Loading...
HomeMy WebLinkAboutBLD2011-00526 Final Furnace - BLD Permit / Conditions - 7/12/2011 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 ir Shelton, WA 98584 f;o RESIDENTIAL BUILDING PERMIT BLD2011-00526 OWNER: DON FALK RECEIVED: 6/27/2011 CONTRACTOR: BRENNAN HEATING &A/C 1.206.248.7900 LICENSE: BRENNHA962DU EXP: 12/29/2011 ISSUED: 6/29/2011 SITE ADDRESS: 2441 E MASON LAKE DR EAST GRAPEVIEW EXPIRES: 12/29/2011 PARCEL NUMBER: 222335200038 LEGAL DESCRIPTION: MADINGS SUNNY SHORE ADD#6 TR 38 SURVEY 30/118 PROJECT DESCRIPTION: DIRECTIONS TO SITE: FURNANCE ST RT 3, L ON MASON LAKE RD, L ON MASON LAKE DR EAST TO SITE ADDRESS ON THE LEFT SIDE General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck: Type of Work: MEC Fire Dist.: 3 No. of Stories: Occ. Load: Building: Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: SEPA?: Model: Width: Ft. Rear: Ft. Slope: Ft. Shoreline Desi Side 1: Ft. g.. Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Oty. Type Oty. Type By Date Amount Receipt Furnace<100K 1 Mechanical Base Fee TW 6/27/2011 $28.50 S12011000, Mechanical Permit Fee TW 6/27/2011 S18.30 S12011000t Total $46.80 BLD2011-00526 Please refer to the following pages for conditions of this permit. Page 1 of 3 CASE NOTES FOR BLD2011-00526 CONDITIONS FOR BLD2011-00526 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X t�_'� 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 3) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM STANDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE. X i .4) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. x A. 5) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X ML44 6) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X `} I+ BLD2011-00526 Please refer to the following pages for conditions of this permit. Page 2 of 3 7) Installation of heating equipment in a single-family residence shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and IMC. Heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. All heating equipment shall meet the requirements of the National Appliance Energy Conservation Act(NAECA) and be so labeled. (WSEC503.4) or in accordance to WSEC Section 1411. Xik This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the app��bo��ve��described property and structure for review and inspection. OWNER OR AGENT: aiU_D_ Imo- T��J DATE: — Z r _2ed BLD2011-00526 Please refer to the following pages for conditions of this permit. Page 3 of 3 r o CONCRETE MECHANICAL MANUFACTURED HOME y o r Date By Footings I Setbacks Gas Piping Ribbons o Interior Date By Interior-Date By Date By rn Exterior Date By Exterior-Date By Set-up Z Point Load I Isolated Footings INSULATION Date By BG f SLAB INSULATION Date By Data By FIRE DEPARTMENT Foundation Wails Floors Date By Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING vault Date By Date By OTHER Groundwork Attic Type_ Date By Date By Date By D.W.v DRYWALL Type- Date By Int Brace Wall Date By Date By CD FINAL INSPECTION w Cl) Water Line Fire Seperation / NC m Date By Date Z By Date By .a � s 72, Pass or Request Inspect. c Type of insp. Fail Date Date Done By Comments N c. N O n O 7 a o' y O V1 (D 3 (D 0 Jun 27 2011 9 : 04AN West Seattle Furnace 206 935-0735 p. 2 PERMIT NO. MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar- P.Q. Box 186, Shelton, WA 98584 Shelton(360) 427-e7tO•Belfair(360)275-4467-Elma(360) 482-5269 n the we vvww.co.mason.wa.us APPLICANTINFORVATIQN CONTRACTOR I ORMATION Owner ((�— Company Named Maili g Addres107,7; Maili Ad r s nO I J \ • - City +{ St to --Zip Code City 'u- t L at& � �Zip Code Q Phon Other Ph Phone C Othe Ph. Lien/Title Holder Contractor Reg. # E mail address E Mail Address Drivers Lic.# DOB Drivers Lic. # DOB SEPTIC INFORMATION -Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No,LZ&Za33 S� 0,00 19 Fire District Legal Description Site Address(Please include street name, street number and city) f Directions to site Is property within 200' of Saltwater Lake River/ Creek Pond Wetland Seasonal Runoff Stream Slopes or Chuffs 151 TYPE OF JOB - New Add Alt Repair Other se of Building Location of Fixtures/Units- 1st Floor 2nd Floor o Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No, of Fixtures Fees Fuel Type:Electric_LPG—Natural Gas—Heat Pump— Toilets Type of Unit -NQ,-ot UnitFees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/PelletStove Dishwasher Ktchen Exhaust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OJYNERMUILDER Aclmowlodges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that 1 am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. It permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained perm on from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information p s accurate and grants em ogees of Mason County access to the above described property and structure for review and inspection. OOF F CQNTIh UATION taF RK IS BY MEANS OF A PROGRESS INSPEGTIqNn-1 Date:—r Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bid Poll Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Ooc Group e Constr. Planning Department Environmental Health Department FEES Plumbing&Base Fee Site Inspection Mechanical &Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee Other Violation Fee TOTAL FEES