HomeMy WebLinkAboutFIR2023-00029 - FIR Inspections - 11/1/2023 (2) Mason County Fire Marshal 615 W. Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 Ilk Fire Alarm Certification/Final Test FIR 23-U�Z� Location: /D/ : y /,:7� S/>�foq Contractor: Phone#: ,0- Contact: Test Date: 2.3 CHECKLIST N Verify panel is in "Normal" condition and clear of any signals Kill Power At Electrical panel & verify dedicated circuit, red breaker& lockout 123% AC Trouble/ No Power displayed? Activate device(s),verify it activates the alarm and shows correctly on the panel Check the Notification Alarm Circuit (NAC) for activation of devices. Walk building while alarm is activated under battery load. Check for all lights and sounds to be in-sync .� Silence Alarm �—Activate a few other devices in different areas to verify alarm reactivates after being silenced Reset Alarm Does panel still show trouble (due to AC power)? Disconnect Signal Loop Circuit (SLC) to create/verify a trouble for each device on circuit -- Reconnect SLC. System should reset & only AC trouble showing Disconnect the communication line &verify communication trouble Do batteries AMP/HR match plans? L 9i1W.5,P uX,-,1- Z FACP Sign on Door(s) leading to panel location? Device Test Log Notification Device Time Comments Water flow Inspectors test Smoke detector at FACP Tamper switch 1 Tamper switch 2 Manual pull at /Z=4 Manual pull at Manual pull at Heat Detector S3 Heat Detector Heat Detector Heat Detector Heat Detector Smoke Detector Smoke Detector /7 4/,,Lt7, 1,7 SK Smoke Detector Smoke Detector /� l Punch List/Comments: /�/ion���r'o�if'o����.��5 /u�i�J��ZJ��s�l�f�� s%,20 14, i ��i�uX �cx ,orr�v�� ���s �a �tir� c,�✓s r� G�i��� Passed Final Test? Yes ✓ No RECEIVED MASON COUNTY FIR20913- 000 COMMUNITY SERVICES SEP 12 2023 Building,Planning,Environmental Health,Community Health 615 W. Alder Street FIR Mason County Fire Protection System Permit Application/Und&`g�b d System Incomplete applications will not be accepted Owner: Ti�� Phone#: 1 ,0 Mailing Address: Z69l S�j'� T City: State Zip: �1 Site Address: Zz9l 2!1 T y 4 r. City: //� A? State:01=4-ip:� Parcel #: Legal Description: 0 h Contractor:s�1)1�1 (,'� I—j e-- Phone#z � Address: Xg,7 City: Q nn State:"g Zip: Contractor Registration#: Expiration Date: 20 nd rdBuildin Square Footage(existing&proposed): is 2 / 3 / Building Use: 0 , -C m-2 ( Occupancy Classification: Construction Type: Type of System: Type of Work: AUstj^ Sprinkler: New System: Wet Dry Modification: f< ZIC� /,j Standpipe: /Wet Dry Fire Underground 7 Automatic Fire Alarm: Fire Pump Hood & Duct: S-A 4- Dry Chem: 360. 357_ Coll Wet Chem: UL certified Monitoring company: Phone#: Contractors Bid Price: srU IACommunity DevelopmenAMLDINGTire Protection System Permit Application.doc Plan Submittal Requirements Your plan submittal shall include the following: 1. Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow. 2. Site and Floor plan with cross sectional and exterior elevations. 3. Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces, etc. 4. Cut sheets and/or references for all new devices. 5. Location/description of all new and existing devices. 6. Battery calculations. 7. Wiring diagrams per floor or zone overlaid on an accurate floor plan. 8. Electrical riser diagram showing all zones, circuits, devices, and end—of—line resistors. 9. Hydraulic calculations. 10. Copy of Contractors bid. 11. Underground Systems; a) NICET FPE Certification b) Underground Civil drawings c) Bedding detail d) Truss blocking/Mega Lugs detail e) Depth/Material for burial f) Pipe size and Type Fees The permit fee will be assessed based on the submitted contractor bid for the project. A plan review fee will be calculated at 65% of the permit fee. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No chan es will be in e without first obtaining approval from the Mason County Fire Marshal. By: Date: IACommunity DevelopmentMIL.DING\Fire Protection System Permit Application.doc Honeywell IntelliKnight 6700 Battery Calculation SKVIGHT Secondary Power Source Requirements Standby . Secondary Alarm Current(amps) TotalDevice Type -T Qty Current Draw Qty 1 Current Draw Total 1.Control Panel 6700 Control Panel jxj 0.165000 = 0.165000 1 jxj 0.310000 1= 0.310000 2.Addressable SLC Devices SK-PHOTO(-T) 1 x 0.000300 = 0.000300 1 x 0.000300 = 0.000300 SK-PHOTO-W(-T) x 0.000 000 = x 0.000450 = SK-HEAT(-HT)(-ROR) 10 x 0.000300 = 0.003000 10 x 0.0 00300 = 0.003000 SK-HEAT-W(HT)(ROR) x 0.000200 = x 0-000450 = SK-BEAM x 0.002000 = x 0.002000 = SK-BEAM-T x 0.002000 - x 0.002000 = SK-DUCT x 0,000300 = x 0.000300 = SK-ACCLIMATE x 0.000300 = x 0.000300 = SK-CONTROL x 0.0003 55 = x 0.0063 55 = SK-MONITOR x 0.000375 = x 0.000375 = SK-MINIMON x 0.000375 = x 0.000375 - SK-PULL-SA 2 x 0.000375 = 0.000750 2 x 0.000375 - 0.000750 SK-PULL-DA x 0.000375 = x 0.000375 = SK-MONITOR-2 x 0.000750 = x 0.000750 = SK MON-10 x 0.003500 = x 0.003500 = SK-RELAY-6 x 0.001450 = x 0.001450 SK-CONTROL-6 x 0.002250 = X 0.002250 = SK-RELAY 1 x 0M0255 = 0.000255 1 x 0.000255 = 0.000255 SK-RELAYMON-2 x 0.001300 = x 0.024000 = SK-ZONE x 0.000270 = x 0.000270 = SK-ZONE-6 x 0.002000 = x 0.002000 = SK-FIRE-CO x 0.000300 jxj 0.007200 = 3.SLC Accessory Bases 6200S x 0.000300 = x 0.000300 - 6200S-LF x 0.000300 = x 0.000300 - - SR x 0.000300 = x 0.000300 ff2 B200SR-LF x 0.000300 7 x 0.000300 RTS151 x 0.000500 = x 0.000 000 - TS15i x 0,000000 = x 0.007500 RTS151KEY x 0.000006 = x 0.007500 - RA100Z ]XI 0.000000 1XI 0.010000 - 4.SLC Isolator Devices SK-ISO x 0.000450 = x 0.000450 - ISO 6 x 0.002700 = x 0.102000 = B22461 x 0,000500 = x 0.000500 - CEIVE `"' `� L SEP 12 2023 Page 1 8/23/2023 5.Auxiliary Power Draw-SLC Devices SK-CONTROL(Aux. Power) x 1 0.001700 -=T x 0.007000 = SK-CONTROL-6(Aux.Power) x 0.008000 = x 0.020000 = SK-ZONE(Aux.Power) x 0.012000 = x 0.090000 = SK-ZONE-6(Aux.Power) x 0.050000 = x 0270000 = B200S(Aux.Power) x 0.000500 = x 0.035000 = B20OS-LF(Aux.Power) x 0.000550 1 1XI 0.140000 = B200SR(Aux.Power) x 0.000500 1XI0.035000 = B200SR-LF(Aux. Power) x 0.001000 1XIQ.125000 6.Accessory Modules 5$60 x 0,02000 jxj 0.025000 = 5824 x 0.045000 = x 0.045000 = 5496 x 0.010000 = x 0.010000 = 5895XL x 0.010000 = XF 0.010000 = 6855 x 0.020000 = xj 0.025000 - 6860 x 1 0.025000 = x 0.050000 = 5865-4 x 0.035000 = x 0.145000 = 5865-3 x 0.035000 = x 0.145000 = 5880 x 1 0.035000 = x 0.200000 = 5883 x 0.000000 = x 0.220000 = SK-IP-2 x 0.093000 = x 0.136000 - SK-IP-2UD x 0.098000 = XI 0.155000 = CELL-MOD x 0.055000 = x 0.100000 = CELL-CAB-SK x 0.055000 = x 0.100000 = WSK-WGI Aux_Power x 0.040000 = x 0.040000 - SLG Power xl 0.024000 = x 0.024000 = SK-NIC xj 0.021000 =1 x 0.021000 = SK-NIC-KIT x 0.021D00 = x 0.021000 = SK-FSL x 0.079000 = x 0.079000 = SK-FML x 0.053000 = x 0.053000 SK-FFT x 0.120000 = x &230000 = 7.Miscellaneous Devices Conventional Detectors x 0.000000 = x 0.000000 = Miscellaneous Device 1 x 0.000000 = x 0.000000 Miscellaneous Device 2 x 1 0,000000 = x 0.000000 = Miscellaneous Device 3 x 0.000000 = x O.000000 = Miscellaneous Device 4 x 0.000000 = x 0.000000 = Miscellaneous Device 5 x 0.000000 7F 1XI0.000000 = 8.Notification Appliance Circuits NAC 1 0.000000 = 0.000000 = MAC 2 1 0.000000 0.000000 1- == Total Standby Load 0.169305 Total Alarm Load 0.314305 Page 2 8/23/2023 Honeywell IntelliKnight 6700 Battery Calculation S«, Note 1:You are fully responsible for verifying these calculations. �avtGKr Note 2:Use the dropdowns in the yellow cells to enter values. Calculation in Total Sheet 24 Hours Standby Load Current 1 0.16931 Amps x 24 1=1 4.063 AH 5 Minutes Alarm Load Current(Amps) 1 0.31431 Amps 0.084 1= 0.026 AH Total Current Load 4.090 AH Multiply by the Derating Factor 1.2 1= x 1.20 Total Ampere Hours Required III AH Recommended Batteries: 'AH Ratteries Battery Check The batteries can be charged by the 6700 Charger. The batteries can be housed in the 6700 Cabinet Current Draw Check Circuit#1 current is within the limitations of the circuit. Circuit#2 current is within the limitations of the circuit. 6700 Control Panel: The output current is within thepanel's limitations. Page 3 8/23/2023 Honeywell Os � IntelliKnight 6700 Circuit Detail NAC 1 Devico QTotal x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 x 0.000000 = x 0.000000 - x 0.000000 = x 1 0.000000 x 0.000000 = x 1 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = Total Standby Load 0.000000 Total Alarm Load 0.000000 NAC 2 Device Qty I Non-Alarm Draw Total Qty I Alarm Draw Total x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 - x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = x 0.000000 = Ljx 0.000000 = x 0.000000 = XI 0.000000 = x 0.000000 xI 0.000000 = x 0.000000 = Total Standby Load 0.00o000 I Total Alarm Load 0.000000 Page 4 8/23/2023 Honeywell OS> G Intellil(night 6700 EOL Voltage Drop Starting Voltage 20.4 Volts Minimum Voltage P,EOL 16 Volts Voltage Drop Warning% 10.00% Current Actual Percent Draw Wire Type Resistance Length Resistance Voltage @ EOL Drop Feet Circuit Name Amps AVVG Ohms/1000 ft. (One Way) Ohms Volts Percent NAC 1 1 0.000 #12 Solid 1 1.93 1 0 0.00 20.40 0.00% NAC 2 0.000 1#12 Solid 1 1.93 0 0.00 20.40 0.00% Resistance Table Wire Type Resitance AWG Ohms11000 ft. #10 Solid 1.21 #10 Stranded 124 #12 Solid 1.93 #12 Stranded 1.98 #14 Solid 3,07 #14 Stranded 3.14 #16 Solid 4.89 #16 Stranded 4.99 #18 Solid 7.77 #18 Stranded 7,95 I`Icte:All Desistance values are taken from Table 8 Conductor Properties of the NFPA 70 National Electrical Code.All values are for Direct Current Resistance at 75°C (167-F). Page 5 8/23/2023