Loading...
HomeMy WebLinkAboutFIR2022-00003 Alarm Test - FIR Inspections - 1/31/2024 Mason County Fire Marshal 615 W. Alder St. Shelton WA 98584 Phone: 360-427-9670 x 309 Fire Alarm Certification/Final Test FIR Location: Z/610 Contractor: �z.%A /114"-"qS Phone #: Contact: Test Date: 12,31 ?% CHECKLIST Verify panel is in "Normal" condition and clear of any signals ✓ Kill Power At Electrical panel &verify dedicated circuit, red breaker & lockout ✓ AC Trouble/ No Power displayed? ✓ Activate device(s), verify it activates the alarm and shows correctly on the panel Check the Notification Alarm Circuit (NAC) for activation of devices. Walk building while alarm is activated under battery load. Check for all lights and sounds to be in-sync ✓ Silence Alarm Activate a few other devices in different areas to verify alarm reactivates after being silenced Reset Alarm ✓ Does panel still show trouble (due to AC power)? Disconnect Signal Loop Circuit (SLC) to create/verify a trouble for each device on circuit vl Reconnect SLC. System should reset& only AC trouble showing Disconnect the communication line & verify communication trouble ✓ Do batteries AMP/HR match plans? FACP Sign on Door(s) leading to panel location? Device Test Log Notification Device Time Comments Water flow Inspectors test , L?,�r �.24 '3 7✓ Smoke detector at FACP S ✓ Tamper switch 1 4,;:frA"Sc/- 93� J Tamper switch 2 Manual pull at �- - y ✓ Manual pull at Manual pull at Heat Detector f / (7 .7 ✓ Heat Detector r����o• , �/ �1f Heat Detector y l cv i?Q„y Heat Detector Heat Detector Smoke Detector Smoke Detector Smoke Detector c� tz :J.� ✓ 64/ /GJ SGtr C✓i� %�/yS C n r/I�� / i ii QQ N //IPCCU � nn Punch List/Comments: (�/� �Sl�l✓��� d�ti�✓i�ti�, rz 4nGl lia/QM."Cio/GLt/lf-fOlnl.�//G yIjjfiiaiCib� vtll//n /�</fG+�G�%'LY�/,GnC O�� O<ckis- / /74w1 -. . /4/2 Ce/�lY /Sffit%G� o��� isles /GcEl/Y WO# 6002 Viking Automatic Sprinkler Company 3434 First Avenue South Seattle, WA 98134 NFPA 25 Testing 206 622 4656 of 2 DRY SYSTEMS SPRINKLER SYSTEM 5 YEAR TEST - DRY P1 WET ❑ DRY STANDPIPE ❑ Occupancy Address: 21 W SANDERSON WAY Occupancy Name: PORT OF SHELTON-NEW BLDG 1 Responsible Person First& Last Name: NED WILSON Phone Number: 3604906448 Responsible Person Address, City,State,Zip. SHELTON, WA.98584 Responsible Party E-M Mail il Address NEDW@PORTOFSHELTON.COM Technician's Name:TRACY BARGE Certification No. 1962-1208-EG Date of Test: 11-5-2020 Test Frequency: 5 Year Riser Valve Make: #1 DRY 6"VIKIVG-D1 1975 Riser Valve Model: #2 DRY VIKING-F1 2004 System Identification No. 2 DRY SYSTEMS System Location: BUILDING#1 DEFICIENCIES FOUND? Yes O No El List items that were not corrected at the time of the confidence test. Use the Deficiencies section or attach itemized sheet REPAIRS: All deficiencies have been corrected 0 Corrected By: Date: This certifies that this fire and life safety system has been properly tested in accordance with NFPA Standards. The discrepancies found are noted in the report and have been reported to the building Owner/Manager for corrective action. Signature of Technician TRACY BARGE Phone #: (206) 622-4656 Name of Testing Company: Viking Automatic Sprinkler Company— Seattle Washington Building Representative (signature) Date 11-5-2020 Print Name and Title Direct Phone # Email: Building Rep unavailable 7 Building Rep declined to sign report 0 Sprinklers NFPA 25 Page 1 of 3 WO# 6002 SPRINKLER HEADS 2 DRY SYSTEMS 1. The standard sprinkler heads are less than 50 years old or within a prescribed testing period. If"No"have the heads sample tested or replaced per 2008 NFPA 25 and at the prescribed Yes V( No❑ intervals thereafter. Due date for sample testing: 2025 2. The Quick Response sprinkler heads are less than 20 years old or within a prescribed testing period. If"No"have the heads sample tested or replaced per 2008 NFPA 25 and at N/A Yes ❑ No O the prescribed intervals thereafter. Due date for sample testing. 3. The dry type sprinkler heads are less than 10 years old or within a prescribed testing period. If"No"have the heads sample tested or replaced per 2008 NFPA 25 and at N/A rV Yes ❑ No❑ the prescribed intervals thereafter. Due date for sample testing: GAUGES The maintenance on the system gauges is up-to-date. Due date for the next comparison test: 2025 Note:The system gauges are to be compared with a calibrated gauge every five(5) years. If a gauge is not within+/-3%of the calibrated gauge it must be replaced or Yes Cr No❑ recalibrated.This check should be done for multiple floors at static oressure using one calibrated gauge and hydraulic calculations. OBSTRUCTION (INVESTIGATION 1. The 5-year obstruction investigation of Fire Department Connection(FDC)piping is up-to- date in accordance with 2008 NFPA 25 Chap.14.(off.1012112012) Yes er No❑ Date for next FDC obstruction investigation 2025 2. The 5-year obstruction exam for the FDC(s)included testing and operation of the check Yes P No O valve. 3. The 5-year Obstruction Examination of the sprinkler piping is up-to-date in accordance with 2008 NFPA 25 Chap. 14.(eff.1012112012) Yes tW No ❑ Date for next Piping Obstruction Examination 2025 DRY STANDPIPE 1. Standpipe was hydrostatically tested at not less than 200 psi or 50 psi in access of maximum pressure where maximum pressure Is In excess of 150 N/A or Yes O No❑ psi. 2. The standpipe Fire Department Connection(s)(FDC)is clear of bushes, N/A ❑ Yes t( No❑ guards,or other debris and is visible from the street 3. All FDCs and hose valves have protective plugs or caps. N/A ❑ Yes Q' No❑ 4. If a plug or cover was missing from a FDC the piping was inspected N/A ❑ Yes Q' No❑ for debris. (this is required) 5. All caps and plugs have at least 12"clearance for operating wrenches. N/A ❑ Yes Gr No❑ 6. All swivels turn freely. N/A ❑ Yes tr No❑ FINAL CHECKS 1. The Fire Alarm was removed from test mode and/or other precautionary measures were removed to restore fire alarm system to normal N/A 6' Yes ❑ No❑ operation(includes removal of protective coverings). 2. The system was left in service. Yes a No O If"No",why 3. The confidence test report was given to the owner and a current status tag was posted. Yes gr No❑ 4. The confidence test report was sent to the fire marshal's office. Yes 9' No❑ Deficiencies Sprinklers NFPA 25 Page 2 of 3 This is a Federal Building O WO#6002 2 DRY SYSTEMS Deficiencies Resolved Location Deficiency. _ Recommended Resolution: SFC and/or 2008 NFPA 25 reference: Resolved Location: Deficiency: Recommended Resolution: SFC andlor 2008 NFPA 25 reference: Resolved Location. Deficiency Recommended Resolution SFC andlor 2008 NFPA 25 reference: Resolveo — Location: Deficiency: Recommended Resolution: SFC andlor 2008 NFPA 25 reference: Resolved Location: Deficiency Recommended Resolution. SFC andlor 2008 NFPA 25 reference: Sprinklers—Dry 2012 ver. 1.1 Page 4 of 4