Site Inspection
October 01, 2015
GRANT CALLIN
21631 NE 24TH ST
SAMMAMISH WA 98074
Case No.: SP12015-00057
Parcel No.: 322075000923
Project Description: TO DETERMINE AN ENVELOPE FOR POSSIBLE
CONSTRUCTION OF RESIDENCE, CONSIDERING SLOPE
AND SHORELINE OFFSETS.
Dear Applicant:
Pursuant to your application, a site pre-inspection (SPI) was performed on your property. Below
you will find comments made regarding the proposed development and its critical values.
In some cases, setbacks for development from shorelines, steep slopes, streams, and wetlands
must be included in your specific proposal; these setbacks are included as part of the comments
listed below.
This information is based on County and State regulations as they exist to date. These
regulations may change and may affect the requirements for development of the subject property.
Please contact me at (360) 427-9670, ext. 365 if you have questions.
Sincerely,
lecwv_(b�
Allan Borden
Land Use Planner
Mason County Planning Department
10/1/2015 Page 1 of 5 SP12015-00057
Site Inspection
10/1/2015 Case No.: SP12015-00057
Comments:
Inspection for the Grant Callin on July 14, 2015:
Lot Description: The property [Parcel Number 32207-50-00923
and Parcel 32207-50-00951] is along North Shore Rd. on the
Hood Canal shoreline and is 100 feet wide by 585 [S side] to 594
[N side] P feet deep east of the road [county road and slope on the
east side]. The property has an access easement through the
properties, as reported by the applicant. Observed was a 55
percent and greater slope generally east of the easement; and
low slope and existing native vegetation and an undisturbed upper
beach area on the west side. The applicant wishes to build small
residence and parking area and septic area on the west side, if
they meets the needed special studies and appropriate setbacks.
These findings state regulations in effect at the time of inspection,
unless noted otherwise.
Development Regulations standards:
The site is in Rural Residential 5 zone. Standard building
setbacks are 25-foot front yard setback, and 20-foot side property
line and rear yard setbacks. These setbacks are measured from
structures above grade such as roof overhangs, stairs, balconies,
decks, heat pumps, storage buildings, and fuel tanks.
_Y_ An exception is made for lots less than 100 feet in width,
where side yard setbacks are equal to 10 percent of the lot width,
but no less than 5 feet; for this property that side yard setback is
10 feet.
_Y_ An administrative variance may be requested, to reduce
these setback distances from property lines, to as low as 5 feet or
10 feet (front yard), if the size, shape, or features of the property
constrain development from the proper setbacks. This process
requires application and review at the time of the building permit
submittal.
Resource Ordinance Standards:
_N_ Wetland critical area: Planning staff confirmed that the
parcel does not contain certain wetlands, which are regulated
under Mason County's Wetlands chapter 17.01.070 of the Mason
County Resource Ordinance. The applicant will not need a
wetlands special report during development review.
_N_ Stream setbacks: Stream critical areas (recognized by
10/1/2015 Page 2 of 5 SP12015-00057
Site Inspection
10/1/2015 Case No.: SP12015-00057
state, county, or tribal agencies) were not observed during the
inspection. The development setbacks from these features would
not apply to a proposed improvement on the subject parcel.
_Y_ Slope or Landslide hazards: Slopes greater than 15 percent
adjacent to or within 300 feet of a proposed project were
observed. The applicant shall have a qualified geologist or
engineering geologist visit the subject parcels and prepare a site
analysis to determine whether a geologic special report is needed
during development review.
_Y_ Slope or Landslide hazards: If the geologist confirms the
need for a special report when slopes are over 40 percent, a
Geotechnical Report would be needed to address slope stability,
site conditions, and the other requirements of the enclosed
landslide hazard chapter 17.01.100 section E. 5. as required by
the Mason County Resource Ordinance. The report must include
all Resource Ordinance requirements and a submittal checklist
noting where these requirements are found in the study
document.
_Y_ Slope or Landslide hazards: The prepared special report
shall be specific to proposed site development on the subject
parcel by addressing stabilization of the site (especially the slope
from the road above), and the proposed clearing, grading,
driveway and building location, retaining walls, and stormwater
control. This special report would be submitted and evaluated at
the time of building permit submittal. The study shall address the
presence of the proposed or existing septic system on site
stability conditions and proposed stabilization and construction.
Resource Ordinance - Shoreline setbacks: The shoreline
designation for the area is Rural Environment per the Mason
County Shoreline Master Program, and setbacks would be
determined by the Mason County Resource Ordinance. The
shoreline setback is typically determined by measuring the
average distance from the saltwater ordinary high water mark
(OHWM) to the roofline of adjacent neighboring residences to the
east and west of the subject property, measuring the roof
projection closest to the shoreline. Any portion of the new
structure, including decks, balconies, and rooflines, must be
behind this common line. Landward of this line for 15 feet toward
the shoreline is an area that may be used for lawns, patios or
landscaping (development at grade level). From that point toward
the shoreline is considered to be a required vegetated buffer and
is regulated by the Mason County Resource Ordinance Fish and
10/1/2015 Page 3 of 5 SP12015-00057
Site Inspection
10/1/2015 Case No.: SP12015-00057
Wildlife Habitat Conservation Areas Chapter. Within this chapter
are those activities listed that can be done both with and without a
Mason Environmental Permit.
This site inspection was to examine the site for potential
development. The property to the south (PN -00951) is
undeveloped, and a development proposal on this parcel must
meet the 100-ft. default shoreline setback. The property to the
north (PN -00905) is developed with a residence, well, septic and
parking areas since 2004, and the development on this parcel
meets the 100-ft. shoreline setback. On the subject properties,
the location of the county road [North Shore Rd.], the easement
path towards Hood Canal on the west, and the steep slopes
immediately to the east of the easement, create some constraints
to further development. The applicant shall measure the depth of
the lots at the property lines and to the access easement to
assess how much space is available to propose development
alternatives. Depending on the size of that available area, a
proposal of a residence, septic system, and parking area to the
west of the easement road may need the evaluation of a
Resource Ordinance regulations Variance from Mason County
Dept. of Community Development. The variance request will
need a public hearing by the Mason County Hearing Examiner, an
eight to ten week review period.
As you ponder your development proposal, a Habitat
Management Plan (HMP), prepared by a qualified biologist, would
be required as part of the variance request to support the
proposed development. The HMP addresses impacts to the
buffer and offers measures to preserve and protect the buffer or to
mitigate impacts of the development proposal. A copy of the Fish
and Wildlife Habitat Conservation Areas chapter, including details
on the contents of an HMP and the variance public review
procedure, is available for review.
Application for a variance to these standards does not guarantee
approval of the development as proposed. The review of a
variance would consider proposed development near the county
road or near the access easement as alternatives, and whether
the limited dimensions and the steep features on the property will
restrict a proposal to meet the Resource Ordinance and Shoreline
Master Program standards.
You would need to confirm with the Health Department what their
septic system standards are to make sure about the adequacy of
supplying a septic system and drainfield area(s).
10/1/2015 Page 4 of 5 SP12015-00057
Site Inspection
10/1/2015 Case No.: SP12015-00057
General process: Future site development must include a site
plan, showing all setbacks from property lines, shoreline, slopes,
and existing and proposed improvements; this site plan will be
needed for building permit application submittal and permit
review. Specific County Codes standards for future development
may be found at the County website address
http://www.co.mason.wa.us. If you have any questions please
feel free to call. Thank you.
10/1/2015 Page 5 of 5 SP12015-00057
RECEIVE -tt4 /lLf
11
JUL 0 2 2015 sP1 0 5- D00 57
ACCEPTED B
426 W. CEDAR ST. MASON COUNTY �11a�
PLANNING DEPT. PRE-INSPECTION APPLICATION
PLEASE PRINT $255.00 Fee Required
1. Site Address: V!/19
Owner: 6UVr CAI LIN 1CANAI7h CA44(j/#-6#, Applicant: NA0 Ag Dll we)z
Owner Address: 916?W MR z fx ✓T. Applicant Address:
City: _ st wh Zip $�D7 City: /' St Zip
Phone: (Y r 1 g ' ��cT� day Phone: ( `t 2 74�, 44 13day Ca-e_e
Phone: ( ) iSAMt evening Phone: ( ) evening
Email Address:arANt.CA/IQI0,d&COJ#<-4.Ile Z Email Address:
2. Parcel#'s -_;0 077
Legal Description: OkY/ll'PIC Ve CV LOTS 3C Sp($y'A I l t TAn W�()
3. Purpose of Pre-Inspection: �D 9TW4W fi �_RWM rrA
ro�VV_ Q A DE�1C awfilytRIN6 �p� hw17 ,yhdRF.�IN� � SETS
4. Use of building: NSA
5. Do any of the following exist on or adjacent to property?: slope saltwater(N lake O river( )
pond ( ) wetland ( ) seasonal runoff( ) other( stream ( ) seasonal creek
Directions to Site: T86 W R I M 5tAk TOAD 852A RGl ME PAJT T-A"VYA,
Q1 W (MAT ut y 1 M11.0 WT 9ND 9F FAVEM10' - a 2,yd W LLy
W h Wg, Ehaf-MOT 5�l�iU �N I�tDy AR nPN to A R87--&M DA�� I
IpTs 'rff IF PAw o ; iT o MAR K g-v 8X 4 No# 05M W6 1-116-
HAM��1�T• R k N f��
If the information is incomplete, then Mason County must disclaim any errors resulting from deficiencies in the original
application. Pre-inspection reports remain valid only until development changes occur in the vicinity, which affect the lot
evaluated in this inspection,or the laws regulating development of the site change after the time of inspection.
Applicant Signature: Date: (e z6 1143
If you would like to be on site during inspection,please check here:
Return application to: Department of Community Development,Planning Division
P.O. Box 279
Shelton, WA 98584
Please include a $255.00 check or money order payable to Mason County Treasurer.
MORE ON BACK SIDE
C:\Users\BLR—I.MAS\AppData\Local\Temp\XPgrpwise\2012 Planning Pre-Inspection.doc
Please illustrate below the proposed building site in relation to critical areas(slopes, streams, lakes,wetlands,etc.)
existing improvements,as well as property lines. APPLICATIONS SUBMITTED WITHOUT ADEQUATE
ILLUSTRATIONS WILL NOT BE ACCEPTED AND WILL BE RETURNED TO THE APPLICANT.
f V/4(s O�
ED
'� 1�d31� f4�z, 1q'33
dz ,r 3o- Z�
Wy Y �y
4
._ k '*..
Departmental Review
(For Office Use Only)
Planning Department Findings:
to �r A'0z'&.z 5 cl&4)-
1014ily' ��A�v
�& PV-
J'A A4 A?4 L j
13 d kv�tA OA�u�t el�
C:\Users\BLR—I.MAS\AppData\Local\Temp\XPgrpwise\2012 Planning Pre-Inspection.doc