Loading...
HomeMy WebLinkAboutBLD2007-01855 Final Furnace and HP - BLD Permit / Conditions - 11/2/2007 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 MECHANICAL PERMIT BLD2007-01855 OWNER: HAZEL, SPEECE RECEIVED: 10/25/2007 CONTRACTOR: NORTHWEST REFRIGERATION 360-357-9973 LICENSE: EXP: ISSUED: 10/25/2007 SITE ADDRESS: 393 E CRANBERRY CREEK RD SHELTON EXPIRES: 4/25/2008 PARCEL NUMBER: 321362100040 LEGAL DESCRIPTION: NW NE NW PROJECT DESCRIPTION: DIRECTIONS TO SITE: HEATPUMP, FURNACE OUT HWY 3 TO DEER CREEK STORE, TURN LEFT ON CRANBERRY CREEK RD 3/8 MILE DOWN RD TO WHERE RD TURNS TO THE RIGHT DRIVEWAY ON THE LEFT. General Information Mechanical Fixtures FEES Type of Use: SF Insp.Area: Type Qty. Type By Date Amount Receipt Type of Work: MEC Fire Dist.: Furnace<100K 1 Mechanical Base Fee KS 10/25/200 $25.30 S12007 Heat Pump 1 Total $25.30 BLD2007-01855 Please referto the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD2007-01855 CONDITIONS FOR BLD2007-01855 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X a.137 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X .0..3 3) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM STANDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE. X ,y,3 4) In buildings of unusually tight construction, fuel-burning appliances (excluding cooking appliances and domestic clothes dryers) shall obtain combustion air from outside in accordance with the international codes. X 0!>',3 5) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150' from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. X 42 n3 6) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X yr,3 BLD2007-01855 Please referto the following pages for conditions of this permit. 2 of 3 7) Installation of heating equipment in single family residences shall meet the requirements of the current Washington State Energy Code. « The furnace to be installed shall not exceed 150% of the heating and cooling design load. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted engineering practice, including infiltration and ventilation. Design calculations shall be available for inspection during the framing inspection. Warm-air furnaces shall have a minimum efficiency of 78%AFUE or higher or 80% combustion efficiency. All ducts shall be securely fastened and sealed with welds, gaskets, mastics(adhesives), mastic-plus-embedded-fabric systems or tapes installed in accordance with manufacturers installation instructions.�uct tape is NOT permitted as a sealant on any ducts. Ducts in unheated spaces shall be insulated to R-8. X �- This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of rDrk is a progress i spection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of .work is by means of a progress inspecti The owner or the gent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property ai I r" ure for review and spection. OWNERORAGENT: / `�"'� ' �--�— DATE: _GJ, BLD2007-01855 Please refer to the following pages for conditions of this permit. 3 of 3 Gas Piping Cn o CONCRETE MANUFACTURED HOME Interior-Date By C) M C) Footings I Setbacks Ribbons m EXterKv-Dare By 0 CD Da to By Date BY 00 INSULATION (31 C n Foundation Walls BG I SLAB INSULATION Set-up Date By Gate By Date By M FRAMING Floors FIRE DEPARTMENT Date By Da to BY — Da to BY Walls DECKS PLUMBING D ate By — Da to By Groundwork Vault TANKS Date By Date BY Date By Attic OTHER D.W.V Date By Date 13Y DRYWALL Type_ Date BY Water Line Date BY Type: Date BY Int,Brace Wall Date By BY 0 MECHANICAL Da te- seperation FINAL INSPECTION Fire 7 -4 i3 Date BY ate -BY Date ZJ 6 Ry. CD o 0 Pass or I Request Inspect. 5 Type of I nsp. Fail Date Date Done By Comments CD Er 2� 0 fR CD CD 0 • • MASON COUNTY PERMIT NOP`—'—" PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360)427-9670•Belfair(360)275-4467•Elma(360)482-5269 On the web www.co.mason.wa.us APPLIqA,NT INFORMATION ` CONTRACTOR INFORWI Owner �?P e ccc Company Name�� 1'�p r�Q p �a Mailin Addres Mailin Addresss s � g 3 � Cc r. �� ,��.�c Qa a�k c���tkjck mac„ City State W A Zip Code 9 Sgy City State`-y A- Zip Code 9kZQ' Phone_ Other Ph.- Phone 2''s 9 g 3 Oth r Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No Fire District Legal Description Site Address (Please include street name, street number and city) Directions to site_�y"3— L_ ac, Cc axe &'Tav ct Is property within 200' of Saltwater_ Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add ,_Alt Repair Other Use of Building Location of Fixtures/Units- 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric LPG_Natural Gas_Heat Pump— Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kithen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hosebibs Dryer Vent Other Other Ease Fee Base Fee TOTAL PLUMBING— . TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work ordor or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other pa in interest regarding this application or the work proposed in the application,I have obtained party 9 9 aPP P Po PP permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accu ate and grants employees of Mason County access to the above described property and structure for review and inspection. PR F O IINUATION O WORK IS BY MEANS OF A PROGRESS INSPECTION. Date: �"�" 07 Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Planning Pd Ck# Date Bld Pd Receipt No. DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Occ Grou —TVI)eConstr.- Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical & Base fee UFC Plan Review Fee Wood/Gas/ Pellet Stove Fee Other Violation Fee TOTAL FEES