HomeMy WebLinkAboutBLD2014-00418 Cancelled Air Handler and HP - BLD Permit / Conditions - 11/16/2014 Inspection Line (360)427-7262
MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County Bldg. 3 426 W. Cedar P.O. Box 279
Irflo Shelton, WA 98584
MECHANICAL PERMIT BLD2014-00418
OWNER: CASIMIRO GARCIA
CONTRACTOR: SUNSETAIR INC. 360.456.4956 LICENSE: SUNSEA*220CM EXP.- 2/3/2015 RECEIVED: 5/10/2014
SITE ADDRESS: 591 E GOSSER RD SHELTON ISSUED: 5/16/2014EXPIRES: 11/16/2014
PARCEL NUMBER: 321367600010
LEGAL DESCRIPTION: TR 1 OF SURVEY 9/12
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
AIR HANDLER AND HEAT PUMP
General Information Setback Information
Type of Use: SF Insp.Area: Front: Ft. Shoreline: Ft.
Type of Work: MEC Fire Dist.: 5 Rear: Ft. Slope: Ft.Side 1: Ft.
Valuation:
Side 2: Ft.
Mechanical Fixtures FEES
Type Qty. Type By Date Amount Receipt
Furnace<100K 1 Final Inspection Fee TW 5/10/2014 $73.00 S220140000(
Heat Pump 1 Mechanical Permit Fee TW 5/10/2014 $36.50 S220140000(
Mechanical Base Fee TW 5/10/2014 $28.50 S220140000(
Total $138.00
BLD2014-00418 Please refer to the following pages for conditions of this permit. Page 1 of 5
CASE NOTES FOR
BLD2014-00418
CONDITIONS FOR
BLD2014-00418
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-098ZXhe person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) Owner/Ag nt is r sponsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
3) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON
STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM
STANDAR SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE.
X
4) In buildings of unusu�ly tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion
air from out�ide in cordance with the international codes.
X 49
5) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC
Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances),
repairs, or jdditio requiring a permit occur, or when one or more sleeping rooms are added or created.
X
6) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit rev tip
BLD2014-00418 Please refer to the following pages for conditions of this permit. Page 2 of 5
7) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the
IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC
systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be
available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal
ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or
rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in
accordance to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection.
Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing
Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
X�
BLD2014-00418 Please refer to the following pages for conditions of this permit. Page 3 of 5
8) Those parts of heating systems that are altered or replaced shall comply with the current IECC/Washington State Energy Code, Section R101.4.3.1.
When a space-conditioning system is altered by the installation or replacement of space conditioning equipment(including replacement of the air
handler, outdoor condensing unit of a split system air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger), the duct system
that is connected to the new or replacement space-conditioning equipment shall be tested as specified in WSU RS-33. The test results shall be
provided to the homeowner AND the Mason County Building Department at the final inspection.
The new and replaced heating equipment shall meet the requirements of the current Washington State Energy Code, applicable sections of the IRC and
IMC.
New and replaced heating equipment shall be sized in accordance to IRC, Section M1401. Heating and design load calculations for the purpose of sizing
HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall
be available for inspection during inspection.
Referencing IRC M1601.4, all new ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be
made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with
flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic.
Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with
flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at
least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions.
Duct tape is NOT permitted as a sealant on any new duct systems. When new ducts are located in unheated spaces the ducts shall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in
accordance to WSEC Section 503.10.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit
forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)."
Duct tightness testing is not required if the air handler and all ducts are located within the heated space.
X
9) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason C u rdinances and building regulations.
X
10) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder h ted action from being taken. No more than one extension may be granted.
X
BLD2014-00418 Please refer to the following pages for conditions of this permit. Page 4 of 5
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION
OF 180 DAYS WILL INVALIDATE THE APPLICATION.
Signature Date
OWNER - REPRESENTATIVE (JCCYNtTRACTOR
Print Name (Circle one to indica
BLD2014-00418 Please refer to the following pages for conditions of this permit. Page 5 of 5
4�^ 4VMASON COUNTY PERMIT NO.,`' _ DEPARTMENT OF COMMUNITY DEVEL0,1MENT
BUILDING•PLANNING•FIRE MARS,yAL
WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352
Mason County Bldg. III, 426 West Cedar Street (360)275-4467 Belfair ext.352
4 ��` PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352
PLUMBING & MECHANICAL PERMIT APPLICATIONOu
G(� �
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: NAME: h ej- &i r UnU
MAILIN ADDRESS: - F MAILING ADDRESS: 1? C� G b
CITY: STATE: ZIP: a? qf V/ CITY: ID(IL, STATE:k)6{ ZIP: p
PHONE: CELL: ++ PHONE: CELL:
EMAIL: EMAIL : r1
Yn Oyu eUY�o - U 1 -5a (P y t I L&I REG#�5LtX1S9ft a lY►'1 EXP.
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER):
LEGAL DESCRIPTION(ABBREVIATED). - t l.(f vp
SITE ADDRESS: � 1L CITY:
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB
NEW ADD ALT REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS- 1 FLOOR 2ND FLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
Bath Tubs Heatpump
Showers Spot Vent Fan
Water Heater Propane Tank _
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hosebibs Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICA
OWNER I BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revo
Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including
any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is
suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERM CATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
PPLI
X �i
Signva�
of Applicant Date
X Owner/Owners Representative/Contractor
Prin ame (indicate which one)
btI'A3 imN NTA L REVIE 6TkWdNbPI'I.ON§
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL