Loading...
HomeMy WebLinkAboutBLD2011-00995 Final Woodstove to Propane - BLD Permit / Conditions - 1/4/2012 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 11 Shelton, WA 98584 �� MECHANICAL PERMIT BLD2011-00995 OWNER: ROBERT, WILSON-HOSS RECEIVED: 12/16/2011 CONTRACTOR: LICENSE: EXP: ISSUED: 12/16/2011 SITE ADDRESS: 211 E WOODBRIDGE LN SHELTON EXPIRES: 6/16/2012 PARCEL NUMBER: 321342100000 LEGAL DESCRIPTION: NE NW EX TR 1-2 PROJECT DESCRIPTION: DIRECTIONS TO SITE: CHANGING WOOD STOVE TO PROPANE, WITH PROPANE TANK AND OUTLETS General Information Setback Information Type of Use: SF Insp.Area: Front: Ft. Shoreline: Ft. Type of Work: MEC Fire Dist.: 5 Rear: Ft. Slope: Ft. Side 1: Ft. Valuation: Side 2: Ft. _ Mechanical Fixtures FEES Type Qty. Type By Date Amount Receipt Gas Outlets 2 Mechanical Permit Fee GMM 12/16/201 $152.20 S120110000( Propane Tank 1 Mechanical Base Fee GMM 12/16/201 $28.50 S120110000C Propane Stove 1 Total $180.70 BLD2011-00995 Please refer to the following pages for conditions of this permit. Page 1 of 3 CASE NOTES FOR BLD2011-00995 CONDITIONS FOR BLD2011-00995 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X r 2) ALL FURNACE INSTALLATIONS SHALL MEET THE MINIMUM EFFICIENCIES SET FORTH IN THE CURENT EDITION OF THE WASHINGTON STATE ENERGY CODE (WSEC). ANY PORTION OF THE MECHANICAL SYSTEM THAT IS ALTERED OR REPLACED SHALL MEET THE MINIMUM STANDARDS SET FORTH IN THE WSEC AND INTERNATIONAL MECHANICAL CODE. X r 3) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. 4) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks filled on site must be located a minimum of 10' from any possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), mechanical system air intake (direct vent appliance, ventilation air intake, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Propane tanks less than 125 gallons must also be located a minimum of 5' from any building opening (foundation vents, windows, doors etc). Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 5-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, tive bollards must be installed. X � lprotec 5) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All Propane tanks between 125 and 500 gallons must be located a minimum of 10' from any building, possible source of ignition (electrical outlets, electrical fixtures, compressors, etc), and/or any weeds, grass, brush, trash or any other similar combustible materials. Setback to the public way, or access easements shall be the greater of 25-ft or as specified in the Mason County Development Regulations. Setback to property lines shall be the greater of 10-ft or as specified in the Mason County Development Regulations. If a propane tank is exposed to probable vehicular damage, protective bollards must be installed. X 6) All propane tanks must be installed in accordance with the International Fire Code and all applicable Mason County ordinances. All propane tanks must meet the installation requirements and minimum setbacks as listed in the Mason County Fire Marshal's Standards for the Installation of Propane Tanks. X (, BLD2011-00995 Please refer to the following pages for conditions of this permit. Page 2 of 3 7) Fuel piping shall be inspected after the installation of fuel piping is complete, and before the attachment of fixtures, appliances, or shut-off valves. At the time of inspection the test pressure shall be no less than 10 psi held for no less than 15 minutes. Appliances to be attached to the fuel piping system shall not be used until the final inspection has been performed and approved by a Mason County building inspector. X /A_ - 8) Owner/applicant must obtain a seperate permit for the placement of any size propane tank serving a fixed appliance within a dwelling structure or unit prior to the placement of the tank. X �- 9) The placement of small propane tanks are not normally subject to a permit review by the Planning Department; however, propane tanks are subject to Planning Department regulations. Such regulations primarily consist of setbacks from shorelines and features considered to be critical areas (streams, wetlands, slopes, etc.) If you think suc eatures exist on or nearby your property, please contact the Planning Department so that exact setback requirements can be determined. X 10) All property lines shall be clearly identified at the time of foundation inspection. X 11) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Masop,County ordinances and building regulations. X Zf L--- 12) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X f L- 13) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: DATE: l Z a l <' . 'Zio ( ( BLD2011-00995 Please refer to the following pages for conditions of this permit. Page 3 of 3 W � o CONCRETE Gab Piping MANUFACTURED HOME o. Interior-Date By Footings/Setbacks Ribbons Cn Exterior-Date By 0 Deto By INSULATION Gate By I con Foundation Walls BG/SLAB INSULATION Set-up 0 Da to By Bate By Date By (1) FRAMING Floors FIRE DEPARTMENT Date By Date By 0 Date BY Walls ^� W PLUMBING pate By LDECKS ate By X Groundwork Vault TANKS Gate BY Date By Oate BY Attic a.W.V Date By OTHER Date By DRYWALL Type.Date BY Wafter Line Date By Type. Date By Int.Brace Wall Date By W MECHANICAL Date By FINAL INSPECTION N m Fire Seperatic>n O fD Date By Date By Date Z By m O ° Pass or Request Inspect. M Type of Insp. Fall Date Date Done By Comments _ lhNK T,:P Go GIiT HoaF d- wac.r8E T2o/C,- m a o' 0 0 y U (D 3 jv cQ (D 0 • 58-30 LIQUEFIED PETROLEUM GAS CODE Table 6.3.1 Separation Distances Between Containers,Important Buildings,and Line of Adjoining Property That Can Be Built Upon Minimum Distances Mounded or Water Capacity Underground Aboveground Between per Container Containers' Containersb Containers` gal Ins ft m ft In ft In <125d <0.5d 10 3 0` 0° 0 0 125-250 0.5-1.0 10 3 10 3 0 0 251-500 >1.0-1.9 10 3 10 3 3 1 501-2,000 >1.9-7.6 10 3 25f 7.6 3 1 2,001-30,000 >7.6-114 50 15 50 15 5 1.5 30,001-70,000 >114-265 50 15 75 23 70,001-90,000 >265-341 50 15 100 30 Y4ofSUM of 90,001-120,000 >341-454 50 15 125 38 diameters of 120,001-200,000 >454-757 50 15 200 61 adjacent 200,001-1,000,000 >757-3785 50 15 300 91 containers >1,000,000 >3785 50 15 400 122 'See 6.3.4. b See 6.3.12. 'See 6.3.11. d See 6.3.9. See 6.3.7,6.3.8,and 6.3.9. f See 6.3.3. Table 6.3.8 Separation Distance Between Container Pressure and mechanical ventilation air intakes shall be in accordance with Table 6.3.8. Relief Valve and Building Openings 6.3.10 Access at the ends or sides of individual underground Discharge fro containers having a water capacity of 125 gal(0.5 ms)or more Relief Valve shall be provided in multicontainer installations to facilitate Vent Discharge, working with cranes or hoists. and Filling 6.3.11 The horizontal distance between the portion of a build- Connection to g that overhangs out of the building wall and an ASME con- Distance Exterior Source er of 125 gal. (0.5 ms) or more water capacity shall comply Horizontally of Ignition, th the following. from Relief Openings into (1) The horizontal distance shall be measured from a point Valve Direct-Vent determined by projecting the outside edge of the over- Discharge to Appliances,and hanging structure vertically downward to grade or other Opening Mechanical level upon which the container is installed. Exchange Below Ventilation Air (2) The horizontal distance specified in 6.3.11(1) shall be at or Filled on Discharge Intakes least 50 percent of the separation distance required in Container Site at the Type Point of Use ft m ft m Table 6.3.1. (3) The horizontal distance requirement shall apply only Cylinder Exchange 3 0.9 5 1.5 when the overhang extends more than 5 ft (1.5 m) from Cylinder Filled on site 3 0.9 10 3.0 the building. o- at the point (4) The horizontal distance requirement shall not apply of use when the overhanging structure is 50 ft (15 m) or more ASME Filled on site 5 1.5 10 3.0 above the relief valve discharge outlet. at the point (5) The horizontal distance requirement shall not apply to of use ASME containers of 2001 gal through 30,000 gal (7.6 m through 114 mg) water capacity where the container dis- tance from a building is in accordance with 6.26.2. 6.4 Other Container Location Requirements. 6.3.9 The distance measured in any direction from the point 6.4.1 Where storage containers having an aggregate water of discharge of a container pressure relief valve,vent of a fixed capacity of more than 4000 gal(15.1 m 3)are located in heavily maximum liquid level gauge on a container, and the con- populated or congested areas, the siting provisions of 6.3.1 tainer filling connection to exterior sources of ignition,open- and Table 6.3.1 shall be permitted to be modified as indicated ings into direct-vent (sealed combustion system) appliances, by the fire safety analysis described in 6.25.3. 2011 Edition PERMIT NO. MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar- P.O. Box 186,Shelton,WA 98584 Shelton (360)427-9670-Belfair(360)275-4467-Elma(360)482-5269 On the web www.co.mason.wa.us APPLICANAIN OR TIO CONTRACTOR INFORMATION Owner I UYl .-Company Name Mailin - dr s &fl ailing Address City State Zip Code City State Zip Code Phone Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic.# DOB SEPTIC INFORMATION - Connect to New Septic Existing Septic. Connect to Sewer System Name of Sewer System PARCEL INFORMATION- 12 Digit Parcel No I - Fire District Legal Description Site Address(Please include street name, street number and city) Directions to site Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% TYPE OF JOB - New Add Alt Repair Other Use of Building Location of Fixtures/Units- 1st Floor 2nd Floor Basement Garage Closet PLUMBING FIXTURES(Show Number of each) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:Electric_LPG Natural Gas_Heat Pump_ Toilets ape of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heatpumps Showers Spot Vent Fan Water Heater Propane Tank N � Clothes Washer Gas 0 Wood as Kithen Sinks a ellet Stove � Dishwasher Kitche aust Hood Hosebibs Dryer Vent Other Other Base Fee Base Fee 73.5D TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other parry in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. X I Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYQN T IS POINT Accepted b tanning Pd Ck# Date o2 1 i Bld Pd Receipt No. DEPARTM NTAL REVIEW APPROVED DENIED NOTES Building Department Occ Group TVpe Constr. Planning Department Environmental Health Department FEES Plumbing & Base Fee Site Inspection Mechanical &Base fee UFC Plan Review Fee Wood/Gas/Pellet Stove Fee Other Violation Fee TOTAL FEES