HomeMy WebLinkAboutFIR2023-00032 Alarm - FIR Inspections - 10/20/2023 INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# FIR2023-00032 PROJECT ADDRESS 1716 SE Ridge Rd Shelton, WA 98584 PARCEL# 320295004003 PROJECT DESCRIPTION FIRE ALARM OWNER PADDEN JAMES & BRIEANN ADDRESS PO BOX 3389 PHONE 360-265-3306 CONTRACTOR SOUTH SOUND FIRE&SECURITY LLC ADDRESS 5207 HOLLY CT NE PHONE CONTRACTOR LICENSE SOUTHSF8220E LENDER INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments KNOX BOX VERIFICATION 1 + Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FFIR2O23-00032 FIRE ALARM RIPTION: FIRE ALARM ISSUED: 10/10/2023 1716 SE RIDGE RD SHELTON EXPIRES: 04/07/2024 PARCEL: 320295004003 APPLICANT: PADDEN JAMES&BRIEANN OWNER: PADDEN JAMES&BRIEANN PO BOX 3389 PO BOX 3389 BELFAIR,WA 98528 BELFAIR,WA 98528 360-265-3306 GENERAL CONTRACTOR'S LICENSE: SOUTH SOUND FIRE&SECURITY LLC License: SOUTHSF8220E 5207 HOLLY CT NE Expires: 09/05/2024 OLYMPIA,WA 98516 VALUATIONS: FEES: Paid Due Project Valuation (BID, 10475.03 $10,475.03 Fire Protection Permit Fee $199.37 $0.00 ESTIMATION..) Fire Protection Plan Check $129.59 $0.00 Technology Surcharge $3.99 $0.00 Total: $10,475.03 Totals : $332.95 $0.00 REQUIRED INSPECTIONS KNOX BOX VERIFICATION CONDITIONS OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Printed by:Annie Wilson on:10/10/2023 01:26 PM Page 1 of 2 V K --W- Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FIRE ALARM FIR2023-00032 Fire Marshal Comments I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: 1 1 l Contractor or Authorized Agent: Date: 6 Z Printed by:Annie Wilson on:10/10/2023 01:26 PM Page 2of2 MASON COUNTY F1R20,73_- o0 COMMUNITY SERVICES RECEIVED Building PlanningEnvironmental Health,Community Health OCT 10 2023 Mason County Fire Protection System Permit App1icatio§/1§nWej0@bW stem Incomplete applications will not be accepted Owner: .LvveS FCj&#-'1 Phone#: 3�0 Z�OS 3�v Mailing Address: Pb boJ� City: ( r State: Zip: L7Z Site Address: 9��5f-g City: — State: t-A-Zip:q -1c")Cf Parcel #: 2OM S�a?3 Legal Description: Contractor: South Sound Fire &Security,LLC Phone#: 360-918-2200 Address: 5207 Holly Ct NE City: Olympia State: WA Zip: 98516 Contractor Registration#: SOUTHSF8220E Expiration Date: 9/5/2024 Building Square Footage (existing&proposed): l" / 2nd / 3rd Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: New System: Wet Dry Modification: Standpipe: Wet Dry Fire Underground Automatic Fire Alarm: X Fire Pump Hood &Duct: Dry Chem: Wet Chem: UL certified Monitoring company: Securitas Phone#: 800-752-2490 Contractors Bid Price: 5l0,475.03 1ACommunity Dcvclopment\BUILDING\Fire Protection System Permit Application.doc Plan Submittal Requirements Your plan submittal shall include the following: 1. Plans shall be on standard 24"x 36"paper,drawn to scale with dimensions and north arrow. 2. Site and Floor plan with cross sectional and exterior elevations. 3. Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces, etc. 4. Cut sheets and/or references for all new devices. 5. Location/description of all new and existing devices. 6. Battery calculations. 7. Wiring diagrams per floor or zone overlaid on an accurate floor plan. 8. Electrical riser diagram showing all zones, circuits, devices, and end—of—line resistors. 9. Hydraulic calculations. 10. Copy of Contractors bid. 11.Underground Systems, a) NICET FPE Certification b) Underground Civil drawings c) Bedding detail d) Truss blocking/Mega Lugs detail e) Depth/Material for burial f) Pipe size and Type Fees The permit fee will be assessed based on the submitted contractor bid for the project. A plan review fee will be calculated at 65%of the permit fee. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By: Date: 10/10/2023 (:\Community Development\BUILDINGTire Protection System Permit Application.doc MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 go COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: /�/� Zf Z3" 90a2Z, ADDRESSILOCATION: /7/� SE /�iGCG FINDINGS: ✓i.�ti 6e �i-c.s ccG O v- ®/7 Z dzv v zp 7tb e4 1wt-i 12 Gal�ui`c� fv .su Z.� v Items listed above must be corrected to gain compliance. THIS IS NOT A COMPLETE INSPECTION This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. Call for re-inspection when corrections are made before proceeding with any further work. ® Make corrections, items will be checked on the next inspection. OK to Date: lv ❑ Please contact our office regarding possible Department: _ structural damage incurred by recent natural/man made"disasters.This is NOT a Inspector: .� CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 Mason County Fire Marshal 615 W. Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 41 Fire Alarm Certifica/tion/Final Test FIR =bZ3- 3Z Location: f 7i0 �, -� A'2 Contractor: Phone #: 753- Contact: Test Date: 'L If,ZO Tod CHECKLIST v Verify panel is in "Normal"condition and clear of any signals Kill Power At Electrical panel & verify dedicated circuit, red breaker& lockout �L AC Trouble/ No Power displayed? Activate device(s), verify it activates the alarm and shows correctly on the panel Check the Notification Alarm Circuit (NAC) for activation of devices. Walk building while alarm is activated under battery load. Check for all lights and sounds to be in-sync ✓ Silence Alarm \/ Activate a few other devices in different areas to verify alarm reactivates after being silenced Reset Alarm Does panel still show trouble (due to AC power)? Disconnect Signal Loop Circuit (SLC) to create/verify a trouble for each device on circuit Reconnect SLC. System should reset& only AC trouble showing Disconnect the communication line &verify communication trouble c fl$Cdfi✓/ ZA /, . Do batteries AMP/HR match plans? 2-7010 N FACP Sign on Door(s) leading to panel location? Device Test Log Notification Device Time Reset N/A Comments Water flow Inspectors test 4 Smoke detector at FACP S Tamper switch 1 Tamper switch 2 Manual pull at or - / Manual pull at t; Manual pull at Heat Detector Heat Detector Heat Detector Heat Detector Heat Detector Smoke Detector Smoke Detector C,,,7c Smoke Detector n ?� Smoke Detector Punch List/Comments: 7111/ T Z' 7✓f�f�`rG G{�%n y l�� �'/ss 1H�//�/S %7 /,o i/D� !7/ / /G�J;G�•�//h f'd i>� ��� Gz�t�h� �n✓.�„ �����srr�,Tr%� �OG��/J!'yf,r,/�:!%/J �'e=•f Passed Final Test? Yes ✓ No_ From South Sound Fire& Security, LLC aouth 5207 Holly Court Northeast ♦ ziound Olympia WA 98516 Fire & Security 253-229-2132 Quote No. 2007917 Quote For Super Select Type Installation 1716 Ridge Rd Prepared By William Hetland Shelton WA 98584 Created On 10/09/2023 Services to be completed Alarm Systems Installation of fire alarm system 'Does not include fire alarm design changes required by local AHJ —Requires monthly monitoring contract @$52 per month ""Does not include lift rental if needed to gain access Parts, labor,and fees Quantity Unit Price Tax Total Silent Knight 100-Point Addressable Fire 1 $1,791.82 $152.30 $1,944.12 Alarm Control Panel Silent Knight Photoelectric Smoke Detector 4 $119.83 $40.74 $520.06 Silent Knight Pull Station 1 $170.10 $14.46 $184.56 Starlink Cellular Fire Alarm Communicator 1 $508.98 $43.26 $552.24 System Sensor Wall Horn Strobes 2 $94.83 $16.12 $205.78 System Sensor Exterior Horn Strobe 1 $125.71 $10.69 $136.40 Fire Alarm Permits and Submittals 1 $1,005.00 $85.43 $1,090.43 Fire Alarm Design/CAD Drawings 1 $915.00 $77.78 $992.78 Miscellaneous Supplies-Fire wire, boxes, 1 $201.82 $17.15 $218.97 drive rings,tie wraps, paint, etc. Installation and Programming 1 $4,215.00 $358.28 $4,573.28 Monthly fire alarm monitoring 1 $52.00 $4.42 $56.42 SUBTOTAL $9,654.41 TAX @ 8.5% $820.62 GRAND TOTAL $10,475.03 By my signature below, I authorize work to begin and agree to pay the Grand Total. Name: Date: Signature: Fioneywell FarenhytT"' Series ,.. CONNECTED L-Series Indoor Horns, Strobes, and Horn Strobes The L-Series audible visible notification products offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings,standard and compact devices,and plain,FIRE,and FUEGO-printed devices,System R Gr Sensor L-Series can meet virtually any application requirement. E E The L-Series line of wall-mount horns,strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • , , �,� To further simplify installation and protect devices from construction damage,the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring,so installers can test wiring continuity before the device is installed. INDOOR SELECTABLE-OUTPUT HORNS, STROBES,AND HORN STROBES FOR WALL Installers can also easily adapt devices to a suit a wide range APPLICATIONS of application requirements using field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. FEATURES & BENEFITS • Updated Modern • Meets DOD • Automatic selection of Mounting plate • Compatible with Aesthetics specification 12-or 24-volt shorting spring checks System Sensor • Offers small profile requirements operation at 15 and 30 wiring continuity synchronization devices for horns and • Features a plug-in candela before device protocol horn strobes design with minimal • Uses field-selectable installation • Listed for wall • Color lens intrusion into the back candela settings on Supports electrically mounting only attachments for use box wall units:15,30,75, compatible with with clear lens wall or • Horn rated at 88+dBA 95,110,135,185 existing SpectrAlert ceiling strobe at 16 volts • Mounting plate for all and SpectAlert • Designed with • Supports rotary switch standard and all Advance devices tamper-resistant for horn tone and two compact wall units construction volume selections IP L-SERIES SPECIFICATIONS ARCHITECT/ENGINEER SPECIFICATIONS GENERAL L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box, 4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 1 7/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non- coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. STROBE The strobe shall be a System Sensor L-Series Model_______listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and complywith the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model_______listed to UL 1971 and UL 464 and shalt be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and complywith the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MD L3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PHYSICAL AGENCY LISTINGS AND APPROVALS Wall-Mount Dimensions(including lens):5.6" L x 4.7"W x 1.25" D UL:Listed (143 mm L x 119 mm W x 32 mm D) FM:Approved Compact Wall-Mount Dimensions(including lens):5.26"L x 3.46"W CSFM:Listed x1.93"D(133 mm Lx88mmWx49mm D) Horn Dimensions:5.6-L x 4.7"W x 1.25` D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions:5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) ELECTRICAL SPECIFICATIONS Strobe Flash Rate:1 flash per second Nominal Voltage Regulated:12VDC or regulated 24DC/FWR1 Operating Voltage Rangez:8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3)Sync Module:8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge:12 to 18 AWG ENVIRONMENTAL Standard Operating Temperature:32°F to 120°F(0°C to 49°C) Humidity Range:10 to 93%non-condensing Notes: 1.Full Wave Rectifi ed(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. IF UL MAX HORN CURRENT DRAW(mA RMS) UL MAX STROBE CURRENT DRAW(mA RMS) SOUND PATTERN DB 8-17.5V 16-33V CANDELA 8-17.5V 16-33V DC DC FWR DC DC FWR Temporal High 39 44 54 CANDELA 15 88 43 60 Temporal Low 28 32 54 RANGE 30 143 63 83 Non-Temporal High 43 47 54 75 N/A 107 136 Non-Temporal Low 29 32 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 1 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX CURRENT DRAW(mA RMS),2-WIRE HORN STROBE,CANDELA RANGE(15-115 CD) 8-17.5V 16-33V DCINPUT 15CD 30CD 15CD 30CD 75CD 95CD 110CD 135CD 185CD EM Temp Hi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.iKTemp Hi 93 156 53 73 119 140 164 190 242 3.1KTemp Low 91 154 45 66 112 133 160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1K Cont Low 93 156 152 172 119 138 162 192 242 16VFWR SWITCH POSITION 15CD 3000 75CD 95CD 110CD 135CD 185CD EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1KTemp Hi 81 105 155 177 196 234 284 3.1KTemp Low 68 90 145 166 186 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1K Cont Low 77 102 156 177 199 234 291 HORN AND HORN STROBE OUTPUT(DBA) 8-17.5V 16-33V FWR SWITCH POSITION SOUND PATTERN DB DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 L-SERIES DIMENSIONS 3.46 1.91 3.46 For a complete listingo of all compliance approvals and - 125 � � 1.25 certifications,please visit www.farenhyt.com. Microsoft,Windows,and °o a°oho°�oo°a° the Windows Logo are 5.27 5.27 0000000000o registered trademarks 0°0°0°o°i111 or trademarks of Microsoft Corporation. stifle Honeywell"and o System Sensor'are registered trademark Compact Strobe!Horn Strobe compact Horn of and Farenhyt-is a trademark of Honeywell International,Inc. This document is not intended to be used for = 4.70 J installation purposes.We try to keep our product 1.91 4.70 - - t� information up-to 1.25 date and accurate.We 1.25 cannot cover all specific applications or anticipate all requirements.All specifications are subject 5.67 5.67 to change without notice. For Technical Support,Please call i t 800-446-6444. Strobe!Horn Strobe Horn L-SERIES ORDERING INFORMATION WALL HORN STROBES HORNS P2RL:2-Wire,Horn Strobe,Red HRL:Horn,Red P2WL:2-Wire,Horn Strobe,White HWL:Horn,White P2GRL:2-Wire,Compact Horn Strobe,Red HGRL:Compact Horn,Red P2GWL:2-Wire,Compact Horn Strobe,White HGWL:Compact Horn,White P2RL-P:2-Wire,Horn Strobe,Red,Plain P2WL-P:2-Wire,Horn Strobe,White,Plain ACCESSORIES P2RL-SP:2-Wire,Horn Strobe,Red,FUEGO TR-2:Universal Wall Trim Ring Red P2WL-SP:2-Wire,Horn Strobe,White,FUEGO TR-2W:Universal Wall Trim Ring,wht SBBRL:Wall Surface Mount Back Box,Red WALL STROBES SBBWL:Wall Surface Mount Back Box,White SRL:Strobe,Red SBBGRL:Compact Wall Surface Mount Back Box, SWL:Strobe,White Red SGRL:Compact Strobe,Red SBBGWL:Compact Wall Surface Mount Back Box, SGWL:Compact Strobe,White White SRL-P:Strobe,Red,Plain Note: SWL-P:Strobe,White,Plain All-P models having a plain housing(no"FIRE SRL-SP:Strobe,Red,FUEGO marking on cover. SWL-CLR-ALERT:Strobe,White,ALERT All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT'marking on cover For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security&Fire 12 Clintonville Road Northford,CT 06472 Doc 18Hon 1Rev IO2/18 Honeywell 800-328-0103 ©2018 Honeywell International Inc. MK- PHOTO -W Clo Addressable Photoelectric Smoke Detectors The Silent Knight' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. - The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics,and are direct replacements for the SK-PHOTO Series detectors.A new modern,sleek,contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level.Dual electronic thermistors add 135°F(5710 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DN R Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • Integral communications and built-in • Expanded color options • Sleek and stylish contemporary design device-type identification • SEMS screws for wiring of the separate base • Stable communication technique with • Remote test feature from the panel • Optional remote,single-gang LED noise immunity • Built-in functional test switch activated by accessory • Addressable by device external magnet • Optional sounder,relay,and isolator bases • Rotary,decimal addressing(Refer to the • Walk test with address d351634isplay(an Silent Knight panel manuals for device address of 121 will blink the detector LED capacity) 12-(pause)-1) • Two-wire SLC connection • Low standby current • LEDs blink every time the unit is polled • Built-in tamper-resistant feature • 36011-field viewing angle of the visual alarm • Designed for direct-surface or electrical- indicators(two bi-color LEDs);LEDs blink box mounting green in Normal condition and turn on • Seated against back pressure Honeywell steady red in Alarm • Plugs into separate base for ease of installation and maintenance ®SILENT' KNIGHT INSTALLATION B224BI-IV:Ivory,plug-in System Sensor isolator detector basll The SK-PHOTO-W Series plug-in intelligentthermaldetectors use a ACCESSORIES separate base to simplify installation,service,and maintenance. Installation instructions are shipped with each detector. TR300:White,replacement flange for B210LP or B300-6 bases Mount base(all base types)on an electrical backbox which is at TR300-IV:Ivory,replacement flange for B21OLP or B300-6 bases least 1.5'(3.81 cm)deep.For a chart of compatible junction boxes, RA10OZ(A):Remote 3-32 VDC LED annunciator,mounts to a U.S. see SK-61045. single-gang electrical box,for use with B501 and B300-6 bases Note:Because of the inherent supervision provided by the SLCloop, only end-of-line resistors are not required.Wiring"T-taps"or branches M02-04-00:Test magnet are permitted for Class"B"wiring. M02-09-00:Test magnet with telescoping handle Note:When using relay or sounder bases,consult the SK-ISO CK300:White,detector color kit,pack of 10 installation sheet 156-3627 for device limitations between isolator CK300-IV:Ivory,detector color kit,pack of 10 modules and isolator bases. CK300-BL:Black,detector color kit,pack of 10 OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent)on the Signaling Line Circuit(SLC).It responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the panel(or a local magnet test),it stimulates its electronics and reports an alarm.It blinks its LEDs when polled and turns the LEDs on when commanded by the panel.The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note:"-IV"suffix indicates ivory color. SK-PHOTO-W:White,low-profile photoelectric sensor SK-PHOTO-T-W:White,same as SK-PHOTO-W but includes a built-in 135°F(57°C)fixed-temperature thermal device SK-PHOTO-R-W:White,low-profile intelligent photoelectric sensor, remote test capable,for use with DNR/DNRW B300-6:White,standard flanged low-profile mounting base B300-6-BP:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged low-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL:Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base B501-WHITE-BP:Bulk pack of B501-WHITE,contains 10 B20OS-WH:White,Intelligent,programmable sounder base B200S-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B20OS-LF-WH:White,Low Frequency Intelligent,programmable sounder base B20OS-LF-IV:Ivory,Low Frequency Intelligent,programmable sounderbase B200SR-LF-WH:White,Low Frequency Intelligent sounder base for retrofit applications B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for retrofit applications B224RB-WH:White,plug-in System Sensor®relay base B224RB-IV:Ivory,plug-in System Sensor relay base B224BI-WH:White,plug-in System Sensor isolator detector base Page 2 of 3—351634:C•5/28/2020 K-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL DETECTOR SPACING AND Sensitivity: APPLICATIONS ' 0 o Silent Knight recommends spacing - registered trademarks -UL Applications:0.5/o to 4.0/o per foot 9 P 9 obscuration. detectors in compliance with NFPA 72.In HoneywellInternational, low airflow applications with smooth ceiling, intended _ -ULC Applications:0.5%to 3.5%per foot space detectors 30 feet(9.1m).For specific documentThis ' ' ' obscuration information regarding detector spacing, used for installationpurposes. Size:2.0'(51mm)high;base determines placement,and special applications referto try to keep our product inf• • diameter NFPA 72.A System Smoke Detector up-to-date and accurate. cannot Application Guide,document SPAG91, coverall •-cific applications or -B300-6:6.1'(15.6 cm)diameter available at www.systemsensor.com.-B501:4'(10.2 cm)diameter anticipate all requirements. •- - are • - change For a complete list of detector bases,see AGENCY LISTINGS AND APPROVALS SK-61045. notice.without Shipping weight:3.4 oz.(95 g) These listings and approvals apply to the Country origin: modules specified in this document.In some Operating temperature range: cases,certain modules or applications may • SK-PHOTO-W:32'Fto122'F(0°Ct050°C) not be listed by certain approval agencies,or • SK-PHOTO-T-W:32°F to 100°F(0°C to listing may be in process.Consult factory for 38°C) latest listing status. • SK-PHOTO-R-W installed in a DNR/DNRW: • UL Listed:S6173 -4°F to 158°F(-20°C to 70'C) • FM Approved • CSFM:7272-0559:0512 UL/ULC Listed Velocity Range:0-4000 ft/ min.(1219.2 m/min.),suitable for installation in ducts Relative humidity:10%—93%non- condensing Thermal ratings:fixed-temperature set point 135°F(5710,rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communication every 5 seconds with LED enabled) Max current:4.5 mA C 24 VDC("ON") Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203.484.7161 351634 1 C 1 05/20 SILENT www.sitentknight.com @2020 Honeywell International Inc. ®KNIGHT n n O N N O N t\D O f0 SPLICE PLATE & BOLT TABLE MEMBER TABLE QtY Mark Web Depth Web Plate Outside Flange Inside Flange Mark To Bat Int Type Dia Length Width Thick Length Start nd Thick Length W x Thk x Len th W x Thk x Length RF1-1 12.0 35.0 0.164 287.0 5 x 1 4 x 327.6 5 x 1 4 x 180.6 SP-1 4 4 0 A325 0.750 3.00 6" 5/8� 3'-11" 35.0/35.0 0.220 43.6 5 x 5/16� x 43.1 5 x 5/16" x 107.3 SP-2 4 4 0 A325 0.625 2.25 6" 1 2 2'-2 1 8" RF1-2 40.0/18.0 0.164 121.4 6 x 5/16 x 118.0 6 x 1/4' x 123.3 18.0 20.0 0.150 198.1 6 x 1/4" x 198.1 6 x 1/4" x 196.4 EB-3 W8x 8 0 C m O �22 385.25� 10 3/4�� �10 3/4• 385.25' a c //��jj r g 1/4* 1'_4• 1,-4. 5 1/4•"IFf d` m' ZC/- G 60 4'-3" 6 p 4•-3- 3'-3 1/4� •-3 1/4• 12 Q7� 1 12 $ o 1) FB 3vpF 2) a3 U5S _ Go FBC 2'-o 1/16• o 2•_0 1/16" FB (2) _ _ FBC�) strut — � o - RFt-2 al RF1-2 _ v Q ' �T I I = B se V g�� > I a a I 3 ± rn N m ; R I I I I to I I m �I I� � InCo Go I I I I o N I ; N I I I N N IT o z n o i— z O o w z Q 8, r 2'-11 9/16" 52'-B 7/8• 2'-11 9/16- , 8, 0 3: (D CLEAR + - Q Z ZU M Wa0 � � CO f I— _ � I.LIRt 2 W W w Z m A C RIGID FRAME ELEVATION: FRAME LINE 2 3 GENERAL SF 11.. 0 INDICATESFLANGE BRACING LOCATIONS. (1) = ONE SIDE; '(2) TWO SIDES. in 2. IF FLANGE BRACING IS REQUIRED ON BOTH SIDES OF AN EXPANDABLE RIGID FRAME, THE OPPOSITE SIDE FLANGE BRACES WILL HAVE TO BE INSTALLED AT THE TIME OF FUTURE EXPANSION. THESE FLANGE BRACES HAVE BEEN PROVIDED, AS REQUIRED, ' FOR THIS FUTURE CONDITION. 3. RIGID FRAMES SHALL HAVE 50% OF THEIR BOLTS INSTALLED AND TIGHTENED ON BOTH SIDES OF THE WEB ADJACENT TO EACH FLANGE BEFORE THE HOISTING EQUIPMENT IS g- �I ii, w RELEASED. 11—N[ it s og ll m 4. INTERIOR COLUMN METAL TAG IS ORIENTED TOWARD THE LOW EAVE OF THE BUILDING. € � 'll O 4 it W M1 IF13 O N N N O\i �O N M O to EXTENSION CANOPY BOLTS ROOF PLAN MARK I QUAN TYPE DIA LENGTH 1 4 EB-2 4 A325 5 8 2 1 4 2'-0' 60'-0.0ur-T0-0ur of STEEL2._0. EB-3 4 A325 5 8" 2 1 4" MEMBER TABLE 2 3 ROOF PLAN 20'-0• 20 0• 20'-0• MARK PART LENGTH EB-1 J08C060 54.813 EB-2 W808 49.563 EB-3 W80 8 49.563 2 1 -1 1/Y 'I 1'-1 1/2• C � EB-4 J08C060 54.813 0 P-1 08Z060 282.750 " N EB-4 E -2 _ E -3 E -3 _ E -2 E -1 P-2 08ZO60 278.000 P-3 08Z060 282.750 o g` T E-1 08E060 214.500 m A WI IW E-2 08EO60 228.000 L /Z— E-3 08C060 263.000 E-4 08CO60 238.500 Ij E-5 08E060 25.500 ST-1 W08SB075 234.750 P_1 P-2 P_3(Type I CB-2 RD05- 283.000 CB-3 RD05- 281,000 I CB-4 RD08- 294.000 CB-5 RD05- 299.000 Alm I I CONNECTION PLATES o I I ROOF PLAN $ gj$ y ER-1 F1-2 RF1-2 ER-1 DID MARK PART ii n I I 1 EEC01 351 I I I xi I I I C-4 wl P- yP _I yP -1 yP Iw I I z O I I v I I � M I z ER-1 RF1-2 RF1-2 ER-1 I O o () I z g Z Q (D - ROOF FRAMING PLAN a o g co co I GENERAL NOTES U)w Lid J p w p F- -I — 1. PLACE TAGGED END OF RAFTERS TOWARDS THE LOW EAVE. w 2 o m LU c) BII I H-2 -4 / Q � � Z 2. STD. ROD CABLE SIZES PER PART PREFIX ARE: a � L>� Y o w - ROD CABLE- -1 1-1 - - -1 RD05- = 5/8• ROD CA02- = 1/4• CABLEo - 8" CABLE -4 - RD07- = 7/8• ROD CA04- = 3/2' CABLEELB-I EB-3 LEB-3E / / r. iv RD08- = 1' ROD � PURLLIINN xtL i +AP r L2}�,r xx RD09- = 1 1/8" ROD RD10- = 1 1/4' ROD �p / ROOF FRAMING PLAN 3. PURLIN AND EAVE STRUT CONNECTIONS UTILIZE BOTH c�SSl Esf' A307 AND A325 BOLTS. REFER TO THE DETAILS �>► �� ♦� FOR SPECIFIC USAGE REQUIREMENTS. 4. THIS DRAWING IS NOT TO SCALE. $ s N sag �� �� i$. 9 � x 1,Pv-1 -l o 1s16 .titi w � sURA SQL INITIATING DEVICES 72-105 17.7.3.2.2* To minimize dust contamination,smoke detectors, (b) For beam depths greater than or equal to where installed under raised floors, shall be mounted only in 10 percent of the ceiling height (0.1 F), spacing an orientation for which they have been listed. shall be in accordance with 17.7.3.2.4.2(2). (4)* For corridors 15 ft (4.6 m) in width or less having ceiling 17.7.3.2.3 On smooth ceilings, spacing for spot-type smoke beams or solid joists perpendicular to the corridor detectors shall be in accordance with 17.7.3.2.3.1 through length,the following shall apply: 17.7.3.2.3.4. (a) Smooth ceiling spacing shall be permitted. 17.7.3.2.3.1* In the absence of specific performance-based (b) Location of spot-type smoke detectors shall be design criteria,one of the following requirements shall apply: permitted on ceilings, sidewalls, or the bottom of (1) The distance between smoke detectors shall not exceed a beams or solid* * ts' s nominal spacing of 30 R (9.1 in) and there shall be detec- (5) For rooms of 900 ft (84 m ) or less, the following shall ✓ tors within a distance of one-half the nominal spacing, measured at right angles from all walls or partitions (a) Use of smooth ceiling spacing shall be permitted. extending upward to within the top 15 percent of the ceil- (b) Location of spot-type smoke detectors shall be ing height. permitted on ceilings or on the bottom of beams. (2)* All points on the ceiling shall have a detector within a distance equal to or less than 0.7 times the nominal 30 ft 17.7.3.2.4.3* For sloping ceilings with beams running parallel (9.1 m) spacing(0.7S). (7-1' ) up slope,the following shall apply: 17.7.3.2.3.2 In all cases,the manufacturer's published instruc- (1) Spot-type detector(s) shall be located on the ceiling dons shall be followed. within beam pocket(s). (2) The ceiling height shall be taken as the average height 17.7.3.2.3.3 Other spacing shall be permitted to be used over slope. depending on ceiling height,different conditions,or response (3) Spacing shall be measured along a horizontal projection requirements. of the ceiling. (4) Smooth ceiling spacing shall be permitted within beam 17.7.3.2.3.4 For the detection of flaming fires, the guidelines pocket(s) parallel to the beams. in Annex B shall be permitted to be used. — (5) For beam depths less than or equal to 10 percent of the 17.7.3.2.4* For solid joist and beam construction,spacing for ceiling height(0.1 Fn,spot-type detectors shall be located spot-type smoke detectors shall be in accordance with with smooth ceiling spacing perpendicular to the beams. 17.7.3.2.4.1 through 17.7.3.2.4.6. (6) For beam depths greater than 10 percent of the ceiling height (0.1 I), the following shall apply for spacing 17.7.3.2.4.1 Solid joists shall be considered equivalent to perpendicular to the beams: beams for smoke detector spacing guidelines. (a) For beam spacing greater than or equal to 17.7.3.2.4.2 For level ceilings,the following shall apply: 40 percent of the ceiling height (0.4 F), spot-type (1) For ceilings with beam depths of less than 10 percent of detectors shall be located in each beam pocket. the ceiling height(0.1 F),the following shall apply: (b) For beam spacing less than 40 percent of the ceiling height (0.4 I), spot-type detectors shall not be (a) Smooth ceiling spacing shall be permitted. required in every beam pocket but shall be spaced (b) Spot-type smoke detectors shall be permitted to be not greater than 50 percent of smooth ceiling spac- located on ceilings or on the bottom of beams. ing. (2) For ceilings with beam depths equal to or greater than �N 10 percent of the ceiling height (0.1 F), the following 17.7.3.2.4.4* For sloping ceilings with beams running perpen- shall apply: dicular across slope,the following shall apply: (a) Where beam spacing is equal to or greater than (1) Spot-type detector(s)shall be located at the bottom of the 40 percent of the ceiling height (0.4 I), spot-type beams. detectors shall be located on the ceiling in each (2) The ceiling height shall be taken as the average height beam pocket. over slope. (b) Where beam spacing is less than 40 percent of the (3) Spacing shall be measured along a horizontal projection ceiling height(0.4 H),the following shall be permit of the ceiling. ted for spot detectors: (4) Smooth ceiling spacing shall be permitted within beam pocket(s). i. Smooth ceiling_spacing in the direction paral- (5) For beam depths less than or equal to 10 percent of the lel to the beams and at one-half smooth ceil- ceiling height(0.1 I),spot-type detectors shall be located ing spacing in the direction perpendicular to with smooth ceiling spacing. the beams (6) For beam depths greater than 1Q percent of the ceiling ii. Location of detectors either on the ceiling or height (0.1 H), spot-type detectors shall not be required on the bottom of the beams to be located closer than (0.4 H) and shall not exceed (3)* For beam pockets formed by intersecting beams, includ- 50 percent of smooth ceiling spacing. ing waffle or pan-type ceilings,the following shall apply: (a) For beam depths less than 10 percent of the ceiling 17.7.3.2.4.5* For sloped ceilings with beam pockets formed by height (0.1 M,spacing shall be in accordance with intersecting beams,the following shall apply. 17.7.3.2.4.2(1). (1) Spot-type detector(s) shall be located at the bottom of the beams. 5 text=Revisions. W=Text deletions and figure/table revisions. •=Section deletions. FN=New material. 2019 Edition t i