HomeMy WebLinkAboutFIR2019-00027 - FIR Inspections - 2/28/2024 � 1
�► Mason County
Mason County - Division of Community Development
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
F
-00027 FIRE PROTECTION SYSTEMDESCRIPTION: FIRE SUPPRESSION SYSTEM HOOD IN ISSUED: 01/08/2020ESS: 1060 W EELLS HILL RD SHELTON EXPIRES: 07/06/2020
PARCEL: 420042400000
APPLICANT: THE RIDGE MOTOR SPORTS GROUP LLC OWNER:
P.O.Box 2467
SHELTON,WA 98584
1.360.427.7223
GENERAL CONTRACTOR'S LICENSE: KNIGHT FIRE PROTECTION INC License: KNIGHFP044LK
9702 LATHROP INDUSTRIAL DR SW Expires: 05/25/2020
TUMWATER,WA 98512-9188
1.360.786.8606
FEES: Paid Due
Fire Protection Permit Fee $190.00 $0.00
Fire Protection Plan Check $123.50 $0.00
Totals : $313.50 $0.00
REQUIRED INSPECTIONS
Fire Marshal Final Underground Inspections (Fire)
Residential Sprinkler System Underground Inspections-Final (Fire)
Commercial Sprinkler System Wet Fire Pump Inspection
Commercial Sprinkler System Wet-Final Commercial Fire Alarm-Final
Commercial Sprinkler Dry Hood/Suppression System Inspection
Commercial Sprinkler Dry-Final Hood/Suppression System Inspection-Final
CONDITIONS
Printed by:Genie Mcfarland on:01/08/2020 01:18 PM
Page 1 of 2
f y
Mason County
g Mason County - Division of Community Development
615 W.Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
FIRE PROTECTION SYSTEM FIR2019-00027
* Fire Marshal Comments:
1. The hood and duct suppression system shall be inspected for final approval by the Fire marshal.
2. All owners guides, Users Manuals,As-Builts and Installation paperwork shall be left on-site in a box indicated as
"Appliance Documents: for reference.
3. Hood and Duct suppression system shall be conned to the building fire alarm system and shall report as a separate
circuit.
4. A class K fire extinguisher shall be provided and installed within close proximity to frying operations.
5. The manual pull station shall be installed in the path of egress and shall be in a conspicuous location.
* All Material Safety Data Sheets (MSDS)for all hazardous materials used within the facility shall be placed in a notebook
and permanently located in a conspicuous location inside the building near the main entrance. (IFC Chapter 50)
X
* All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
* All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
I
provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or dorized Agent: Date: I U
Printed by:Genie Mcfarland on:01/08/2020 01:18 PM
Page 2 of 2
Nw INSPECTION CARD
Mason County
615 W. Alder St. Bldg. 8, Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
PERMIT# FIR2019-00027 PROJECT ADDRESS 1060 W Eells Hill Rd Shelton, WA 98584
PARCEL# 420042400000 PROJECT DESCRIPTION FIRE SUPPRESSION SYSTEM HOOD IN CAFE
OWNER ADDRESS PHONE
CONTRACTOR KNIGHT FIRE PROTECTION INC ADDRESS 9702 LATHROP INDUSTRIAL DR SW PHONE 1.360.786.8606
CONTRACTOR LICENSE KNIGHFP044LK LENDER
INSPECTION INSP DATE Comments 1 INSPECTION INSP DATE Comments
Fire Marshal Final Underground Inspections (Fire)
Residential Sprinkler System Underground Inspections-Final
!Commercial Sprinkler System Fire Pump Inspection
Commercial Sprinkler System Commercial Fire Alarm-Final
iommercial Sprinkler Dry Hood/Suppression System
iCommercial Sprinkler Dry-Final Hood/Suppression System
Randy Collins
From: Randy Collins
Sent: Wednesday, February 28, 2024 11:27 AM
To: 'tracie@ridgemp.com'
Subject: Old Fire Permit
Hi Tracie,
I am contacting you because I am trying to finalize a number of permits that were issued before I became the
County Fire Marshal. One of those that I found was for a Range Hood Fire Extinguishing System that was issued in
September of 2019 for your facility Permit#FIR2019-00027).While plans were approved by this office,there is no
record an inspection had ever occurred.To that end, I wanted to ask if I could perform and inspection so the
permit could be signed off.The scope of the inspection would be to verify the following:
• The system matches what is on the approved plans.
• The system is current with the servicing required under the State law.
• There is a Class"K"fire extinguisher present.
Thank you for your time and consideration and I look forward to hearing from you.
Respectfully,
Randy Collins
Fire Marshal
Mason County
360 427-9670 x309
360 490-0167 Cell
1
. k
9-M MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT
FIRE MARSHAL
Mason County Bldg. Vill,
615 W ALDER Street, Shelton. WA 98584
I@(
www.co.mason.wa.us Shelton (360)427-9670 Belfair(360)275-4467 Elma (360)482-5269
Date:09/12/2019
Building Permit Number:FIR2019-00027
Parcel number:42004-24-00000.The Ridge Motorsports Park
PLAN REVIEW REQUIREMENT COMMENTS:
1.The hood and duct suppression system shall be inspected for fmal approval by the Fire Marshal.Call 360-432-5170 to
schedule the appointment.Allow 2 days lead time.
2.All owner's guides,User's Manuals,As-Builts and Installation paperwork shall be left on-site in a box marked
"Appliance Documents"for reference
3.The hood and duct suppression system shall be connected to the building fire alarm system and shall report as a
separate circuit.
4.A Class"K"fire extinguisher shall be provided and installed within close proximity to flying operations.
5.The manual pull station shall be installed in the path of egress and shall be in a conspicuous location.
If you have questions,please contact the Mason County Permit Center office at(360)427-9670 ext.352.
Sincerely,
Mike Patti
Mason County Department of Community Development
Interim Fire Marshal
C
OPT(
MASON COUNTY FIR2011
-,' DEPARTMENT OF COMMUNITY DEVELOPMENT
4�-
-- Mason County Bldg. 111, 426 West Cedar Street, Shelton, WA 98584
www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma(360)482-5269
AasonRcinty Fire Protection System Permit Application/Underground System
P� Incomplete applications will not be accepted
0 I' L LCI
Owner: d 0 v Phone#:
Mailing Address: d. )( . 4b rl City: Stater Zip:'1658`4
4u�'L Q
Site Address: I� ,L) ��� City: Statetij.AZip..
Parcel #: )4— QUO Legal Description:
Address: City: State: Zip:
Contractor: ni4k IrO+x/—fid Ph ne#:
nciu� n.�
Address:�i�16� (�-�hl�0 City: StateW6— Zip: ,Yb
Contractor Registration#: K n 1 1,11,h F Po 44 Expiration Date:
Building-Square Footage (existinLY&proposed): I' / 2nd / 3rd /
Building Use Occupancy Classification: Construction Type:
e�nn w oe.#, C�Fi=
Type of System: Type of Work:
Sprinkler: New System:
Wet Dry Modification:
Standpipe:
Wet Dry Fire Underground
Automatic Fire Alarm: Fire Pump
Hood &Duct:
Dry Chem:
Wet Chem:
UL certified Monitoring compann Adu Phone#:�I#b •ql (b (441
Contractors Bid Price: $ ri 500 DO
IACommunity DevelopmenABUILDINGTire Protection System Permit Application.doc
Plan Submittal Requirements
Your plan submittal shall include the following_
1. Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow.
2. Site and Floor plan with cross sectional and exterior elevations.
3. Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces,etc.
4. Cut sheets and/or references for all new devices.
5. Location/description of all new and existing devices.
6. Battery calculations.
7. Wiring diagrams per floor or zone overlaid on an accurate floor plan.
8. Electrical riser diagram showing all zones, circuits, devices, and end—of—line resistors.
9. Hydraulic calculations.
10. Copy of Contractors bid.
11. Underground Systems;
a) NICET FPE Certification
b) Underground Civil drawings
c) Bedding detail
d) Truss blocking/Mega Lugs detail
e) Depth/Material for burial
fl Pipe size and Type
Fees
The permit fee will be assessed based on the submitted contractor bid for the project.
A plan review fee will be calculated at 65% of the permit fee.
Contractor's Affidavit
I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance
requirements regulating the work for which the permit is issued and certify that all work will be in compliance
with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire
Marshal.
By: Date:
IACommunity DevelopmentWILDINGTire Protection System Permit A.pplication.doc
DATA SHEET Pyrom
Chem
KITCHEN KNIGHT II
Restaurant Fire
Suppression Systemi ILE
copy
Features
■ UL and ULC Approved �pPROVED
■ Complies with NFPA Standard 17A an(d�9 �N ARE
■ Meets the requirements d��irh— `Bf(TCi'�IiF_Cod"e MARSHAL
Administrators (BOCA) DATE EjY
■ Meets the requirements cfm iooii Efo�C PE TI
(IBC) ALL APPLICABLE CODES SHALL APPLY. ERRORS
■ Approved by the New Yor o�4z 2
J(�jfvjbifplM�gpgV6�+bPta+91NS ARE SOLE ESPON-
Certificate of Approval (C%N&?1JF OWNERICONTRACTOR.CORR CTIONS
■ CE Marked REQUIRED FROM FIELD INSPECTION SHAL BE feral
OWNER/CONTRACTORS EXPENSE.THIS All PR9WITCHEN KNIGHT II Restaurant Kitchen Fire Suppression
DOES NOT GRANT TO ANY PERSON THE R HTS em is a pre-engineered solution to appliance and ventilating
OPTIONAL CYLINDER ENCLOSUREVIOLATE ANY CITY,COUNTY OR STATE LAWS.hood and duct grease fires.The system is designed to maxi-
mize hazard protection, reliability, and installation efficiency.
TO DISCHARGE y PIPNG Automatic or manuals stem activation releases a throttle
TO REMOTE MANUAL discharge of potassium carbonate solution on the protected
PULL STATION area in the form of fine droplets to suppress the fire and help
To prevent re-ignition after the discharge is complete.
FUSIBLE /TO GAS VALVE
LINKS �/ SHUT-OFF
Ila
® F=1 _
O
00 =
28.125 IN. OPTIONAL
(714 mm) MINIATURE
SWITCH C:
CONNECTION
B
D
13.125 IN.j�'
+_10.625 IN.�—(333 mm) TO GAS (270 mm)
(FRONT) SHUT-OFF (SIDE)
0048e2 }+—A oo2d01c
Mounting
Model A B C D Flow Point Weight Bracket
No. in. (mm) in. (mm) in. (mm) in. (mm) Capacity I (kg) Used
PCL-160 8.00 (203) 17.75 (451) 23.50 (597) 15.44 (392) 5 34 (15) MB-15
PCL-300 8.00 (203) 25.06 (637) 30.81 (783) 22.75 (578) 10 53 (24) MB-15
PCL-460 10.00 (254) 25.06 (637) 30.81 (783) 22.75 (578) 15 83 (38) MB-15
PCL-600 10.00 (254) 35.81 (910) 1 41.56 (1,056) 33.50 (851) 20 1108 (49) MB-1
One Stanton Street I Marinette,WI 54143-2542,USA 1 +1-715-735-7411 1 wvvw.l)yrochem.com �/J �(
2017 Johnson Controls.All rights reserved.All specifications and other information shown were Johnson ' ,�`I
current as of document revision date and are subject to change without notice. I Form No.PC2001192-07 Controls
_0
System Operation Suggested Architect's Specifications
The KITCHEN KNIGHT II Restaurant Kitchen Fire Suppression The fire suppression system shall be of the stored pressure,
System has been designed for protecting kitchen hood, plenum, wet chemical pre-engineered fixed nozzle type manufactured
exhaust duct,grease filters,and cooking appliances(such as by Johnson Controls. A carbon dioxide cartridge shall be used
fryers,griddles, rangetops, upright broilers,charbroilers and as the pneumatic releasing device for the system.The cartridge
woks)from grease fires. The versatile state-of-the-art wet shall be an integral part of the control head assembly. The wet
chemical distribution technique, combined with dual, indepen- chemical storage cylinder shall be a DOT-rated cylinder for
dent activation capability—automatic fusible link or manual stored pressure of 225 psig (15.5 bar), and a pressure gauge
release—provides efficient, reliable protection the moment a shall be provided on the cylinder valve for visual inspection.
fire is detected. Once initiated,the pressurized wet chemical The system shall be capable of automatic and manual actua-
extinguishing agent cylinder discharges a potassium carbonate tion. Automatic actuation shall be provided by an appropriate
solution through a pre-engineered piping network and out the number of fusible link detectors mounted in series on a stainless
discharge nozzles.The wet chemical discharge pattern is main- steel wire input line to the control head. Manual actuation shall
tained for a duration of time to ensure suppression and inhibit be provided by turning a handle on the cylinder control head
re-ignition. Expanded capability provides remote manual actua- cover, if available, and/or remotely by a cable operated pull
tion, gas equipment shutdown, and electrical system shutdown. station with a dedicated stainless steel line connected between
This optional equipment will enhance the basic system func- the pull station and the control head mechanism.
tions and be applicable when designing custom configurations
to suit a particular customer's needs and/or comply with local The system shall have been tested to the UL Standard for Fire
codes. Extinguishing Systems for Protection of Restaurant Cooking
Area, UL300, and Listed by Underwriters Laboratories, Inc. It
The operating temperature range of the PYRO-CHEM KITCHEN shall be installed in accordance with the National Fire Protection
KNIGHT II System is 32'F to 120'F(0'C to 49°C). Association standards, NFPA 17A Standard for Wet Chemical
Systems, and NFPA 96 Standard for Ventilation Control and Fire
Protection of Commercial Cooking Operations, and comply with
all local and/or state codes and standards. Refer to
PYRO-CHEM KITCHEN KNIGHT II Restaurant Fire Suppression
System Manual, Part No. 551274,for detailed installation and
maintenance instructions.
Typical Installation
6
2
4
�O
3
�� PC98146
Typical Installation (Continued) 7. Automatic Gas Shut-Off Valve—Complies with require-
ments pertaining to the shut off of fuel as described by
1. Cylinder Control Head—Integral design allows direct NFPA 17A. Can be reset at control head after regular main-
connection of the actuation pressure cylinder to the control tenance/service check for convenience of service technician.
head without the need of high pressure hose or pipe. Maximum limitations of 100 ft(45.7 m)cable run with
Separate wire cable activation lines for automatic fusible 30 corner pulleys provide mounting flexibility.
links and remote pull station provide an added measure of The gas shut-off valve is compatible with flexible conduit.
safety. Unique technique for achieving necessary input wire
cable tension. 8. Corner Pulleys And Accessories—Designed to ensure
2. Piping Unbalanced piping network simplifies application reliable system function as tested by Underwriters
design and installation. Requires no additional piping to Laboratories.
connect system pressure cylinder to extinguishing agent 9. Agent Distribution Hose(Not Shown)—Kitchen appli-
container. Schedule 40 black iron, chrome-plated, or stain- ances manufactured with or resting on caster(wheels/
less steel pipe can be used. rollers) include an agent distribution hose as a component
3. Cylinders—Contain PYRO-CHEM Potassium Carbonate wet of the suppression system. This allows the appliance to
chemical solution stored at 225 psig (15.5 bar). Includes be moved for cleaning purposed without disconnecting the
pressure gauge for visual maintenance checks. 1.6,3.0,4.6, appliance fire suppression protection. The hose assembly
and 6.0 gallon sizes provide 5, 10, 15, and 20 flow point includes a restraining cable kit to limit the appliance move-
coverage respectively,offering a broad range of application ment within the range (length)of the flexible hose.
coverage. 10. Flexible Conduit(Not Shown)—Flexible conduit allows for
4. Nozzles—Can be fixed or fitted with a swivel adaptor allow- quicker installations and the convenience of being able to
ing the nozzle to be rotated approximately 30' in all direc- route the cable over, under and around obstacles. Flexible
conduit can be used as a substitute for standard EMT
lions. conduit or can be used with EMT conduit.
5. Remote Manual Pull Station—Simple operating instruc
Flexible conduit can be used only with the Remote Manual
tions with double action release minimizes accidental
Pull Station and Mechanical Gas Valves.
manual operation of the system. Maximum limitations of
150 ft(45.7 m) cable run with 1/16 in.cable and 40 corner
pulleys apply. A dedicated wire cable input line to the cylin- Note:The converted values in this document are provided for dimensional
reference only and do not reflect an actual measurement.
der control head provides manual operation in addition to
automatic operation utilizing fusible link detection. PYRO-CHEM,KITCHEN KNIGHT,and the product names listed in this
material are marks and/or registered marks.Unauthorized use is strictly
The pull station is compatible with flexible conduit. prohibited.
6. Fusible Link Detection Equipment—Accommodates both
series and terminal placement to minimize inventory and
simplify ordering. All necessary components are included
for efficient assembly and installation. Fusible links rated
for maximum ambient temperature must be ordered sepa-
rately. Maximum limitations of 20 fusible links on a
150 ft(45.7 m) cable run with 40 corner pulleys provide
substantial hazard coverage.
$ r
•ojA #
d
"may
Ilk—
r� F
rro '1Y f�r�
3„
. t
r
a
e
.,el��� r� ,.�•�h'«" � �=� 1. '�- �"'' '�" ri'�` � yr"
,
t
�N
��. r
The KITCHEN KNIGHT II system offers
breakthrough technology enhancing the
industry's most flexible and effective
suppression system.
Extended Coverage _ $x
Back Shelf Protection
Enhanced Components
■ DOT Rated Cylinders
■ Flexible Conduit • • • . , •
:r �,?.:r'..: .,i�j aY E'.,i.4€ti.. a ..,i3 a.z._ • • •
Piping Flexibility •
• incorporates 1/4 to 3/4 inch pipe •-•• -"
■ Simple piping rules . . . .
■ Flexible distribution hose • • - •
Wet Agent Technology
The system employs a potassium carbonate- • • • " •
based wet agent that knocks the flame down,
cuts off air to the burning grease and cools
the hazard area to help ensure the fire stays
out.
v
Trained Distributors
PYRO-CHEM distributors have been
extensively trained in system design,
installation and maintenance. � =�
Make the KITCHEN KNIGHT II system
part of your fire protection plan.
KITCHEN KNIGHT 11 systems
tiN..
offer a complete menu of cost
effective fire protection
components.
Automatic detection and actuation controls
provide 24-hour protection.
Dedicated manual pull station allows
immediate actuation at the first sign of fire
and provides backup to the automatic
detection system.
Pressurized DOT rated steel cylinders ready
for release in the event of a fire.
Pressure gauge on the agent cylinder allows -�-
visual inspection of system status.
Fully assembled and 100% tested {
mechanical control head, cylinder valve, and
gas shut-off valve provide reliable operation.
Flexible piping configurations allow fora
streamlined design that will not interfere
with kitchen workflow.The system can be
mounted in out-of-the-way areas to preserve
valuable kitchen space.
Protective chrome nozzle caps help protect
against contamination and blockage by
grease or other cooking byproducts that can
inhibit the proper discharge of extinguishing
agent.
The KITCHEN KNIGHT II system is available
in a variety of sizes economically suited to
fit specific needs, and designed with the The flexible agent distribution
flexibility to accommodate changes to hose provides the freedom to
appliance layout or the expansion of a clean beneath and behind
cooking area. "castered" appliances without
disconnecting fire suppression
piping. The hose allows up to 3
Tested and approved by the most ft. (0.9 m) of movement and is
particular connoisseurs supplied with a restraining cable
to help prevent over-extension.
PYRO-CHEM KITCHEN ONE fire
extinguishers use the same wet
chemical agent as is used in the e ..
KITCHEN KNIGHT II
Suppression System. Should
fire occur in the kitchen, the fire
suppression system must be ,w
activated first, and the KITCHEN
ONE hand portable extinguisher ,..4
used as a backup.
Detection Brackets and Fusible Links --
A variety of temperature ratings allow for Chrome Nozzles and Caps --
customized detection options Less to choose from means less inventory
Pull Station -- w;, . y`` ,, to manage and greater flexibility
Allows manual actuation at a
safe distance from the hazard
Flexible Conduit
Easy installation.
Replaces rigid conduit
between the control
head and pull station
Pyro
�hsmt r` and/or control head
and gas valve
i_�
PCL 160, 300, 460 and 600 Cylinders --
Increased Agent Capacity — more
volume and flow points
Gas Shut Off Valves --
Optional 304-grade Control Heads -- Electrical or mechanical designs
stainless steel enclosure -- Easy to install. Multiple designs automatically cut off fuel supply
Encases the agent cylinder and activated by a fusible link, thermal to hazard area
discourages tampering detector or manual pull station .; .,
�n S
x. �,h�aye �.t : A i.•�-
-
+1-800-526-1079
(USA/Canada) Fire Protection Products
+1-715-732-3465
(International)
www.pyrochem.com
One Stanton Street / Marinette,WI 54143-2542,USA / +1-715-735-7411 / www.pyrochem.com
Copyright U 2013Tyco Fire Products LP. / All rights reserved. / Form No.PC2001207(7)
OWNER'S GUIDE
PYRO-CHEM® KITCHEN KNIGHT® II
c RESTAURANT FIRE SUPPRESSION SYSTEM
Chem UL EX 3830 1-22-2009 Page 1
The National Fire Protection Association (NFPA) recom- 1, 6. Never operate filter-equipped exhaust systems without
mends that employees be instructed in personal safety and the filters in place. Excessive grease may build up in
the operation of the system. PYRO-CHEMs provides this the hood and duct system. Cooking with filters removed
owner's guide with each Restaurant Fire Suppression can impact air movement and/or temperatures, which
System. may result in system discharge. Use only UL listed
This owner's guide has been provided to help you under- filters.
stand: 7. Never restrict air intake passages; this can reduce the
• How your restaurant system works efficiency of your exhaust system. Cooking with filters
that contain excessive amounts of grease can impact
• Your responsibilities for maintenance air movement and/or temperatures, which may result in
• What to do in case of fire system discharge.
This owner's guide is not intended to cover all requirements 8. Operate all UL tested grease extractors by the manu-
detailed in the Installation, Operation, Recharge, facturer's instructions to ensure effective grease
Inspection, and Maintenance Manual, Part No. 551274. removal from the hood and duct system.
This guide is solely for the use of the end-user to become 9. Never tamper with the system components (i.e., detec-
more knowledgeable with the fire suppression system and tors, nozzles, agent tank assembly(s) or control
the steps necessary in the event of a fire. head(s).
Should the end-user want to find out more information 10. Before you revise your kitchen equipment layout or
concerning the KITCHEN KNIGHT® II Restaurant Fire make changes which affect the basic configuration of
Suppression System, your authorized distributor can furnish the protected area, contact your trained, authorized
a detailed Installation, Operation, Recharge, Inspection, PYRO-CHEM distributor for a system update evalua-
and Maintenance Manual. tion. The system is made up of components tested
within limitations contained in the detailed installation
manual. The system designer must be consulted when-
YOUR ROLE IN FIRE PROTECTION ever changes are planned for the system or area of
Your PYRO-CHEM Fire Suppression System is of the protection.
highest quality. It has been carefully engineered to be reli- 11. Do not allow anyone except an authorized
able, manufactured to exacting standards, and custom PYRO-CHEM distributor to perform maintenance on
designed to protect your particular hazard. your PYRO-CHEM system. Maintenance to your
If properly maintained, your system should provide years of system must be performed semi-annually. It is essential
protection. However, the primary objective of this guide is to that the system be maintained properly.
provide enough basic information to help you to prevent a 12. Post operating instructions in an obvious place in the
disastrous fire. By observing some fundamental rules, you kitchen and make sure your employees know what to
can greatly reduce the risk of serious fire damage. do in case of fire.
1. Keep all kitchen equipment free of grease build-up. 13. Make certain that hand portable extinguishers are prop-
2. Never use flammable solvents or cleaners. Flammable erly placed and compatible with the restaurant system.
residues could be left in the hazard area. Class K extinguishers must be provided for hazards
► 3. Never store flammable materials near cooking equip- where there is a potential for fires involving combustible
ment or gas flue areas. cooking media (vegetable or animal oils and fats). An
authorized PYRO-CHEM distributor can assist your
4. Make certain obstructions, such as utensils, pots, pans, needs.
cooking materials, etc. are not stored in areas that can
obstruct the fire suppression system discharge.
► 5. Operate your exhaust system whenever the appliance
is pre-heating, heating, cooking or cooling. This helps to
prevent excessive heat build-up which could actuate
the system.
PN551017(4)
OWNER'S GUIDE
PYRO-CHEM® KITCHEN KNIGHT®II
RESTAURANT FIRE SUPPRESSION SYSTEM
UL EX 3830 1-22-2009 Page 2
DUCT
Circular,square,or
rectangular sheet metal
structure to exhaust cooking
vapors to outside air.
HOOD
Collection area to funnel
grease laden vapors to the
duct.The plenum area of the
hood(behind the filters)
must be protected.
COOKING APPLIANCES
All types of cooking appliances FUEL SHUT-OFF DEVICES
should be protected,including deep Equipment should be provided to ensure
fat fryers,griddles,ranges,and fire control by automatically shutting off
broilers.Radiant,lava rock,and energy sources to cooking equipment
upright broilers should also be (gas or electric).
protected. 00779e
HOW THE PYRO-CHEM KITCHEN KNIGHT II SYSTEM 4. At daily intervals check your system for loose pipes and
OPERATES ► missing or grease-covered nozzle caps. Temporarily
1. A fire starts in the protected area.... I remove cap and check to make certain it is not brittle,
2. Heat sensitive fusible link detectors activate the system. and snap back onto nozzle. Make certain nozzle caps
are in place over the ends of each nozzle.
3. Appliance energy sources are automatically shut off by Note: If caps are damaged or missing, contact the
accessory equipment appropriate for the type of fuel I authorized PYRO-CHEM distributor for immediate
used by your cooking equipment.
► replacement.
4. The fire extinguishing agent is discharged into the 5. Check each metal blow-off cap and make certain the
plenum and duct and onto the cooking appliances. cap can be turned freely on the nozzle.
5. The agent and the hot grease mix to form a foam. This 6. Periodically check your visual indicator on the releasing
temporarily seals combustible vapors, helping to inhibit unit to make certain the system is in set position.
re-ignition.This seal must not be disturbed.
7. Have your system inspected by an authorized
PYRO-CHEM distributor at a maximum of 6 month
INSPECTING YOUR KITCHEN KNIGHT II SYSTEM intervals and immediately after major hood and duct
Your PYRO-CHEM KITCHEN KNIGHT II system should be cleaning. Often fusible links are wired shut during the
inspected at least monthly. Should you discover any cleaning process to prevent accidental activation. This
irregularities, contact an authorized PYRO-CHEM will prevent the system from operating automatically. It's
distributor immediately. also possible that your system might have been discon-
nected, damaged, or has accumulated excessive
1. Never use corrosive cleaning solutions on the fusible deposits of grease causing your system to become
links or cables. Check to make certain there is no corro- inoperative.
sion to any of the detection system components.
Certain high alkaline cleaners could cause corrosion. 8. Check that the manual pull station is not obstructed,
has not been tampered with, and is ready for operation.
2. Ensure that metal fusible links are replaced semi-annu-
ally. Deterioration of these links could cause the system 9• Make certain that each tank and releasing unit is
to be actuated or to malfunction in case of a fire. mounted in an area with a temperature range of 32 °F
to 120 OF(0 °C to 49 °C).
3. Make certain the releasing unit has not been tampered
with, and that visual inspection seals are not broken or
missing.
OWNER'S GUIDE
PYRO-CHEM® KITCHEN KNIGHT® II
RESTAURANT FIRE SUPPRESSION SYSTEM
UL EX 3830 1-22-2009 Page 3
INSPECTING YOUR KITCHEN KNIGHT II SYSTEM 3. Call the local fire department or emergency number.
(Continued)
10. Make certain the agent storage tank is not in an area in
which the temperature can exceed 120 °F (49 °C) or
can be heated to a temperature exceeding 120 °F
► (49 OC) due to conductivity through heated discharge
piping.
IN THE EVENT OF FIRE IN THE PROTECTED AREA
1. Evacuate others from the premises. In a loud, clear
voice say: "WE HAVE A FIRE — PLEASE LEAVE THE
BUILDING CAREFULLY, BUT QUICKLY."
001636
► 4. Stand by with a KITCHEN ONE® Wet Chemical hand
EXIT portable fire extinguisher.
If you need to use it:
litIf a. Pull pin
b. Stand back 10ft(3.1 m)
c. Aim at base of fire, squeeze handle and sweep side
to side
001633Pc
2. If the automatic actuation has not yet taken place,
operate the system manually as follows:
• Pull handle or pull ring straight out on manual pull
station with enough force to actuate the fire suppres-
sion system.
_ 410FT
001636
CAUTION
► 1. Do not attempt to extinguish a grease fire with a
hand portable fire extinguisher before the Fire
Suppression System has been manually or auto-
matically actuated.
► 2. Do not discharge wet chemical agent from the
KITCHEN ONE Wet Chemical hand portable fire
007B03 extinguisher unless the fire suppression system
Once the fire suppression system is actuated, equip- will not operate or a re-flash has occurred.
ment to shut off the fuel supply to the cooking appli-
ances will operate. 3. Do not attempt to use a Class ABC Multipurpose
Dry Chemical, CO2, or Water type hand portable
fire extinguisher in/on an application with burning
cooking oil or grease.
OWNER'S GUIDE
PYRO-CHEM® KITCHEN KNIGHT® II
RESTAURANT FIRE SUPPRESSION SYSTEM
UL EX 3830 1-22-2009 Page 4
BEFORE RESUMING BUSINESS 3. Using hot, soapy water and either a clean cloth or
1. Immediately after discharge, call your authorized sponge, wipe away all foamy residue and thoroughly
PYRO-CHEM distributor to inspect and recharge your scrub all surfaces that have come in contact with the
Fire Suppression System. agent.
2. Have your PYRO-CHEM distributor determine the 4. After thoroughly cleaning all affected surfaces,
cause of the system actuation. adequately rinse and allow to completely dry before re-
3. Area must be cleaned up within 24 hours after energizing the equipment.
discharge using warm water and cleaning detergents.
WARRANTY
CLEANUP PROCEDURES A. PYRO-CHEM KITCHEN KNIGHT II Products
Although there is no unusual cleanup procedure for Except as indicated in B below, your KITCHEN KNIGHT II
PYRO-CHEM wet agents, due to the alkaline nature of System is warranted to you as the original purchaser for
these agents, they should be cleaned from kitchen surfaces three years from date of delivery against defects in work-
within 24 hours after system discharge. The reaction from manship and material. PYRO-CHEM will replace or repair
the wet chemical agent on cooking grease or oil produces a any metal part which, in its opinion, is defective and has not
foamy bi-product that can be wiped up with a cloth or been tampered with or subjected to misuse, abuse or
sponge. The following procedures should be followed: exposed to highly corrosive conditions.
B. Purchased Products
CAUTION A The following items which are not manufactured but
purchased by PYRO-CHEM are warranted against defects
1. Before attempting any cleanup, make certain that all resulting from the manufacturer's fabrication, process or
fuel sources to the equipment to be cleaned have been parts for one year from the date of purchase: detectors,
shut off. Make certain that the exhaust hood and all electric manual pull station, time delay relays, thermostats,
appliance electrical controls have been de-energized solenoids, switches, and fuel shut-off valves. Evaluation of
to avoid any chance of electrical shock resulting from each reportedly defective relay, valve, etc., returned to
the cleaning process or from electrically conductive PYRO-CHEM will be made by the original manufacturer or
alkaline liquid agent and/or its residue. an agent thereof and their judgment shall be final.
► 2. Make certain all surfaces to be cleaned have cooled C. Except as provided in A and B, there are no warranties,
down to room temperature. express or implied made by PYRO-CHEM, concerning
► 3. Do not use water to clean any appliances that contain this system. There are no implied warranties of
hot grease or cooking oils. Doing so may result in FITNESS FOR PURPOSE OR MERCHANTABILITY.
violent steaming and/or spattering. PYRO-CHEM shall have no liability for consequential,
special or similar damages.
► 1. The fire suppression system agent is non-toxic; For repairs, parts and service of the PYRO-CHEM System,
however, food product and cooking grease/oil that has contact your local PYRO-CHEM representative, or
come in contact with the agent will no longer be suitable PYRO-CHEM, Marinette, Wisconsin 54143-2542; 800-526-
for human consumption and should be discarded. 1079 or(715) 732-3465.
2. Sponge as much of the agent as possible using
sponges or clean rags. Dispose of these sponges or
► rags in a local sanitary land fill site in accordance with
local authorities.
Note: Wear rubber gloves during cleanup as sensitive
skin may become irritated. If the PYRO-CHEM
wet agent agent or its residue comes in contact
with skin or eyes, flush thoroughly with clean
water.
PYRO-CHEM,KITCHEN ONE,and KITCHEN KNIGHT are trademarks of Tyco International Ltd.or its affiliates. Copyright 02009 Tyco International Ltd.