Loading...
HomeMy WebLinkAboutBLD28838 Final SFR - BLD Permit / Conditions - 12/21/1991 Shorelines: Plumbing:,q C /o-9- y�j �,-y Setback: MechanicalZ)e Special Interior: Conditions: FINAL: dC I,,-? Mobile Hcme: Smoke Detector: Remarks: oot ing• 2& Setback:,t},e Foundation Walls: , f Framing:ok 1O-G; / r°�rvT1 - — Fireplace: F.7-q 1 Wood Stove: TYPE RESIDENCE Permit No. 28838 No. Floors 2 Sq Ftg1708 Owner Shelton Const. Te]426-1600 Date 19 91 Address E 1451 Anthony Rd Grapeview Zip Contractor Same Address Zip Legal Description 34 21 3 Lot 59 Rainbow Lake Direction to project site Hwy 3 to Mason Lake Rd--Left to Rainbow Dr--Left to 7th lot on left. um ing x Mechanical _ ewer WoodStove Fireplace Deck Garage _,, -7arport Basement soft Other BUILDING PERMIT APPLICATION ') MASON COUNTY V DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 G 427-9670 DATE ISSUED I ` PERMIT NO. v � OWNER NAME MAILADDRESS CITY&STATE ZIP PHONE S �� .1 d -s G a / tld DIRECTIONS TO JOB SITE tp �� DA/ v //V`Js tyi ©Q ✓P ' L P�T �17 PARCEL LEGAL NUMBER ��3y-SO-OvaS�j DESCR. NAME MAILADDRESS CITY&STATE LICENSE NO. ZIP PHONE CONTRACTOR 10 C p USE OF BUILDING S CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE WORK r 1/ DESCRIBE WORK Ale c,, ' p BEDROOMS ? DECKS CARPORT NOTICE SEPARATE PERMITS ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR �O BATHROOMS 2 TOTAL SQ.FT. GARAGE 2, CONDITIONING. NO.OF STORIES __2_ BASEMENT L2 15 ATTACHED __X_ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 SAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR TOTAL SQ.FT. 9 FO_ FIREPLACE DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. PERMANENT SHORELINE SEASONAL OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND i AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT. 1 X OWNER DATE X BY A�U z I DATE FOR OFFICE USE ONLY DEPARTMENT APPROVED DEPARTMENT APPROVED BUILDING VALUATION YES NO YES NO HEALTH Q0V_ PUBLIC WORKS FEE PLANNING FIRE BUILDING PERMIT D.O.T. BUILDING PLAN CHECK SPECIAL CONDITIONS BUILDINGGROUP r3 rn_� PRE-INSPECTION SHORELINE WOODSTOVE PLUMBING MECHANICAL / STATE BUILDING FEE STATE SURCHARGE APPLICATION A CEPTED BY PLANS CHECK BY APR VIED R ISSUANCE PERMIT VALIDATION `, 1 �� - ��9 B CASH CK MO TOTAL (J/� PLUMBING & MECHANICAL PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 427-9670 DATE ISSUED Q PERMIT NO. OWNER NAME MAIL ADDRESS CITY&STATE ZIP PHONE n/ t/ S N v. dV, 6 P!//N f/q 7S`f Z L PO DIRECTONS TO OBIS Cr/TE 1� /� sO/✓ /C/�yG/ L P T/ 7 /4/�f/Qtr�(! /r P 7 l T t' LEGAL r DESCR. J �� Lz/ L CONTRACTOR NAME MAILADDRESS CITY STATE LICENSE NO. ZIP PHONE �TC 2 o�'T USE OF p BUILDING PLUMBING FIXTURES MECHANICAL FIXTURES NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE Z WATER CLOSETS FORCED-AIR/GRAVITY TYPE FURNACE 6.00 3 BASINS FLOOR/SUSPENDED FURNACE 6.00 BATHTUBS L BOILER/COMPRESSOR 6.00 SHOWERS REPAIR/ALTERATION 6.00 WATER HEATERS _ REFRIGERATION COMPRESSOR SYSTEM 6.00 AUTO.WASHER AIR HANDLING UNITS 7.50 SINKS HEAT-PUMPS 6.00 FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET DRINKING FOUNTAINS VENT.FAN SYS.3.00 PER UNIT LAUNDRY TRAYS WOOD STOVES 5.00 CONNECT TO CITY SEWER WOOD FURNACE 5.00 DISHWASHER DISPOSAL URINALS PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00 TOTAL TOTAL SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT I AM A CURRENTLY REGISTERED THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL 8E IrjCONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT MTOBTAINI APPAL FROM THE BUILDING DEPARTMENT. X OWNER DATE X BY ' DATE FOR OFFICE USE O LY APPLICATION ACCEPTED BY PLANS CHECK BY BUILDING GROUP / APPR D F ISSU N E PERMIT VALIDATION `-I BY CASH CK MO BUILDING PERMIT PLOT PLAN MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. Box 186 SHELTON, WASHINGTON 98584 427-9670 DATE ISSUED PERMIT NO. NAME MAIL ADDRESS CITY&STATE ZIP PHONE OWNER f �• �/ ,,, �o.v G' c `��SY 1/� "-/6au DIRECTIONS / 1 1 TO JOB SITE J ' �v U/t L �1 f �'• P / a /v n d l lv[' ` 1 4/` 4-0 7-a /o oy PARCEL LEGAL NUMBER DESCR. �a J�•S r ��/R/601c/ .�9 �2" Indicate below: O Property lines and dimensions. O Easements and roads. O Septic, drainfield and reserve area, or sewer. O Septic tank and drainfield setback distances from foundations. O Location of proposed construction on property. O Building & septic system setback distances from all property lines& easements. Indicate North O Well and water line. In Circle O Saltwater, lakes, rivers, streams, wetlands, drainage. O Attach copy of septic system"as built" or septic permit approval. O Indicate topography profile of property and structure on reverse side. Y ' 4, 61 I/We certify that the proposed construction will conform to the dimensions and uses shown above and that no changes will be made without first obtaining approval. :\C, i g SIGNATURE OF OWNS S)OR AUTHORIZED REPRESENTATIVE DO NOT WRITE BELOW THIS LINEZ DISTRICT AS NOTED DATE TOPOGRAPHY PROFILE OF PROPERTY AND LOCATION OF STRUCTURE WATTSUN 5 . 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 07/19/91 BILE: C: \WATTSUN5\SGC1172 .WS HOUSE ID: SGC1172 Site: LOT 59 RAINBOW LAKE Analyst: BELLY BUECHEL SHELTON, WA Jurisdiction: MASON COUNTY Utility: MASON COUNTY PUD #3 Homeowner: SHELTON CONTRUCTION Mail : Floor Area: 1713 ft2 Builder: SHELTON CONSTRUCTION Weather Data: Olympia, WA Address: Climate Zone: 1 The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 298 288 Btu/hr-F ; ENERGY BUDGET 3 .97 4 . 05 kWh/ft2-yr REFERENCE DESIGN Reference Component Value X Area = UA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BG Wall U-0 .041 207 8 . 5 BG Slab F-0 .640 59ft 37.8 On Grade Slab F-0. 540 59ft 31 . 9 Floor U-0. 029 28 0 . 8 Glazing @15% U-0. 400 257 .0 102 . 8 Doors U-0. 200 42 . 0 8. 4 AG Wall U-0. 058 1382 80. 2 Skylights U-0 . 031 8 .0 0 . 2 Ceiling U-0 . 031 873 27 . 1 Infiltration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Reference UA 298 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BG Wall R11 batt 3 . 5 ' depth U-0 . 062 207 12 .8 BG Slab F-0 . 630 59ft 37 . 2 On Grade Slab RO Uninsulated F-0 . 730 59ft 43 . 1 Floor R25 vented Joist 16oc U-0. 034 28 1 .0 Glazing @11 % **XO W/AR U-0 . 370 126 . 0 46 .6 **MILGARD VINYL PATIO W/AR U-0 . 480 35 .0 16 . 8 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Items in parentheses not included in COMPONENT PERFORMANCE totals . ** Denotes non-standard values - check calculation of thermal value. Page 1