Loading...
HomeMy WebLinkAboutBLD2004-00726 Final Log Home - BLD Permit / Conditions - 8/23/2007 Inspection Line(360)427-7262 • MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, WA 98584 IP RESIDENTIAL BUILDING PERMIT BLD2004-00726 I'I OWNER: LARRY BARBER RECEIVED: 5/14/2004 CONTRACTOR: LICENSE: EXP: ISSUED: 1/20/2005 SITE ADDRESS: 811 NE TAHUYA RIVER RD TAHUYA EXPIRES: 4/6/2007 PARCEL NUMBER: 322127500070 LEGAL DESCRIPTION: TR 7 OF SURVEY 1/138 NW1/4 PROJECT DESCRIPTION: DIRECTIONS TO SITE: LOG HOME N ON HWY 3 TO BELFAIR LEFT ON NE CLIFTON LANE GO 3.3 MOLE TURN INTO N SHORE GO RIGHT ON NE BELFAIR TAHUYA GO 8.6 MILE TURN LEFT ON NE TAHUYA RIVER RD GO ONE MILE ON LEFT General Information Construction &Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: V-N Type of Use: SF Insp.Area: No. of Bathrooms: 3 Occ. Group: R-3 Lot Size: Deck: 96 Type of Work: NEW Fire Dist.: 8 No. of Stories: 2 Occ. Load: Building:2,236 Valuation: Building Height: 30 Occ. Status: Primary Basement:1,583 Cov. Deck 336 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: W 80.0 Ft. Shoreline: Ft. Water Body: Rear: E 430.0 Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: N 110.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: S 50.7 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee NJP 5/14/2004 $1,028.14 S22004000 Kitchen Sink 1 Furnace<100K 1 Planning Review Fee NJP 5/14/2004 $155.00 S22004000 Lavatories 3 Gas Outlets 3 EH Plan Review PSD 5/21/2004 $75.00 612005000 Showers 1 Propane Tank 1 Building State Fee MRG 6/15/2004 $4.50 612005000 Water Closets (Toilets) 3 Ventilation Fan 4 Building Permit Fee MRG 6/15/2004 $1,581.75 B12005000 Water Heaters 1 Propane Stove 1 Public Works Review AT 10/29/200 $39.22 1312005000 Bath Tubs 2 Dryer Vent 1 Plumbing Fee JRN 1/19/2005 $91.o0 612005000 Clothes Washer 1 Plumbing Base Fee JRN 1/19/2005 $20.00 612005000 Mechanical Fee JRN 1/19/2005 $135.30 612005000 Mechanical Base Fee JRN 1/19/2005 $23.50 B12005000 EH Permit Revision CEW 9/13/2006 $35.00 B12006000 ADJUST—Plan Check Fee JRN 10/6/2006 $7.28 612006000 ADJUST--Building Permit Fee JRN 10/6/2006 $11.20 612006000 Total $3,206.89 BLD2004-00726 Please referto the following pages for conditions of this permit. 1 of 5 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 RESIDENTIAL BUILDING PERMIT BLD2004-00726 OWNER: LARRY BARBER RECEIVED: 5/14/2004 CONTRACTOR: LICENSE: EXP: ISSUED: 1/20/2005 SITE ADDRESS: 811 NE TAHUYA RIVER RD TAHUYA EXPIRES: 7/20/2005 PARCEL NUMBER: 322127500070 LEGAL DESCRIPTION: TR 7 OF SURVEY 1/138 NW1/4 811 NE TAHUYA RIVER RD PROJECT DESCRIPTION: DIRECTIONS TO SITE: LOG HOME N ON HWY 3 TO BELFAIR LEFT ON NE CLIFTON LANE GO 3.3 MOLE TURN INTO N SHORE GO RIGHT ON NE BELFAIR TAHUYA GO 8.6 MILE TURN LEFT ON NE TAHUYA RIVER RD GO ONE MILE ON LEFT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: V-N Type of Use: SF Insp. Area: No. of Bathrooms: 3 Occ. Group: R-3 Lot Size: Deck: 96 Type of Work: NEW Fire Dist.: 8 No. of Stories: 2 Occ. Load: Building:2,236 Valuation: Building Height: 30 Occ. Status: Primary Basement:1,583 Cov. Deck 192 Manufactured Home Information Setback Information Shoreline& Planning Information : y Make: Length: Ft. Front: W 80.0 Ft. Shoreline: Ft. Water Body: Model: Width: Ft. 11 Rear: E 0.0 Ft. Slope: Ft. Shoreline Desi Side 1: N 110.0 Ft. 9.: Not Applicable Year: Serial No.: Side 2: S 51.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Dishwasher 1 Exhaust Hood 1 Plan Check Fee NJP 5/14/2004$1,028.14 S22004 Kitchen Sink 1 Furnace<100K 1 Planning Review Fee NJP 5/14/2004 $155.00 S22004 Lavatories 3 Gas Outlets 3 EH Plan Review PSD 5/21/2004 $75.00 B12005 Showers 1 Propane Tank 1 Building State Fee MRG 6/15/2004 $4.50 B12005 Water Closets (Toilets) 3 Ventilation Fan 4 Building Permit Fee MRG 6/15/2004$1,581.75 B12005 Water Heaters 1 Propane Stove 1 Public Works Review AT 10/29/200 $39.22 612005 Bath Tubs 2 Dryer Vent 1 Plumbing Fee JRN 1/19/2005 $91.00 B12005 Clothes Washer 1 Plumbing Base Fee JRN 1/19/2005 $20.00 612005 Mechanical Fee JRN 1/19/2005 $135.30 B12005 Mechanical Base Fee JRN 1/19/2005 $23.50 B12005 Total $3,153.41 BLD2004-00726 Please referto the following pages for conditions of this permit. 1 of 5 CASE NOTES FOR BLD2004-00726 CONDITIONS FOR BLD2004-00726 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0 82. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. XA 2) The Uniform Fire Code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150 from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where sucp roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 3) Temporary erosion control measures must be implemented to prevent water qu;�y degradation of adjacent waters or wetlands. Silt fencing must be installed and maintained until upland vegetation has become established. X 6 4) Appr ed per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X :�� 5) The mpnufac ured home must be removed of the parcel prior to certificate of occupancy, i.e. final approval, of the permit. X 4K 6) All upland areas disturbed or ne iy created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X ': 7) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Depart nt prior to any further inspections being performed or approvals granted. X �VV BLD2004-00726 Please referto the following pages for conditions of this permit. 2 of 5 8) In accordance with the Uniform Building Code and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background. Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted by the jurisdiction and the Uniform Building Code will be assessed if the owner and/or contractor fail to post the address on site prior to requesting inspec4ons. X b^4 9) The plan review check list and corrections, along with the Energy Compliance Worksheet(when applicable) are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans gn site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. d 10) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X TZg 11) The"approved" plot plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved" plot plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building epa ment prior to any further inspections being performed or approvals granted. X , 12) Washington State Energy Code Compliance has been approved using the following: Heat Type: Electric or other fuels Compliance Method: IV Window (Max U-Factor):0.40 Skylight(Max U-Factor):0.58 Doors ype/Max U-Factor):0.40 or less, Wall insulation R-21 , Floor insulation R-30 , Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10 X ., 13) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air from/ uts'de in accordance with the Uniform Mechanical Code. X T� OS T 14) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X Z216 15) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charge0and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. 4yv 16) All construction must meet or exceed all local ordinances and the 1997 Uniform Building Code requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result-0 pefjmit revocation.( BLD2004-00726 Please referto the following pages for conditions of this permit. 3 Of 5 17'% Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project/,- X 18) Placement of structure must comply with standards setforth per 1997 UBC Chapter 18 regarding descending and/or ascending slopes. X 'k 19) All changes to"approved" building plans that effect compliance with the Uniform Codes as amended and adopted, or any other Mason County ordinance Xr regul 'o,must be reviewed and approved by Mason County prior to construction. 20) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of S from any building opening (foundation vents, windows, doors etc), property line or easement. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X y n � 21) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, property line, public way, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. If a propane tank is exposed to probable vehicu�d9nage, protective bollards must be installed. X 15 22) All propane tanks must be installed in accordance with the Uniform Fire Code and all applicable Mason County ordinances. All propane tanks must meet the inst ation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X ,41," 23) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspectionthe test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall Xt se until the final inspection has been performed and approved by a Mason County building inspector. 24) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think suc atur s exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 25) All property lines shall be clearly identified at the time of foundation inspection. X 142 BLD2004-00726 Please referto the following pages for conditions of this permit. 4 of 5 261. All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Maso oy.pty ordinances and building regulations. X OO�� z 27) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder h7 prevented action from being taken. No more than one extension may be granted. X 28) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, con`ecip , d flashing. Install metal connectors approved for contact with the new types of pressure treated material. X �� 29) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and/or land modifications (grading, cuts, fills, etc.) required in the geotechnical reassessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X0�� 30) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, conne J r and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X _ 31) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and/or land modifications (grading, cuts, fills, etc.) required in the geotechnical r$Port/assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X ' � Q This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property structure for review and inspection. i OWNER OR AGENT: L _ ,F'7�' DATE: BLD2004-00726 Please referto the following pages for conditions of this permit. 5 of 5 26) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with X aso � ty ordinances and building regulations. 27) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hold eyyh v� prevented action from being taken. No more than one extension may be granted. 28) Pressure, treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, X nne, �, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. 29) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and /or land modifications (grading, cuts, fills, etc.) required in the geotechnical port assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X ' : 30) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, Xonnn%t rand flashing. Install metal connectors approved for contact with the new types of pressure treated material. 31) The approval of this project is subject to the recommendations and specifications outlined in the attached geotechnical report or assessment. Structures and/or land modifications (grading, cuts, fills, etc.) required in the geotechnical L4port/assessment, may require a seperate permit. The geotechincal report/assessment shall remain attached to the approved building plans. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described propert and structure for review and inspection. OWNER OR AGENT: It t-j— ll/L DATE: OeZ,-?- v2 z', •7��'S BLD2004-00726 Please referto the following pages for conditions of this permit. 5 of 5 I CONCRETE y MECHANICAL MANUFACTURED HONIE Footings/Set acks Date B y Ribbons Date Qq{ JZ By j_� GasPJPing-fv%f, Z11`PY' ter— Date By Foundation Malls Date By Set-up Date Y _ By 77 INSULATION Date By B G / Slab ns lation Floors Final Date QS 13 OS BY Date By Date By FRAMING Walls FIRE DEPT Date-z I7 '�- By t-IIIL. Date//7 () � � 01► &By Date By PLUMB NG Attic OTHER Groundwork Date -i 71 h' Byu> Date ByVALLBOAR WXILING D.W.V. Date Z? Z l lyti Date By LOi-- FINAL NS ECTION Water Line Date . 7 B y Date By Date By `(PE o F E(4uFST Inc rod c A 5 COMtAF:u s l'ZIP RIS cf or— 2 w 5E AEk� ` sus P ' Dr q N p, 8 l 2L NUL�- �6S Z 7 bL Z�Ib v� 1�� 1 �T rt4s �C 7v %'�r+Ci rs Z 16111� -ell7/06 �I J7 S- l.r rf Cyt ne -� wP 3 " ` -7/06 LOL 1 C.) o bW ? t_O REVISION R3W W.M . SECTION 12 SE1 4 OF THE NW 1 4 TRACT 7 RECEIVED IvED NE 811 TAHUYA RIVER RD MAY 1.7 2004 DATE 426 W. CEDAR ST, PLANNING � N88 56 39 E 1103.39' / /Assumed ELE top of Hub 100 \ \ \ 9 o0 Gravel . J I / / ) <� Drl'hue ay` r / ell // \1/ 100'litodius Yanklr< _GwnJ—ie_, ) / / NE River 1 '•� ' J / // / j / 1 1 N .� Rp Power Box TeleRls O00 / N88'56'39 E 1032.02 40.3' Ei It Q ,f5/�/ APPROI✓ Ea � s�rE P ACOU"17-Y DC0 110, 6��, CFIq GES SUa�,E_',`'' TO E3E N ' - /'�� 4J �� E� ECT TO APPROVSIT- Dates A� _ y /Z o6 n A T22N R3W W.M . SECTION 12 SE1 /4 OF THE NW 1 /4 TRACT 7 RECEIVED NE 811 TAHUYA RIVER RD MAY 1.7 2g% 426 W: CEDAR STI PLANNING N88 56 39 E 1103.39' � Ass umed ELE top of Hub 100' 6�0 �41 64 Gravel) °ns ell 7�/ 1W( odiue \ \1 / lank/ / / /NE Tchuya River RD Power BoxLP L /H6rr / / ✓ ! / / Q'o3o of 05 cD'0 4. O N88'56'39 E 1032.02 / 40.3' a� C ^ QC), 5� db �os�/S b� Request To Revise An Approved Plan Permit Number: BJ D200_�/_- Name Parcel Number ��o� _ �S _ Phone Number da ime L 0)271 Project Address ailing Address I . Please provide a complete, detailed desk 'ption o the proposed revisions o t e approved pl r . c s � � - � S Are two sets of the revised plans or addendum indicating the changes included? ❑ Yes ❑ No Are the approved site plans included? ❑ Yes ❑ No Are the revisions clearly and accurately identified on the plans or addendum? ❑ Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes ❑ No If Yes, Has the engineer or architect approved this revision? ❑ Yes ❑ No Is a stamped and signed approval included with this request? ❑ Yes ❑ No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record Does the proposed revision modify the footprint or location of the structure? ❑ Yes ❑ No If Yes, Is a revised site plan,with all new setback dimensions included with this request? ❑ Yes ❑ No Additional Information: Applicant's signature Date: Office Use Only Received by. Date Sent Assigned To Approved By Date /� Original Valuation: $ �} to cP Additional Valuatio�t: $ Sq.Ft —�—�—�x$ ' r >. . $ Sq.Ft. i 1 x$ S H: Total New Valuation $ 39 P.W. I Additional Fees: Additional Planning Dept. $ New Setbacks: Front / Rear / Additional Plan Review $ Additional Building Permit $ 1 1 �? Sidel. / Side2 / Additional Plumbing $ Additional Conditions/Comments: Additional Mechanical $ Additional E.H.Dept. $ Other $ Total Amount Due: $ Amount To Be Paid Up-Front$ r� a�a sRc a7vzoo� oN_srgTF MASON COUNTY o P� 1,11 c o- DEPARTMENT OF COMMUNITY DEVELOPMENT Y s U Planning Division i O T �? P O Box 279, Shelton,WA 98584 N ooJ Y 0 (360)427-9670 1864 NOTIFICATION OF INCOMPLETE APPLICATION June 01, 2004 LARRY BARBER 811 NE TAHUYA RIVER RD TAHUYA WA 98588 Parcel No.: 322127500070 Project Description: LOG HOME Dear Applicant: You have submitted a permit application (case no. BLD2004-00726) for proposed construction or development in the county. Upon review of your application, I have determined that the contents of the application are incomplete or do not provide enough detail for review. Therefore, review of your application will not proceed until the necessary information is provided (see the comment section of this letter for details.) Once the information is submitted and the application is complete, I will continue to process your application accordingly. If the additional information is not provided to the County within 180 days of this request, the application shall expire and no further action on the proposed development shall take place. Please contact me at (360) 427-9670, ext. 577 if you have questions. in re , Rick Mraz Land Use Planner Mason County Planning Depa 6/1/2004 1 of 2 BLD2004-00726 NOTIFICATION OF INCOMPLETE APPLICATION 6/1/2004 Case No.: BLD2004-00726 Comments: A review and field inspection of the subject property indicates that the parcel already contains a residence. The existing home is definable as an Accessory Dwelling Unit (ADU). Keeping the old home will require both a Special Use Permit and a Variance from the Mason County Development Regulations. Per the Section 1.03.029 of the Mason County Development Regulations, ADUs must receive a special use permit and must not exceed 900 square feet or 50% of the habitable area of the primary residence. During the site visit, it was indicated that the existing home is approximately 1344 square feet. Since the proposed new home is approximately 3700 square feet, the old home exceeds the maximum size for an ADU. Therefore, the variance is required. In addition, the parcel is contains a steep slope. A steep slope trends downward away from the building site at an angle in excess of 21.8 degrees. This area meets the criteria for a Landslide Hazard Area per the provisions of the Mason County Resource Ordinance No. 77-93. Any site work or application for development within 300 feet of a Landslide Hazard Area requires geotechnical report to assess slope stability and address specific efforts to remediate the hazard. Enclosed is a copy of the Landslide Hazard Areas chapter of the Resource Ordinance. Please note the distinction between a geologic assessment and a geotechnical report. This project will require a geotechnical report. Actual slope setbacks will be established by the contents of the geotechnical report. A final issue relates to the existence of a Forest Practices Moratorium on the parcel. This 6-year Moratorium prohibits the issuance of any building permit during its life. Planning staff requests any documentation that you may possess that indicates the moratorium has expired. The permit for the new home cannot be processed until the geotech report, FPA information, completed applications for the Special Use Permit and the Variance are received. Both applications, with instructions for their completion, are enclosed for your convenience. If you have questions or require clarification of these issues, please contact me. 6/1/2004 2 of 2 BLD2004-00726 D C G1 I r I N LL-- 160 plf r r N DL= 60 plf v Reaction 1 - 4x10 DOUG-F'IR/LARCH #2 3 Reaction LL =1060. lbs LL =1060. lbs x DL =397.5 lbs DL =397.5 lbs m TL =1457.5 lbsN 131-03" TL =1457.5 lb Q Q W Min Bearing =1.5 in Min Bearing =1.5 in d to m 3 Based on top edge having continuous lateral support. DEFLECTION Used repetitive member bending allowable. L/180 = .8833 inches Increase in allowable for duration of load = 0 % L/240 = .6625 inches L/360 = .4417 inches BENDING = 93.5% of the allowed SHEAR - No increase L/480 = .3313 inches ALLOWED = 61990. inch/lbs ALLOWED = 2050.4 pounds TL Deflection = .4131" - L/385 ACTUAL = 57935.6 inch/lbs ACTUAL = 1287.9 pounds LL Deflection - .3004- - L/529 OD m Bending OK Shear OK Deflection OK (floor or roof) m A r D Plan Analyst Software Tom Herstad Building Design, Inc BARBER FLR BEAMS by Ben Weese and Assoc. 296 Tremont St. www.plananalyst.com Port Orchard, WA 98366 360-876-6893/360-876-7419 m r I� N m a LL= 40 plf DL= 30 plf 4x10 DOUG-FIR/LARCH #2 a Reaction Reaction LL =350. lbs LL =35Q. lbs DL =262.5 lbs DL =262.5 lbs 17*-0b+1 TL =612.5 lbs w TL =612.5 lbs Min Bearing =1.5 in Min Bearing =1.5 in c a Based on top edge having continuous lateral support. DEFLECTION Used repetitive member bending allowable . L/180 ! 1.1667 inches Increase in allowable for duration of load = 0 % L/240 .875 inches as L/360 = .5833 inches a BENDING = 51.9% of the allowed SHEAR - No increase L/480 = .4375 inches N ALLOWED = 61990. inch/lbs ALLOWED = 2050.4 pounds TL Deflection = .3999" - L/525 '" ACTUAL = 32156.3 inch/lbs ACTUAL = 558.5 pounds LL Deflection = _2285" - L/919 x Bending OK Shear OK Deflection OK (floor or roof) E a m m m Plan Analyst Software Tom Herstad Building Design, Inc BARBER BERMS @ 24" m by Ben Weese and Assoc. 296 Tremont St. www.plananalyst.com Port Orchard, WA 98366 °' 360-876-6893/360-876-7419 i u a LL= 300 plf DL= 144 plf Reaction 2 - 2x12 DOUG-FIR/LARCH #2 Reaction LL =2100 . lbs LL =2100 . lbs DL =1008 . lbs 14 ' -00" DL =1008 . lbs TL =3108 . lbs TL =3108 . lbs Min Bearing =1 . 7 in Min Bearing =1 . 7 in Based on top edge having continuous lateral support . DEFLECTION Increase in allowable for duration of load = 15 o L/180 = . 9333 inches L/240 = . 7 inches L/360 = . 4667 inches BENDING = 199 . 3% of the allowed SHEAR - No increase L/480 = . 35 inches ALLOWED = 65496 . 1 inch/lbs ALLOWED = 2458 . 1 pounds TL Deflection = . 6738" - L/249 ACTUAL = 130536 . inch/lbs ACTUAL = 2691 . 8 pounds LL Deflection = . 4553" - L/369 MEMBER OVER STRESSED SHEAR ALLOWABLE EXCEEDED Deflection OK (floor or roof) Plan Analyst Software Tom Herstad Building Design, Inc RIDGE BEAM by Ben Weese and Assoc. 296 Tremont St . www.plananalyst . com Port Orchard, WA 98366 360-876-6893/360-876-7419 ONE PIECE PR TR bxb 4x5 HUNG TO PO5T5 2x8 J5T5 POUR NEW GONG AROUND POST (4) #4 BAR AROUND PIN BEAM IN/ (2) #4 BAR PIN NEW TO EX. IN/ (4) lip il— #4 BAR d MASTIC EX15TG 24" 5r3+ RED+s .at n 900Z ZO :VZ :bi 82 daS nUl t joMAS A,HER5TAt4 $TPTEOF WA�i'.iN�iO"' �J AA/�.HE�tSTA� S=ATOM r Vil c NING�CN — b O F NGH DR _ 24"x24"xl2" I �-- — xl G B F=240 _ bxb POST5 FOOTIN65 II 1 I I I m I I O 2"xb" 1015T5 m ryX ® I6' Oz. LL I # I1� 12"xl2"x5" 0 FOOTINGS 4x4 P05 5 i I I �r I 1 I I I I I I I I I 1 I I LL= 150 plf DL= 90 plf 1 - 4x12 DOUG-FIR/LARCH #2 Reaction Reaction LL =1050 . lbs LL =1050 . lbs DL =630 . lbs DL =630 . lbs TL =1680 . lbs 14 ' -00" TL =1680 . lbs Min Bearing =1 . 5 in Min Bearing =1 . 5 in Based on top edge having continuous lateral support . DEFLECTION Increase in allowable for duration of load = 15 % L/180 = . 9333 inches L/240 = . 7 inches L/360 = . 4667 inches BENDING = 83 . 9% of the allowed SHEAR - No increase L/480 = . 35 inches ALLOWED = 84053 . 3 inch/lbs ALLOWED = 2867 . 8 pounds TL Deflection = . 3122" - L/538 ACTUAL = 70560 . inch/lbs ACTUAL = 1455. pounds LL Deflection = . 1951" - L/861 Bending OK Shear OK Deflection OK (floor or roof) Plan Analyst Software Tom Herstad Building Design, Inc END ROOF BEAM by Ben Weese and Assoc. 296 Tremont St. www.plananalyst .com Port Orchard, WA 98366 360-876-6893/360-876-7419 LL= 280 plf DL= 105 plf Reaction 1 - 4x6 DOUG-FIR/LARCH #2 Reaction LL =560 . lbs LL =560 . lbs DL =210 . lbs DL =210 . lbs TL =770 . lbs 4 ' -00" TL =770 . lbs Min Bearing =1 . 5 in Min Bearing =1 . 5 in Based on top edge having continuous lateral support . DEFLECTION Increase in allowable for duration of load = 0 o L/180 = . 2667 inches L/240 = . 2 inches L/360 = . 1333 inches BENDING = 44 . 80 of the allowed SHEAR - No increase L/480 = . 1 inches ALLOWED = 20645. 6 inch/lbs ALLOWED = 1219 . 2 pounds TL Deflection = . 0286" - L/1681 ACTUAL = 9240 . inch/lbs ACTUAL = 593 . 5 pounds LL Deflection = . 0208" - L/2311 Bending OK Shear OK Deflection OK (floor or roof) Plan Analyst Software Tom Herstad Building Design, Inc mid deck beam by Ben Weese and Assoc. 296 Tremont St. Sys www.plananalyst .com Port Orchard, WA 98366 IsARCHiTEC7 ARGHITEC7 360-876-6893/360-876-7419 TDJ.�OMAS'A.'.�ERS, G Iif(`-r, LL= 140 plf DL= 52 . 5 plf Reaction 1 - 4x8 DOUG-FIR/LARCH #2 Reaction LL =420 . lbs LL =420 . lbs DL =157 . 5 lbs 6' -00" DL =157 . 5 lbs TL =577 . 5 lbs TL =577 . 5 lbs Min Bearing =1 . 5 in Min Bearing =1 . 5 in Based on top edge having continuous lateral support . DEFLECTION Increase in allowable for duration of load = 0 o L/180 = . 4 inches L/240 = . 3 inches L/360 = . 2 inches BENDING = 29 . 6 of the allowed SHEAR - No increase L/480 = . 15 inches ALLOWED = 35873 . 9 inch/lbs ALLOWED = 1607 . 1 pounds TL Deflection = . 0316" - L/2281 ACTUAL = 10395. inch/lbs ACTUAL = 461 .2 pounds LL Deflection = . 023" - L/3136 Bending OK Shear OK Deflection OK ( floor or roof) m H r Building Desi n Inc end deck beam Plan Analyst Software To e stad g , by Ben Weese and Assoc. 296 Tremont St . 5794 tSTEctE� www.plananalyst .com Port Orchard, WA 98366R;.+ TEci 360-876-6893/360-876-7419 TMQMAS A•}iERSTA , STATE� F�:AStttN:��CJ' J N.L.01son&Associatesinc, Engineering, Planning and Land Surveying. October 4, 2006 Larry Barber 811 NE Tahuya River Road Tahuya, WA 98588 RE: Deck modifications, County Building permit#2004-00726 Dear Mr. Barber, I am writing in reference to the modifications of your deck from the approved building plans. The deck was built with a 14-foot span for the ridge beam. A Mason County building inspector indicated that engineering was required to ensure the safety of the deck. Tom Herstad Building design is the architect for the building, and he has provided a set of calculations for the End roof beam, the mid-deck beam,the end deck beam, and provided a detail of the 24"by 24"by 24" footing. I have reviewed the beam calculations and I concur with the architect's calculations. The ridge beam is a double 2x12 DF#2 and undersized for the application. I recommend that a 3-1/2"by 9-1/2" Parallam 2.0E be placed under the existing ridge beam. The Parallam shall be connected to the posts on each end with a Simpson HUCQ410-SDS hanger. Supporting calculations are enclosed. Please forward this information to the County building department. If you or the plans examiners have any questions,please don't hesitate to contact me. Sincerely, Matthew Z locki, PE f! N.L. Olson & Associates, Inc W TO �p e �sSja-NAL���'ti EXPIRES -7 t 2453 BETHEL AVENUE, P.O. BOX 637, PORT ORCHARD,WASHINGTON 98366 (360) 876-2284 FAX (360) 876-1487 NIL Olson &Associates, Inc Title: Barber Deck Job# 2453 Bethel Ave Dsgnr: MMZ Date: 2:04PM, 4 OCT 06 Port Orchard,WA 98366 Description:Analysis of Ridge Beam (360)876-2284 Scope : 580004UseKW-0602029,Ver580,1-Dec-2003 General Timber Beam Page 1FR-ev,, c)1983-2003 ENERCALC Engineering Software barber deck.euw,Calculatic Description As-Built Deck Ridge Beam I General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC,2003 NFPA 5000. Base allowables are user defined , Section Name 2-2x12 Center Span 13.50 ft . . . . .Lu 0.00 ft Beam Width 3.000 in Left Cantilever 2.00ft . . . . .Lu 0.00 ft Beam Depth 11.250 in Right Cantilever ft . . . . .Lu 0.00 ft Member Type Sawn Douglas Fir-Larch,No.2 Bm Wt.Added to Loads Fb Base Allow 900.0 psi Load Dur.Factor 1.150 Fv Allow 180.0 psi Beam End Fixity Pin-Pin Fc Allow 625.0 psi Wood Density 30.000 pcf E 1,600.0 ksi Full Length Uniform Loads Center DL 144.00#/ft LL 300.00 #/ft Left Cantilever DL 144.00#/ft LL 300.00 #/ft Right Cantilever DL #/ft LL #/ft Summary � Overstressed in Bending ! Span=13.50ft,Left Cant=2.00ft,Beam Width=3.000in x Depth=11.25in, Ends are Pin-Pin Max Stress Ratio 1.855 : 1 Maximum Moment 10.1 k-ft Maximum Shear* 1.5 4.0 k Allowable 5.5 k-ft Allowable 7.0 k Max.Positive Moment 10.12 k-ft at 6.812 ft Shear: @ Left 3.11 k Max.Negative Moment -0.30 k-ft at 0.000 ft @ Right 3.02 k Max @ Left Support -0.90 k-ft Camber: @ Left 0.123 in Max @ Right Support 0.00 k-ft @ Center 0.282 in Max.M allow 5.46 Reactions... @ Right 0.000 in fb 1,919.91 psi fv 119.66 psi Left DL 1.34 k Max 4.01 k Fb 1,035.00 psi Fv 207.00 psi Right DL 1.00 k Max 3.02 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.188 in -0.581 in Deflection 0.082 in 0.262 in ...Location 6.812 ft 6.750 ft ...Length/Deft 583.2 183.3 ...Length/Deft 862.8 278.65 Right Cantilever... Camber(using 1.5"D.L.Defl)... Deflection 0.000 in 0.000 in @ Center 0.282 in ...Length/Deft 0.0 0.0 @ Left 0.123 in @ Right 0.000 in Stress Ca cl s Bending Analysis Ck 31.887 Le 0.000 ft Sxx 63.281 in3 Area 33.750 in2 Cf 1.000 Rb 0.000 CI 4013.341 Max Moment Sxx Reg'd Allowable fb @ Center 10.12 k-ft 117.39 in3 1,035.00 psi @ Left Support 0.90 k-ft 10.46 in3 1,035.00 psi @ Right Support 0.00 k-ft 0.00 in3 1,035.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 4.04 k 3.90 k Area Required 19.510 in2 18.863 in2 Fv:Allowable 207.00 psi 207.00 psi Bearing @ Supports Max.Left Reaction 4.01 k Bearing Length Req'd 2.140 in Max.Right Reaction 3.02 k Bearing Length Req'd 1.612 in NL Olson&Associates, Inc Title: Barber Deck .lob# 2453 Bethel Ave Dsgnr: MMZ Date: 2.04PM, 4 OCT 06 Port Orchard,WA 98366 Description :Analysis of Ridge Beam (360)876-2284 Scope: Rev: 580004 User:l(w-0602029.ver5.80,1-Dec-2003 General Timber Beam Page 1 (c)1983-2003 ENERCALC Engineering Software barber deck ecw:Calculati;J Description Deck Ridge Beam repair General Information Code Ref: 1997/2001 NDS,2000/2003 IBC,2003 NFPA 5000, Base allowables are user defined ' Section Name Prllm:3.5x9.5 Center Span 13.50 ft . . . ..Lu 0.00 ft Beam Width 3.500 in Left Cantilever ft . . . . .Lu 0.00 ft Beam Depth 9.500 in Right Cantilever ft . . . . .Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist-MacMillan,Parallam 2.0E Bm Wt.Added to Loads Fb Base Allow 2,900.0 psi Load Dur.Factor 1.150 Fv Allow 290.0 psi Beam End Fixity Pin-Pin Fc Allow 650.0 psi Wood Density 30.000pcf E 2,000.0ksi Full Length Uniform Loads Center DL 144.00#/ft LL 300.00 #/ft Left Cantilever DL 144.00#/ft LL 300.00 #/ft Right Cantilever DL #/ft LL #/ft Summary Beam Design OK Span=13.50ft, Beam Width=3.500in x Depth=9.5in,Ends are Pin-Pin Max Stress Ratio 0.702 : 1 Maximum Moment 10.3 k-ft Maximum Shear* 1.5 4.1 k Allowable 14.6 k-ft Allowable 11.1 k Max. Positive Moment 10.27 k-ft at 6.750 ft Shear: @ Left 3.04 k Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 3.04 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000 in Max @ Right Support 0.00 k-ft @ Center 0.338in Max. M allow 14.63 Reactions... @ Right 0.000in fb 2,341.54 psi fit 121.93 psi Left DL 1.02 k Max 3.04 k Fb 3,335.00 psi Fv 333.50 psi Right DL 1.02 k Max 3.04 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.226 in -0.674 in Deflection 0.000 in 0.000 in ...Location 6.750 ft 6.750 ft ...Length/Deft 0.0 0.0 ...Length/Deft 718.3 240.43 Right Cantilever... Camber(using 1.5 D.L.Defl)... Deflection 0.000 in 0.000 in @ Center 0.338 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 19.860 Le 0.000 ft Sxx 52.646 in3 Area 33.250 in2 Cf 1.000 Rb 0,000 CI 3043.757 Max Moment Sxx Reg'd Allowable fb @ Center 10.27 k-ft 36.96 in3 3,335.00 psi @ Left Support 0.00 k-ft 0.00 in3 3,335.00 psi @ Right Support 0.00 k-ft 0.00 in3 3,335.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 4.05 k 4.05 k Area Required 12.157 in2 12,157 in2 Fv:Allowable 333.50 psi 333.50 psi Bearing @ Supports Max. Left Reaction 3.04 k Bearing Length Req'd 1.338 in Max. Right Reaction 3.04 k Bearing Length Req'd 1.338 in Engineered Wood&Structural Composite Lumber Connectors FACE MOUNT HANGERS U/HU /-Joist&Structural Composite Lumber Hangers See Hanger tables on pages 92 to 96.See Hanger Options on page 188 for hanger modifications,which may result in reduced loads. U—The standard U hanger provides flexibility of joist !4 to header installation.Versatile fastener selection with tested IIII allowable loads. HU410 HU—Most models have triangle and round holes.To achieve Typical HU7 maximum loads,fill both round and triangle holes with common Installation � nails.These heavy-duty connectors are designed for schools and ; other structures requiring additional strength,longevity and �'•safety factors. factors. '$. MATERIAL:See tables on pages 92 to 96. a FINISH Galvanized o INSTALLATION: •Use all specified fasteners.See General Notes. c •HU--can be installed filling round holes only,or qo filling round and triangle holes for maximum values. a �, •Web Stiffeners are required for all I-joists I used with these hangers. !' OPTIONS:•HU hangers available with the header Model configurations HUC412 )/' Typical HU7 flanges turned in for 25/ie and larger widths, may differ from those Concealed a` �•; Installation ds g 9 Y with no load reduction—order HUG hanger. shown.Some HU Flanges •See Hanger Options on page 188 and 191, models do not have g K for sloped and/or skewed U/HU models,and triangle holes.Consult / y HUG(concealed flange)models. factory for details. •See also HUS series. t e FACE MOUNT HANGERS Cb HUCQ/HUS/HHUS/HGUSDouh1e Shear SCL Hangers n See Hanger tables on pages 92 to 96.See Hanger Options on page c 188 for hanger modifications,which may result in reduced loads. _ cCa These hangers have the highest loads of any face mount hangers! All hangers in this series have double shear nailing,except the HUCQ. This patented innovation distributes the load through two points on each joist nail for greater strength.It also allows the use of fewer nails,faster installation, and the use of common nails for all connections.(Do not bend or remove tabs) MATERIAL:See tables,pages 92 to 96. ° " • FINISH:Galvanized.Some products available in stainless steel or Z-MAX; see Corrosion-Resistance,page 6-7. INSTALLATION •Use all specified fasteners.See General Notes. e s •Do not use double shear hangers with I-joists. •Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. •Not designed for welded or nailer applications. •16d sinkers(0.140"dia.x 31 long)may be used where HHUS410 HUGO HUSC 10d commons are specified with no reduction in load.Where Concealed Flanges Z 16d commons are specified,10d commons or 16d sinkers (not available for HHUS, (0.148"dia.x 3';4"long)may be used at 0.85 of the table load. ° — 25ie--. HGUS and HUS1.81/10) •With 3x carrying members,use 16dx2'h•nails into the header and ° 16d commons into the joist with no load reduction.With 2x carrying 6 members,use 10dxl'N nails into the header and 10d commons A ° • into the joist,and reduce the load to 0.64 of the table value. •Install HUCO's with SIDS wood screws which are supplied with the hanger. N OPTIONS:•HUS hangers available with the header flanges turned in for ° 31h•wide joist only,with no load reduction.See HUSC Concealed r. - Flange illustration. /: 9 •Concealed flanges are not available for HGUS,HUS1.81/10 and HHUS. „ •See Hanger Options,page 188,for sloped and/or skewed HHUS o and HGUS models. ° •Other sizes available;consult your Simpson representative. HGUS46 �; S' U ___ Dimensions Fasteners Allowable Loads(DF-LVL) 2 f Model No. W H B Face Joist ''n Floor Snow I Rool Rele HUS410 1'�'kr's (133/160) (100) (115) (125) 4ke HUC01.81/9-SDS 113,G 9 3 8-SDS'/4x13/4 4-SDS'/4xl3/4 1505 2360 2715 2950 HUC01.81/11-SDS 113/,o ll 3 10-SDS'/4x13/4 4-SDS'/.x11'4 1505 2950 3395 3510 HUC0410-SDS 39/i° 9 3 12-SDS'/4x2'/s 6-SDS'hx2'k 3025 4955 4955 4955 160 HUC0412-SOS 30/je j11 3 1 14-SDS'/4x2'/s 6-SDS'/4x2'.4 3025 5560 5560 5560 ' o �' Typical HUCQ HUC0610-SOS 5'h 9 3 12-SDS''/.x2'h 6-SDS'/4x2'fx 3025 4955 4955 4955 ' `�1 0 ' Installed on -------__ --- --- _ ...-----...----_.._ ....-------_._.. ._....--- .._..__.. ._...----- a Beam HUC0612-SDS 5'h 11 3 14-SDS'/4x2'h 6 SDS'/.x2'h 3025 5560 5560 5560 1.Uplift loads have been increased for earthquake or wind loading,with no further increase allowed. 2.Download columns apply to either Douglas Fir-Larch/Southern Pine carrying members,or structural composite lumber carrying members that have fastener holding capacity of Douglas Fir. 3.When using structural composite lumber columns,screws must be applied to the wide face of the column, 91 MASON COUNTY PERMIT NO. BUILDING PERMIT APPLICATION3�-D-2 426 W. Cedar • P.O. Box 186, Shelton, WA 98584 0D /�] 4o Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the Web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner — ,ql?R y 9`'7'✓ iv;7,4 A"491FAll Contractor Name Mailing Address // .N F r4WkIVA 19.,yeR R.D Mailing Ad6ess A rr� City '7—/9//vYe9 State(dZAZip Code f$S8� City ate Zip Code Phone (360 )d77-07880ther Ph. ( ) Phon Other Ph. ( ) Lien /Title Holder Ccntr for g. # Exp. Email Address Email Address SEPTIC /WATER SYSTEM INFORMATION -Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System Well ,/ Water System Name of Water System PARCEL INFORMATION - 12 digit Tax Parcel No. 3 /a /�.�/ DDO 70 Fire District Legal Description 7-R 7 nF St..,,f y p y /l3 8 IV w i1�t Site Address (Please include street name, street number and city) _ail WE TAku kA xyeR RA 7xyil eft Directions to site N.AN NKIY 31b BELFA if,K.0/.SFf'ya/A/E&IFMAI`wbo W73 Al Sg69C+Ot. ,uE BEI rAj K T4AM le D gVe R.to MI . N Lof oil Ag T "&MEX Q At 1201 C2AL LELT Will timber be cut and sold in parcel preparation? ( es/No)T n I Is property located within 200' of saltwater N49 Lake)_ RiveRiver/Creek A10 Pond AID Wetland Seasonal Runoff A10 Stream IVO Slopes or Bluffs NV PERMANENT RESIDENCE ❑ SEASONAL RESIDENCE ❑ TYPE OF JOB - New Add Alt Repair Other Use of Building RiFSjbFNGF Is this permit submittal the result of a Stop Work Notice, Correction Notice or other enforcement action?(Yes/No) JVV Describe Work No. of Bedrooms _ No. of Bathrooms SQUARE FOOTAGE - 1st Floor /5'8 3 2nd Floor 3rd Floor N#4 _ Loft IVA Basement 1583 Deck Other A64 sq. ft. 114 Garage /VA Attached A! Detached Al A Carport--&A--Attached —A/,4 Detached /V A MANUFACTURED HOME INFORMATION - Make Model Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? (Yes/No) Installer Name Certification No. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. THE OWNER OR AGENT ON OWNER'S BEHALF, REPRESENTS THAT THE INFORMATION PROVIDED IS ACCURATE AND GRANTS EMPLOYEES OF Mason COUNTY ACCESS TO THE ABOVE DESCRIBED PROPERTY AND STRUCTURES FOR REVIEW AND INSPECTION OF THIS PROJECT. OWNER/BUILDER ACKNOWLEDGES SUBMISSION OF INACCURATE INFORMATION MAY RESULT IN A STOP WORK ORDER OR PERMIT REVOCATION. ACKNOWLEDGEMENT OF SUCH IS BY SIGNATURE BELOW: OWNER AFFIDAVIT- I certify that I am exempt from the require- CONTRACTOR'S AFFIDAVIT - I certify that I am currently regis- ment of the Contractor Registration Law RCW 18.27 and am aware tered as a contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and of the ordinance requirements regulating the work for which this that all work will be done in conformance therewith. No changes permit is issued and all work shall be done in conformance there- shall be made without first obtaining approval. with. No changes shall be made without rst obtaining approval. X Atit,Q• Date :!'/y--700yX [a FOR OFFICIAL USE BEYOND THIS POINT 4?6 )4 . Accepted by Planning Pd Ck# 14! C 4 Date Bld Pd. Reciept No. ST,� DEPARTMENTAL REVIEW APPROVED DENIED CONDITION CODES Building Department I f OS Occ Group Type Constr. Planning Department Environmental Health Department Public Works Department Fire Marshal Valuation $ FEES Building Permit Fee 7S Site Inspection Plan Review Fee ` iy EH Review Fee Plumbing& Base Fee Planning Review Fee Mechanical&Base Fee Other Wood/Gas/Pellet Stove Fee State Fee �0 Violation Fee Pre-Paid at Submittal ( ) TOTALFEES PPPPP MASON COUNTY PERMIT NO.: PLUMBING/MECHANICAL PERMIT APPLICATION 426 W.Cedar/P.O.Box 186 Shelton,WA 98584 Shelton(360)427-9670 Belfair(360)'75-4467 Elma(360)482-5269 APPLICANT INFORMATION CONTRACTOR INFORMATION Owner 4 odg/1 Z,,jnj;r ,4,eA?Z,O_ Contractor Name Mailing Address Mailing Address city_ra"- y-oa State , Zip Code �c q S- City `J State Zip Code Phone L.n ) 2:2,7_n7ttfcOther Ph.( Ph. , _Other Ph.(� Lien/Title Holder e,44-60 ,•..4T-pq. na.,r41, Contractor Reg. # Address Expiration 1 / SEPTIC INFORMATION-Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION - 12 digit Tax Parcel No. 1,2 J /' / ;Zs- / 0,0D ZC2 Fire District Legal Description - nras 6,OQ�G,r�/IF - g �/4,1 44 Site Address (Please include street name,street numb r nd city) SW /ILt Directions to site Is your roe within 200'of the following: Body of Water Name Saltwater ti Q Y property rtY 9� Y (Name) ,d� Lake Al(' River/Creek Aln Pond V D Wetland Ai LJ Seasonal Runoff -q,/c>Stream A/ C7 Slopes or Bluffs TYPE OF JOB New Add Alt Repair Other Use of Building c Location of Fixtures/Units 1 st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Fuel Type: Electric Type of Fixture No.of Fixtures Fees LPG X _ Natural Gas Heatpump Toilets y Tempe of Unit No. of Units Fees Bathroom Sink R Furnace Bath Tubs g Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent / Other Other_ Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTURE/UNIT. NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structures for review and inspection of this project. Acknowledgment of such is by signature below: '- v OWNER AFFIDAVIT-I certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-I certify that I am currently registered as a Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance requirements for which this permit is issued and that all work will be done in requirements regulating the work for which this permit is issued and all work conformance therewith. No changes shall be made without first obtaining shall be done in conformance therewith. No changes shall be made without approval. first obtaining approval. X Date t73 i y 2 0 0 X Date FOR OFFICIAL USE BEYOND THIS POINT Accepted by Date Submittal Amount Due Receipt No. DEPARTMENTAL REVIEW >APPR01tED: GENIE[}.. GQN[!t#IOTVCQQES Building Department Occ Group Type Constr. Planning Department Other Other FEES reit Fee Site Inspection Review Fee UFC Plan Review Fee bing&Base Fee Other anical& Base Fee Other Wood/Gas/Pellet Stove Fee Pre-Paid at Submittal ( ) Violation Fee TOTAL FEES �I