Loading...
HomeMy WebLinkAboutBLD2024-01388 Roof Solar - BLD Inspections - 12/23/2024 INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 ��� www.masoncountywa.gov �gw PERMIT# BLD2024-01388 PROJECT ADDRESS 401 E BENSON RIDGE RD GRAPEVIEW, WA 98546 PARCEL# 221044350200 PROJECT DESCRIPTION Addition of 10 Solar panels to existing solar OWNER NELSON JAN A&CONNIE J ADDRESS PO BOX 195 PHONE 253-302-9012 CONTRACTOR SOUTH SOUND SOLAR INC ADDRESS 4511 LEMON RD NE PHONE 360.352.7869 CONTRACTOR LICENSE SOUTHSS902N7 LENDER INSPECTION INSP DATE Comments INSPECTION INSP I DATE Comments BLD-Final Inspection -; Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FBLD202,4-01388 ROOF MOUNT SOLAR PANEL- RESIDENTIAL ESCRIPTION: ADDITION OF 10 SOLAR PANELS TO ISSUED: 12/05/2024 OLAR ESS: 401 E BENSON RIDGE RD GRAPEVIEW EXPIRES: 06/03/2025 PARCEL: 221044350200 APPLICANT: NELSON JAN A&CONNIE J OWNER: NELSON JAN A&CONNIE J PO BOX 195 PO BOX 195 WAUNA,WA 98395 WAUNA,WA 98395 253-302-9012 CONTRACTOR: South Sound Solar 4511 Lemon Rd NEOlympia,WA 98506 3603527869 GENERAL CONTRACTOR'S LICENSE: SOUTH SOUND SOLAR INC License: SOUTHSS902N7 4511 LEMON RD NEOLYMPIA,WA 98506 Expires: 0 812 7/2 0 2 6 360.352.7869 FEES: Paid Due State Fee-Residential $6.50 $0.00 Solar/PV Fee $190.00 $0.00 Solar/PV Base Fee $30.00 $0.00 Final Inspection $97.00 $0.00 Technology Surcharge $1.94 $0.00 Totals : $325.44 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection CONDITIONS Printed by:Brittany King on:12/20/2024 02:36 PM Page 1 of 4 Mason County Mason County - Division of Community Development 615 W. Alder St. tf.. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-01388 The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org ... ...... . " All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. " Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. Printed by:Brittany King on:12/20/2024 02:36 PM Page 2 of 4 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-01388 The installation of solar(thermal or photovoltaic)energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 4 Ibs per square foot. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two- 3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any gther state/ocal law regulating construction or the performance of construction. Issued ( rs Contractor or Authorized Agent: Date: Printed by:Brittany King on:12/20/2024 02:36 PM Page 3 of 4 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-01388 Printed by:Brittany King on:12/20/2024 02:36 PM Page 4 of 4 Jan Nelson ROOF SPECS: 401 Benson Ridge Road SLOPE 7:12 Grapeview,WA 98546 TYPE SSM EXPANSION s18.3° (253)302-9012 Array Mounting:SM/SNR ARRAY jan.nelson@outlook.com S-5!SorU O 0 0 0 0 C? 0 0 Sales: Chad Brundage ARRAY FP=945 MC! LOAD=2.63 psf h, i DATE:11/18/2024 DRAWN BY:AB U IU 0 0 0 0 u 0 O 0 1-LINE DIAGRAM VERSION 1 I SOUTH SOUND SOLAR UTILITY:MC PUD3 360.352.7869 q p q q 0 1 q 0 CCB#SOUTHSS902N7 AHJ:LNI MASON CO EXPANSION SYSTEM SPECS. 10)SIFAB 420 BG MODULES-4.2 kW(S.T.C.) MCI MAX POWER:420 WATTS O O 0 0 0 0 0 O Vmp=38.51 VDC-Imp=10.91A O O O O 0 0 Voc=46.36 VDC-Isc=11.4A p, EXISTING SYSTEM SPECS: 35)SILFAB 410 BG MODULES• 14.35 kW(S.T.C.) MAX POWER:410 WATTS Vmp=38.07 VDC-Imp=10.77 A (6)#10 THHN HHN Voc•45.02 VDC-Isc-11.35 A W/#10 EG LOCATED IN 3/4"EMT-—— #2/3c NM-B IN 3/4"EMT LOCATED EXTERIOR W/#10 EG G#8 E—� W/ --- COMBINED ARRAYS=18.55 kW(S.T.C.) EXTERIOR EACH-———————— ON BLDG W/SOLAR uuE METER/DISCONNECT I I 13-4)TESLA SOLAR SHUTDOWN DEVICE MCl/RSD 2ooA Bus I I TESLA MAX Isc-15A NET 21 3R ! I 7.6kW INVERTER (1)DEVICE PER(3)SOLAR MODULES MAX METE 2P 200A MCB I LOCATED EXTERIOR LOCATED EXTERIOR I •'4• LOCATED INTERIOR ! ON BLDG W/SOLAR ON BLDG W/SOLAR 2)TESLA SOLAR INVERTER 7.6kW 0A0 GARAGE I r _ MAX OUTPUT POWER•7,680VA ! DISCONNECT/RSD COMBINER PANEL MAIN PANEL 2P 3R BOA FUSED MAX OUTPUT CURRENT=32A @ 240 VAC SQUARE D GO LOCKABLE 2P IOOA 3R I MPPT VOLTAGE RANGE=60-48OVDC KNIFE OPERATOR MAXIMUM INPUT VOLTAGE-60OVDC 200A BUS RATING I MAXIMUM Isc PER MPPT•17A LOAD SIDE TAP I 200A TOTAL MAX OUTPUT CURRENT=64A M.C.B. I DERATED=BOA,BOA OCPD I I MOUNTING SPECS BLACK PV Module(SIL-420 BG) i TESLA f'--�5 SNR RAILS/168"ea _J_ 2P 40A 7.6kW INVERTER © 4 SNR SPLICES Dimensions: 2P 40A 73.4"L x 40.5"W Jot O 16 L FEET ATTACHMENTS Long Edge Primary Mounting U16 SNR RAIL Zone: ATTACHMENTS 10.1"-14.0" —O 4 SNR GROUND LUGS (3)#4 THHN Long Edge Secondary Mounting INVERTER"A" INVERTER"B" W/#8 EG DC 8 SNR END CLAMPS Zone: STRING DETAILS STRING DETAILS IN 1"EMT I 5.2"-10.1" MPPT 1: 7 MODULES MPPT 1: 7 MODULES (6)#10 THHN ! 16 SNR MID CLAMPS MPPT 2: 7 MODULES MPPT 2: 7 MODULES W/#10 EG 0 SNR MICRO HW Short Edge Mounting Zone: MPPT 3: 7 MODULES MPPT 3:10 MODULES IN 3/4"EMT 7.9"-9.8" MPPT 4: 0 MODULES MPPT 4: 0 MODULES (2 SPARE FOR EXPANSION) --- 16 S-51 S or U CLAMPS :. X 1::f 'nverter 153800C)-45-A--GF2231290C�3438/ Power MPPT X Power MPPT B. Power MPPT C, Power POPPT D ADD EXPANSION STRING TO THIS INVERTER i$SA. w Fc r Nam` 9 1.8 kW -•--..... .... ........... .-..---•----- 18kW 14kW 1.2kW 1kW 800 W 600 W 400 4Vo .k 200 Nl 0 w mower IIPP7 0 12:00 15:00 i$:00 21:00 Nov 17,2024 4. a ADU22322KC1DUZ/Power MPPT A w ADU22322K=22/Pcwer MPPT 5 w ADU22322000221'Po-wer MPPT C 0 AiDU22322,000221'Pmer MPPT 0 tQ L R £ P ff + II{� s`-t�a yf 1 s I� t I I I 1 ., . AO0 UPPER PLAN /ROOF ARRAY LAYOUT, NELSON 2023 4" -------- ---------- --- TIGHT FIT,MEASURE CAREFULLY-CALL KIRK W1 QUESTIONS L. i L CL Lu "Al CL . CL SITE PHOTOS NELSON 2023 AFF PREWIRED FOR DISCONNEC /S ST a 1 J F' y 4 ` Cz pp , hY a. til� n W+ __r� . - w t { i < a JJ' f 07, LOOKS LIKE WE USED S5 N 1.5 47N r .,,;.:•�.: ,� ��,.t .. . ,�, .._.�_� �.. —�,------.e—.mom-�,.-._- - —�a� __- .�.. - TESLA INVERTER INSTALL DETAILS INSTALL OPTIONAL SYSTEM SHUTDOWN SWITCH The Solar Inverter can to wired to a System Shutdown Switch that manually disables the inverter,When the 7.6 kW Install Site Ener (Solar Onl Sit System Shutdown.circuit is opened,the AC relay internal to the Solar Inverter is opened,thus disabling Solar SY Meterin g y 25) Inverter output.The System Shutdown Switch Is wired through a low voltage.12 V DC.I A control circuit Up to Four Independent Strings' connected to the Solar Inverter RSD ports Note: Skip this step for systems nstolled with?owenvall To install the System Shutdown Switch. Option A:Use Factory-Installed Neurlo Meter(1538000-45-y Only) 1 Remove the factory-installed jumper from the RSD IN/RSD Out ports.See Aooendix B.Wwrnc Reference on pago 85 for a detailed wiring reference. L1 (CT4) L1L2 _ War Inverter , ny-Installed---� --- _ a OWONW CidN dra.r NWb Meter - ift a'v'wr.o - - L2 (CT3) Lt se I: pit �. 1� t ' MM 2. Using minimum 24 AWG conductors,with wiring methods according to code,connect the RSD ports to a suitable DC switch(requirements below) Flat PV Modules --- 5, �1111 R I�lil�li^M�Y� NM Or AUXILIARY CONTACT ON SIDE OF DISCONNECT 9 1 13 21 MCI � MCI 14 22 • o War Inverter F:CI Q w V JF W DISCONNECT TERMINALS LIFT OUT OF ENCLOSURE FOR EASE OF WIRING, 1 MCI for every 3 modules 'z PULL BLUE TAB ON UNDERSIDE DOWN W/SCREWDRIVER BLADE &TILT OUT DISCONNECT PN ML1-025V-EO1R,MFR MERZ,600VDC,25A,UL508 OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the requirements listed in this Checklist.All project plans and supporting documentation must be provided on site for the inspector. --------TO BE COMPLETED BY APPLICANT------- ® Project Information Property Owner Name: Jan Nelson Project Address: Parcel# 401 E Benson Ridge Rd City: State. ZIP: Grapeview WA 98546 Day Phone: 253-302-9012 Contractor Name South Sound Solar Contractor License#: Southss902n7 Contractor day phone: 360-352-7869 Describe project: Conventional framed built dwelling or garage, Pole structure,steel building,etc. Note: Manufactured/mobile homes require L&I Approval PV system description Addition of 10 Silfab panels to existing solar array (include manufacturer and model#of PV modules and inverters): ®Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that El ❑ is code compliant to setbacks and height, or code allows expansion of nonconformity for solar modules. [IRC 101.2] 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by El ❑ the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, E1 ❑ metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] E1 ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to 0 ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended 0 ❑ by WA State. [IRC M2302.2] 7. The PV system is designed for the wind speed of the local area, and will be installed per ❑ the manufacturer's specifications. [IRC M2302.2.1(1)] 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] 0 ❑ 9. Total dead load of modules, supports, mountings, raceways and all other appurtenances 0 ❑ weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] 1 Enter total dead load of system (lbs/ftz): Click here to enter text. 10. To address uplift,modules are mounted no higher than 18" above the surface of the ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty(50) pounds. ❑p ❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for IZI ❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, ❑ rodents,and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. 0 ❑ [IRC M2302.2.3] Comments: If you answered yes to all of the above questions,the project qualifies for the over-the- counter permitting process. Q Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] yAs the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: Agelo.� i64%rZ7 Date: 11/22/2024 Applicant Name(Please Print): ROSIe Rumsey --------TO BE COMPLETED BY MASON COUNTY STAFF------ Qualifies for OTC Building Permit? ❑Yes ❑No Permit Application#: Staff Initials Date: !( 2 MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: •BUILDING •PLANNING •FIRE MARSHAL 615 W. Alder St- Shelton, WA 98584 www.co.masonma.us Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 Phone Belfair:(360)275-4467• Phone Elma:(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Jane Nelson NAME:South Sound Solar MAILING ADDRESS:401 E Benson Ridge Rd MAILING ADDRESS:4511 Lemon Rd NE CITY:Grapeview STATE:wA ZIP:98546 CITY:owpia STATE:wA ZIP:98506 1 st PHONE:253-302-9012 PHONE:360-352-7869 CELL: 2nd PHONE: EMAIL :Rosie@soulhsoundsolar.com EMAIL:jan.nelson@outlook.com L&I REG#60s-006-$50 EXP. 08 /27 /27 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):221044350200 Zoning: LEGAL DESCRIPTION(Abbreviated): SITE ADDRESS: CITY: DIRECTIONS TO SITE ADDRESS: TYPE OF JOB: NEW=ADD=ALT=REPAIR=OTHER=USE OF BUILDING LOCATION OF FIXTURES/UNITS—I ST FLOOR=2ND FLOOR=BASEMENT=GARAGE=OTHER=✓ PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric=LPG=Natural Gas=Ductless= Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel x Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X /epdz�' h 11/22/2024 Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN Fire pathway ID n AH1 Mason County Code year 2021 Washington State —— Fire Code Roof pane!coverage _ 36 o f Width 36 in { V W The Right Way! UL r MiERi� S-5-PV Kit and EdgeGrabTM LISTED The concept of combining photovoltaic arrays with standing seam metal roofing is growing—and for good reasons.A standing seam metal roof has a life expectancy consistent with that of framed > PV modules.A 30-year power source on a 40-year roof,along with zero-penetration technology, a creates the most sustainable roof system available with alternative power generation,all without compromising the roof manufacturer's warranty! LO The new S-5-PV Kit boasts an important breakthrough in PV mounting technology.It is one of (� the first solar module mounting solutions in the industry to be listed to the new UL subject 2703, OO a standard that covers both bonding and mounting.Furthermore,the S-5!'Mounting Disk has L gained an ETL Listing to UL 1703.* The S-5-PV Kit features a groundbreaking new stainless steel mounting disk with twelve nodes }' designed to ensure the module-to-module conductivity of anodized aluminum module frames. This means it automatically provides a ground path in the module frame. No lugs or wire required E except to connect one string of modules to another and to ground the system.This connection O detail represents installed electrical cost savings of$6-$12 per unit.In most cases,the savings in time and materials is sufficient to pay for the entire S-5-PV Kit and clamp setup. t s i .a —.>:..r� . i >1 M M COCO The S-5-PV Kit is a revolutionary new solutionto attach solarpanels to standing seam metal roofs! RightThe S5PV Kit 0.47•, The 5-5-P - - V Kit is furnished with the hardware shown at (1 z.00 mm) right,excluding the attachment clamp,which is supplied (UL and ETL Listed) separately.(When ProteaBracket—is used in conjunction with 1.50" the S-5-PV Kit,an additional nut is required during installation (38.00 mm) to secure the universal PV stud and mounting disk to 1.001• 0.87" ProteaBracket's slotted L-flange.)The S-5-PV Kit is compatible (25.00 m ) (22.00 mm) with most common metal roofing materials,including brass. 0.71" The S-5!®EdgeGrab—and S-5-PV Kit together accommodate 3.00" (18.00 rr m) (76.00 mm) Ir PV frame thicknesses 30-48 mm(if EdgeGrab's serrated ETL Listed L-flange is positioned below the stud's hex nut)and 34-51 Mounting Disc Friction Reducing Stumm(if Ed eGrab's serrated L-flan a is positioned above the Height Coated Stainless Steel 9 9 p Height Universal PV Stud w/ stud's hex nut)? 2.67" M8 Integral Hex Nut The embossed panel guide makes the module placement easier. (68.00 mm) Module Placement Bevel Guide The mounting disk is multi-directional and rails are not required. Wire zip Tie Slots Four strategically placed under-disk hooks assist in wire management.The PV grab ears that hold the solar panel in place are broader to allow for ease of installation and precise 0.06" Wire module engagement. (1.50 mm) Management Hooks Accommodating module thicknesses between 30 and 51 Please Note mm,the S-5-PV Kit fits the majority of solar panels on the Dimensions of both the market.Using the S-5!mini clamps,it fits most standing Universal PV Stud and seam metal roofs.When aired with other S-5!products,the the Mounting Disk are S-51 clamp not included. p p identical between these S-5-PV Kit and EdgeGrab will work on most exposed-fastened two illustrations. and corrugated metal roofs.The standard grab is designed o.48 (12.19 mm) to fit field conditions(two adjacent panels),while the new .. EdgeGrab is designed specifically for end conditions. EdgeGrab TM (Not UL or ETL Listed) 1 Wind dynamics are complex;thus,each system should be reviewed by a qualified licensed professional who 0.84" � Hold Min/Max understands wind effects on metal roof design and (21.34 mm) 1.18•'-1.89'• construction prior to purchase and installation.For more 1.50" ---s (30.00-48.00 mm) detailed information including specifications,installation (38.10 mm) instructions,and CAD drawings,visit www.5-5.com or your S-5-13V Kit distributor. The easiest Kit continues ec be iv c •" the easiest,most cost-effective f\[IT�'/i way to install solar panels directly \ Please note:The �_ 2.00" — to standingseam metal roofs, LISTED assembly option in the roo diagram to the right (50.80 Inm) remaining the most popular Listed to UL subject 2703. illustrates the serrated choice worldwide. ETL Listed to UL 1703* L-flange positioned below the stud's hex nut. S-51 clamp not included. Please note:All measurements are rounded to the second decimal place. *Patents pending.Certain components featured in - illustration may not be UL listed. ID Due to the variety of attachment needs,S-5-PV Kits are ® sold separately from S-5!mini clamps.The S-5-PV Kit fits onlyS-5!mini clamps,NOT standard clamps. 5-5!*Warning!Please use this product responsibly! Distributed by Products are protected by multiple U.S.and foreign patents.visit the website at www.S-5.com for complete information on patents and trademarks.For maximum holding strength,setscrews should be tensioned and re-tensioned as the seam material compresses.Clamp setscrew tension should be verified using a calibrated torque wrench between 160and 180Inch pounds when used on 22ga steel, and between 130and 150 inch pounds for all other metals and thinner gauges of steel.Consult the S-5! website at www.S-5.com for published data regarding holding strength. Copyright 2014,Metal Roof Innovations,Ltd.S-51 products are patent protected. S-5'aggressively protects its patents,trademarks,and copyrights.Version 032714. ELITE SI LFAB S O L A R NOT JUST ANOTHER SOLAR PANEL . Back-contact technology with an innovative conductive backsheet and integrated cell design delivers the highest performance, PERFORMANCE durability and beautiful aesthetics. Manufactured exclusively in the United States. LFABSOLAR.COM CE 0 0% 1EC iWieik ELECTRICAL SPECIFICATIONS 420 Test Conditions STC NOCT Module Power(Pmax) Wp 420 313 ------------------------ Maximum power voltage(Vpmax) V 38.51 35.89 Maximum power current(Ipmax) A 10.91 8.73 ---------- ... _w._.._...._-__.-_.__.-__.-.....---._--._._-...__...__-___._- Open circuit voltage(Voc) V 46.36 43.45 Short circuitcurrent(Isc) A 11.4 9.18 Module efficiency % 21.9% 20.4% - Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance WP 0 to+10 Measurement conditions:STC 1000 W/m2-AM 1.5•Temperature 25°C•NOCT 800 W/m2•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+low. MECHANICAL PROPERTIES/COMPONENTS METRIC IMPERIAL Module weight 20.&':0.2 - 45.8±0.4 lbs Dimensions(H x L x D) 1864 mm x 1029 mm x 35 mm 73.4 in x 40.5 in x 1.4 in Maximum surface load(wind/snow)' 5400 Pa rear load/5400 Pa front load 112.8 Ib/ft'rear load/112.8lb/ft2 front load Hail impact resistance o 25 mm at 83 km/h o 1 in at 51.6 mph Cells 66high-efficiency mono-PERCMWTc-Slcells 66high-efficiency mono-PERCMWTc-Slcells 166x166mm 6.53x6.53in _-._-_._._ Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, anti-reflective coating anti-reflective coating Cables and connectors(refer to installation manual) 1200 mm o5.7 mm,MC4 from Staubli 47.2 in,o0.22(12AWG),MC4 from Staubli Backsheet Multilayer,integrated insulation film and electrically conductive backsheet,superior hydrolysis and UV resistance,fluorine- free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Amc+.ion Box UL3730 Certified,IEC 62790 Certified,IP67 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient Isc +0.046%/°C Module product workmanship warranty 25 years** _- ___..----------___..__._--__....--__.-_______-__-._ Temperature Coefficient Voc -0.279%/°C Linear power performance guarantee 30 years Tcmperature Coefficient Pmax -0.377%/°C 1 >98%end lstyr _._.. >_ NOCT(±2°C) 43.5°C 94.7%end l2thr- - i >_90.8%end 25thyr Operating temperatu re 1 -40/+85°C >89.3%end 30thyr CERTIFICATIONS SHIPPING SPECS 1 UL6_215-1:2017 Ed.1,L,L 61215 2.2017 Ed.1,UL 61730-1:2017 Ed.1,UL 61730-2:2017 Ed.1, Modules Per Pallet: 27 or 27(Californ ia) Product CSAC22.2#61730-1:2019Ed.2,CSAC22.2#61730-22019Ed2,IEC 61215-1:2016Ed.1,IEC ------_..-__.....___..__--.._-___._.__-_.-.__. 61215-22016Ed.1,IEC61730-1:2016Ed.2,IEC61730-22016Ed.2,IEC61701:2020(SaltMist Pallets Per Truck 31 or30(California) Corrosion),IEC 62716:2013(Ammonia Corrosion),CEC Listing,ULFireRating:Typel ----_-__._....__.. ----__..---_ _ --------------------- --- ------------------ Factory IS09001.2015 Modules Per Truck 837 or 810(California) A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads. L 73.4"[1864mm] J v E 13.1"[332mm] 47.2"[1200mm] 13.1"[332mm] ounting Hole(x4) D 5" SILFAB SOLAR INC. [12mm] 1770 Port Drive o Burlington WA 98233 USA 47.25" T+1360.569.4733 f �T [1200mm] �Q E E info@silfabsolar.com Cable Length �= on W N SILFABSOLAR.COM a 7149 Logistics Lane °' 1q Fort Mill SC 29715 USA 1.4"[35mm] v d v T+1839.400.4338 E_ A Q c4 240 Courtneypark Drive East Mississauga ON L5T2S5 Canada 3 'o T+1905.255.2501 3 0•�" C0 F+1905.696.0267 [1.5mm] a rainage Hole(x8) Silfab-SIL-420-BG-20231221 No reproduction of any kind is allowed without 2"[60mm] " 8"[200mm] permission.Data andinformationissubjectto modifications without notice.®Silfab Solar Inc., 2022.Silfab Solar*is a registered trademark of Silfab Solar Inc. r ,, Datekt C E I V E D MASON COUNTY NOV 2 5 2024 COMMUNITY DEVELOPMENT 615 W. Alder Sheet Permit Assistance Center,Building,Planning Permit#: Property Owner's Authorization Letter Name Jan Nelson Mailing Address 401 E Benson Ridge Rd City Grapeview State WA zIP 98546 Phone 253-302-9012 Email jan.nelson@outlook.com Parcel Number 22104-43-50200 Site Address 401 E Benson Ridge Rd City Grapeview State WA zip 98546 I(we): Jan Nelson (Property Owners Name) Hereby Authorize: South Sound Solar- Rosie Rumsey (Name of Person%Contractor to Sign Permit) To apply for, sign, and pick-up building permits for the following proposed work: Installation of 10 Solar Panels. Expansion of Existing Solar (Brief Description of Work to be Done) As property owner(s),I(we)hereby grant permission to the applicant referenced above to apply for,sign,and pick- up the building permit for the work as indicated above.All work performed must meet all provisions of the Building Codes and the Laws of Mason County and the State of Washington, as applicable,whether specified or not.Residential Contractors are required to have a current State of Washington Contractors License(RCW 18.27). 25/11/24 J7 Ne:­;No 25,2,24 08 2 P (Property Owner Signature) (Date) r Property Owner's Authorization Final Audit Report 2024-11-25 Created: 2024-11-25 By: Rosie Rumsey(Rosie@southsoundsolar.com) Status: Signed Transaction ID: CBJCHBCAABAAKnddZLSghszUNXfuWJn43sPBAs9M1MiT "Property Owner's Authorization" History Document created by Rosie Rumsey(Rosie@southsoundsolar.com) 2024-11-25-4:25:02 PM GMT-IP address: 173.14.248.237 Cw Document emailed to Jan Nelson oan.nelson@outlook.com)for signature 2024-11-25-4.25:06 PM GMT Email viewed by Jan Nelson Oan.nelson@outlook.com) 2024-11-25-4:26:20 PM GMT-IP address: 164.152.179.47 Document e-signed by Jan Nelson 0an.nelson@outlook.com) Signature Date:2024-11-25-4:27:07 PM GMT-Time Source:server-I address: 164.152.179.47 ! Agreement completed. 2024-11-25-4:27:07 PM GMT Adobe Acrobat Sign