Loading...
HomeMy WebLinkAboutBLD2024-01422 SFR - BLD Application - 12/5/2024 MASON COUNTY Permit No: U:� IgA,�, COMMUNITY DEVELOPMENPECEIVED Permit Assistance Center, Building,Planning DEC 0 5 2024 BUILDING PERMIT APPLICATION PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: Aider treet NAME:Scot Maclean NAME:Tieton Cabin Co. MAILING ADDRESS:840 SW Westwood Dr MAILING ADDRESS:PO Box 11439 CITY:Portland STATE:OR ZIP:97239 CITY:Bainbridge Island STATE:WA ZIP:98110 PHONE#1:503-816-5836 PHONE:509 673-1030 CELL: 360-870-3671 PHONE#2: EMAIL:alex@tietoncabinco.com EMAIL:scotmaclean@mac.com L&I REG#035,051-03 EXP. T725 PRIMARY CONTACT: OWNER❑ CONTRACTOR 0 OTHER❑ NAME Alex Mondau EMAIL alex@tietoncabinco.com MAILING ADDRESS PO Box 11439 CITY Bainbddge Island STATE WA ZIP 98110 PHONE 360-870-3671 CELL 380-870-3671 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 12018-21-90040 ZONING Rural Residential Z LEGAL DESCRIPTION(Abbreviated)LOT 4 of SP#3034,AF#1926406 PT GL I&TAX I EX S 43/194 FIRE DISTRICT 5 SITE ADDRESS 600 E Plantation Way CITY Shelton DIRECTIONS TO SITE ADDRESS WA-3 N to E Pickering RD follow E to Harstine Bridge,after bridge take right onto E South Island Dr.Follow Way.Follow until end of road with sate with¢ravel road beyond.follow eravel road to address on right IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YESO NO❑ SNOW LOAD:25 psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): SALTWATER E) LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW 0 ADDITION❑ ALTERATION❑ REPAIR❑ - OTHER ❑ USE OF STRUCTURE(Residence,Garage.Commercial Bldg,Etc.)-Residence IS USE: PRIMARY❑ SEASONAL 0 NUMBER OF BEDROOMS 2 NUMBER OF BATHROOMS 1 HEATED STRUCTURE? IYES(Whole Bidg)0 YES(Pan/sl of Bldg)❑ NO❑ DESCRIBE WORK Install%**WA St L&I FAS permitted structures-one w.kitchen&bathroom SQUARE FOOTAGE: (proposed) 1ST FLOG '2 Aq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECKS sq.ft. COVERED DECK 7?— sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* / MAKE Tieton Cabin Co. MODEL Agate Pass YEAR 2024 LENGTH 30 WIDTH 13 BEDROOMS 2 BATHS 1 SERIAL NUMBER wA L&i FAs#to be p' .d d when issued ENVIRONMENTAL HEALTH: SEWAGEISEWER SOURCE: SEPTIC 0 SEWER❑ / NEW 0 EXISTING 0 PLUMBING IN STRUCTURE? YES 0 NO❑ lff jws,attach completed Water Adequacy Form PERIM[ETER/FOUNDATION DRAINS PROPOSED? YES❑ NO[] EXISTING SQ.FT. EXISTING BEDROOMS 0 PROPOSED BEDROOMS 2 TOTAL BEDROOMS 2 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and 1 further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) �� G{h Dec 3,2024 Signature of OWNER(Must be sinned by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH INDIGO ARCHITECTURE&INTERIORS na e. q , nJ Sw.11119 9.tfp Cenpin a,pe.cam �J EXISTING UG OSS PUMP LINE TO REMAIN UNCHANGED. 4 '-1 STING 18ORM PRIMARY FUTURE RESERVE �1 IDRAMIFIELD TO REMAIN OS8IDRAINFIELD PER ® ME O��ep vMnusJlE vuHfwwon E705T•OSSUGS/fBPR.TO\ JCMANGED PER HEALTH HEALTH DE PT RECORDS 9RwoRX Homuo oETAyA faaARFA of REMAIN UNCHANGED,PER \ DEPTRECORDS WORK.WEETAtp1 HEALTH DEPT RECORDS \ _fH42�fJjy,L1(J); _ GENERALNOTES 0 — �yI t - - \ 1 ?"-'4---- -- 11 PER MASON COUNTY MITIGATION MANUAL, W Z APPENDIX B,HE LANDWARD MOST 15'OF THE p - �-- u_ _ SHORELINE SETBACK MAYBE CLEARED. N --- — �\—_ -�\ GRADED,LANDSCAPED AND MAY CONTAIN UP W TO A ZOOSF UNCOVERED DECK,LESS THAN 1'4' Ir- Q ABOVE AVERAGE GRADE. J I PROPOSED UG �/ -\ Z In LINE �oo� 7/SEE ALSO GEOTECH REPORT FOR O ADDITIONAL SLOPE SOIL STABILITY Q V F4� .K^ \ - t INFORMATION. Z i L 31 ALL PROPOSED NEW IMPERVIOUS ROOF w a O AREAS SHALL DRAIN TO TIGHTLINES OR SPLASH U LLi rn -PROPOSED How \ ��- p Fey - \\ 4'sy BLOCKS,AND WATER SHALL BE DIRECTED TO Q o = GRAVEL PKG\ - \ - .roe r NATURAL ADJACENT SWALES IN ACCORDANCE m ti AREA-Y 300SF�. N FR WITH THE RECOMMENDATIONS OF THE '>•. ,.• � i A � A � PS^ JP�. 4\, EXIA WT GRA DRIVE SUBJECT PARCEL •, \�NEWYWTERB \\ \ \� GEOTECH REPORT. 9 TO faEMMMUgCF WGED l 8M E.PLANTATION WAY ,. 7AP11201,St190010 SANITARY 1 i�`;\ 41 ALL PROPOSED NEW GRAVEL DRNES, \ IAISEWER LINES 1 ✓_ PARKING AREAS AND WALKS SHALL BE GRADED TO DIRECTLY SHEET FLOW AND INFILTRATE TO ------ -------------- ----------_j�� / /� i �.` "/ ADJJACENT EXISTING NATURALLY VEGETATED 11 I27I24 AREAS TO REMAIN,IN ACCORDANCE WITH THE \ / RECOMMENDATIONS OF THE GEOTECH REPORT. �Y y 51 THE PROPOSED SFR STRUCTURE IS A FULLY AI8 NRTEeuefnOR0.RERWBDQ" \ / \ wowm— wr­ -�- �._ ' APPROX EXTENTS OF EXISTING FACTORY BUILT STRUCTURE PERMITTED —TEMAROOECKS y�f TREE CANOPY TO REMAIN SEPARATELY UNDER THE WA STATE L&I FAS pt.wavEmel REV.ApO aespEEgYE UNCHANGED,NO TREE REMOVAL PERMITTING PROGRAM. THE APPLICANT SHALL AO,ueTlme.Amunre.aereaAR PROPOSED. PROVIDE PROOF OF FAS INSIGNIAIAPPROVAL \ PRIOR TO DELIVERY OF THE STRUCTURE TO THE — - 1 SITE. 1 61 THE PROPOSED SITE BUILT \\ y3AM t pa III FOUNDATION OR HE FAS STRUCTURE IS PART OFF THIS PERMIT 9NEETNME EXISTING SFR ADJACENT PROPEORTV APPLICATION,SEE ALSO INCLUDED STRUCTURAL SITE PLAN S FOUNDATION AND DRAWING SHEETS AND CALCULATIONS. NNITH WITA100EL. EH SETBACKS SITE SUB COORD A) Drainfield/Reserve requires 10' setback from footing/foundations EH APPROVED B) Septic tank(s) requires 5' setback from all footing/foundations A1 .20 Q No foundation/perimeter drains within 30' down-gradient of drainfield/ D.Anderson 01/07/2025 reserve area D) No cut(s), bank(s) (greater than 5' &over 45 degrees)within 50' down-gradient of drainfield/reserve area I.. 0 ♦ Name rmbl MA-, Parcel#�2I D�'��-CjbD�(� BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: httpHwww.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in&'rtirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical:415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other, parcel.You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT.352 Mail: P 0 Box 1666, Shelton WA 98584 Physical:426 W Cedar St,Shelton WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that dy inf rmation provided is accurate and employees of Mason County are granted access to the above- described p for r e d inspection as may be required. X Owner/Ag ontrac or ircle one)Date: age 2 of 2 j., . f r Name Parcel # BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code, Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development, or redevelopment', with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. -Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area "All dimensions in feet Buildings X p` X = Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X = X = Length of drive begins at the right of way X = Parking Areas X = X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. 1 declare that I am the owner,owner's legal representative,or the contractor. I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Owner/Agent/Contractor(circle one)Date: If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign the information provided on page 2 of 2. Pagel of 2 105' INDIGO f 00' 95' '90 85' 80' 75' 70' 65' 60' S5' S0' / / �. .'.'\'.'.'.'1♦ \ \ \ \ \ / ARCHITECTURE&INTERIORS —" po boz 11439 — — — — � — — — — — _ \.- .-•- - ••\ \ \\\`��_ \\\ \ \\ \\ \\\ \\ \\ \\ 206.909.086 — -7- — — — — bainbridpe island�wa 98110 .:. beenp-dipo.— / I NEW GROUND RACK MOUNTED / I PVISOLAR PANELS / I I \.'.'.•.'.".'.'.'.'.'.\\ TOGEXISTNG 3BgU1G J�, \ DRAI FIELD TO REMAINT \\ g!-r=.'r- EXISTING SEPTIC \ . .. .T. \ \` \ UNCHANGED REMAIN UNCHANGED \\\ PEXISTING OSS ANEL TO REMAIN `\ \\, \\ \\ \\ UNCJ'A 01 96, / GO 99, / , \ PROPOSEDSHED ROOF GUTTERIDONNSPOUT _-1� NEW POST MOUNTED---- \ To TIGHRXNE7lT6R�DE.TKiHRlE EXTE�4 gSCQNECT FOR-NEW BLDG - TO ALLOW SURFACE DISPERSION TO NATURAL I _ _ INTERIOR ELEC PANEL. _ _ _ A, \ \\ a \ \ \\ \ \ .� SWALE TO NORTH OF BLDG FOOTPRINT. W 1d1' Nov EXIST ST Mb'�_ ---- 1 EX NEW . ' Eb NEW UG OSS \ TOIEMAIN _ _ 'UNE \\ \\ U ETO REMAIN ,m ° \ \\Aw, W 4X1A8X4D)NEWGPCONC SFR PIER FTGS,PER STRUCTL FNDTN PUNS W . I .{��=r s-'�(/B1"' ',• '. ...� \ \ `\ \ \\ (u SHOWN DASHED BELOW__ �- \ —————— — — — a —iFJB`' `. _. PROPOSED Q -_ atd�_ w l rLti� 1 r , - •.-.\. Ai GRADE 1 \ \ \\ \ W ----=� H ' LJ . ,'\ 1 .�' T IG POWER u1E taA "9-c \ `\ J Z r _ Q. u5 o 1 - \_ _ Q 1 r \ \ 1 -�- -=_-tEIN4W f1WWF/P1cGAlERl0.- _-�\ L _� o $ ; NEW DECK FaoTNG9 \ 0�?'` -_ _ --- PROP(L7SED MasoNGwN1Y c\ I `' \ \ F rn - ��__ - ' ' "1 \DE ..• z'� SHOWN DASHED,TO WEE /it NATU ��++--___-= NATllRALLY______________ _a> , : 1-BDRM�FR 1p- • . • Q cn_- � 2TNE DECK FTO 1 Z ?,VESETA]1!@!� IOC______________ Yr 3 S FFE1fV.., '\ RW. 1EXISTING GRAVEL <- -__ ---_ {- - _ _ §DRNE TO REMAIN JSR�CATFD BYFIEIKXKi01YS_ 4 p b ''� -"�'=•:' + Q W _>___ -____ Z Z + =y -+_________-_ __________________ _� / ram, 1 W 1 _ ------------=- ---====-------------\ r1i i 3 m _ _ rE � '� m GENERAL NOTES V w --i � Q W_ 11 PER MAS Q ON COUNTY MITIGATION MANUAL,APPENDIX O 1 1-_--- - --- �' -----------------} � b12 y C"+•r^p B,THE LANDWARD MOST 150F THE SHORELINE SETBACK Xp U) - Ile '.' °y MAY BE CLEARED.GRADED,LANDSCAPED AND MAY 79'-T � 1 CONTAIN UP TO A 2ODSF UNCOVERED DECK,LESS THAN T-T E ___�.- . . •.1.' '-'�`0 1 ABOVE AVERAGE GRADE. F---=__-- _{ �_'_____________ ___}______________ ARFA�OFRLOPQEB SqL \ - I k - _-= x====____====J l� t . . . . . fly' 1 _ I L SEE ALSO GEOTECH REPORT FOR ADDITKINAL SLOPE _ - -- ----------=---J NEW WWATERLOE FROM NEW• •�•�. ______ ______________� - � ,,`. 1 ` 1 \ I 1 SOIL STABILITY INFORMATION. PRESVLRE WHK tO f6YJJ SFA.'.'.•.'.'. "J'.� ::,tjA 1 I 1 / __ _______ SLE¢VE WHENy,Nj0l QFVN.'. .'.'.'.-J' �•� ___________ _ - - t•• I \ 1 31 ALL PROPOSED NEW IMPERVIOUS ROOF AREAS SHALL 1 _ i_ fEYYfRAVEi_ _ AREA TO __ __--_--- '� .'? 1 1 DRAIN TO TIGHTLINES OR SPLASH BLOCKS,AND WATER 'I J 1 27 I Z4 / W �---- --_ _ ___ StiEETFTAWDI6PERSE TO & NEW 1510J 9EIVER tlFP FR0•M'EXISJ• •/� j \\R I. I SHALL BE DIRECTED TO NATURAL ADJACENT SWALES IN �pJ�t NfNCTURALLY 5 TO 1EWSFR SM15E1AER Wlb - %'/' ,(/, _ T�Ef:ET�fTED AREAS TO REMAIN / F lfY1 U1IIpOfO'LWStlERJR SE1ED'.'_-.'/' / - // --/ •-• F•• \ I ACCORDANCE NTH THE RECOMMENDATIONS OF THE lOS 1�I __ -��_ _ ____________________�OOIGQED BY FLOW ARROWS r '.J . . , . . . .' 1 GEOTECH REPORT. REVISIONS - -_ -- I, PIE ' / \y. J \ 1 4 ALL PROPOSED NEW GRAVEL DRIVES,PARKING AREAS ly// AND 108, / p / \ II AND INFILTRATE TO ADAJACENT EXISTINGNATURALLY L W/ 9° tF . . ' 102' PROPOSED-2,300SF NEW /100 w' .8g' p. 1 VEGETATED AREAS TO REMAIN,IN ACCORDANCE WITH THE SED NEW OG POWER LINE RECOMMENDATIONS Of THE GEOTECH REPORT. / GRAVEN DRIVE AND PARKING 5' / AREA.SHOWN DOTTED HATCH r ,H ' FROM NG P NEW BLDG pISCONECTISUB PANEL •'.'.. / �� -,�.�l•.�.•.•.�.� •J• 1 51 THE PROPOSED SFR K DETACHED GUEST QUARTERS / r1 ; 99' pSA _ '\ 1 STRUCTURES ARE FULLY FACTORY BUILT STRUCTURES, / Fyt503 2 r , -` \ PERMITTED SEPARATELY UNDER THE WA STATE L&I FAS 1 �• 1 k00Fi0ORNM 1 g> / PERMITTING PROGRAM. THE APPLICANT SHALL PROVIDE PROPOSED NEW E POWER LIKE 1 PROOF OF FAS INSIGNWAPPROVAL PRIOR TO DEUVERY OF FROM EXISTING METERPII TO NEW \� EX.SIED 9 TWELL LEAD P" 1-'.'.'� I \ 1 THE STRUCTURES TO THE SITE. FF.101.OIT 3: BLDG gSCONNECTiSl1B PANEL \ 1 61 THE PROPOSED SITE BUILT FOUNDATION FOR THE FAS SHEET NAME STRUCTURES IS PART OF THIS PERMIT APPLICATION.SEE EXISTING SHED ROOF GU7ER'DOWNSPOUT _-% - w ,'� \ I ALSO INCLUDED STRUCTURAL FOUNDATION AND DRAWING PARTIAL SITE PLAN: / DAYLIGHTS TO SPLASH BOCK AT GRADE. ram_ P-T'C / I LJ j ,-I' \I I SHEETS AND CALCULATIONS. GRADING UTILITIES / Sl1RFACE DISPERSION TO NATURAL SWALE TO 1 H gg L� / SOUTH OFBIDGFOOTPRINT. MEYVNTERIORFIEC TING POST LJ-� rl1m o PR ED PROPOSE .� I 7H EXISTING TOPO LINES(DARK DASHEDI ARE SHOWN AT AT AREA OF WORK Qa WITHIN / / I PANEL QEJITS7 SHED __ Q L O 1-BDRM D �US - S S�nFOOTINGS S-V THE INCREMENTS OUTSIDE OF THE AREA LI WORK.HED) `/ 1 MOUNTED ELEC METER. ��_ _ pSCONECTAND PANEL - �, ,' ( SHOWN DASHED,TO MEET THE DIRECT Of WORK LINES(LIGHT DASHED) - & 4 _ MASON COUNT' ARE SHOWN AT 1'4'INCREMENTS FOR PURPOSES OF MORE \ H / DECK FTG ACCURATELY DEPICTING CUT AND FILL GRADING WORK. IINRMOOELt / ,'r .-f NEW 11G WATER LINE�d l _ _ X' T QTI�V. CRITERIA / FROMWELLHEAD- -- H rl,H Z / -- - - FF ELEV.W8.50 H .PRD?SsoO 915F. �. . / - -------------EWPRESSURE TAIL r TTED WOOD DEG(, \ / / ._ INSIDE EXISTING SHED -- - 27V b1�2D24- D I� a. I g•-r __ --- NEW POST MOUNTED // - � - - // i // •� _ ------ --____-_-----— 1 DISCONNECT FOR NEW8Ub6� ISSUE /� // _ r1 -��_.IN,EIBORECcFC PANEL. . . .'.'.'. .'.'.'.'.� / ' / ----_ EDSHEDROOFGUTTEROD'M.S:OUT / \ - / PERMIT SUBMITTAL 100,--------- �\ // -_- ---����---- TO TYHTUNE AT GRADE.TrFnUNE EXTENDS - TOALLOWSURFACE DISPERSKXNTO NATURAL/ \',','.',•.',','.','_','\ //SWALE TO SOUTH OF BLDG FOOTPRINT. A1 .21 99, 98, 97' 96' 95' 90, 85' NORTH 01 PARTIAL SITE PLAN:GRADING&UTILITIES AT AREA OF WORK 0 4 8 18 • ¢ss'w�iwan TME u ucxHrtcrs Nc�cmor+n+w er% INDIGO ARCHITECTURE&INTERIORS Pb box 11439 ba,Abr,4ge island wa 98110 2 C16.909.0884 bein llp��id,gP.<om R AR ECT EXISTING WELL HEAD SERVING ADJ PROPERTY TO NORTH TO REMAIN UNCHANGED PER HEALTH .IER IcNB RG DEPT RECORDS A o w�N ou / EXISTING 3$DRM vD5R0�19M'M OSSIDRAINFIELD TO REMAIN EXISTING UG OSS PUMP LINE TO REMAIN / UNCHANGED PER HEALTH UNCHANGED. DEPT RECORDS EXISTING PRIVATE DRIVE 476- 1 TO ADJACENT PROPERTY R700'-O• I 1 TO NORTH TO REMAIN \ I EXIST.OSS UG SIT&PIT,TO \ UNCHANGED I REMAIN UNCHANGED,PER \ ,p.__.\ •\ „o ,� -- I _-.--- ---- _-- _ HEALTH DEPT RECORDS \\ GENERAL NOTES z U 1/ PER MASON COUNTY MITIGATION MANUAL, W APPENDIX B,THE LANDWARD MOST 15'OF THE SHORELINE SETBACK MAY BE CLEARED, C1J --_�-c_ -_ ` GRADED,LANDSCAPED AND MAY CONTAIN UP W TO A 200SF UNCOVERED DECK,LESS THAN 1'-0" Q \ \ &� p SEE ENLG'D PAR IAF sRE�i ss 1 \ • \QA ABOVE AVERAGE GRADE. LLB ?� v PUN FOR ADDIVL K I / �t� � , o J z oO-, o _ _ __ '• _ _ \ \ NOTES MID 1 / CASE*YET DETAP.t`WR AREA OF SEE GE I r 21 SEE ALSO GEOTECH REPORT FOR O CDz E.PLANTATION WAY \ WORK,SHl'l4Ai` T 4 `'� NOTE i \�� \ l ADDITIONAL SLOPE SOIL STABILITY Q NEW i q��E ���� INFORMATION. Z 1-- 3�i S Q Q 3l ALL PROPOSED NEW IMPERVIOUS ROOF W a O \ — PROPOSED NEW \ I �aRE ,l�t AREAS SHALL DRAIN TO TIGHTLINES OR SPLASH (� w w P ' - \ ' \ BLOCKS,AND WATER SHALL BE DIRECTED TO Q o Q o GRAVEL PKG m A AREA:-2.300SF � � A + d� �� � NATURAL ADJACENT SWALES IN ACCORDANCE � U) ��. 9\ I i \�oE� 5 •�*� WITH THE RECOMMENDATIONS OF THE GRAVF\L DRIVE 1 SUBJECT PARCEJ a 2 ` f 5� ` \\� GEOTECH REPORT. r �\ TO Ri MAIN UNCHANGED I I 1600 E.PLANTATION WAY 9< ' TAP#:12018219 0040 g� ' r 41 ALL PROPOSED NEW GRAVEL DRIVES, •` \ I \, 33' PARKING AREAS AND WALKS SHALL BE GRADED GE_ _ / ' 411 o TO DIRECTLY SHEET FLOW AND INFILTRATE TO ADAJACENT EXISTING NATURALLY VEGETATED 1 27 24 AREAS TO REMAIN,IN ACCORDANCE WITH THE 11 RECOMMENDATIONS OF THE GEOTECH REPORT. REVISIONS \ �� —� ? _ +' y �\ �� D _ 51 THE PROPOSED SFR&DETACHED GUEST 1 W?OPERTY APPROX EXTENTS OF EXISTING QUARTERS STRUCTURES ARE FULLY FACTORY TREE CANOPY TO REMAIN BUILT STRUCTURES,PERMITTED SEPARATELY UNCHANGED,NO TREE REMOVAL UNDER THE WA STATE L&I FAS PERMITTING PROPOSED. PROGRAM. THE APPLICANT SHALL PROVIDE �__________����/ \\ PROOF OF FAS INSIGNIAIAPPROVAL PRIOR TO _ ______ � DELIVERY Of THE STRUCTURES TO THE SITE. \ p 1 1\ 61 THE PROPOSED SITE BUILT FOUNDATION FOR 11 THE FAS STRUCTURES IS PART OF THIS PERMIT SHEET NAM Fp RAG EXISTING SFR ON APPLICATION,SEE ALSO INCLUDED STRUCTURAL SITE PLAN ADJACENT PROPERTY FOUNDATION AND DRAWING SHEETS AND CALCULATIONS. 75IGI202z- O 14 NORTH LINT4MI.IF of SITE PLAN 0 15 30 00 ISSUE PERMIT SUBMITTAL A1 .20