED E)EiNIED CON1)IT14N CODE5 Building Department Occ Group Type Constr. l—C79 Planning Department 6 O sir ,� Environmental Health Department Public Works Department I Fire Marshal Valuation $ FEES Building Permit Fee Site Inspection Plan Review Fee UFC Plan Review Fee Plumbing & Base Fee Public Works Review Fee Mechanical & Base Fee Other Wood/Gas/Pellet Stove Fee Other Violation Fee Pre-Paid at Submittal ( ) :::�:<:::.v}:.:..:.::.:�::::•::::::.:::...::.,.:::::.:�:.�:::..:.....................:.:....::,.: TOTAL FEES