Loading...
HomeMy WebLinkAboutSWG2024-00455 - SWG Application / Design - 11/26/2024 SHELTON,WA MASON COUNTY 415N6THELTON: , 0427-97 ,EXT 400 SHELTON:360327-9670,EXT 400 BELFAIR:360-2754467,EXT 400 Public Health & Human Services ELMA:360482-5269,EXT 400 FAX:360 427-7787 On-Site Sewage System Permit: SWG2024-00455 0L)Pir7 APPLICANT SHELDREW PAIGE &SPENCER Phone: Address: 5182 HUNTERS RIDGE WAY HUNTERS, WA 99137 OWNER SHELDREW PAIGE &SPENCER Phone: Address: 5182 HUNTERS RIDGE WAY HUNTERS, WA 99137 SEPTIC DESIGNER PAULAJOHNSON' Phone: 360-898-2255 Address: 171 E VUECREST DRIVE UNION,WA 98592 SEPTIC INSTALLER JOHN GILLILAND• Phone: 360-898-4388 Address: 1510 E MCREAVY RD UNION,WA 98592 Site Address: 100 E GLENWOOD DR Primary Parcel Number: 321057690020 Permit Description: New 3bd ATU to pressure trench Permit Submitted Date: 1112612024 Permit Issued Date: 01/0212025 Issued By: Rhonda Thompson Current Permit Fees Paid: $540.00 laamdmal raesmay Ire required upon lnsYlladcn ofnyarem). Permit Expiration Dale: 12130/2027 roasad oa sale armapanloa) Permit Conditions: 1 Proposed development subject to zoning requirements and approval by the planning department staff per Mason County Title 17. 2 Permit must be installed by a Mason County Certified Installer unless prior written authorization from Mason County is obtained. 3 Drainfield installation not to exceed designed upslope and downslope depth specified on design form. .4 Installer is responsible for obtaining Mason County installation approval prior to backfill of system components. 5 Installer is responsible for obtaining Septic DesignerlEngineer installation approval prior to backfill of system components. 6 Mason County Asbuilt Form, Record Drawing, and Installation fee must be submitted for j! final installation approval. 1 THIS PERMIT MUST BE ONSITE DURING INSTALLATION OF OSS. PROPERTY OWNERS ARE RESPONSIBLE FOR DETERMINING AND MARKING ALL PROPERTY LINE AND EASEMENT LOCATIONS. THIS PERMIT MAY BE REVOKED IF THE SITE CONDITIONS HAVE CHANGED SINCE THE SITE WAS INSPECTED AND DESIGN APPROVED. FINAL INSTALLATION APPROVAL IS REQUIRED PRIOR TO TEMPORARY OR FINAL OCCUPANCY OF ANY RELATED STRUCTURES. For Final Inspection visit: masoncountywa.govlhealth/onvimnmentallonsiteloss-inspection-request.php or call: 360-427-9670,extension 400. s OFFICIAL USE ONLY ® eux.am s,n" Eyucesu n WaEPKEne4 MASON COUNTY / _ Z - 2 COMMUNITY SERVICES MIOVXTMOK qo PKEMP. c m PubB[NWMIUmmmmunlYXpahNFnvim merrtal KealNl G o SWG 202 - DoN55 a A Z 4 ON-SITE SEWAGE SYSTEM APPLICATION a 'n 3 n PPiuGArvT PHONE m m r Spencer Sheldrew f (425) 417-7563 c MAILINGADDRESS-STREET CT..STATE.EIPCODE nJLJ( m 5182 Hunters Ridge Way Hunters, WA 98137 A SITEAWRESS-STREET,CITY.VFCWE N 100 E Glenwood Dr o Union, WA 98592 NAME OF CEEGNF I PHONE I N Arrow Septic Designs, Inc z (360) 898-2255 NAME OF INSTALLER HO O John Gilliland -Arrow Excavati itP(03NE 0 898 4388 w I o PERMRttPE IYWYMBI DRINKING MMTER SOURCE O ®RESIDENTIALOSS 5COMMUNITYOSS EiCOMMERCIALOSS h PRNATEINDNIDUALWELL hPRIVATE TW PARTY WELL 2 I � TYPE OI NMRK RSM . ®PUBLIC WATER SYSTEM Fuvn ®NEW OONBTRUCTIONIUPGRADES ffREPAIRIREPLACEMENT OTHER DEwL5latlxf an m aRPO OTABLE IX REPAIR ICI TI su.'VAIS OSURFACINGSEWAGE ❑EXISTINGFAILURE ❑SHORELINE W 111DESIGN FORM IREOUIRED) 19SEPTIC DESIGN(REQUIRED) BEDROOMS LOT 9EE r0 I � MIVER(S)(IFAPPLICABLEI 3 1.42 Acres bU DIRECTIONSTOWEAHDSITECONOITIONSla<.I pfe) Go through the roundabout and head up Northcliff Rd. Turn (R) onto E Brockdale Rd. c Continue on E McReavy Rd. toward Union, turn (L) into the Vuecrest Estates neighborhood r onto E Vuecrest Dr, take the 3rd (R)onto E Glenwood Dr, property is all the way at the end, ° o yellow sign "Sheldrew" I N SITE MUSTBEPLA E F JNNI FQAOANOT THOAZSMVSTAEPAOGED W/ TESTMIXENLYIERS OFFICIAL USE ONLY BELOW THIS LINE — UPGRADE I FAIURE$OUNCE(W rv"„ 1u1 1 OVOLUNTARY OMAINTENANCEIPUMPING O BUILDING PERMIT OHOMESALE ODOMPLAINT OOTHER: INS1£CTORSOILLOW COMMEMSIOONDTTg SS N� �EJLjl�S S SOIL COOFB' REWflOIXiAN1NGANOINSTALIATK.W REPoRT V=VERY G=GRAVELLY S-MND L=LOAM $I=SILT C-C,AY E=EXTREMELY R=ROOTS REOUWEDFORFINALAPPROVAL. INSPECTOR SIGNATURE WE APPLICATION E%FRATICN DATE APPLICATION APPROVED 155UED BY GATE Czh o zS TNIS FORM MAY BE CANNED AND AVAILABLE FOR PUBLIC VIEW ON THE MASON COUNTY WEBSITE REVIBED)Y120T5 DESIGN FORM—PAGE ONE Assessor's Parcel Number: 3 2 1 0 5 — 7 6 — 9 0 0 2 0 A design will be reviewed when 3 copies of each of the following are submitted: r Completed design form that has been signed and dated. I Scaled layout sketch,including all applicable items on checklist Scaled plat plan,including all applicable items on checklist. O Cross-section sketch.including all applicable items on checklist. This form may be scanned and available for public view on the Mason County Web site, 14nxitium u er.tiize: 1 i \'/? PARCEL IDENTtfiCATION Permtthumber: SWG�2�LY ' ��� Designer's Name: Arrow Septic Designs, Inc Applicant's Name: Spencer Sheldrew - Designer s Phone Number: (360)898-2255 Mailing Address: 5182 Hunters Ridge Way Designer's Address: 171 E Vueemst Dr Hunera, WA 88137 Union, WA 98592 City Stare Zip City State Zi a;_:. DESIGN PARAMETERS Treatment Device ❑Glendon Biofilter ❑Sand Filter ❑Mound ❑Sand Lined Drainfield ❑Reoiroulsting Filter,Type: NuWater BNR300 500-gal pre-trash tank fil(Aerobic Unit Meke/Motlel ❑Disinkctinn Unit Make/klodel Other: _ Drainfield Type ❑Gravity liif Pressure 17f Trench ❑Bed ❑Sub Surface Drip Septic Tank/Drainfield Specifications Laterals Number of Bedrooms 3 Schedule/Class 40 Daily Flow:Operating Capacity 270 gpd Length 30 ft Daily Flow:Design Flow 360 gpd Diameter 1.25 in Septic Tank Capacity(working) NUWater BNR-500 gal Number 5 Receiving Soil Type(1-6) 3 Separation 5 ft Receiving Soil Appl.Race 0.8 gpd/ftt Orifices Required Primary Area 450 ft` Total Number of Orifices 30 Resigned Primary Area 450 ft, Diameter 3116 in Designed Reserve Area 450 ft' Spacing 60 in Trench/Bed Width 3 ft Manifold Trench/Bed Length 150 ft Schedule/Class 40 Elevation Measurements Length header it Original Dninfield Area Slope 15 % Diameter ../1.25 in New Slope,If Altered 15 0/ Preferred manifold configuration used? m Yes O No Depth of Excavation Ur-slore 16 in Transport Pipe from Original Grade down- ., 11 in Schedule/Class 40 Designed Vertical Separation 14+ in Length 80 ft Gravelless Chambers Required? ❑Yes ❑No 90ptional Diameter 2 in Pump Required? If Yes O No Dosing and Pump Chamber Pump/Siphon Specifications Numberofdoses/day 4 Diff.in Elevation Between Pump& Uppermost Orifice 1e it Dose quantity so gal Drainfield Squirt Height/Selected Residual(head) _2_ft Chamber Capacity(Flood) 1,000 _gal Uppermost Orifice If Higher ❑Lower than Pump Shutoff Pump controls:Please check those required. Capacity @ Total Pressure Head 17.70 gpm l7(Timer fsl(Elapse Meter IEvent Counter Calculated Total Pressure Head 17.92 ft If Timer: Pump on 2.5 min ,Pump off 6 hr Comments APPROVED JAN 02 2025 u I&b10 RET DESIGN FORM—PAGE TWO Assessor's Parcel Number:3 2 1 0 5 — 7 6 -- 9 0 0 2 0 Permit Number: SWG DESIGN CHECKLISTS Scaled Plot Plan Scaled Layout Sketch Cross-Section Sketch R1 Test hole locations 19 Drainfield orientation and layout Reference depth from original grade: 56 Soil logs Rf Trenchlbed dimensions and 66 Septic tank 91 Property lines critical distances within layout 19 Drainfield cover ❑ Existing and proposed wells Ed D-Box/Valve box locations Reference depth from original grade within 100 ft of property Rf Septic tank/pump chamber and restrictive strata: 0 Measurements to cuts,banks,and locations 19 Laterals,trench/bed,top and surface water and critical areas 19 Observation port location bottom ❑ Location and orientation of 9 Clean-out location ❑ Curtain drain collector curtain drain and all absorption Rf Manifold placement ❑ Sand augmentation components Sri Orifice placement Other cross-section detail: Id Location and dimension of fig Lateral placement with distance Rf observation ports/clean-outs primary system and reserve area to edge of bed Other Information m Buildings Ed Audible/vis referenced Yes No 9 Direction of slope indicator Rf Scale of dre wn on scale Ill ❑ Design staked out R1 Waterlines bar e ❑ G6 Recorded Notices attached Id Roads,easements,driveways, .o .+ r ❑ Rf Waiver(s)attached parking Y, 56 ❑ Pump curve attached R1 North arrow and scale drawing y 1 ❑ [if Evaluation of failure shown on scale bar - 51003a9 Non-residential justificatiou PAULA JOY JOHNSON', 0 1 ❑ If Waste strength apyaa ❑ 9 Plow DESIGN APPROVAL The undersigned designer must be rpified insta er at time of installation 16 Yes ❑ No I1 - t -_Z* Signature of Designer Date The undersigned has reviewed this design on behalf of Mason County Public Health and determined it to be in compliance with state and local on-site regulations: Ennnmev n S Dale CAUTION: DESIGN APPROVAL IS VALID ONLY UNDER THE FOLLOWING CONDITION: ✓ The design is stamped"Approved"by Mason County Public Health. -, ✓ The Onsite Sewage Permit has not expired,the Permit Expiration Date is: ✓ Drainfield site conditions have not been altered to adversely affect conditions of design approval. Please Note: The system must be installed by a certified installer, unless prior authorization is obtained from Mason County Public Health. An Installation Fee is required. This form may be scanned and available for public view on the Mason County web site. Updated Date: 12/72015 ND am N i > S = . S g k f'rrr rri a 43 ♦♦ .e iee - (TT� 3Tn �dcYia3s�9d !wild ia..iqty N-1„ ;11, Hai Rom. c a \� �4 3R = 5 3k d3 ByiS Y�k �i'A nD „ I 33��� y < S A 0.E3 ' FEi 3 =tY ..•. id aCB �� Yig1�9 3agiy � *o E a = r.,E"°® E;v ge Ea.•:= R 9' AG ! Ci•^ o i �s•*® ,^ _ �` �^ Y as z �k�a?ispiio's ga, /mom PP� OVER .t 'IN 011015 ISONCO y ryERET NMENiALHEALTH ti q m Z lowS— op— `o 2— � P l.o Cl�ce^ m 93" 4oxs 1�,a„lsvA CTSS a ` O Audio-visual m ex Alar ® �y�-, ,,,.� �Q.SENe• ssl+o v C_eanout 5.00 C-a�_ion Pre-Trash tank NuWater 13NR-500 ATU Tanis O _,000 CzIlon Pump Chamber valve Control Box S�rcer Sti eldre�t x�cfi�*3 o-yo" &LS 4� er �przol # 32�os-��-40020 �a Z lodEG�¢+�woo�l7r. row t x s*avjfA Uv iovl VA 95522 "� SIOOJ98 ZS S'0 �� ' b9 PANIA JO Y JOHNS ON . APPROVED ne rcrw , JAN 01 2025 MASON COUNTY ENVIRONMENTAL HEALTH 310 RFT 2 'T'"NsfocIr . ^n / LINE jjsA . I.?•SJoy JO"WN r U, ,yY- DS� C ` o LIMAS GkRDE Detailed Drainfleld Layout pQi41NA� (eQpOF bFF Y . s0 - F• 9��y� � fir Frris • . W b 2•• 1r� APPROVED CIT— '2r '"~ JAN 0 2 2025 rra MASON COUNTY E6'NRQNNF,YTAL HEALTH 1 RET 19"4- a ow" sbF �► tFL. w 'r_ ar ornt'leld_ Gross-Section vlsw w Te terY IIIIF 4N b b OFY b Y F m� astir . FWW FIFO Mort onb ! Fbr. -a..l•br Ilob F ' ONYbrlr M bp1eF Q b Foe of FY La" T�F• ! m Pt. FeF iF= of Tswt To ni" FIFFL FYwAb W � M � a O..m M w. �. . Arrow. Se tWl ptic. Designs W, "" � "°a%' T" � Y M F TMF n (360) 898-2255 � 4�1 � Length Length Orifice # Distance from Distance from Latest# In. Ft. Spacing Orifices Feeder Line In. Cleanout In. 1 360 30 60 6 30 30 2 360 30 60 6 30 30 3 360 30 60 6 30 30 4 360 30 60 6 30 30 5 360 30 60 6 30 30 Total Lateral Lenoth 150 Total#Orifices 30 GPM= 17.7 Dynamic Head Calculations ti D Selected residual pressure: 2 0 c Length(Ft) Orifices (Ft) � n Transport Pipe 80 30 0.47 Feeder Total z /V Lateral Line Length .y N O Lateral#1 30 2 32 6 0.07 ft. z c < Lateral#2 30 7 37 6 0-08 ft. z cNi. Lateral#3 30 12 42 6 0.09 ft. n .M Lateral#4 30 17 47 6 0.10 ft. r Lateral#5 30 22 52 6 0.11 ft. Total Elevation Lift 15.00 fl s Total Dynamic Head 17.92 ft BECURED LID WITH a"TIGHT 8EAL THREADED UN" 24•DIAMETER ACCE88 RISM I Bt�VIDE VALVE' FINMH� '—+TO DRAMFIELD FROM SEPTIC TANK EYEROENCY STORAGE ANTI WHOM VALVE• HIDH WATU ALOW LEVEL INDEPENDEaT WORKING VOLUME FLOAT 9" FOR KORMAL i1 R)OFF LEVEL -- MOUKnNA EMCLOSED PUMP R1ENr SHROUD• CHECK VALVE' 8ED of s' . ._ SUSMONABLE ,? ._------ PUMP _ 510 't' LHAL� PAULF JOYY JO JONNSON'. QyFMGl1 'LkFNSE 'A9 NEEDED � 1WAC chapter 246-2 and FIGURE 2 Septic Tanks must meet standards etlist by registered se"ge tanks. manufacturer must be on Dept Eage 35 of 65 7 WA nrM Ruhlimion#337-022 - • Brame construction available(139 series) High head version available(US series) • Double shaft seal versions available her added protection Flow-Mats on move 1Aa/1A5. For morc informaHan,see Technical Data SheeO FM2782,FM2783. In high head dewatering or effluent applications where pumping q performance is critical, this robust _ E xas,m ala�l'�s.xtlo"] family of pumps is known for reliability, durability and performance. These pumps are especially suited for harsh environments.Zoeller'scoolmndesign and corslon-resisral]t powder coated epoxy finish add up to a long-lasting trouble-free product APPLICATIONS STEP orchids applications w.uxuansfer g. Light commercial dewareing SPECIFICATIONS: 1-1/2-NPT discharge �< 112 HP through 1 HP NAPE IN THE USA • Available in automatic or nonautomatic Ngl&9Rmoutirm Model 137,139,160:lfa•(12 mm)spherical solids capacity Win vortex impeller - • Model US:31e(19 mm)sphedcat solids capacity with ` • —r<. vorteximpeller ']"a r Y PUMP PEflFOfl CURVE MODEL 1 /15P/ 53 Dose-Mateba FGww*ll`-*r N This is our fastest growing Line of effluent H M pumps.The 150series is truly a workhorse designed for reliability under extreme +t N conditions in an effluent environment. 150 series pump curves cover awide range of applications. They are well suited to y ]o applications with Low pressure pipe(LPP) €3 a is] and enhanced ftowSTEP systems.Zoeller's N cool run design and corrosion-resistant N powder coated epoxy finish, in addition a to the heretically,sealed,oil-fiLLed motor rs and non- Logging vortex impeller add up to a Long-lasting,trouble-tree produtt 6 APPLICATIONS: STEP or oosite applications PEP o 6AWI@E&11IUEIISA MHO ]o s u so w N w Light commercial dewatering Y aal]axs n]EaIiICATPNC: IPFRa o •o tl tp ]p M] NO n] ]M a. • 1-1/2•NPT discharge O V C p A P P R D I,'- • 3/10 HP through 112 HP l • Available in nonautomatic or with a variable level JAN 02 2025 piggyback mechanical switch • 1/2-(12mmi spherical soods capacity w1mvortax MASON COUNTY ENVIRONMENTAL HEALTH thermoplasticimpeller For mare I]Iforextion,see Technical Dam Sheet FM2786. RET 0 AU rights reserved. ZOELLER PUMP CO, I502-778.2731180092908671 xoelle]pumps.com 9 brio . . u 4 009 Aso 2» \k\\�31NI SN\a . )11�, ! / �g k§ NU ) / p, Sill ! ) ^ } p\ } [ ail 22�t� � ) ® APPROVE \( � ® ` �'! iƒ § MASON COUNTY ENVIRONMENTAL HEALTH ) wm l f $` a) ` N � t , ■ � l , , a . ; Upz \ )\\ \ 0 ® HEM, ƒ \ { � i / IT � e.r JusersnoN LIovFNihsl � pIMLPgirllEM1YM� RISEIB mP) l 8B•MNL t•PVG(TYP1 eAR1LNE M0.4TIC P r COUPLING a REDICQt 8• r IEE t• .L1,WE IT Fill LINE r PVO TRASH CHAMBER of GPAem 1 1EER CLARIFIER ALLoas pvERATINGpAAstm:4z as QU1MB1A MOOD uAcm: uau PLcooCMACn :xwuiyl ' taCdLLCNa '. aS fa• / \ w• a3• 1 vXE1? ar APPROVED JAN 02 2025 r MASON COUNTYENORONMENTALH UT �I � T�R1ww .• j r - sLwr,E RE1URN 'T'�O I��� ap1E� 1STMfdi 1 MNEEFREENATIVE80IL Gft O IRAOIE08ANO INSTALLATION IHSTRUORONB OVER Shi WIL 1)Excu le lank hole v4lh Vertical wells b 1 foot Wager Ill tank on all sales. 2)If bottom Of hole is stony,inaell r of oomph sans A al M w out screen.. outantank in center aFhoW,keeping tRwid space an r 1r----- -1 as saes. I M.RISEN4,1�vP) arecaxae 4)As tank is filling wfih water,0 in void space wan compact 1 11 ^ I grenular(sanrly)"I free of large dumps of day. 5)Install rest of system,8 affix naers to adapters with / \ watemrcataahesrve. 11 4's• 6)Perfomr wet&E9htnees one in field as required by local I J junsdidion.T)Upon approval to WWII,darefuly backfill with native I I i tr WSER �. I sots overtop of tank. 1 1g 11 p� 19NL6181 8)Final grace the surface w avoid chandling surface L______J L_______JL__J Wa18r trnvara tank I %AEI8 t+i.R w AEROBIC TREATMENT TANK DETAIL FOR Nu WATER BNR-500 TREATMENT UNIT ENVIRO-FLO. INC. -ISEO 3101112 wastewater Treefinenl Tetllnolog)es `�......:wn8 P.O.BOX 321161,Flow .M339232 (8TT)836-8476 (601184+<TS6/ax scu=: www n ' 1" = 1.4 ft. �� Nu Water APPROVED j �'�_ AN 02 2025 j MASON'OU T EWRONMENTALHEALTH A71 M PARTS UST NuWater NR Assembly Diagram A DL PORTAE TOR M-POLY DIFFUSER Bi M B.IV RUBBER W'WI CLAMPS 12) N.1"PVC(3 LY SECTpH) C.Sir BARB TC NPT Z; O. SLIP O.t1SPX VTNPTADAPTR P.1/Y CLEAR PVC HOSE(OPRONAL S) E l'SM.I2 NPT BIS.IeG 0) 0.1/2'PvC PIPE(BY NBTALLEAI F 1?90•ELBOW(3) R.1"PVC PIPE(SY INSTALLER) G.1'X 1'x VT TEE S.T PVC PIPE(BY INSTALLER) H.1'M.ELBOW(3) T.11V BARBEDA PTOR TO Ili'NPT 0 % ? 1-BUSIOKa U.JP'STREET X 10V MPT SUSNING II) J.Y'SANITARY TEE V.1IT PVC COUPLEP.%7) K.1-PVC CROW WS COUPLER(BY INSTALLERS L.1"COUPLER(RYINSTALLER) Revised 2/25/12 ga�ID Clww Se h oet , 9nc. a NuWater BNR Pretreatment %' s INSTALLATION&MAINTENANCE Pressure Distribution Systems PaVIAJOY` OY JO ` HN60N'. C SE ( + 1. Install Laterals with contour of the ground. EVVE$ 2. Install trench bottoms level. 3. Install locator tape or rebar at each end of all drainfield laterals. 4. Install observation ports as indicated on the plot plan. One required at distal end of each lateral in drainfield with bottom extending to the drainrock/native soil interface. Glue "T"to bottom so Observation Port cannot be easily removed from ground. Install removable cap on top of port at final grade level. 5. Install drainfield during dry weather and soil conditions; any soil smearing must be eliminated by hand raking. 6. Install threaded clean-outs at the end of all laterals (cap must extend to within six inches of finished grade and be marked with locator tape or rebar). 7. Install audio/visual high water level alarm. Redundant off switch not required. 8. Install check valve in pump outlet line to prevent system from draining back into the pump chamber. 9. Tee to Tee construction between laterals and manifold with orifices oriented at 6 o'clock. Install laterals to the manifold with the orifices at 12 o'clock,(do not glue), after pressure test and Environmental Health Dept. approval,turn orifices down(6 o'clock)and glue laterals to manifold. Orifice shields may be used with orifices in the 12 o'clock position in lieu of turning the orifices down to the 6 o'clock position. 10.Filter fabric required over drain rock prior to back filling. If the drain rock extends above natural grade,run the filter fabric at least 2 inches down the trench wall. 11. Encase all water lines within 10' of drainfield and under any driveway/parking areas. 12. Divert all storm water runoff away from on-site sewage system. 13.No curtain drains allowed within 10' of the up-slope edge or 30' of the down-slope edge of the drainfield and reserve area. 14.No vehicular traffic over drainfield area. 15.Inspect floats, clean filters,and test high water level alarm every 6-12 months as needed. 16.All materials and workmanship must meet County and State regulations. 17. Deviation from this design without prior approval from the Designer and Mason County Environmental Health Department will make this design null and void. 18. All manhole lids and access, sampling or inspection ports must have locking covers and be located at ground level. 19.All pressure systems with a pump chamber outlet higher than the drainfield must have an anti-siphon valve or a 1/8"hole drilled in the discharge pipe above the pump to prevent siphoning.Ensure anti-siphon hole sprays down/away from tank opening. 20. All transport lines undu driveways or parking areas must be encased to prevent crushing. 21. Homeowner is responsible for all property lines and easements. 22. Please Note: When you begin using your septic system,contact your septic installer to discuss setting up a schedule for your required Operation&Maintenance on your NuWater pretreatment system. APPROVED JAN 0 2 2025 MASON COUNTY ENVIRONMENTAL HEALTH l D a�l O RET