Loading...
HomeMy WebLinkAboutAssessment of Pre-Fabricated Bridge - BLD Engineering / Geo-tech Reports - 4/17/2008 Apr 22 08 02: 23p Joel Ne�hart 2066235111 p. 2 Envirotech Engineering April 17, 2008 74 NE Hurd Road, Doug Neyhart Belfair, WA 98528 2297 Tahuya River Road Tahuya, Washington Reference: Assessment of Pre-Fabricated Bridge to be Located at 2297 Tahuya River Road in Tahuya, Washington Dear Mr. Neyhart, Envirotech Engineering (Envirotech) completed this assessment of a former flat car to be used as a bridge for the referenced property. The bridge is a total of 89 feet in length and 13 feet wide, and will be placed on the abutments that span approximately 81.3 feet. The bridge consists of a composite wood decking with steel under-structure. Two main steel stringers of 18 inches in depth run the entire length of the bridge. Additional steel bracing required for bending moment and lateral capacity spans about 1/2 the bridge length, and is located in the center of the prefabricated structure. The bridge is reported by the distributor to have a 125,000 pound load capacity. Please see the 5 attachments to this letter with relation to capacity, profile and bridge components. The owner provided all load capacity, fabrication and bridge span information. Envirotech will field verify the provided information after the bridge is delivered. Based on all provided information, expected bridge parameters, and abutment design, it is our opinion that the new bridge will accommodate a vehicle gross weight of 45,000 pounds. Envirotech is pleased to submit this engineering assessment. If you have any questions or need additional information, please contact Michael Staten at 360-275-9374. Best Regards, Envirotech Engineering cLYnEsT V'AS43045 lf�� Fssrcv.ac.ENG EXPIRES JAN 10,2009 Michael Staten Project Manager OFFICE: 360-275-9374 CELL: 360-689-6045 FAX: 360-275-4789 EMAIL: envirotech@geotechnicalinfo.com Apr 22 08 02: 23p Joel Neyhart 2066235111 p. 3 ATTACHMENTS 1. Load Capacity from Rick Franklin Corporation 2.Profile and Plan View 3. Bridge Side View 4. Bridge End View 5. Bridge Top View Apr 22 08 02: 24p Joel Ne�jhart 2066235111 p. 4 i—- i From: 0212.71290A Rick Franklin i Corporation ' 101 Industrial Way - P.O_ BOX 365 Lebanon, OR 9.7355 (541) 451-1275 Fax; 258-6444 FLAT CARS . . . . . . . . . . THE BETTER BRIDGE ■ Cost Effective ■ Easy Installation 1 Long Lifetime ■ Low Maintenance i ■ Permanent or Portable I RFC Flatcar Inventory 44' $7,000 44'6"x 9`6' Flat Steel Deck (No Curbs) Heavy Duty 4 g' $4.500 48'x 8'Wood Deck 50.404#Load Capacity 53' $9,000 DRGW Series 53'x 10,60. 147,000# Load Capacity UP Series 53`x 1016" 140.000#Load Capacity ( 56' $10.000 DWC 3erie�s 165,00041 Load Capacity `�,:35 SOU Series 5&'x 10' 184,900#Lard Capacity �93�13'c 'x 60' $10,000 ATSF SEtiE35 W x 1016• 148,000#Load Capacay BN Series 60'x IV 6` 150 000#Load 7 fdooa 'x 9 / ,�ec Capacity 69' $15,000 ATSF Series 89 x 9'6'Rat Steel Deck (No C4rb6 UP Series . $9 x 8'6' (Nth Curbs). J \\ 125,000#Load Caps / i $rN to Ab(/bymw a'X V x-1 5.320# E'dCifi if you have any questions, pllease call- John Ig. Flatcar Salea Representative Elmo UN MEMO sommom M 0 0 C:CmIIiCE�T.::a��ll MENNNE MINE Is mommommoll -- MEMERISM, namm OMEN no miltal NMI NONE M ME mom 1No IBmooloo NONE mom JIM NMI 11 NMI MOEN �I ! EmNomO IifffijNfw Mman Ii lIlIII11 IOM EE WE on I Elm � I MENEM MEN ism INN eaICS: l 00 Apr 22 08 02: 24p Joel Neyhart 2066235111 p. 6 _-.___._..w.•_-. ,._ ^_ ^fir- - �,,. ..__'. •.__J_- .-_!._�r-..._ - ..-..___ - ..... _.. _.- __. _ . 1 �� t NA i L-7 T' Apr 22 08 02: 25p Joel Neyhart 20G6235111 p. 7 i ---- --..- _-- - PI Apr 22 08 02: 25p Joel Neyhart 2066235111 p. 8 � — ��.� t _ — __ _ --. .._ •_.. _. ._ —' -'� —. —_ ..—. .. .ram _._; _— '-•— ...-1 —.. .. .. -- • t ' � i x • _� _ !, --� _ �---�, —• /y��� - _. ._ i._. _.__y _ems_ _.1 _—.._ _— .--•. _'._ ..._ .'..-. ._ ..