HomeMy WebLinkAboutBLD2006-00922 Addition, Remodel - BLD Permit / Conditions - 7/21/2006 Inspection Line(360)127-7262
t ' ' MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352
lo$t
Mason County Bldg. III426 W. Cedar P.O. Box 186Shelton, WA 98584
RESIDENTIAL BUILDING PERMIT BLD2006-00922
OWNER: MICHAEL MCCOY RECEIVED: 5/31/2006
CONTRACTOR: LICENSE: EXP: ISSUED: 7/21/2006
SITE ADDRESS: 2740 SE BLOOMFIELD RD SHELTON EXPIRES: 1/21/2007
PARCEL NUMBER: 319232390010
LEGAL DESCRIPTION: TR 1 G.L. 2 LOT: 1 OF SP #2946
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
ADDITION/REMODEL BLOOMFIELD ROAD TO SITE ADDRESS
General Information Construction & Occupancy Information Square Footage Information
No. of Bedrooms: 3 Type of Constr.: V-B
Type of Use: SF Insp.Area: No. of Bathrooms: 2 cc. Group: R-3 Lot Size: Deck:
Type of Work: ADD Fire Dist.: 4 No. of Stories: 1 cc. Load: Building:0
Valuation: Building Height: 12, �cc. Status: Primary Basement: addition 1,120
Manufactured Home Information Setback Information Shoreline & Planning Information
Make: Length: Ft. Front: W 338.0 Ft. Shoreline: Ft. Water Body: na
Rear: E 230.0 Ft. Slope: Ft. SEPA?: No
Model: Width: Ft. Side 1: N 50.0 Ft. Shoreline Desig.: Not Applicable
Year: Serial No.: Side 2: S 230.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Lavatories 4 Exhaust Hood 1 Plan Check Fee KKK 5/31/2006 $888.18 S22006000
Showers 1 Furnace<100K 1 Planning Review Fee KKK 5/31/2006 $155.00 S22006000
Water Closets (Toilets) 2 Ventilation Fan 4 Building State Fee RTB 6/15/2006 $4.50 S12006000
Bath Tubs 2 Heat Pump 1 Mechanical Fee RTB 6/16/2006 $72.35 S12006000
Dryer Vent 1 Mechanical Base Fee RTB 6/16/2006 $23.50 S12006000
Plumbing Fee RTB 6/16/2006 $63.00 S12006000
Plumbing Base Fee RTB 6/16/2006 $20.00 S12006000
Building Permit Fee RTB 6/16/2006 $1,072.15 S12006000
ADJUST--Plan Check Fee RTB 6/16/2006 -$191.28 S12006000
EH Plan Review TW 7/19/2006 $75.00 S12006000
Total $2,182.40
BLD2006-00922 Please referto the following pages for conditions of this permit. 1 of 4
- CASE NOTES FOR
BLD2006-00922
CONDITIONS FOR
BLD2006-00922
1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
X_
3) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved
access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where
such roa Co
ll
X nn t with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road.
4) All approv d plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Department prior to any further inspections being performed or approvals granted.
X (.
5) In accordance with international codes and Title 14, Mason County Building Code, "Standards for Fire Apparatus Access Roads," all new structures that
require an address shall have approved numbers or addresses located at the beginning of long driveways when the address is not clearly visible from the
access road. The numbers shall also be plainly visible and legible from the street or road fronting the property and shall contrast with their background.
Mason County Building Department requires that this be completed prior to calling for any site inspections. A re-inspection fee based on rates as adopted
by the jurisdiction and the international codes will be assessed if the owner and/or contractor fail to post the address on site prior to requesting
inspections. ,
X
6) The plan re iew check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of a�U
cuments will result in failure of required building inspections.
X�'(�/
7) All exterior wall cavities exposed during construction or remodeling work shall be insulated to the full depth of the wall cavity and inspected prior to
covering. X
BLD2006-00922 Please refer to the following pages for conditions of this permit. 2 of 4
8) Washington State Energy Code Compliance has been approved using the following:
Heat Type: Electric or other fuels, Compliance Method: IV, Window (Max U-Factor):0.40, Skylight (Max U-Factor):0.58,
Doors (Type Max U-Fact r):0.40 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38, Vault Insulation R-30, Slab Insulation R-10.
X
9) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X
10) All construction Zust meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revoca o
X
11) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
ordinance or r g at' ust be reviewed and approved by Mason County prior to construction.
X
12) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shaP be made prior to requesting additional inspections.
X
13) All property lin s shall be clearly identified at the time of foundation inspection. X
14) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinance and building regulations.
XLd
15) All permits expi/el 80 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have nrevente a tion from being taken. No more than one extension may be granted.
X
16) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
X connectors�,and fla king. Install metal connectors approved for contact with the new types of pressure treated material.
I
BLD2006-00922 Please referto the following pages for conditions of this permit. 3 of 4
17) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure
these structures meet the setback conditions listed. '
X
18) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approve Site PI n" o ensure these structures are shown and meet the setback conditions listed.
X
19) Prior to final approval, all upland areas disturbed or newly cre t d by Cgns uction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X
20) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended fora period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owneror the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
D
OWN ER OR AGENT: _ DATE: — j
BLD2006-00922 Please refer to the following pages for conditions of this permit. 4 of 4
iP_;%4CRETE MECHANICAL MANUFACTURED HOME ic
0
Date By ._...w_w .....,..... . ..._. .__ 0Footings Sethackas Cots Piping Ribbons0
D Interior Date By Interior-Date By Date By
N Exterior Date19A/ $�
Exterior-Date Byup
Point Load/Isolated Footings INSULATIONDate By =
Date By BG f SLAB INSULATION - D
Data By FIRE DEPARTMENT M
Foundation Walls Floors Date By r
Date By Data By DECKS
FRAMING walls Date By
Date By Wjj _ Data v-I By `� PROPANE TANKS
PLU BlNG vault Data By
Date By OTHER
Groundwork Attic
TYag=
Date (�j Date By Date By
awv DRYWALL Type_
Int Brace Wall Date By Ip
Date 11'i By LDL Date M By! Z �'� FINAL INSPECTIONCD
p
v
iNaterLine Fire Saperation
m
C
m Date By Date By Date By p
m �
Pass or Request Inspect. c
Type of Insp. Fail Date Date Done By Comments N
m N
E .
0
CD
f s -ss tryo—t
Q, �
S I1 07 W
�aNw L� Xf-- I 7 30 0 7 c ®"� 3 )1q
7 * cal �osg
� 0? Q 01
o l v-i S�-� ,
OL
Building Permit # �Z MASON COUNTY
BUILDING 111 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location ;�-7 kO ".x-ad
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found' Items Listed below must be corrected to gain code compliance
s K-C, Pr--tutu,G- "n I4u1fG.Ji." N1s�' �.� or• y�its
�.�',n'[u�'✓�, ►n-� h. -tv C' ��G �✓' lee'l,,.ram.
'.� ►'t'c.�.'rvl �op� �L"d� V'tJ� Uwe �G' (f+•� �n.e.C.� LJ �. .�.. I
V<-c.✓
•-1'�G tT G , �-Cy t^� AN U i✓►;GC-�/� �JYL.c"lL�t' G tt�•c�L Ti,-cuv�
o 14� s � .
You are hereby notified that the above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
Call for re-inspection when corrections are made before continuing
❑ Make corrections, items will be checked on next inspection
UZl ltjIJf '-T'— 'S")GY u-
❑ This is not a complete inspection Department 13�
Date 71 I t/0-1 Inspector LOY—
son NnT MOOV THU- T U
CZAI
3uilding Permit # MASON COUNTY
BUILDING 111 426 W. CEDAR
SHELTON, WASHINGTON 98584
(360) 427-9670
CORRECTION NOTICE
Job Location .-ZF A7g0 S6-7 )M-
This structure has been inspected by Mason County Building Department
and the following VIOLATION of County Laws and Ordinances has been
found: Items Listed below must be corrected to gain code compliance
►). CaM �� III � -rv,..' k•►� HIS, 1`KC(jl' 4f L54-1: 6W14V41 ,pis
:� f�Cl'!tea O, !JY
u N (urc GS em ,?L ter- ins v►z
You are hereby notified that the above corrections shall be made
BEFORE PROCEEDING WITH ANY FURTHER WORK
❑ Call for re-inspection when corrections are made before continuing
Make corrections, items will be checked on next inspection
OK to ZvK/� � I�p C?j
❑ This is not a domplete inspection Department
Date I�'� U"1 Inspector Li)!Z —
mov NOOT ' M O OV THI
T A '
Mason County Dept. of Community Development
Mason County Bldg. 3
426 W. Cedar
I Pro P.O. Box 186 (360) 427-9670 Local (360) 482-5269 Elma
Shelton, WA 98584 (360) 275-4467 Belfair
Notice to Obtain Final Inspection
November 13, 2008
MICHAEL MCCOY
2740 BLOOMFIELD RD
SHELTON WA 98584
Case No.: BLD2006-00922
Parcel No.: 319232390010
Proiect Description: ADDITION/REMODEL
The Mason County Department of Community Development is currently reviewing all
permits that are expired and have not been approved for occupancy and use.
Pursuant to Mason County Code, Title 14 Building and Construction, a permit and
final inspection for this type of activity is required under the 2006 International
Building Code or the code your permit was issued and your property is currently in
violation status of occupancy and use.
Please contact our office to make the necessary arrangements 21 days from
the date of this letter. Failure to contact our office to make the necessary scheduled
inspections will result in enforcement actions.
To bring your site into compliance, you must schedule an inspection. One (1) $68.00
site investigation fee will need to be paid prior to inspection along with any
outstanding fees currently due on your building permit. For every inspection required
after that, you will be charged $68.00 again, per inspection until final inspection and
conditions are met.
To schedule an inspection, please call (360) 427-9670 ext. 262.
If you should have any questions regarding this notification, please contact me at
(360) 427-9670 ext 595. _
Sincerely, /Z
Rich Todd Balderston
Mason County Department of Community Development
Cc: Property File
November 13, 2008 BLD2006-00922