HomeMy WebLinkAboutGEO2010-00059 - GEO Geological Review - 10/19/2010 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Planning Division P O Box 279, Shelton, WA 98584 r9lo (360)427-9670 Geotechnical Assessment Review Acceptance Letter October 19, 2010 JIM PEAVEY 13420 99TH ST CT KPN GIG HARBOR WA 98329 Case No.: GE02010-00059 Parcel No.: 121084190061 Proiect Description: GEO TECH ASSESSMENT FOR THE NEW CONSTUCTION OF NEW SFR (SEE BLD2010-00833) The Geotechnical Assessment for JIM PEAVEY has been received and reviewed by the Planning Department. The assessment was prepared by Curtis Cushman dated 8/20/2009. Based on the certification provided by the licensed engineer/geologist, the referenced Geological Assessment was prepared in general accordance with the requirements in the Mason County Resource Ordinance, Landslide Hazard Areas 17.01.100.E.4. Mason County considers the review valid until such time as scope of project, site conditions, and/or regulations change. Should the scope of work, site conditions, and/or regulations change after the original review, then an addendum from the original author of the assessment may be required to address these changes. The assessment would only be re-reviewed if a permit for development were submitted after these changes occur. Mason County does not certify the quality of the work done in this Geological Assessment. Please contact me at (360) 427-9670, ext. 365 if you have questions. Sin y, �� O�V-6� Allan Borden Land Use Planner Mason County Planning Department Comments: 10/19/2010 Page 1 of 1 GE02010-00059 Mason County Review Checklist For a Geoloqical Assessment Instructions: This checklist is intended to assist Staff in the review of a Geological Assessment. The Assessment is reviewed for completeness with respect to the Resource Ordinance. If an item is found to be not applicable, the report should explain the basis for the conclusion. The Assessment is also reviewed for clarity and consistency. If the drawings, discussion, or recommendations are not understandable, they should be clarified. If they do not appear internally consistent or consistent with the application or observations on site, this needs to be corrected or explained. If resolution is not achieved with the author, staff should refer the case to the Planning Manager or Director. J 0 Applicant's Name: j VVI �2e�jW 1 `, �/ I Permit# 2-0 "! ' 009`parcel# 1 �V q -r 4 ( � �w6 l Date(s)of the Document(s)reviewed: 42,v 0!7 (1) A discussion of geologic conditions in the general vicinity of the proposed development, with geologic unit designation based on refergnped maps. OK? V Comment: (2) (a)A dis sion of the ground water conditions at the site, OK? Comment: (b) A disc}�ssion of the estimated depth to water OK? ✓ Comment: (c) A disc ion of the quantity of surface seepage OK?Comment: (d) A discy�sion of the upslope geomorphology OK? ✓ Comment: (e) A discu ion of location of upland waterbodies and wetlands. OK? Comment: (3) The app,o cimate depth to har nse competent soil,e.g. glacial till or outwash sand. OK?_L Comment: ffl (4) A discussion of any geomorphic lexpression of past slope instability(presence of hummocky ground or ground cracks, terraced topography indicative of landslide block moverr e�r t, bowed or arched tree intating downslope movement, etc.). OK? L_Comment: (5) A discussion of the history of la ds de activity in the vicinity, as available in the refereyd maps and records. OK?-Comment: f (6) An opinion on whether the prop4sed development is within the landslide hazard area or its associated buffer or setback and the potential for landslide activity at the site in light of the proposed development. OK? VV��Comment: /J1 (7) A recomr`nendation by the preparer whether a Geotechnical Report should be required to further valuate site conditions an roposed development of the subject property. OK? Comment: (8) If the pre ence of a hazard is determined within 300 feet of the proposed development, then the following are delineated on a geologic map/site map: (a) the,a1ea of the proposed devel pment, OK? V�_Comment: 14 Lk, U Page 1 of 2 Form Effective June 2008 (b) the boundaries of the I fide hazard area (top, both sides, and toe), OK? Comment: � (c) the associated buffers (top,-f'othsides, and toe) OK? Comment: /V (d) building or other setbacks (top, both sides, and toe). OK? Comment: AJ IA (9) A site map drawn to scale showing the property boundaries, scale, north arrow, and the location V nature of existing a d proposed deve_ lop ment on the site.the site. ( Comment: Y Are the Document(s)signed and stamp d? . Type and #of License: C • � !/ 42b If not approved, what is the next action/recommendation for further action? Reviewed by on Time spent in review: SECOND REVIEW/UPDATE: Reviewed by , on Time spent in second review: THIRD REVIEW/UPDATE: Reviewed by on Time spent in third review: Disclaimer: Mason County does not certify the quality of the work done in this Geological Assessment Page 2 of 2 Form Effective June 2008 Form Effective June 2008 Mason County Department of Community Development Submittal Checklist For a Geological Assessment Instructions: This check list must be submitted with a Geological Assessment and completed, signed, and stamped by the licensed professional(s) who prepared the Geological Assessment for review by Mason County pursuant to the Mason County Resource Ordinance. If an item found to be not applicable, the report should explain the basis for the conclusion. Applicant/Owner: Jim Peavey Parcel#: 121084190061 Site Address: (1) A discussion of geologic conditions in the general vicinity of the proposed development,with geologic unit designation based on referenced maps. Located on page(s) 7 (2) (a) A discussion of the ground water conditions at the site, Located on page(s) 8 (b) A discussion of the estimated depth to water Located on page(s) 8 (c) A discussion of the quantity of surface seepage Located on page(s) 8 (d) A discussion of the upslope geomorphology Located on page(s) 5-6 (e) A discussion of location of upland water bodies and wetlands. Located on page(s) 8 Form Effective June 2008 (3) The approximate depth to hard or dense competent soil, e.g.glacial till or outwash sand. Located on page(s) 8 (4) A discussion of any geomorphic expression of past slope instability(presence of hummocky ground or ground cracks,terraced topography indicative of landslide block movement, bowed or arched trees indicating down slope movement, etc.) Located on page(s) 8 (5) A discussion of the history of landslide activity in the vicinity, as available in referenced maps and records. Located on page(s) 9 (6) An opinion on whether the proposed development is within the landslide hazard area or its associated buffer or setback and the potential for landslide activity at the site in light of the proposed development. Located on page(s) NA (7) A recommendation by the preparer whether a Geotechnical Report should be required to further evaluate site conditions and the proposed development of the subject property. Located on page(s) NA (8) If the presence of a hazard is determined within 300 feet of the proposed development,then the following are delineated on a geologic map/site map: (a) the area of the proposed development, Located on Map(s) NA (b) the boundaries of the landslide hazard area (top, both sides, and toe), Located on Map(s) NA (c) the associated buffers (top, both sides, and toe), Located on Map(s) NA Form Effective June 2008 (9) A site map drawn to scale showing the property boundaries,scale, north arrow, and the location and nature of existing and proposed development on this site. Located on Maps(s) Figure 2 I, Curtis D Cushman hereby certify under penalty of perjury that I am a geologist or engineering geologist licensed in the State of Washington with special knowledge of the local conditions. I also certify that the Geological Assessment, dated August 20, 2009 and entitled 395 E Stretch Island Road S, Grapeview, WA meets all the requirements of the Mason County Resource Ordinance, Landslide Hazard Section, is complete and true, that the assessment demonstrates conclusively that the risks posed by the landslide hazard can be mitigated through the included geotechnical design recommendations, and that all hazards are mitigated in such a manner as to prevent harm to property and public health and safety. (Signature and Stamp) °{ Washl. A .a eer' 3aaiocisi ` 2429 Disclaimer: Mason County does not certify the quality of the work done in this Geological Assessment. r 4Eo 20 i o - 00059 RECEIVED V 14 20W MASON COUNTY GEOLOGICAL ASSESSMENT PLANNING 395 EAST STRETCH ISLAND ROAD SOUTH GRAPEVIEW, WASHINGTON PREPARED FOR JIM PEAVEY BY GEOTECHNICAL TESTING LABORATORY, INC. OLYMPIA, WASHINGTON �I AUGUST 20, 2009 r GEOTECHNICAL TESTING LABORATORY CONTACT INFORMATION PREPARER INFORMATION GTL PROJECT NUMBER: 09-0159 CONTACT: CURTIS D.CUSHMAN ADDRESS: 10011 BLOMBERG STREET SOUTHWEST OLYMPIA,WASHINGTON 98512 TELEPHONE: (360)754-4612 FACSIMILE: (360)754-4848 EMAIL ADDRESS: GEOTESTLAB@COMCAST.NET CLIENT INFORMATION CLIENT: ZECH BUILDERS CLIENT CONTACT: MIKE ZECH TELEPHONE: (360)340-2490 BILLING ADDRESS: ZECH BUILDERS P.O.Box 516 GRAPEVIEW,WASHINGTON 98546 SITE ADDRESS: 395 EAST STRETCH ISLAND ROAD SOUTH GRAPEVIEW,WASHINGTON 98546 PARCEL: 121084190061 GPS LOCATION: N47° 19'12.55".W 122°49126.95" 10011 Blomberg Street SW,Olympia,WA 98512 2 Phone#: (360)754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY SCOPE OF UNDERSTANDING ZECH BUILDERS P.O.Box 516 GRAPEVIEW,WASHINGTON 98546 RE: GEOTECHNICAL REPORT 395 EAST STRETCH ISLAND ROAD SOUTH GRAPEVIEW,WASHINGTON 98546 PARCEL#121084190061 N47019'12. 55"W1220 49'26.95" AUGUST 20,2009 Dear Zech Builders: As per your request,we have conducted a geological assessment and analysis for the above-mentioned parcel. The results of this investigation are to be found in the following assessment. We have provided three copies for your review and distribution. We are also a full service laboratory that can meet all your building, testing(soils compaction, asphalt, concrete, resteel), and other inspection needs. We appreciate this opportunity to be of service to you and we look forward to working with you in the future. If you have any questions concerning the above items, the procedures used, or if we can be of any further assistance please call us at the phone number listed below. Respectfully Submitted, GEOTECHNICAL TESTING LABORATORY Vijay Chaudhary,E.I.T Staff Engineer 04 W ashen ra I 8 c�Y-tea y F.irq(nodng Geologist _ 2439 S ed GeO\° Curtis D Cushman Senior Engineering Geologist =_J'__'T1S_DEAN CUSHMAN 10011 Blomberg Street SW,Olympia,WA 98512 3 Phone#: (360)754-4612 Fax#: (360)7544848 GEOTECHNICAL TESTING LABORATORY TABLE OF CONTENTS CONTACT INFORMATION............................................................................................... 2 SCOPE OF UNDERSTANDING .................................................................................................. 3 TABLE OF CONTENTS...................................................................................................... 4 PURPOSE................................................................................................................................ 5 SITECONDITIONS................................................................................................................... 6 GEOLOGICCONDITIONS ......................................................................................................... 7 SITESOILS ............................................................................................................................. 7 SURFACE WATER CONDITIONS ............................................................................................... 8 GROUNDWATERCONDITIONS................................................................................................. 8 DEPTH TO COMPETENT SOIL.................................................................................................. 8 PAST SLOPE INSTABILITY....................................................................................................... 8 HISTORY OF LANDSLIDE ACTIVITY........................................................................................ 9 POTENTIAL FOR LANDSLIDE ACTIVITY .................................................................................. 9 RECOMMENDATIONS.............................................................................................................. 9 VICINITYMAP...................................................................................................................... 10 COASTALZONE ATLAS MAP................................................................................................ 11 WELLLOGS ......................................................................................................................... 12 10011 Blomberg Street SW, Olympia,WA 98512 4 Phone#: (360)754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY PURPOSE This report summarizes the results of our geotechnical consulting services for the proposed single-family residence. The single-family residence will be constructed on Stretch Island on a developed site facing east overlooking Case Inlet. The assessment has been commissioned by Mike Zech of Zech Builders for Mr. Jim Peavey. The parcel(1.05 acres) is irregular in shape,elongate east to west, and located along the east shore of the island (see photo in "Site Conditions" below). The site is approximately 4.0 miles south of downtown Allyn, Washington. The site will be accessed from East Stretch Island Road South by private road. 10 �r.r y y Our understanding of the project is based on our discussions with Mike Zech of Zech Builders. We understand that the parcel is to be developed with a single-family residence. In general, grading is not expected as the house will be built on its original footprint. The existing septic drain will be reused. The approximate layout of the site is shown on the Site Plan,Figure 2. The steepest slope measured onsite was approximately 35 percent maximum except at some low cuts. (The parking area is very steep to the west, but this is on fill and does not represent the overall slope.) Mason County requires that a geological assessment be prepared in accordance with the Critical Areas Ordinance under these circumstances. The Mason County Resource Ordinance Geologically Hazardous Areas(12-27-2006)contains the following: 17.01.100 Landslide Hazard Areas E. Special Reports 1. Applicability Category d. Development proposed within 300 feet of areas with slopes between 15 percent (8.5 degrees) and 40 percent (21.8 degrees) will require a Geological Assessment, and may further require a Geotechnical Report upon the findings of the assessment. 10011 Blomberg Street SW,Olympia,WA 98512 5 Phone#: (360)754-4612 Fax#: (360)7544848 GEOTECHNICAL TESTING LABORATORY SITE CONDITIONS The proposed building site is located in an area of limited residential development along the eastern side of Stretch-Isaland overlooking Case Inlet(see aerial photos below). Ly lwwr AV 4 f 3`A At the project site, exploration was conducted on August 7, 2009 by Curtis D Cushman and Vijay Chaudhary. The purpose of a site inspection was to physically observe the property and adjacent properties to identify any recognized geologic conditions. Photographs and visual observations were documented. Site-specific features were mapped and vegetation was noted. This site is developed to the current configuration of roadway leading to the side of the hillside cabin and deck. There is little landscaping. The central portion of the site will be developed with a single-family residence. The site has a predominantly eastern exposure and is vegetated with mature and immature evergreens and local foliage. Site elevations range from approximately Sea Level to 80 feet. The site is approximately 20 feet above the water. The general topography of the building site area indicates that drainage flows directly east toward Case Inlet. The site plan is included as Figure 2. No evidence of active surface erosion outside of minor slough on roadcuts was observed. No surface water flow was observed onsite. No ponding of water was observed on the site. Slumping and sloughing was not observed on site. No evidence of deep-seated slope instability was observed onsite. No seeps or springs were observed onsite. Onsite trees were observed to be straight and vertical with the exception of a few near the parking area that appear to be recently tilted. These do not affect the building site and pose no hazard to the construction. . 10011 BlombergStreet SW Olympia,WA 98512 � YmP 6 Phone#: (360)754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY GEOLOGIC CONDITIONS The slope material is composed glacial till(gravelly sand with silt). See description below. The Geologic Map of Washington —Northwest Quadrant(2002) has mapped the geology as glacial till deposits (Qgt)of continental glacial origin. The report reads: Till— Unsorted unstrati ied f highly ghly compacted mixture of clay, silt, sand, gravel, and boulders deposited by glacial ice; may contain interbedded stratified sand, silt, and gravel. Includes part of the Vashon Drift undivided. i Qgt is also described as Vashon Till- Unsorted, unstratified, highly compacted mixture of clay, silt, sand, gravel, and boulders deposited by glacial ice of the Puget lobe, gray, may contain interbedded stratified sand, silt, and gravel; sand-size fraction is very angular and contains abundant polycrystalline quartz, which distinguishes this unit from alpine till, cobbles and boulders are commonly striated and(or)faceted, although unweathered almost everywhere, may contain cobbles or small boulders of deeply weathered granitic rock This is in keeping with the mapping of Molenaar and Nobles in the GEOLGY AND RELATED GROUND-WATER OCCURRENCE, SOUTHEAST MASON COUNTY, WASHINGTON; Water- Supply Bulletin No.29,Department of Water Resources, State of Washington, 1970,as follows: Qvt(Till): cobbles and coarse gravel in matrix of fine sand, silt, and clay. Generally a compact, unsorted mixture. Extensively underlies dr jft plains in thicknesses of a few feet to more than 50 feet. The Qvt designation has been superseded by the Qgt. SITE SOILS The Web Soil Survey of the USDA has the soil on site incorrectly labeled as Rb, "rough broken soil." As this is in common usage for landslides,and represents areas with slopes of 45%to 90%, it is not correct for this area. The following soil is found nearby, and is most likely correct: The Soil Survey of Mason County, Washington, USDA Soil Conservation Service(1960)has mapped the site soils as Alderwood gravelly sandy loam, 5 to 15 percent slopes(Ab). The survey reads, The Alderwood soils typically formed from mixed gravelly glacial till dominated by acid igneous rock It occupies undulating to rolling moraines. In undisturbed areas, a 1- to 2-inch mat of very dark brown, acid organic matter is on the surface. This grades to a thin, dark grayish- brown, highly organic mineral soil. The surface soil consists of a friable, brown, medium acid gravelly sandy loam 8 to 13 inches deep. It has a weak granular structure and contains numerous rounded shot. Below the surface soil, to depths ranging from 18 to 24 inches, is a pale-brown gravelly sandy loam that is very friable, is single grained, and contains small to moderate amounts of shot. 10011 Blomberg Street SW,Olympia,WA 98512 7 Phone#: (360)754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY Between this layer and the cemented till is a 3- to 10-inch layer of very pale brown gravelly sandy loam. It contains no shot and is firmer but has the same texture as the layer above. However, it is faintly to distinctly spotted and horizontally streaked with brown and yellow. The cemented till consists of light-gray, gravelly sandy loam, and it normally occurs at depths ranging from 24 to 32 inches. It is impermeable to roots and very slowly permeable to water. The first few inches is usually laminated and streaked with reddish brown and yellow. Below this, to a depth of many feet, the till is uniformly cemented, uniform light gray, and medium to strongly acid. A thin mat of roots often lies over the till. The cemented substratum tends to restrict the rapid downward movement of moisture. They are described as having good natural drainage. Typically, there is no occurrence of a high water table. Internal drainage is described as medium. An erosion hazard may exist if the vegetation is removed, otherwise, the soil has a low erosion hazard in its present condition. Cementation is usually present. The soils are not considered hydric. Due to the previous development of the cabin, etc. these soils have likely been removed and will not be of importance for the new construction. SURFACE WATER CONDITIONS No surface water flow was observed onsite at the time of site visit. No ponding of water was observed throughout the site. No seeps or springs were observed onsite. Wetland vegetation was not observed at or near the proposed building location. No upland wetlands were observed on or near the site. No water was observed at the time of site visit. GROUNDWATER CONDITIONS Groundwater seepage was not observed at the proposed building location or throughout the site. Research of the local wells indicates that depth to static groundwater is greater than 50-foot on the site. DEPTH TO COMPETENT SOIL The site is underlain,in general;by stiff to dense Alderwood, gravelly sandy loam(silty sand with gravel)and was observed at the surface throughout the site. This is underlain by competent glacial till. The proposed building location has no soil exposure as the footprint is covered by the existing building. PAST SLOPE INSTABILITY Surrounding the subject site, trees were observed to be straight and vertical. No indication of past instability was discerned at the proposed building location. The tilted trees at the parking pad may be caused by pushed-over material. 10011 Blomberg Street SW,Olympia,WA 98512 g Phone#: (360)754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY HISTORY OF LANDSLIDE ACTIVITY There is no landslide mapped on and around the site based on the review of available maps and documents. The site has been mapped Intermediate by the Coastal Zone Atlas Maps MA_13iith(CZAW). The map is provided at the end of this report. The Relative Slope Stability of the Southern Hood Canal Area, Washington by Smith & Carson (1977) has mapped the site as Class 1. The survey reads: Areas believed to be stable. Slopes generally less than 15 percent, but may be greater locally in areas too small to be shown in the map scale. Largely comprises rolling uplands underlain by very stable material such as young glacial till, mantles in places by a thin layer of sandy gravel or other permeable material, also includes flood plains, deltas, alluvial fans, and some beach deposits. Class 1 areas immediately adjacent to steep slopes of class 3 areas may be threatened by potential landsliding. Normal,proper engineering practices generally are adequate to insure stabilities in these areas. POTENTIAL FOR LANDSLIDE ACTIVITY The Liquefaction Susceptibility Map of Mason County, Washington by Palmer, Magsino, Poelstra, Bilderback, Folger, and Niggemann(September 2004)maps the site area as having a very low liquefaction potential. The Site Class Map of Mason County, Washington by Palmer, Magsino, Bilderback, Poelstra, Folger, and Niggemann(September 2004)maps the site area as site class C. Site class C is a stiff soil. RECOMMENDATIONS This assessment has found no conditions that would preclude construction on this site. There is no evidence of soil erosion or deposition onsite to suggest that the site should be included in the Erosion Hazard Area designation. Proposed activities and site conditions for the development do not warrant a more comprehensive Geotechnical Report. We recommend no further action is needed unless areas of concern are unearthed during construction or damage ensues from removing vegetation. To minimize erosion and sedimentation,we recommend that vegetation remain or be cultivated in areas outside the building location. If there are any changes in the loads, grades, locations, configurations or types of facilities to be constructed, the conclusions and recommendations presented in this report may not be fully applicable. If such changes are made, we should be given the opportunity to review our recommendations and provide written modifications or verifications,as appropriate. Changes to the Mason County Code require our firm to revisit the subject site prior to development, if six months has elapsed,to ensure the conditions are in agreement with our original report. 10011 Blomberg Street SW,Olympia,WA 98512 9 Phone#: (360)7544612 Fax#: (360)754-4848 • GEOTECHNICAL TESTING LABORATORY VICINITY MAP 6c` 4 / STRETCH POINT STATE PARK � � � � w• I T K r'_ jrj � � �__ �dj 1, jt� • J Y 1��� % / h APPROX. LOCATION OF SUBJECT SITE ko 0��• _ lKlyr/I I f O 20 2 Da•,o.ma. - oPOOuadn®.Oata co PYrl9 fft of content owner- ®� '� ® f���p e 1 10011 Blomberg Street SW,Olympia,WA 98512 10 Phone#: (360) 754-4612 Fax#: (360)754-4848 II r GEOTECHNICAL TESTING LABORATORY COASTAL ZONE ATLAS MAP L Scale 1:24,000 0 5 1 Miles 0 500 1000 1i00 Metres • f LEGE NDwsuu (f ti b4 a � i t U LL . r 43 r , a r 10011 Blomberg Street SW, Olympia,WA 98512 11 Phone#: (360)754-4612 Fax#:(360)754-4848 L SITE PLAN IS BASED ON SITE RECONNAISSANCE CONDUCTED BY CURTIS D CUSHMAN& FILTER FABRK MATERIAL W'WIDE ROLLS VUAY CHAUDHARY ON AUGUST 7,2009 AND MASON COUNTY GIS WEBSITE. USE STAPLES OR WIRE RING TO ATTACH FABRIC TO WIRE 277X14GAUGE WIRE �'•..._:`9t :;. k. 'A-..._..........::.%F:." FABRIC OR EQUIVALENT / SURFACE .:".% 4r tl S"MAX / 2Xr 1 / OM OF FILTER BETTER OR OREQUALB ALTERNATE:� MATERIA BUY L IN 87(12'TRENCH r STEEL FENCE POSTS r -- r FILTER FABRIC 8" / C.GAUGE HARE FABRIC OR EQUIVALENT I / GROUND SURFACE 5-0" PROVIDE 3/4'-1 1/7 WASHEDVEL BACK I / GRAVEL IN TRENCH 7 AND ON BOTH SIDES OF FILTER FENCE FABRIC ON THE SURFACE 8'MI I I I / 2'X4'WOOD POSTS r / ALT:STEEL FENCE POSTS Geotechnical Services I � FILTER FABRIC FENCE NOTES: ^ ,^ A/1`CI r 1.FILTER FABRIC SHALL BE PURCHASED INA CONTINUOUS ROLL CUTTO IYIC Services THE LENGTH OF THE BARRIER TO AVOID USE OF JOINTS.WHEN JOINTS MA Testing Services / rQgt ) ARE NECESSARY,FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST WITH A MINIMUM 54NCH O'JERLAP AND SECURELY FASTENED AT BOTH ENDS TO THE POST. r - I 2.POSTS SHALL BE SPACED A MAXIMUM OF 8 FEET APART AND DRIVEN / r SECURELY INTO THE GROUND(MINIMUM OF 30 INCHES). 3.A TRENCH SHALL BEEXCAVATED APPROXIMATELY 8 INCHES WIDE AND 12 10011 Blomberg St.SW INCHES DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. Olympia,WA 98512 / \ / 4.WHEN STANDARD STRENGTI FILTER FABRIC IS USED,A WIRE MESH UR Phone:(360)754-4612 SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE r \ ( OF THE POSTS USING HEAVY-DUTY HARE STAPLES AT LEAST 1INCH Fax:(360)754 4848 _ _ LONG,TIE WARES OR HOG RINGS.THE WARE SHALL EXTEND INTO THE \ _ rr t TRENCH A MINIMUM OF 41NCHES AND SHALL NOT EXTEND MORE THAN 38 INCHES ABOVE THE ORIGINAL GROUND SURFACE.S. THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED Date: 08/18/2009 TO THE FENCE AND 2)MICHES OF FABRIC SHALL BE EXTENDED / ' I INTO THE TRENCH.THE FABRIC SHALL NOT EXTEND MORE THAN 36 Designed by: VC INCHES ABOVE THE ORIGINAL GROUND SURFACE.FILTER FABRIC SHALL t \ r r NOT BE STAPLED TO THE EXISTING TREES. Drawn by: VC B.MEN EXTRA-STRENGTH FILTER FABRIC AND CLOSER POST SPACING IS Checked b CDC USED,THE WIRE MESH SUPPORT FENCE MAP BE EUMINATED,IN SUCH y r / ACASE,THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE DWg#:08-18-09-015 \ /:� ` r / POSTS WITH ALL OTHER PROVISIONS OR ABOVE NOTES APPLYING. r '///yyy \\ O / r / 7.FILTER FABRIC FENCES SHALL NOT BE REMOVED BEFORE THE UPSLOPE \ \`_i/g w- / AREA HAS BEEN PERMANENTLY STABILIZED. B.FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH \ / / RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL.ANY Qt REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. GENERAL EROSION CONTROL NOTES: 1. EROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO THE BEGINNINGOFCONSTRUCTION.THE PROJECT ENGINEER AND THE COUNTY SHALL INSPECT AND APPROVE THE INSTALLATION OF EROSION CONTROL MEASURES PRIOR TO BEGINNING CONSTRUCTION. 2.EROSION CONTROL MEASURES ARE NOT LIMITED TO THE ITEMS ON THIS PLAN.THE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION AND MAINTAINANCE OF ALL EROSION CONTROL MEASURES. PROJECT NAME. / NO SILTATION OF EXISTING OR PROPOSED CRAINAGE FACILITIES /// / SHALL BE ALLOWED.CARE SHALL BE TAKEN TO PREVENT MIGRATION JIM PEAVY RESIDENCE OF SILTS TO OFF SITE PROPERTIES. \� /// // \ O (/, / 3.THE CONTRACTOR SHALL MAKE DAILY SURVEILLANCE OF ALL EROSION 395 E STRETCH ISLAND RD VVV CO w / CONTROL MEASURES AND MAKE ANY NECESSARY REPAIRS OR ADDITIONS �t / " / TO THE EROSION CONTROL MEASURES.THE CONTRACTOR SHALL PROVIDE SOUTH /' ADDITIONAL EROSION CONTROL MEASURES AS DETERMINED NECESSARY V l ) BY THE COUNTY INSPECTOR ANLVOR THE PROJECT ENGINEER.FAILURE G RA P E V I E W,WAS H I N GTO N\ / / TO COMPLY IMTH ALL LOCAL AND STATE EROSION CONTROL \ / / REQUIREMENTS MAY RESULT IN CIVIL PENALTIES BEING LEVIED PARCEL 121084190061 AGAINST THE CONTRACTOR AND/OR PROJECT OWNER. / 4.DURING THE WET SEASON(NOVEMBER TO MARCH)ALL DISTURBED SOILS O WI SHALL BE STABILIZED WITHIN 48 HOURS AFTER STOP OF WORK EROSION / CONTROL MEASURES SHALL INCLUDE,BUT NOT BE LIMITED TO, RGq VISIOI T1 IS. COVERING THE EFFECTEDAREA INCLUDING SPOIL PILES TH PLASTIC SHEETING.STRAW MATING,JUTE MATTING,STRAW MULCH, / OR WOOD CHIPS.SEEDING OF THE DISTURBED AREAS SHALL TAKE / PLACE AS WEATHER PERMITS. ALL SEEDED OR SODDED AREAS SHALL BE CHECKED REGULARLY TO MAKE SURE VEGETATIVE COVERAGE IS COMLETE.AREAS SHALL BE / REPAIRED,RESEEDED,AND FERTILIZED AS REQUIRED. NORTH 8.TRACKING OF SOIL OFFSITE WALL NOT BE ALLOWED,IF ANY SOIL IS P TRACKED ONTO A COUNTY STREET,IT SMALL BE REMOVED BY THE END / ` / / OF BE THAT WORKING DAY.ANY FURTHER TRACKING OF MUD WALL THEN SCALE I"=6O //// / BEFOEDRMNGONACOUNTYSTREE7INGOF THE VEEVENTED By SPING OR MCLEBTRES 7.NO MORE THAN/ 500 LF OF TRENCH ON A DOWNSLOPE OF MORE THAN 5/ PERCENT SHALL BE OPENED AT ONE TIME. / B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES- 0 20 40 60 ` ,O / / 9.TRENCH DEWATERING DEVICES SHALL BE DSCHARGEO IN A MANNER THAT WALL I / NOT ADVERSELY AFFECT FLOWING STREAMS.DRAINAGE SYSTEMS OR OFFSITE PROPERTIES. = O�' / 70.ALL STORM SEWER INLETSRECEIVING RUNOFF FROM THE PROJECT DURING SCALE:1 inch 60 feet BE / CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER / WILL BE FlLTERE BEFORE ENTERING THE CONVEYANCE SYSTEM. 11.ALL OFFSITE CATCH BASINS IMMEDIATELY AOUCENT TO THE SITE Q / S BE PROTECTED FROM SILTATION. (�Q / 12.ALLLL DISTURBED AREAS SHALL BE SEEDED OR SODDED UPON COMPLETION' OF WORK THE CON RACTOR SHALL BE RESPONSIBLE TO ENSURE THAT FIGURE 2 COMPLETE COVERAGE OF THE DISTURBED AREAS IS PROVIDED 8 THAT / GROWTH OF THE VEGETATION IS ESTABLISHED. SITE PLAN / 13.CATCH BASINS SHALL TRAP SEDIMENT OR FILTER FABRIC MUST BE / PLACED UNDER GRATE UNTIL VEGETATION IS ESTABLISHED. GEOTECHNICAL TESTING LABORATORY WELL LOGS WATER WELL REPORT CURRENT Original&I"copy-Ecology,2"copy-owner,3"copy-driller Notice of Intent No. W 214768 e'c"o'i'li'c'r Unique Ecology Well ID Tag No. APN 955 Construction/Decommission('k"in circle) ID Construction Water Right Permit No. O Decommission ORIGINAL INSTALLATION Notice Property Owner Name Iawrencx- Mast oflruent Number as9 b Well Street Address 581 E Stretch TS_ rl_.q- PROPOSED USE: Q Domestic ❑ Industrial ❑ Municipal City C�-ar�eview County mason ❑De Water 0 Irrigation ❑Test Well ❑Other TYPE OF WORK: Owner's number of well(if more than one) Location SW 1/4-1/4 SE 1/4 Sec B_ Twn_21 RAW E or m aide ( wwM one 14 New well ❑Reconditioned Method:O Dug ❑Bored ❑Driven g ❑ Lat/LOng(S Deepened M Cable ❑Rotary O Jetted ,t,r Lat De Lat Min/Sec DIMENSIONS: Diameterorwell_ inches,driued -410n ft. Still REQUIRED) Depth of completed well 310 ft Long Deg Long Min/Sec CONSTRUCTION DETAILS Tax Parcel No. 1 21 08-43-001 90 Casing Welded _6_" Diem.from 4 1 ft to Installed: 9 Liner installed Diam from ft to ft CONSTRUCTION OR DECOMMISSION PROCEDURE ❑Threaded Diam.from ft.to ft. Perforations: ❑Yes R No Formation:Describe by color,character,sin of material and structure,and the kind and Type of perforator used ttatltre of[ht erial in each stratum penetrated,with at least one entry for each change of mat information. USE ADDITIONAL SHEETS IF NECESSARY. .SIZE of peels in.by in.and no.of perfs=from_fL to_ft. MATERIAL FROM I TO Screens: R Yes ❑No Ek K-Pac Location 298 Manufacturer's Name .Tnhnp;nn To soil Type stainless Model No. Diam. 5 Slot size 16 from 300 ft to al a ft. - Dim Slot siu from ft.to ft. Grevel(Filter packed:tJ Yes E3ENo ❑Sin of gravel/sand Materials placed from ft.to - ft. Sand Surface Seal: !{Yes ❑No To what depth? 1-8 ft. Material used in seal Bet-oni.tP Gray silty clay with water 68 CIO Did any strata contain unusable water? D Yes j[I No Type of water? Depth of strata — Blue clay W Method of scaling strata off PUMP: Manufacturer's Name Type: &J—h H.P. - S WATER LEVELS:Land-surface elevation above mean sea level ft. Static level 53 ft.below top of well Date Artesian pressure lbs.per square inch Date Artesian water is controlled by valve etc. WELL TESTS: Drawduwn is amount wear level is lowered below static level Was a pump test made?❑ Yes P No If yes,by whom? Yield: cal./rrtin.with ft.drawdown after hrs. Yield: ¢al./min.with ft.drawdown after hrs. Yield: ¢alJmin.with ft.drawdown after furs. R—ery data(nme taken to zero when pump tvmed off)(water level rnearitredfrom welt top to water level) Time Water level Time Water Level Time Water Level Date of test Bailer test gal./min.with 1 9 ft.dmwdown after�_lus. APR L: I Ainest gaUmin.with stem set at ft.for his. �Yl QJlmr-m.1. JIUIG, Artesian flow P.M.¢. Date Temperature of water Was a chemical analysis trade? ❑Yes MNo UCI)G!tiT!Gltt(it L.L;U V l' start Date 1/12106 Completed Date 112910E WELL CONSTRUCTION CERTIFICATION: I constructed and/or accept responsibility for construction of this well,and its compliance with all Washington well construction standards. Materials used and the information reported above are true to my best knowledge and belief. ❑Driller❑Engineer❑Trainee Name (Print) Dwane Drilling Company r„gvi Ft rlr-i 1 g-1 i n Drillcr/Engineerlrrainec Signature ll d]. ) ^mot Address -440 jam' ,Ii1VlS 1•',= R�;. ' Driller or trainee License No, NWT 1 706 V r City,State,Zip 73r,l fyira WA 98528 If TRAINEE, Contractor s Drillers Ll cased No. Registration No.DAVISDI110t7A Date Jan_ nr, Driller's Signature Ecology is an Equal Opportunity Employer ECY'050-1-20(Rev 3105) The Department of Ecology does NOT warranty the Data and/or Information on this Well Report. 10011 Blomberg Street SW, Olympia, WA 98512 12 Phone#: (360) 754-4612 Fax#: (360)754-4848 GEOTECHNICAL TESTING LABORATORY WATER WELL REPORT mRRNotiENTtentNo W 159409 i'c ii'i tc'r'Original&1st copy-Ecology,2nd copy-owner,3rd copy-driller Unique Ecology Well ID Tag No Ar_c,lig + ConStrvcL'on[Decommimon(z"in circle) i fA Construction Water Right Pemut No CL Q Decomnussion OGINJiLCONSIRUC770N Notice Iruent Number Property Owner Name Patricia Funk PROPOSED USE: I]Domestic ❑Industrial ❑Municipal Well Street Address 467 E Stretch Island Rd. S ❑DeWater ❑(rogation ❑Test Well ❑Othu TYPEOFWORK. Owners number of well(if more than one) City GrdpeVleW County Maenn NKINew Well ❑Reconditioned Method ❑Dug ❑Bored ❑Driven LocadOnUL-1/4-114 QP,_i/4 Sam. Twn-_Ll- R_j*_EWM aide one .� ❑Deepened EFtable ❑Rotary ❑Jetted Lat/Long Iat Deg Lat MldSec M C DIMENSIONS Diameter of well 6 inches,drilled 300 ft (s,t r still 0 Depth of completed well 300 It REQUIRED) Long Deg Long Mm/Sec 0 CONSTRUCTION DETAILS Taz Parcel No 12108-d2_nM do 4 Casing �i.1 Welded � Diam from 0 ft to 29 eS ft CONSTRUCTION OR DECOMMISSION PROCEDURE Installed* Diam from ft to ft Fomiation Describe by color,character,size of material and structure,and the � ❑Liner itistallcd ate.. ❑Threaded Diam from ft to ft entrkindy and each c a the material at each stratum all watere n with least one entry for each change of information Indicate all water encountered i� Perforations- ❑Yes®No (USE ADDITIONAL SHEETS IF NECESSARY) = Type of perforator used MATERIAL FROM _-TO SIZE of perfs_m by—in and no of perfs—from ft to ft y >r Screens'®Yes ❑No Q K-Pac Location 293 0 Manufacturees Name Cook 1 Type eta t nl eSS Model No TOP Soil C Diam S Slot Siu 1 8 from 296 ft to _ft 913 Dian slot Size from ft to ft Brown silt bound Sand & cIrEvel is +r GravellFiiter packed []Yes ®No ❑Size of gravel/sand tQ ❑ Materials placed from @[o ft Brown Silt _ N Surface Seal 60 yes ❑No To what depth'? •s It Materials used in seat Beton 3 tQ Brown fine sand With some rDid any strata contain unusable water' ❑Yes J]No water C Type of water Depth of strata LMethod of sealing strata off _ L_ Sandy brown clay 9.; 117 t4 PUMP: Manufacturces Name GoiA de TYPe Sim H P Blue clay I— WATER LEVELS Land-surface elevation above mean sea level ft z Static level R5_ft below top of well Date Artesian pressure Ibs per square inch Date gray sit N Artesian water is controlled by 0 (ca,valve,etc) Fine to mediiirn brown gand "0 WELL TESTS Drawdown is amount water level is lowered below static level !t Was a pump test made'❑Yes U No If yes,by whom? With water Yield gal/nun with ft drawdown after hrs O0 Yield aalJmin with ft drawdown after hrs �' �j 0 Yield gal/men with ft drawdown after Ius IVIED i U Recovery data(tune taken as Zero when pump turned off(water level measured from y well top to water level) O Time Water Level Time Water Level Time Water Level c — wq,,hinaton State aJ — — E Date of tatr1if-parti-rientEcolc 4V i Bader tat 2 -- gal/rmn with 50 ft drawdown after__j__hrs cc Airtat gal/mm with stem set at ft for hrs C Artesian flow_ ¢p inDate ❑ Temperature of water_Was a chemical analysis made'? ❑Yes ®No Start Date_3j22 L02 Completed Date 3129 02 W WELL CONSTRUCTION CERTIFICATION I constructed and/or accept responsibility for construction of this well,and its compliance with all Washington well construction standards Matenals used and the information reported above are true to my best knowledge and belief - ®Dnller []Engineer[]Trainee N tint)—�{n �Ir � DnlhngCompany Davis Drilling Dnller/Engineerfrrainee Signature c i' n-- Address 340 NE DaV]S Farm Rd. Driller or Trainee License No 1706 City,State,Zip Belfairr WA 98528 lisfigt= licensed driHer's Registration No DAVISDI 1'ODA Date March 02 and License no Ecology is an Equal Opportunity Employer ECY 050-1-20(Rev 4/01) 10011 Blomberg Street SW, Olympia, WA 98512 13 Phone#: (360) 754-4612 Fax#: (360) 754-4848