Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2000-00795 Final MFG Home - BLD Permit / Conditions - 11/20/2000
Inspection Line (360)427-7262 MASON COUNTY PERMIT ASSISTANCE CENTER Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 ID, Shelton, WA 98584 � RESIDENTIAL BUILDING PERMIT BLD2000-00795 OWNER: TARA FLEENOR 427-3505 CONTRACTOR: RECEIVED: 06/27/2000 SITE ADDRESS: 70 E JUNO CT SHELTON ISSUED: 0 PARCEL NUMBER: 321347590152 EXPIRES: 02/14/200/14/2001 LEGAL DESCRIPTION: TR 15-B SURV. 2/98 TR B OF SP#2551 PROJECT DESCRIPTION: DIRECTIONS TO SITE: MANUFACTURED HOME HWY 3 TO MASON LAKE RD APPROX 1.5 MILES TO CATFISH LAKE RD TO THE END, LOT 155 LOT ON RIGHT General Information Construction & Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: Type of Use: SF Insp. Area: No. of Bathrooms: Occ, Group: Lot Size: Deck: Type of Work: NEW Fire Dist.: 5 No. of Stories: Occ. Load: Building: Valuation: $53,975 Building Height: Occ. Status: Basement: Manufactured Home Information Setback Information Shoreline& Planning Information Make SKYLINE Length: 38 Ft. Front: W 270.0 Ft, Shoreline: Ft. Water Body: Rear: E 60,0 Ft. Slope: Ft. SEPA?: Model:GREENBRI Width: 28 Ft. Side 1: N 55.0 Ft. Shoreline Desig.: Year:2000 Serial No.: Side 2: S 50.0 Ft. I Comp. Plan Desi .: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty, Type By Date Amount Receipt Mobile Home Submittal KLW 06/27/200 $175.00 53812 ENding State Fee TLG 06/28/200 $4.50 54273 Mobile Home Issuance TLG 06/28/200 $175.00 54273 EtfPlan Review CEW 07/26/200 $50.00 54273 Planning Review Fee KS 07/27/200 $38.00 54273 Total $442.50 BLD2000-00795 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD2000-00795 CONDITIONS FOR BLD2000-00795 1) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. o L X � 1 2) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 3) The approved plot plan is required to be on-site for inspection purposes. If inspection is called for and plot plan is not on site, Approval WILL NOT be granted. In addition, a Re-Inspection fee in the amount of$42.00 per hour(miniM 1 hour) will be charged and must be collected by this department prior to any further inspections being performed or approval granted. X 4) REQUIRED INSPECTIONS (Footing Inspection-prior to pour, Set-up Inspection-prior to skirting, Final Inspection-prior to occupancy). I hereby assume all responsibility for the scheduling of my required inspections. If the required inspections are not requested, inspected and signed off(approved) by the inspector in the prescribed order, I understand that reinspection fees and an hourly investigation fee pursuant to the 1997 UBC, and will be assessed in addition to my original permit fees to resolve any questionable practices or problems that have been discovered. I further understand that this investigation will be scheduled as time allows. Until resolution of aroblems no occupancy (Final Inspection)will be granted for the residence. OWNER/CONTRACTOR(indicate which) Signature X I 5) The installation permit shall be displayed in clear view of the site access road. The approved site plan and other applicable instructions, including installation instructions, shall be available in this location OR placed in the location specified by WAC 296-150M-655. Support configuration shall be clearly marked in the installation instructions. 6) All property lines shall be clearly identified at the time of foundation inspection. X 7) All mobile/manufactured home landings or decks must be freestanding (self supporting). The largest landing or deck allowed without drawings or a building permit MUST be under 30" in height from surrounding grade. NO second story decks, or decks above 30" can be built without a permit. Any landing or deck that is 30" or more in height from walking surface to finish grade requires a Permit. Any landing or deck that has 4 or more risers requires a handrail. X I 8) This applicatiorL is subject to Buffer and Landscaping requirements as established under Mason County Ordinance 1.03.036.X �- BLD2000-00795 Please refer to the following pages for conditions of this permit. 2 of 3 9) The use, handling and storage of hazardoaterials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. X 1 1` 10) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned workwmay affect your project. X 11) Proposed structure or any portion thereof greater than 30" in height frorp4w#de line, must maintain a minimum of 5' setback from all property lines, easements and 10'from all County and State Road right of ways. X_T1 -}- 12) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved befor wilding can be occu °ed. OWNER OR AGENT: A DATE: "-14V ,�^C� BLD2000-00795 Please refer to the following pages for conditions of this permit. 3 of 3 CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas Piping date b I Foundation Walls date b Set Up date by INSULATION date L O —CO by BG/SLAB Insulation Floors Final date by date by date 1 2©-C30 by l FRAMING FIRE DEPT. � date by Walls PLUMBING date by date by Attic OTHER Groundwork date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by 1,0 c7c�✓� � T � s /�y,.J 2 1 O 1 � n o FROM ROBS EXCAVATING FAX NO. 426 6697 Jun. 21 2000l 11:38AM P2 G— f 1 iJ� �Galy I = qo 4 1 i i I 1 � 1 1 1 I 1 ( 1 /so vvyl G )di G AIP -5 APPROVED 1 MASON BUILDING INSPECTOR (� CHANGES SUBJECT TO APP OVAL DATE 1 � 1 l Dom F v:�d tat i i 1 i i i I - 4 ,- - II ,I a PERMIT ASSISTANCE CENTER MEET. ALL CUR E T CHANGES WAariINGT N STATE O ES SUBMIT CHANGES FOR APPROVAL PRIOR TO PERFORMING WORK I THESE PLANS MUST BE A PROVED ON THE JOB SITE MAF UILDING INSPECTOR FOR INSPECTION. U JECT T PROVAL E ...... ....... ....... ...... . ................. W . . ....... U, M. 0 ................... .............. .... ...... .... ..... ............. .......... .......... xm: I M I T E D oof OPTION UTILITY I I I ri 7 W FETI3 f I I vi I 1 111111111-h- 11111 MOO BEDROOM K 1T�' G HEN' No. 2 L . PH� A ',W, Tr: O CA4iDRAI THRU-00 MASTER BEDROOM LIVING ROOM BEDROOM DEN NO. 1 15'-4" No. 3 C1004S 9'.4- 6350CT/3828 3BEDROOM 2BATH§ CATHEDRAL THRU-OUT 11,026 SO.FT.) OPTION DEN Your local &wnbriar&LIMITED dealer is: INS BRINGING AMIKA HOME.BRINGING Amu FUN. ............ 28. Fr. Ycelb fi, L I M I T E D e-2immq-Amas Addwinal Features • Carpet • UL Classification &Inspection • Valance w/Mini Blinds • 25-Year Shingles (Fiberglass—Class A • Dining Light Fire Rated) • Fiber-Cement Siding Cgitchen • Cathedral Ceiling Throughout • Raised Panel Cabinet Doors w/Hardware • Upgrade Passage Door Moldings, • Drawer Over Door Base Cabinet Construction Prefinished Jambs & Hinges • Side Roller Drawer Guides • 5/8"Textured Ceiling w/Knockdown Ceiling • Black Toe Kick • Linoleum at Entry • Lined Overhead Cabinets • Carpet in Hall • Stainless Steel Sink w/Single Lever Faucet • 3/8" Rebond Carpet Pad • 14 Cu. Ft. Double Door Frost Free • Electric Furnace Refrigerator • Graduated Fiberglass Heat Ducts • 30" Electric Range w/Lighted Power Hood • 30 Gal. Electric Water Heater • Pantry per Floor Plan • Water Shut Off Valves,All Fixtures • Plumb for Washer OYathrvmr • Wire for Dryer • Decorative Mirror • Overhead Cabinet at Washer/Dryer Area • Privacy Locks • Delta Fixtures Throughout • Single Lever Faucet at Lav • Metal Door Knobs • Raised Panel Cabinet Doors w/Hardware • 6 Panel Steel Front& Rear Door w/Deadbolts • Paper Holder • Insulated Low"E"Vinyl Windows • Linen Closet in Master Bath per Plan • Egress Windows in Bedrooms • Power Vent Fan • 200 Amp Service Entrance • 7' -6"Sidewall Height O�edra6�ns • 2 x 6 Sidewalls, 16" O.C. • Carpet • 2 x 6 Floor Joists, 16" O.C. q • Valance w/Mini Blinds • Detachable Hitches • Walk-in Closet per Floor Plan • Copper Wiring :j • Ventilated Wire Shelving • Smoke Detector • Exterior Receptacle w/GFI Breaker • Electrical Breaker Box ��pssrF��o • Exterior Light at All Exterior Doors d UL $"LON, • Code Insulation (R-19 Floor, R-19 Walls &R-19 Ceiling) The Higher the"R-Value"the ULClassified —® Greater the Insulating Power as conformin � to the Federal Manufa tured Home BRINGING Awn HOME BRINGING Amu FUN. N (0 M For your comfort and safety,Skyline home designs are approved and each home is inspected by Underwriters Laboratories for conformance to Federal standards. M 0 Dimensions stated to industry standards.Width and length dimensions are nominal and are not to be used for setup of home on site;consult selling retailers for exact specifica- O) tions.Overall length does not include approximately four foot hitch.The square footage is approximate and based upon nominal exterior floor size.Room sizes are measured from 6 floor ends and wall centers. N Because of progressive product improvement,all prices&specifications are subject to change without prior notice or obligation to Skyline Corporation.