HomeMy WebLinkAboutBLD2016-01087 Final Heat Pump - BLD Permit / Conditions - 11/29/2016 Inspection Line (36U)42/-/262
.-Co�T MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352
Mason County
615 W Alder St
Shelton, WA 98584
1854 RESIDENTIAL'BUIWING PERMIT BLD2016-01087
OWNER: ROBERTABELSON RECEIVED: 11/2/2016
CONTRACTOR: MASON ENERGY LLC 1.360.556.8540 LICENSE: MASONEL852LS EXP: 6/10/2017 ISSUED: 11/2/2016
SITE ADDRESS: 141 E DEER CREEK RD SHELTON EXPIRES: 5/2/2017
PARCEL NUMBER: 321362493110
LEGAL DESCRIPTION: TR 11 OF SE NW LOT: A OF SP#563 (R) S 28/102
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
DUCTLESS HEAT PUMP
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.:
Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: Lot Size: Deck:
Type of Work: ALT Fire Dist.: 5 No. of Stories: Occ. Load: Building:
Valuation: Building Height: Occ. Status: Basement:
Manufactured Home Information Setback Information Shoreline& Planning Information
Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body:
Rear: Ft. Slope: Ft. SEPA?:
Model: Width: Ft. Side 1: Ft. Shoreline Desig.:
Year: Serial No.: Side 2: Ft. Comp. Plan Desig.:
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Heat Pump 1 Final Inspection Fee JBN 11/2/2016 $73.00 S2201600000001
Mechanical Permit Fee JBN 11/2/2016 $ 18.20 S2 2 0 1 6 00000 0 01
Mechanical Base Fee JBN 11/2/2016 $28.50 S2201600000001
Total $ 119.70
BLD2016-01087 Please refer to the following pages for conditions of this permit. Page 1 of 4
CASE NOTES FOR
BLD2016-01087
CONDITIONS FOR
BLD2016-01087
1) Co ractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
Th r are otential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1TURNACE
2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X
2) O is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
3) A INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON
STAT ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM
STAN S SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE.
X
J
4) To perform an inspection the Mason County Building Inspector will need to access the interior of the structure. An electrical permit completed and
approved by Washington State Labor& Industries must be available on-site during the inspection.
The Mason County Building Inspector will inspect the following: Verify that the system is installed in accordance with manufacturer specifications;The
inspector will check to make sure that the exterior unit is permanently installed and supported, the exterior unit complies with required setbacks to
property lines, fuel tanks are located at least 10-ft from the system, a source of ignition,all exterior penetrations are properly sealed,condensate lines are
installed and are properly supported, including proper material, slope, and that the condensate line terminates to a proper location outside of the
found ion, copper refrigerant lines are insulated with '/z"thick continuous closed-cell foam insulation or better, indoor units are located at least 3-ft from
smok��c n monoxide alarms,and that modifications made to the structure, to install the unit, does not affect existing structural members.
X
5) Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC
Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances),
rep i s, or additions requiring a permit occur, or when one or more sleeping rooms are added or created.
X
BLD2016-01087 Please refer to the following pages for conditions of this permit. Page 2 of 4
16) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State o ashington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit at n.
X
7) Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the
IRC, and IMC.
Heating equipment shall be sized in accordance to ICCNVSEC, Section R403.6. Heating and design load calculations for the purpose of sizing HVAC
systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be
available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made
substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous
glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape.
Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-sensitive
tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened.
Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts
shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets
equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s) trained to perform such testing. A signed affidavit documenting test results in accordance
to IECC/WSEC Section R403.2.2 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are
avails le on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct
tight n s to ting is not required if the air handler and all ducts are located within the heated space.
X
8) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have been
identifi and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or
operato s gt3tained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
X E
9) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The con truction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the er a onaI codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspecto . ha I m de prior to requesting additional inspections.
X
BLD2016-01087 Please refer to the following pages for conditions of this permit. Page 3 of 4
10) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to re est a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Maso n rdinances and building regulations.
X
11) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
actio or a eriod not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holde v revented action from being taken. No more than one extension may be granted.
X
12) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these structures meet the setback conditions listed.
X
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s) for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
con truction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PE JIT APPLICATION OF 8 AYS LINVALIDATE THE APPLICATION.
- 4Qk4
Signature Date
OWNER - REPRESENTATIVE - C NfRACTAR'
Print Nam-1e (Circle one to indicate)
BLD2016-01087 Please refer to the following pages for conditions of this permit. Page 4 of 4
00
r- >
CONCRETE MECHANICAL MANUFACTURED HOME
C� Data By M
Footings I Setbacks Ribbons r-
91 Gas Piping CA
C) Intenof Date By Interior-Date By Date By 0
(D
00 Exterw Date By Exterior-Date Bv
4 INSULATION Set-up
Point Load I Isolated Footings BG I SLAB INSULATION Date 11 By__ 0
Date By Date y FIRE DEPARTMENT W
M
Foundation Wails Floors Date BY
Date By Data By DECKS
FRAMING Walls Dale By
Date By Data By PROPANE TANKS
PLUMBING Vault Date By
Date "y OTHER, ........................
Groundwork Attic
Type-
Date By Date By
Date By
D.W.1v DRYWALL Type-
-V Date. 9v InL Brace Wall Date By 00
(D Date By
0) FINAL INSPECTION
CD
CA Water Line Fire Soperation
Co
@ I Data By Dates By D@to 1/7-? BY �tx_
CY)
0 Pass or Request Inspect. 6
5 Type of Insp. Fail Date Date Done By Comments 0
CD 00
o 4
A5li filt-f-hi, h/zf/ti_ J-e
cn
(D
Cn
O
0
0
3
(D
0
A o co�.vr MASON COUNTY COMMUNITY SERVICES Permit No: '�✓ZO��
4 PERMITASSISTANCE CENTER:
•BUILDING•PLANNING•FIRE MARSHAL
615 W. Alder St-Shelton, WA 98584
_- = Phone Shelton:(360)427-9670 ext. 352 Fax:(360)427-7798
RECEIVED
- _— Phone Belfair. 360 275-4467 Phone Elma. 360 482-5269
1854 NOV O 2 2016
PLUMBING & MECHANICAL PERMIT APPLICATION
e�t
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:
O�
MAILING ADDRESS: Id k 6 Deel� MASON ENERGY LLC
CITY, OJ STATE:wR ZIP: 1870 E AGATE RD-SHELTON,WA 98584
Is'P ONE: 1�1 Z j 2.0 — 5"� PHONE: 360-556-8540
2°d PHONE: EMAIL: OUTDOORLIFE44@YAHOOO.COM
EMAIL: MASONEL852LS exp: 6/10/2017
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number): U Zoning:
LEGAL DESCRIPTION(Abbreviated):
SITE ADDRESS: 1 —4 1 _(-- Q CITY: ✓�_
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB
NEW ADD ALT REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS— IT FLOOR 2ND FLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless
Toilets Type of Unit No. of Units Fees T
Bathroom Sink Furnace
Bath Tubs Heat Pump
Showers Spot Vent Fan
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hose bibs Dryer Vent
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revo
Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including
any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is
suspend e for a p riod f 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT PLI OF 180 D INVALIDATE THE APPLICATION.
X 1-7-11
,)�gignature App can Date
X 'Y Owner/Owners Representative/Contractor
Print Name (Circle one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
Visit us on-line: http://www.co.mason.wa.us/community_dev/ Rev:1,/ /2..,1a JBN