HomeMy WebLinkAboutBLD2022-00996 Addition, Remodel - BLD Inspections - 1/21/2025 INSPECTION CARD
Mason County
615 W. Alder St.
Building 8, Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
PERMIT# BLD2022-00996 PROJECT ADDRESS 112 SE EAGLES NEST DR SHELTON, WA 98584
PARCEL# 319227590042 PROJECT DESCRIPTION ADDITION: GARAGE, MUSIC/EXERCISE ROOM, OFFICE,
CLOSET&UNHEATED ATTIC
OWNER MCCLELLAND CRAIG &KAMILLA ADDRESS 110 SE EAGLES NEST OR PHONE 360.427.7116
CONTRACTOR ADDRESS PHONE
CONTRACTOR LICENSE LENDER
INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments
Setback Inspection Shearwail Inspection
Footing Inspection Framing Inspection
Foundation Wall-Pre-Pour Mechanical Inspection
Slab Insulation Insulation Inspection
Retaining Wall Inspection BLD-Final Inspection
t
1
pL u cc-Y,c;--Cx-'7762
tics Etgfey M�z.F �-
!�f cG Je(�.r-gel
[? UT3E~i s �
r�crittt I��
Dale
DY
PROPANE TANKS
a f OTHER
DRYWALL r_ By
ET
k��- k c zac e Wo
Data ay I
n-- Sy 5-Y
Fire sepe.ateoa F I N AL INS
BY Data
sr tr:e �z,
Pass or Pe w =In
T - Fa
�I I
3Z -27 J aD '5e-r- A#-
s 1 ssl Z3 PEID
I
t>r',e 3 kI I 'I-ZrZ3--------------- �;jq�21 �V �j
I� �
FAIL
l
MINA I atc, I I t2-30)q J Cd
. I
MASON COUNTY INSPECTION RESULTS Pagel
Department of Community Development
COMMUNITY DEVELOPMENT 615 W Alder St, Shelton, WA 98584
Pe nit Assistance tenter,Sudd;,,g,Plarimr,g (360)427-9670 ext. 352
Application# BLD2022-00996 Application Type ADDITION OR REMODEL- Owner MCCLELLAND CRAIG &
RESIDENTIAL KAMILLA
Parcel # 319227590042 Site Address 112 SE EAGLES NEST DR SHELTON, WA
98584
Inspector Inspection Type Date Status Comments
12-31-24 DED
Dave Dobson BLD-FINAL INSPECTION 12/31/2024 TEMP-OCC 1)Building Air leakage test required (3.OACH per chosen energy credits)
2)L&I Final electrical inspection required
all
MASON COUNTY 360427-9670 Shelton ext.352
' 360-275-4467 Belfair ext.352
COMMUNITY SERVICES 360-482-5269 Elma ext.352
Building,Planning,Environmental Health,Community Health
61.5 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us
CORRECTIONANSPECTION REPORT
PERMIT/CASE NUMBER: 3GD 20zZ— cv jn4
ADDRESSILOCATION. //4—rS-e - 'le,.S' Ak -�- Z7V— --4/4i7
INDINGS•
ser.J 3 c3 c�7
s7c3 Ka dy�
Items listed above must be corrected to izain compliance.
❑ THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
,,Call for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to
Date: Z—Z (—23 ❑ Please contact our office regarding possible
Department: z3L fj structural damage incurred by recent
Inspector: PdA6c 2— "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
a
MASON COUNTY 360-427-9670 Shelton ext.352
360-275-4467 Belfair ext.352
COMMUNITY SERVICES 360-482-5269 Elms ext.352
Building,Planning,Environmental Health,Community Health
615 W.Alder St.Bldg.8 - Shelton,WA 98%4 WWW.masoncountywa.gov
CORRECTIONANSPECTION REPORT
PERMIT/CASE NUMBER: &,])?oa.�-17Qq�t
ADDRESS/LOCATION: 1/0 Je G.4�6LES JEST Z7R
r
FINDINGS:
PR�r�Z sc� 14y
Items listed above must be corrected to gain compliance.
[] TMS IS NOT A COMPLETE INSPECTION
This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call for re-inspection when corrections are made before proceeding with any further work.
Q Make corrections, items will be checked on the next inspection.
[] OK to 2
Date: '. '�3-� %' ❑ Please contact our office regarding possible
Department: structural damage incurred by recent
Inspector:} "natural/man made'disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY 360427-9670 Shelton ext.352
36 Be ext.352
COMMUNITY SERVICES 360482-5269 Elma ext.352
Building,Planning,Environmental Health,Community Health
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTIONANSPECTION REPORT
PERMIT/CASE NUMBER: $LD-�20a2— 00"<
ADDRESS/LOCATION: 112 S6' LGAC J S' IJ ET "" A fZ
FINDINGS:
:S-r PS nQuirab A-r -ror rt&w 3 uc-v-)-ovjoq
ws.r w'-41 A) Oa E F
ioi� ors`. , a.,o( avg;141k_
-- no cccta 4 upper k a,of ro+ g4 onSj .. or q-4' A*-
Items listed above must be corrected to gain compliance.
IS THIS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call for re-inspection when corrections are made before proceeding with any further work.
Make corrections, items will be checked on the next inspection.
❑ OK to
Date: 10-1 0-23 ❑ Please contact our office regarding possible
Department: -8LD structural damage incurred by recent
Inspector: } "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
GOMASON COUNTY 360-427-9670 Shelton ext.352
COMMUNITY SERVICES 36 60-482-52 Belfairext.352
360-482-5269 Elma ext.352
Building,Planning,Environmental Health,Community Health
615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTIONANSPECTION REPORT
PERMIT/CASE NUMBER: Z-
ADDRESS/LOCATION:
FINDINGS•
OICA
�!(-
U
Items listed above must be corrected to lain compliance.
COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
Call foe-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to
Date: �—�� — � ❑ Please contact our office regarding possible
Department: — structural damage incurred by recent
Inspector: "natural/man made"disasters.This is NOT a
CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
MASON COUNTY 360427-9670 Shelton ext.352
COMMUNITY SERVICES 36 60-482-52 Belfair ext.352
360-482-5269 Elma ext.352
Building,Planning,Environmental Health,Community Health
• 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov
CORRECTION/INSPECTION REPORT
PERMITICASE NUMBER
: 0 Z:L - Lo
ADDRESS/LOCATION: i` r'
FINDINGS:
%fin
r� v
Items listed above must be corrected to fain compliance.
-- IS IS NOT A COMPLETE INSPECTION
❑ This structure has been inspected by Mason County Building Department and the items listed
above are in VIOLATION of Mason County laws and/or ordinances.
—.- all for re-inspection when corrections are made before proceeding with any further work.
❑ Make corrections, items will be checked on the next inspection.
❑ OK to
Date: ('^}—�� � ❑ Please contact our office regarding possible
Department: structural damage incurred by recent
Inspector: 1 y "natural/man made"disasters.This is NOT a
f 1 CORRECTION NOTICE.
DO NOT REMOVE THIS TAG
MCC14.12
Mason County
Il
Mason County - Division of CoMmunity Development
615 W.Alder St.
k
0
Building 8
f 2 124 Shelton,WA 98584
.2 I 360-427-9670 ext 352
www.masoncountywa.gov
BLD2022-00996 ADDITION OR REMODEL-
RESIDENTIAL
PROJECT DESCRIPTION: ADDITION: GARAGE, MUSIC/EXERCISE ISSUED: 01/27/2023
ROOM, OFFICE, CLOSET& UNHEATED ATTIC
SITE ADDRESS: 112 SE EAGLES NEST DR SHELTON EXPIRES: 07/26/2023
PARCEL: 319227590042
APPLICANT: MCCLELLAND CRAIG &KAMILLA OWNER: MCCLELLAND CRAIG &KAMILLA
110 SE EAGLES NEST DR 110 SE EAGLES NEST DR
SHELTON,WA 98584 SHELTON,WA98584
360.427.7116
VALUATIONS: FEES: Paid D--V-q
R-3 VB Residential,one- 814.00 $120,740.62 Building Permit Fee $1,505.84 $0.00
and two-family Change in Tenant-Minor EH $125.00 $0,00
U VB Utility, miscellaneous 783.00 $46,886.04 Plan Review
State Fee-Residential $6.50 $0,00
Planning Review Fee $240.00 $0.00
Technology Surcharge $53.41 $0.00
Mechanical Fees $156.00 $0,00
Mechanical Base Fee $30.00 $0.00
Plan Check Fee $978.80 $0.00
Total: $167,626.66 Totals : $3,095.55 $0.00
FIXTURES
City Mechanical Fixtures
1.0000 Heat Pump(s)
1.0000 Wood/Gas/Pellet Stove(s)
3.0000 Ductless Heat Pump
REQUIRED INSPECTIONS
Pnntea by.Aaane Paysse on OL`27'2023 03 06 PM
Page 1 of 7
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton,WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2022-00996
Setback Inspection Shearwall Inspection
Footing Inspection Framing Inspection
Foundation Wall-Pre-Pour Inspection Mechanical Inspection
Slab Insulation Insulation Inspection
Retaining Wall Inspection BLD-Final Inspection
CONDITIONS
Retaining walls needed to support a surcharge such as structures, roads,or to support slopes, shall require a separate
building permit and approval prior to construction of the retaining wall.
The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not
allowed without the approval of the Mason County Fire Marshal.
Before renovating or remodeling activities in pre-1978 residential buildings or child occupied facilities and to ensure your
compliance with applicable Washington lead regulations, contact the WA State Department of Commerce Lead Paint
Program at; (360)586-5323 or email ibpinfo@commerce.wa.gov. Visit www.commerce.wa.gov/lead for further information.
` Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations(including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur,or when one or more sleeping rooms are added or
created.
REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable
provisions of the current code and the manufacturer's installation instructions.
A drip edge shall be provided at eaves and gables of shingle roofs.
Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the
structure.
Owner 1 Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance
with IECC/WSEC Section R404.1.
All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and
plans are not available on site, then approval will not be granted. In addition, a re-inspection fee(refer to current fee
schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections
being performed or approvals granted.
Pnnted by:Anane Paysse on:01127J2023 03:06 PM
Page 2 of 7
Mason County
pox
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton,WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2022-00996
" Adopted Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less,Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38,and Slab Insulation R-10.
2 Heat pump
1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications:
Vertical fenestration U =0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10
perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by5%
2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour.
maximum at 50 Pascals or For R-2 Occupancies, optional compliance basedon Section R402.4.1.2: Reduce the tested air
leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section
M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a
high efficiency fan(s)(maximum 0.35 watts/cfm), not interlocked with the furnace fan(if present). Ventilation systems using a
furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode.
3.6 Ductless split system heat pumps with no electric resistance heating in the primary living areas.A ductless heat pump
system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor
air temperature.
The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth shall be observed below grade
in undisturbed soils.
The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site,approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
When parcel development requires direct access to county road(s),a Road Access Permit or Approval must be granted by
the Mason County Department of Public Works. For more information contact Public Works, at(360)427-9670, ext. 450 or
100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the
access permit from Public Works has been finaled and approved.
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection.This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
Printed by.Anane Paysse on:01/272023 03:06 PM
Page 3 of 7
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2022-00996
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections,changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
* The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility
of the applicant,owner or contractor to make the required corrections indicated on the plans. Once the plans are marked
"APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is
responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of approved documents will result in failure of required building inspections.
* Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners,connectors,and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your
"Approved Site Plan"to ensure these structures meet the setback conditions listed.
* Ail construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
* Concrete used for basement walls,foundation walls, exterior walls,porches, carport slabs, steps exposed to the weather,
garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of
3000 psi (IRC Table R402.2).
* Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a
permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor
& Industries(L&I).
For more information contact L&I for additional information. In Olympia call(360)902-6350 and in Bremerton call(360)415-
4000.
* All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor
increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way.
* When parcel development requires direct access to state road(s),a Road Access Permit or Approval must be granted and
approved by the Washington State Department of Transportation. For more information contact Washington State
Department of Transportation, at(206)357-2620, ext. 630.
WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind
speed for Mason County is 85 MPH.
Printed by'Arane Paysse on.01127/2023 03:06 PM
Page 4 of 7
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton,WA 98584
360-427-9670 ext 352
www.masoncou ntywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2022-00996
All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or
any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction.
• All property lines shall be clearly identified at the time of foundation inspection.
• Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403,
applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4,all ducts,air handlers,filter boxes,and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants,gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1 t2 inches(38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECCIWSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results(Existing Construction)."Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
Pnnted by Arian Paysse on.0112712023 0106 PM
Page 5 of 7
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton,WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2022-00996
* A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit
application. Design, sizing, placement,inspection and maintenance of stormwater management systems shall be the
responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that
Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement
of any development activities. `NOTE if Stormwater Management option"A"was selected on the Small Parcel Stormwater
Management Application/Worksheet the document entitled"Managing Storm Drainage on Small Lots, The Small Parcel
Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the
development has, or will have,a septic/drainfield system you are responsible for contacting Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,
parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final
inspection of the building permit the owner/agenticontractor is acknowledging that all components of the stormwater
management system have been installed as approved on the stormwater site plan.
Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and
MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either
private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an
existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance
and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting
from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any
construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that
office to review future planned work which may affect your project.
Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site
plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
* A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space
where the furnace is located, a utility room,or an approved location inside the building.When located on the elctrical panel,
the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired
Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceilinglroof,walls,foundation (slab,
basement wall,crawlspace wall and/or floor),and ducts outside the conditioned spaces; U-factors for fenestration;and the
solar heat gain coefficient(SHGC)of fenestration. Where there is more than one value for each component,the certificate
shall list the value covering the largest area. The certificate shall list the type and efficiency of heating,cooling,and service
water heating equipment,duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage
results if a blower door test was conducted.
Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air
changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2.
The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution
panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2.
Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are
available in'/<or Yx sheets.
* The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more
than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards
for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to
another fire apparatus access road which connects to a county maintained public road.
Pnnted by.Anane Paysse on:01,2712023 03:06 PM Page 6 of 7
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton,WA 98584
360-427-9670 ext 352
www.masoncou ntywa.gov
ADDITION OR REMODEL- RESIDENTIAL BLD2022-00996
Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered.
A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations.
B.)Septic tank(s)requires 5ft setback from all footing/foundations.
C.)No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area.
D.) No Cut Bank(s) (greater than 5ft and over 45 degrees)within 50ft,down gradient of Drainfield/Reserve area.
" PLANNING SETBACKS:
Front: 25'
Side: 20'
Rear: 20'
'Measured from furthest projection; subject to EH setbacks
' Building shall not exceed height of 35', measured from average grade.Average grade shall be determined by averaging
the ground elevations at the midpoint of all exterior walls of the proposed structure.
` A separate inspection in addition to the inspections required in the IBC, Section 110 shall be required in accordance with
the 2018 IBC,Section 1705.12.2 and Section 1707.1. The additional inspection is required when shear wall fastener
spacing is required to be 4 inches or less. The shear wall schedule shown on sheet S1 designate wall(s)type W4 with
fastener spacing 4 inches or less.
The required inspection may be performed by the Mason County Building Department, a WABO certified inspector, certified
to inspect lateral connections,the Engineer of record (EOR), or an authorized representative of the (EOR). The special
inspectors duties and responsibilities shall be as specified in Chapter 17, When a third party inspector is used to perform the
inspection, special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton,
WA 98584 and also available on site for review by the Building Official. Inspection reports shall be completed and submitted
to the Mason County Building Department in a timely manner and shall be submitted prior to the framing inspection of said
project.
' Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to
the Mason County Building Department prior to construction. All engineering and/or architectural documents are a part of
the approved set of plans and shall remain attached thereto. If documents are removed, approval will not be granted. In
addition,a re-inspection fee(refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Building Department prior to any further inspections being performed or approvals granted.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By: !{Yl e Al?ayssep
Contractor or Authorized Agent: c'.>'"� - f --'- Date: t - ?-23
Printed by Anane Paysse on 01127/2023 03:06 PM Page 7 of 7