Loading...
HomeMy WebLinkAboutBLD2008-00783 Final Detached Garage - BLD Permit / Conditions - 10/24/2008 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 P10 RESIDENTIAL BUILDING PERMIT BLD2008-00783 OWNER: BOYD BAKKEN RECEIVED: 6/26/2008 CONTRACTOR: MACKAY ENTERPRISES 1.360.277.0373 LICENSE: MACKAE*944KZ EXP: 5/12/2010 ISSUED: 7/24/2008 SITE ADDRESS: 655 NE TAHUYA RIVER RD TAHUYA EXPIRES: 1/24/2009 PARCEL NUMBER: 322127500041 LEGAL DESCRIPTION: TR 4-A OF SURVEY 1/138 NW1/4 PROJECT DESCRIPTION: DIRECTIONS TO SITE: New detached Garage St Rt 3 to Belfair, L on St Rt 300/North Shore RD, R on Belfair Tahuya Rd, L on Tahuya River Rd. Follow to site address on the left side. General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: II-B Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck: Type of Work: ACC Fire Dist.: 8 No. of Stories: 1 Occ. Load: Building. Garage-Detached 1,200 Valuation: Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Water Body: None Make: Length. Ft. Front: W 40.0 Ft. Shoreline: Ft. SEPA?: No Model: Width: Ft. Rear: E 50.0 Ft. Slope: Ft. Shoreline Desi 9 Side 1: N 10.0 Ft. Not Applicable Year: Serial No.: Side 2: S 10.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee GMM 6/26/2008 $313.40 B12008000 Planning Review Fee GMM 6/26/2008 $190.00 612008000 EH Plan Review GMM 6/26/2008 $40.00 612008000 Building State Fee RTB 7/2/2008 $4.50 612008000 Building Permit Fee RTB 7/2/2008 $482,15 612008000 Total $1,030.05 BLD2008-00783 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2008-00783 CONDITIONS FOR BLD2008-00783 1) All other necessary permits from Mason County, Washington State and/or Federal Agend that ar required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X 2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State, of Labor and Industries, Contractor Compliance Division. There re potential risks and monetary liabilities to the homeowner for using an unregistered-ontractor. Further information can be obtained at 1- --6 -0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. 3) approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will rTfot be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Depart ent prior to any further inspections being performed or approvals granted. 4) O /Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 5) a plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building �-O icial. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or v of approved documents will result in failure of required building inspections. X 6) is structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use per i#�hall be applied for, reviewed and approved prior to the change. 7) FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. 8) The "approved" site plan is required to be on-site for inspection purposes. If an inspectio i requested and the"approved" site plan is not on site, then ipp v will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and shall be collected by the artment prior to any further inspections being performed or approvals granted. X BLD2008-00783 Please referto the following pages for conditions of this permit. 2 of 5 9) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may so sh to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/c racto i acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 10) Concrete used for basement walls, foun ation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other ;iInteronal rete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). 11) e is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. 12) Building Code. In addition to the inspections required by Chapter 1 of the International Building Code, the owner or the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work under IBC, section 1704. The special inspectors' duties & responsibilities shall be as specified in Chapter 17. Special inspection required for instal ti of A325, A490 high strength bolts, provide letter from Engineer of record at time of inspection approving installation of high strength bolts. X 13) An changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached o. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charg and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 14) construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the Stat of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in r i Jvocation. 15) r sions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is pro a located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affec our proje BLD2008-00783 Please referto the following pages for conditions of this permit. 3 of 5 16) All ages to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County odd'inance lrgulation, must be reviewed and approved by Mason County prior to construction. X 17) CON (T CTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections b the Mason Count Building Department. All construction must be in conformance P P J 1 P Y Y 9 P ith a international codes as amended and adopted by Mason County. Any corre s, changes or alterations required by a Mason County Building ns ec r h I be made prior to requesting additional inspections. P P q 9 P X 18) All pr erty lines shall be clearly identified at the time of foundation inspection. X _::::�_ 19) AI ilding permits shall have a final inspection performed and approved by the Mas ounty Building Department prior to permit expiration. The failure o req st a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with on unty ordinances and building regulations. X 20) rmits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action or a eriod not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hol ented action from being taken. No more than one extension may be granted. X - 21) re e t ated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 22) By inition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure t s tructures meet the setback conditions listed. X 23) O /builder assumes all responsibility if drainfield/reserve area is encumbered. X 24) W r ality is not to be degraded to the detriment of the aquatic environment as a r s of this project. 25) Pr' r t final approval, all upland areas disturbed o wl r d by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 26) Temporary erosion control measures must be implem ed to prevent wat qualit ±radation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X BLD2008-00783 Please refer to the following pages for conditions of this permit. 4 of 5 27) pro d er dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. 28) All e Management Practices must be strictly adhered to throughout the proposed development. X This permit becomes null d void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence o continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is b 4aprs inspection.T nero e ent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the abo a desand stru r for iew a d i s tion.OWNER OR A a DATE: v BLD2008-00783 Please refer to the following pages for conditions of this permit. 5 of 5 o CONCRETE MECHANICAL MANUFACTURED HOME D 0 Date C) Footings Setbackv9 �7�� Gas Piping ey Ribbons m o Interior Date d By Interior-Date By Date By Z co Exterior Date -2 . B Exterior-Date By Set-up _ INSULATION � Point Load!Isolated Footings Date By 0 Date By BG 1 SLAB INSULATION 0 Data By FIRE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS ---- --- FRAMING Wails Date By Date Q-L By%� Data ey PROPANE TANKS PLUMBING Vault Data By Date By OTHER Groundwork Attic Dale By Date By Type: Date By D.W.V DRYWALL Type. Date By Int.Brace Wall DateBy Date By FINAL INSPECTION p w Water Line Fire Separation N Date By Date B y Date la, 'f 8 t3 y O co co Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments 4 � �S�P�.�-.r � g;Zed �•L7� a 0 0 m 0 NF- TA F-, R a L7 y�r A 6A 3 � 4 q 4 0 c N a : Sd+ n t t� co 1" 5LoPE —Dri V ��Lb A //o a PLANNING PLANNING: ALL SETBACKS ARE MEASURED FROM THE FURTHEST PROJECTION OF THE BUILDING APPROVED MASON COUNTY DCD PLANNING SITE PLAN REQUIRED TO BE ON SITE RECEIVED CH NG BJECT TO APPROVAL By _ Dat�'1 p e JUN 2 6 2008 BELFAIR OFFICE Name-a4wcl Parcel# 3XL101 6COy BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14, Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces, structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity, and land disturbing activities associated with structural or impervious redevelopment. 'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater. Open, uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area * All dimensions in feet Buildings X oZ60 X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X X = Length of drive begins at the right of way X = Parking Areas X X = Any paved, gravel or packed area per definition above table X = Patios/Walks X X = Any paved, gravel or packed area per definition above table X = Others X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) f p c7 If the Total Impervious Surfac-,Area is LESS THAN 2000 Square Feet, please red acknowledge and sign below. Based Upon the information you ve provided a Stormwater Site Plan IS NOT requir for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate m ormation may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-described property for review and inspection as may be required. X I ad4alll Owner/Agent/Contractor(circle one)Date: 6/ —01 L ^ 0 8 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. I'a�,ie I of 2 Name Parcel# BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. "Title 14, Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to "Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in.their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or vvill have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: Page 2 of 2 MASON COUNTY PERMIT NO.B0 -GY�?Z BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner wo -V n A. SA )e- I L EA1 Company Name n�N l� y j5 0 T Mailing Address L 52 N E T_AA441YA 9 VK X 1) Mailing Address X O City 7_-Af/VYt4 StateW Zip Code 49 R,9 City 7 A A V YA State Zip Code 9 8588 Phone 2 7 5-• -4 fro S Qther Ph. Phone F4 J- '77 - 0 .3 7u! Other Ph.,-, I'J 1,?-1 Lien/Title Holder eJ Y72 S JJAt4 2 A K 14LI,) Contractor Reg. C K £ �i q4l xp. - ,).o Email addressBA K K&N T,414(,,Y.4 Qt)FI-j L, C onn E Mail Address C r a y 00 W t C Drivers Lic.# CKM&P i4lqbF DOB - - 1 SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existi g Sept Connect to Water System Name of Water System )A' 7 5,e T I L G C Well Sewer System Name of Sewer System PARCEL INFORM ON Digi -Parcel No. ` Fire District Legal Description �- 1 :;Ur- Site f Address (Please include street name, street nu ber and city) Directions to site Will timber be cut and sold in parcel preparation?Ye No Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs /�V Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement ac on?Yes/No TYPE OF JOB - New_ZAdd Alt Repair Ot er 11�/IAF�Y RE DENCE SEASONAL ❑ Use of Building Describe Work R LVI(a C' No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor grd+4Qor Basement Dee Covered Deck Other Sq. ft. Garage\\� Attached he Carport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement older or any other party ih interest regarding this application or the work proposed in the application, I have obtained permission from the o apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided s accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This p mit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFA PROGRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THEAPPLICATION. X /^ Date: 01 C — er/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department ? 01 no Planning Department Environmental Health Department Fire Marshal FEES Building Permit Fee / Site Inslaection Plan Review Fee 1312- EH Review Fee Plumbing & Base Fee Planning Review Fee Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee '�- State Fee Violation Fee - - o r Pre-Paid at Submittal Valuation $ TOTAL FEES